Sunteți pe pagina 1din 39

Air Conditioners

Technical Data
Pair application

EEDEN11-100

RXS-J

Air Conditioners

Technical Data
Pair application

EEDEN11-100

RXS-J

Outdoor Unit Pair application RXS-J

TABLE OF CONTENTS
RXS-J

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Nominal Capacity And Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Sound Pressure Spectrum

10

30

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Wiring Diagrams - Single Phase

28

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping Diagrams

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Centre of Gravity

.................................... 9

Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensional Drawings

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cooling/Heating Capacity Tables

3
4

Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation Range

Split - Sky Air Outdoor Unit

36

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Outdoor Unit Pair application RXS-J

1
k ic Sni Ul p- pr ao t o J i dr - l ti S pauX PSRO

Features
Energy efficient units: up to class A energy labels

Outdoor unit silent operation: "silent" button on the remote control


lowers the operation sound of the outdoor unit by 3dBA to ensure a
quiet environment for the neighbourhood.

Outdoor units for pair application

Energy efficient units: full range A class energy labels

Daikin outdoor units are neat, sturdy and can easily be mounted on a
roof or terrace or simply placed against an outside wall

Split - Sky Air Outdoor Unit

Energy saving during standby mode: reduces current consumption


by about 80% when operating In standby. If no people are detected
for more than 20 minutes, the system will automatically switch to the
current-saving mode.

Outdoor unit silent operation: "silent" button on the remote control


lowers the operation sound of the outdoor unit by 3dBA to ensure a
quiet environment for the neighbourhood.

Outdoor units are fitted with a swing compressor, renowned for its low
noise and high energy efficiency

Outdoor Unit Pair application RXS-J

Specifications
FTXS20J2V1B /
RXS20J2V1B

2-1 Nominal Capacity And Nominal Input


Cooling capacity

Min.

kW
Btu/h

Nom.

Max.

Heating capacity

Power input

Cooling

Heating

FTXS50J2V1B /
RXS50J2V1B

1.3

1.3

1.4

1.7

1.7

4,400

4,400

4,800

5,800

5,800

1,120

1,120

1,200

1,460

1,460

2.0 (3)

2.5 (3)

3.5 (3)

4.2 (3)

5.0 (3)

Btu/h

6,800 (3)

8,500 (3)

11,900 (3)

14,300 (3)

17,100 (3)

kcal/h

1,720 (3)

2,150 (3)

3,010 (3)

3,010 (3)

4,300 (3)

2.8

3.2

4.0

5.0

5.3

Btu/h

9,600

10,900

13,600

17,100

18,100

kcal/h

2,410

2,750

3,440

4,300

4,560

1.3

1.3

1.4

1.7

1.7

4,400

4,400

4,800

5,800

5,800

Btu/h

Max.

FTXS42J2V1B /
RXS42J2V1B

kW

kW

Nom.

FTXS35J2V1B /
RXS35J2V1B

kcal/h

kW

Min.

FTXS25J2V1B /
RXS25J2V1B

kcal/h

1,120

1,200

1,460

1,460

kW

2.7 (4)

3.3

4.0 (4)

5.4 (4)

5.8 (4)

Btu/h

9,200 (4)

11,600 (4)

13,600 (4)

18,400 (4)

19,800 (4)

kcal/h

2,320 (4)

3,440 (4)

3,440 (4)

4,990 (4)

4.3

4.7

5.2

6.0

6.5

Btu/h

14,700

16,000

17,700

20,500

22,200
5,590

kW
kcal/h

3,700

4,470

5,160

Min.

kW

0.32

0.320

0.350

0.440

0.440

Nom.

kW

0.450

0.535

0.860

1.210

1.460

Max.

kW

0.810

0.810

1.190

2.330

1.810

Min.

kW

0.310

0.340

0.400

0.400

Nom.

kW

0.610

0.71

0.950

1.450

1.530

Max.

