DOCUMENT TITLE
REV
B
TRANSMITTAL NO.
DATE
17/05/2011
102796_ADW_00006
SUBMITTED FOR:
X
REVIEW / APPROVAL INFO FINAL
REVIEW DOES NOT CONSTITUTE ACCEPTANCE OF DESIGN DETAILS, CALCULATIONS, TEST METHODS OR MATERIALS DEVELOPED OR SELECTED BY VENDOR, NOR DOES IT RELIEVE VENDOR FROM FULL COMPLIANCE WITH CONTRACTUAL OR OTHER OBLIGATIONS.
VENDOR NAME:
A.
ACCEPTED
B.
102796_ADW_00006
VDRL DOC CODE:
D.
D1
NAME:
DATE:
PTSC PO No.
17742010/PTSCMC /MHH
SIGNATURE:
MT1-10-303
D1
0001
Reynaldo Eugenio
From: Sent: To: Cc: Subject: Attachments: Categories: Marco D'Onofrio [marcodonofrio@stistrumentazione.com] Tuesday, May 17, 2011 10:54 PM Reynaldo Eugenio Son Nguyen Minh; Parag Manvantray Thakar (Kuala Lumpur); Rogelio P Villanueva (Kuala Lumpur); Samantha Roxas; Mohd Faizal Mustafa (Kuala Lumpur); Senthi Rajaratnam D1-10-303 HIPPS-CCI Valve Technology - Vendor Document Submission - 102796 _ADW_0006_RevB INTERLOCKING MANIFOLD DRAWINGS 102796_ADW_0006_RevB.pdf Review
Dear Reynaldo,
Please find the updated Astava interlocking manifold drawings in rev B. Below there also the answers to the questions in the commented RevA document youve sent to us today. Comments: 1. Wiring from Transmitters to JB (Item 1) by Vendor? Answer 1 :The transmitters are not terminated to JB (item 1) but they can be connected directly to the control panel. The jb is used for the prox. Switches. 2. Please provide the JB (Item 1) termination drawing. Answer 2 : please see page 4 of attached drawing, this is the diagram for the prox. Switches. 3. We need hook up drawing. Answer 3 : for electrical hook up please see page 4 of attached drawing. Astava is not supplying other type of documentation . 4. Is the Pressure Transmitters going to Vendor JB (Item 1) or to Purchaser JB. If it is terminated at Vendor's JB (Item 1), please show in the document. Answer 4 : Pressure transmitters are not terminated at JB item 1 but they can be wired directly to the HIPPS panel.
Best regards
Marco D'Onofrio | Control Systems Software Technical Leader | TUV Functional Safety Engineer 1005/08 | CCI Valve / STI srl | Via dell'Industria 13 | 50056 Montelupo Fiorentino - Firenze | Italy | Direct Phone: +39 0571 5953206 | Cell Phone: +39 346 8509767 | marcodonofrio@stistrumentazione.com | www.ccivalve.com www.stiactuation.com
Disclaimer Any e-mail sent from STI Srl, its content and any files transmitted with it are intended solely for the addressee(s) and may be legally privileged and/or confidential. If you are not the intended recipient please delete the message and any attachments and contact the sender via return email. This email message does not form part of a legally binding contract or agreement between the recipient and STI Srl. Messages sent via this medium may be subject to delays, non-delivery and unauthorized alteration. All transmitted email has been prepared using information believed by the author to be reliable, accurate, and virus free. Although the mail item will have been checked for viruses, we cannot accept any responsibility for any consequential or any other losses due to transmitted viruses. STI Srl makes no warranty as to accuracy or completeness. In particular, STI Srl does not accept responsibility for changes made to email after being sent. Any opinions or recommendations expressed are solely those of the author and may be subject to change without notice. STI Srl Via G. Pascoli, 10 a/b 24020 Gorle - Bergamo Italy Phone: +39 035 29282 www.stistrumentazione.com
TOP VIEW
FRONT VIEW
SIDE VIEW
BOTTOM VIEW