kW

2.000

1.290

1.460

1.980

EER

4.44

4.63

4.07

3.47

3.42

COP

4.43

4.65

4.21

3.72

3.79

Annual energy consumption


Energy label
Piping connections

225

270

430

605

730

Cooling

kWh

Heating

A
6.35

Liquid

OD

mm

6.35

6.35

6.35

6.35

Gas

OD

mm

9.52

9.52

9.52

9.52

12.7

Drain

OD

mm

18.0

18.0

18.0

18.0

18.0

Heat insulation

Both liquid and gas Both liquid and gas Both liquid and gas Both liquid and gas Both liquid and gas
pipes
pipes
pipes
pipes
pipes

Notes
(1) Energy label: scale from A (most efficient) to G (less efficient)
(2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
(3) Cooling: indoor temp. 27CDB, 19.0CWB; outdoor temp. 35CDB, 24CWB; equivalent piping length: 5m
(4) Heating: indoor temp. 20CDB; outdoor temp. 7CDB, 6CWB; equivalent refrigerant piping: 5m

2-2 Technical Specifications


Casing

Colour

Dimensions

Unit

Packed unit

Weight

RXS25J2V1B

RXS42J2V1B

RXS20J2V1B

RXS35J2V1B

RXS50J2V1B

Ivory white

Ivory white

Ivory white

Ivory white

Ivory white

Height

mm

550

550

550

550

735

Width

mm

765

765

765

765

825

Depth

mm

285

285

285

285

300

Height

mm

612

612

612

612

797

Width

mm

906

906

906

906

960

Depth

390

mm

364

364

364

364

Unit

kg

34

39

32

34

48

Packed unit

kg

38

45

35

38

53

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Specifications

2-2 Technical Specifications


Heat exchanger

Length

mm

Rows

Quantity

Fin pitch

mm

Stages

Quantity

Tube type
Fin

Type

Type
Air flow rate

Cooling High
Super
Low
Heating High
Super
Low

Fan motor

RXS20J2V1B

RXS35J2V1B

RXS50J2V1B

810

828

805

845

1.4

1.5

1.4

1.4

1.8

24

24

24

24

32

7 Hi-XA

8 Hi-XA

7 Hi-XA

7 Hi-XA

8 Hi-XA

Anti-corrosion
treatment (PE)

Anti-corrosion
treatment (PE)

Anti-corrosion
treatment (PE)

Anti-corrosion
treatment (PE)

Anti-corrosion
treatment (PE)
Propeller fan

Propeller fan

Propeller fan

Propeller fan

Propeller fan

m/min

33.5

37.3

36.2

36.0

50.9

cfm

1,183

1,317

1,278

1,271

1,797

m/min

32.7

30.1

30.1

30.6

48.9

cfm

1,155

1,063

1,063

1,080

1,727

m/min

28.3

31.3

30.6

28.3

45.0

cfm

999

1,105

1,080

999

1,589

m/min

28.5

25.6

25.6

27.2

43.1

cfm

1,006

904

904

960

1,522
KFD-380-50-8C

Model

D23H-28

D50R-28

D23H-28

D23H-28

23

50

23

23

53

Cooling High

rpm

860

890

860

920

780

Output
Speed

RXS42J2V1B

805

Waffle louvered fin Waffle louvered fin Waffle louvered fin Waffle louvered fin Waffle louvered fin

Treatment
Fan

RXS25J2V1B

Heating High

rpm

860

890

860

860

720

Sound power level

Cooling

High

dBA

61

63

61

63

63

Sound pressure level

Cooling

High

dBA

46

48

46

48

48

Silent operation

dBA

43

44

43

44

44

Heating
Compressor

High

dBA

47

48

47

48

48

Silent operation

dBA

44

45

44

45

45

Model

1YC23AEXD

2YC36BXD

1YC23AEXD

1YC23AEXD

2YC36BXD

Type

Hermetically
sealed swing
compressor

Hermetically
sealed swing
compressor

Hermetically
sealed swing
compressor

Hermetically
sealed swing
compressor

Hermetically
sealed swing
compressor

Output
Operation range

Refrigerant

600

1,100

600

600

1,100

Cooling

Ambient Min.

W
CDB

-10 (0.000)

-10 (0.000)

-10 (0.000)

-10 (0.000)

-10 (0.000)

Max.

CDB

46 (0.000)

46 (0.000)

46 (0.000)

46 (0.000)

46 (0.000)

Heating

Ambient Min.

CWB

-15

-15

-15

-15

-15

Max.

CWB

18

18

18

18

18

R-410A

R-410A

R-410A

R-410A

R-410A

Type
Charge

Refrigerant oil

kg

Type
Charged volume

Piping connections

Wiring connections

0.8

1.2

1.7

FVC50K

FVC50K

FVC50K
0.65

0.375

0.65

0.375

0.375

OD

mm

6.35

6.35

6.35

6.35

6.35

Gas

OD

mm

9.52

9.52

9.52

9.52

12.7

Hole

Hole

Hole

Hole

Hole

15

15

15

15

20

Drain

Type

Level difference

IU - OU Max.

Both liquid and gas Both liquid and gas Both liquid and gas Both liquid and gas Both liquid and gas
pipes
pipes
pipes
pipes
pipes

2-3 Electrical Specifications

Current

1.3
FVC50K

Liquid

Heat insulation

Power supply

1.0
FVC50K

Phase

RXS25J2V1B

RXS42J2V1B

RXS20J2V1B

RXS35J2V1B

RXS50J2V1B

1~

1~

1~

1~

1~

Frequency

Hz

50

50

50

50

50

Voltage

220-240

220-240

220-240

220-240

220-240

Nominal running
current (RLA)

Cooling

3.0 (1) 2.8 (2) 2.7 (3) 6.0 (1) 5.7 (2) 5.5 (3) 2.5 (1) 2.4 (2) 2.3 (3) 4.3 (1) 4.1 (2) 3.9 (3) 6.7 (1) 6.4 (2) 6.1 (3)

Heating

3.9 (1) 3.8 (2) 3.6 (3) 7.1 (1) 6.8 (2) 6.5 (3) 3.4 (1) 3.3 (2) 3.1 (3) 4.7 (1) 4.5 (2) 4.3 (3) 7.0 (1) 6.7 (2) 6.4 (3)

Starting current

Cooling

4.0

7.2

3.5

4.8

7.1

Heating

4.0

7.2

3.5

4.8

7.1
3

For power supply

Quantity

For connection with


indoor

Quantity

Remark

Earth wire included

Earth wire included

Earth wire included

Earth wire included

Earth wire included

Notes
(1) 220V, (2) 230V, (3) 240V

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Electrical data

3-1

Electrical Data

RXS20J2V1B
Representative Unit Combination
Indoor Unit

Outdoor Unit

FTXS20J2V1B

RXS20J2V1B

Power Supply
Hz - Volts

Comp
MCA

MFA

RHz

RLA

Max. 50Hz 264V


Min. 50Hz 198V

9.75

10

34

2.0

50 - 220
50 - 230

OFM

Voltage Range

IFM

NOTES

FLA

FLA

23

0.23

23

0.15

1.

2.1

50 - 240

2.
3.
4.

1.9

RLA is based on the following conditions,


Indoor temp. 27C DB/19.0 C WB.
Outdoor temp. 35C DB.
Maximum allowable voltage variation between phases is 2%.
Select wire size based on the larger value of MCA.
Instead of fuse, use circuit breaker.

SYMBOLS

MCA
MFA
RLA
OFM
IFM
FLA
W
RHz

: Min. Circuit Amps (A)


: Max. Fuse Amps (A)
: Rated Load Amps (A)
: Outdoor Fan Motor
: Indoor Fan Motor
: Full Load Amps (A)
: Fan Motor Rated Output (W)
: Rated Operating Frequency (Hz)

3D055006D
5;6-9%
5HSUHVHQWDWLYH8QLW&RPELQDWLRQ

3RZHU6XSSO\

,QGRRU8QLW

2XWGRRU8QLW

+]9ROWV

)7;6-9%

5;6-9%




9ROWDJH5DQJH

&RPS
0&$

0)$

5+]

5;6-9%

0D[+]9
0LQ+]9







5;6-9%







)/;6%$90%

5;6-9%

5;6-9%















0D[+]9
0LQ+]9























5/$LVEDVHGRQWKHIROORZLQJFRQGLWLRQV
,QGRRUWHPS&'%&:%
2XWGRRUWHPS&'%
 0D[LPXPDOORZDEOHYROWDJHYDULDWLRQEHWZHHQSKDVHVLV
 6HOHFWZLUHVL]HEDVHGRQWKHODUJHUYDOXHRI0&$
 ,QVWHDGRIIXVHXVHFLUFXLWEUHDNHU



6<0%2/6
































0D[+]9
0LQ+]9


)';6(90%






)/$







0D[+]9
0LQ+]9


))4%9%

127(6

)/$






,)0




)9;6)9%

2)0
5/$


0D[+]9
0LQ+]9










0&$
0)$
5/$
2)0
,)0
)/$
:
5+]

0LQ&LUFXLW$PSV $
0D[)XVH$PSV $
5DWHG/RDG$PSV $
2XWGRRU)DQ0RWRU
,QGRRU)DQ0RWRU
)XOO/RDG$PSV $
)DQ0RWRU5DWHG2XWSXW :
5DWHG2SHUDWLQJ)UHTXHQF\ +]

'

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Electrical data

3-1

Electrical Data

5;6-9%
5HSUHVHQWDWLYH8QLW&RPELQDWLRQ

3RZHU6XSSO\

,QGRRU8QLW

2XWGRRU8QLW

+]9ROWV

)7;6-9%

5;6-9%




9ROWDJH5DQJH

&RPS
0&$

0)$

5+]

5;6-9%









5;6-9%









5;6-9%









5;6-9%









5;6-9%









5;6-9%















6<0%2/6

0&$
0)$
5/$
2)0
,)0
)/$
:
5+]

































0LQ&LUFXLW$PSV $
0D[)XVH$PSV $
5DWHG/RDG$PSV $
2XWGRRU)DQ0RWRU
,QGRRU)DQ0RWRU
)XOO/RDG$PSV $
)DQ0RWRU5DWHG2XWSXW :
5DWHG2SHUDWLQJ)UHTXHQF\ +]









0D[+]9
0LQ+]9


)';6(90%











0D[+]9
0LQ+]9


)/;6%$90%











0D[+]9
0LQ+]9


)%4&9(%



5/$LVEDVHGRQWKHIROORZLQJFRQGLWLRQV
,QGRRUWHPSHUDWXUH&'%&:%
2XWGRRUWHPSHUDWXUH&'%
 0D[LPXPDOORZDEOHYROWDJHYDULDWLRQEHWZHHQSKDVHVLV
 6HOHFWZLUHVL]HEDVHGRQWKHODUJHUYDOXHRI0&$
 ,QVWHDGRIIXVHXVHFLUFXLWEUHDNHU











0D[+]9
0LQ+]9


)+4%99%

)/$







0D[+]9
0LQ+]9


))4%9%

127(6

)/$






,)0


0D[+]9
0LQ+]9


)9;6)9%

2)0
5/$


0D[+]9
0LQ+]9













'
RXS42J2V1B
Representative Unit Combination
Indoor Unit

Outdoor Unit

Power Supply
Hz - Volts

Voltage Range

Comp
MCA

MFA

RHz

50 - 220
FTXS42J2V1B

RXS42J2V1B

50 - 230
50 - 240

OFM
RLA

IFM

NOTES

FLA

FLA

50

0.23

23

0.15

1.

5.6
Max. 50Hz 264V
Min. 50Hz 198V

14.75

20

57

5.3
5.1

2.
3.
4.

RLA is based on the following conditions,


Indoor temp. 27C DB/19.0 C WB.
Outdoor temp. 35C DB.
Maximum allowable voltage variation between phases is 2%.
Select wire size based on the larger value of MCA.
Instead of fuse, use circuit breaker.

SYMBOLS

MCA
MFA
RLA
OFM
IFM
FLA
W
RHz

: Min. Circuit Amps (A)


: Max. Fuse Amps (A)
: Rated Load Amps (A)
: Outdoor Fan Motor
: Indoor Fan Motor
: Full Load Amps (A)
: Fan Motor Rated Output (W)
: Rated Operating Frequency (Hz)

3D059709B

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Electrical data

3-1

Electrical Data

RXS50J2V1B
Representative Unit Combination
Indoor Unit

Outdoor Unit

FTXS50J2V1B

RXS50J2V1B

Power Supply
Hz - Volts

Comp
MCA

MFA

RHz

RLA

Max. 50Hz 264V


Min. 50Hz 198V

19.75

20

66

6.0

50 - 240

FVXS50FV1B

RXS50J2V1B

NOTES

FLA

FLA

53

0.27

23

0.15

53

0.27

48

0.10

5.7
6.7

50 - 220
50 - 230

IFM

1.

6.3

50 - 220
50 - 230

OFM

Voltage Range

Max. 50Hz 264V


Min. 50Hz 198V

19.75

20

69

6.3

50 - 240

2.
3.
4.

RLA is based on the following conditions,


Indoor temp. 27C DB/19.0 C WB.
Outdoor temp. 35C DB.
Maximum allowable voltage variation between phases is 2%.
Select wire size based on the larger value of MCA.
Instead of fuse, use circuit breaker.

6.1

SYMBOLS

MCA
MFA
RLA
OFM
IFM
FLA
W
RHz

: Min. Circuit Amps (A)


: Max. Fuse Amps (A)
: Rated Load Amps (A)
: Outdoor Fan Motor
: Indoor Fan Motor
: Full Load Amps (A)
: Fan Motor Rated Output (W)
: Rated Operating Frequency (Hz)

3D070939
5;6-9%
5HSUHVHQWDWLYH8QLW&RPELQDWLRQ
,QGRRU8QLW

2XWGRRU8QLW

3RZHU6XSSO\
+]9ROWV

&RPS

2)0

,)0

127(6

9ROWDJH5DQJH

0&$

0)$

5+]

5/$

)/$

)/$

0D[+]9
0LQ+]9

















0D[+]9
0LQ+]9


















)/;6%$90%

5;6-9%





)';6&90%

5;6-9%





5/$LVEDVHGRQWKHIROORZLQJFRQGLWLRQV
,QGRRUWHPS&'%&:%
2XWGRRUWHPS&'%
 0D[LPXPDOORZDEOHYROWDJHYDULDWLRQEHWZHHQSKDVHVLV
 6HOHFWZLUHVL]HEDVHGRQWKHODUJHUYDOXHRI0&$
 ,QVWHDGRIIXVHXVHFLUFXLWEUHDNHU



6<0%2/6

0&$
0)$
5/$
2)0
,)0
)/$
:
5+]

0LQ&LUFXLW$PSV $
0D[)XVH$PSV $
5DWHG/RDG$PSV $
2XWGRRU)DQ0RWRU
,QGRRU)DQ0RWRU
)XOO/RDG$PSV $
)DQ0RWRU5DWHG2XWSXW :
5DWHG2SHUDWLQJ)UHTXHQF\ +]

'

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Electrical data

3-1

Electrical Data

5;6-9%
5HSUHVHQWDWLYH8QLW&RPELQDWLRQ
,QGRRU8QLW

2XWGRRU8QLW

3RZHU6XSSO\
+]9ROWV

&RPS

2)0

,)0

127(6

9ROWDJH5DQJH

0&$

0)$

5/$

)/$

)/$

0D[+]9
0LQ+]9















0D[+]9
0LQ+]9
















)+4%99%

5;6-9%





))4%9%

5;6-9%





5/$LVEDVHGRQWKHIROORZLQJFRQGLWLRQV
,QGRRUWHPS&'%&:%
2XWGRRUWHPS&'%
 0D[LPXPDOORZDEOHYROWDJHYDULDWLRQEHWZHHQSKDVHVLV
 6HOHFWZLUHVL]HEDVHGRQWKHODUJHUYDOXHRI0&$
 ,QVWHDGRIIXVHXVHFLUFXLWEUHDNHU


0LQLPXP6VFYDOXH

N9$

6<0%2/6

(TXLSHPHQWFRPSO\LQJZLWK(1

0&$
0)$
5/$
2)0
,)0
)/$
:

0LQ&LUFXLW$PSV $
0D[)XVH$PSV $
5DWHG/RDG$PSV $
2XWGRRU)DQ0RWRU
,QGRRU)DQ0RWRU
)XOO/RDG$PSV $
)DQ0RWRU5DWHG2XWSXW :

'
5;6-9%
5HSUHVHQWDWLYH8QLW&RPELQDWLRQ
,QGRRU8QLW

2XWGRRU8QLW

3RZHU6XSSO\
+]9ROWV

9ROWDJH5DQJH

&RPS
0&$

0)$


)&4&9(%

5;6-9%



5/$

2)0

,)0

127(6

)/$

)/$










0D[+]9
0LQ+]9










0LQLPXP6VFYDOXH

N9$

(TXLSHPHQWFRPSO\LQJZLWK(1



5/$LVEDVHGRQWKHIROORZLQJFRQGLWLRQV
,QGRRUWHPS&'%&:%
2XWGRRUWHPS&'%
 0D[LPXPDOORZDEOHYROWDJHYDULDWLRQEHWZHHQSKDVHVLV
 6HOHFWZLUHVL]HEDVHGRQWKHODUJHUYDOXHRI0&$
 ,QVWHDGRIIXVHXVHFLUFXLWEUHDNHU
6<0%2/6

0&$
0)$
5/$
2)0
,)0
)/$
:

0LQ&LUFXLW$PSV $
0D[)XVH$PSV $
5DWHG/RDG$PSV $
2XWGRRU)DQ0RWRU
,QGRRU)DQ0RWRU
)XOO/RDG$PSV $
)DQ0RWRU5DWHG2XWSXW :

'

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FTXS20J2V1B + RXS20J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

2.05
2.14
2.23
2.28
2.42
2.51

1.84
1.81
1.94
2.09
2.03
1.99

0.35
0.35
0.35
0.35
0.35
0.36

9.4
0.14

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

1.96
2.05
2.14
2.19
2.32
2.42

1.80
1.77
1.90
2.05
2.00
1.96

0.38
0.38
0.38
0.38
0.39
0.39

1.86
1.95
2.05
2.09
2.23
2.32

1.76
1.73
1.87
2.02
1.97
1.93

0.41
0.41
0.42
0.42
0.42
0.42

PI

TC

PI

0.60
0.61
0.62
0.62
0.62
0.63

3.04
2.94
2.91
2.87
2.85
2.81

0.62
0.63
0.64
0.64
0.64
0.65

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

1.82
1.72
1.69
1.65
1.63
1.59

0.52
0.53
0.54
0.54
0.54
0.55

2.12
2.03
1.99
1.95
1.94
1.90

0.54
0.55
0.56
0.57
0.57
0.57

-5

2.43
2.33
2.30
2.26
2.24
2.20

0.57
0.58
0.59
0.59
0.59
0.60

1.74
1.72
1.85
2.00
1.96
1.92

TC

35
SHC

PI

TC

40
SHC

PI

0.43
0.43
0.43
0.43
0.43
0.44

1.77
1.86
1.95
2.00
2.14
2.23

1.71
1.69
1.83
1.98
1.94
1.91

0.45
0.45
0.45
0.45
0.45
0.45

1.68
1.77
1.86
1.91
2.05
2.14

1.67
1.66
1.80
1.95
1.91
1.88

0.48
0.48
0.48
0.48
0.49
0.49

9.9

Indoor
EDB
C

-10

1.83
1.92
2.01
2.06
2.19
2.29

PI

2.79
2.70
2.66
2.63
2.61
2.57

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.
5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables. (Figures out of the tables should not be used for calculation.)
About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D070643

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FTXS25J2V1B + RXS25J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

2.56
2.68
2.79
2.85
3.02
3.14

2.18
2.15
2.29
2.45
2.38
2.33

0.41
0.41
0.42
0.42
0.42
0.42

10.8
0.16

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

2.44
2.56
2.68
2.73
2.91
3.02

2.13
2.10
2.24
2.41
2.34
2.29

0.45
0.45
0.45
0.46
0.46
0.46

2.33
2.44
2.56
2.62
2.79
2.90

2.08
2.05
2.20
2.36
2.30
2.26

0.49
0.49
0.49
0.50
0.50
0.50

PI

TC

PI

0.69
0.71
0.72
0.72
0.73
0.73

3.71
3.60
3.55
3.51
3.48
3.44

0.72
0.73
0.74
0.75
0.75
0.76

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.22
2.11
2.06
2.02
1.99
1.95

0.60
0.62
0.62
0.63
0.63
0.64

2.59
2.48
2.43
2.39
2.37
2.32

0.63
0.65
0.65
0.66
0.66
0.67

-5

2.97
2.85
2.81
2.76
2.74
2.69

0.66
0.67
0.68
0.69
0.69
0.70

2.05
2.03
2.18
2.34
2.28
2.24

TC

35
SHC

PI

TC

40
SHC

PI

0.51
0.51
0.51
0.51
0.51
0.52

2.21
2.33
2.44
2.50
2.67
2.79

2.02
2.00
2.15
2.32
2.26
2.22

0.53
0.53
0.53
0.54
0.54
0.54

2.10
2.21
2.33
2.38
2.56
2.67

1.97
1.95
2.10
2.27
2.22
2.19

0.57
0.57
0.57
0.57
0.58
0.58

11.9

Indoor
EDB
C

-10

2.28
2.40
2.51
2.57
2.74
2.86

PI

3.41
3.30
3.25
3.21
3.19
3.14

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.
5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables. (Figures out of the tables should not be used for calculation.)
About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D070648

10

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FFQ25B8V1B + RXS25J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

2.56
2.68
2.79
2.85
3.02
3.14

1.95
1.92
2.01
2.13
2.06
2.01

0.56
0.56
0.57
0.57
0.57
0.58

9
0.24

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

2.44
2.56
2.68
2.73
2.91
3.02

1.89
1.86
1.96
2.08
2.02
1.97

0.61
0.62
0.62
0.62
0.63
0.63

2.33
2.44
2.56
2.62
2.79
2.90

1.84
1.81
1.92
2.04
1.97
1.93

0.67
0.67
0.67
0.68
0.68
0.68

PI

TC

PI

0.90
0.92
0.93
0.94
0.94
0.95

3.60
3.49
3.44
3.40
3.38
3.33

0.93
0.95
0.96
0.97
0.97
0.98

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.15
2.04
2.00
1.96
1.93
1.89

0.78
0.80
0.81
0.82
0.82
0.83

2.52
2.41
2.36
2.32
2.29
2.25

0.82
0.84
0.84
0.85
0.86
0.87

-5

2.88
2.77
2.72
2.68
2.66
2.61

0.85
0.87
0.88
0.89
0.90
0.90

1.81
1.79
1.90
2.02
1.96
1.91

TC

35
SHC

PI

TC

40
SHC

PI

0.69
0.69
0.70
0.70
0.70
0.71

2.21
2.33
2.44
2.50
2.67
2.79

1.78
1.76
1.87
1.99
1.93
1.89

0.72
0.73
0.73
0.73
0.73
0.74

2.10
2.21
2.33
2.38
2.56
2.67

1.72
1.71
1.82
1.94
1.89
1.85

0.78
0.78
0.78
0.78
0.79
0.79

Indoor
EDB
C

-10

2.28
2.40
2.51
2.57
2.74
2.86

PI

3.31
3.20
3.16
3.11
3.09
3.05

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

3D055487C

Split - Sky Air Outdoor Unit

11

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FLXS25BAVMB + RXS25J2V1B

Cooling

AFR
BF

220V-240V 50 Hz

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

2.52
2.68
2.79
2.85
3.02
3.14

1.77
1.76
1.83
1.91
1.84
1.79

0.49
0.50
0.50
0.51
0.51
0.51

7.6
0.32

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

2.44
2.56
2.68
2.73
2.91
3.02

1.73
1.71
1.78
1.86
1.79
1.74

0.55
0.55
0.55
0.55
0.56
0.56

2.33
2.44
2.56
2.62
2.79
2.90

1.67
1.65
1.72
1.81
1.75
1.70

0.59
0.60
0.60
0.60
0.61
0.61

PI

TC

PI

0.96
0.98
0.99
1.00
1.00
1.01

3.82
3.71
3.66
3.61
3.59
3.54

0.99
1.01
1.02
103
1.03
1.04

AFR

220V-240V 50 Hz

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.29
2.17
2.12
2.08
2.05
2.01

0.83
0.85
0.86
087
0.87
0.88

2.67
2.56
2.51
2.46
2.44
2.39

0.87
0.89
0.90
0.91
0.91
0.92

-5

3.06
2.94
2.89
2.85
2.82
2.77

0.91
0.93
0.94
0.95
0.95
0.96

1.65
1.63
1.70
1.79
1.73
1.68

TC

35
SHC

PI

TC

40
SHC

PI

0.61
0.62
0.62
0.62
0.63
0.63

2.21
2.33
2.44
2.50
2.67
2.79

1.61
1.59
1.67
1.76
1.70
1.66

0.64
0.65
0.65
0.65
0.65
0.66

2.10
2.21
2.33
2.38
2.56
2.67

1.55
1.54
1.62
1.71
1.66
1.62

0.69
0.69
0.70
0.70
0.70
0.71

9.2

Indoor
EDB
C

-10

2.28
2.40
2.51
2.57
2.74
2.86

PI

3.52
3.40
3.35
3.31
3.28
3.24

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

3D055037C

12

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FVXS25FV1B + RXS25J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

2.56
2.68
2.79
2.85
3.02
3.14

2.00
1.97
2.08
2.21
2.13
2.08

0.44
0.44
0.44
0.44
0.45
0.45

8.2
0.10

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

2.44
2.56
2.68
2.73
2.91
3.02

1.95
1.92
2.03
2.16
2.09
2.04

0.48
0.48
0.48
0.49
0.49
0.49

2.33
2.44
2.56
2.62
2.79
2.90

1.89
1.87
1.98
2.11
2.05
2.01

0.52
0.52
0.53
0.53
0.53
0.53

PI

TC

PI

0.77
0.79
0.80
0.80
0.81
0.81

3.82
3.71
3.66
3.61
3.59
3.54

0.80
0.82
0.82
0.83
0.83
0.84

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.29
2.17
2.12
2.08
2.05
2.01

0.67
0.69
0.69
0.70
0.70
0.71

2.67
2.56
2.51
2.46
2.44
2.39

0.70
0.72
0.73
0.73
0.74
0.74

-5

3.06
2.94
2.89
2.85
2.82
2.77

0.73
0.75
0.76
0.77
0.77
0.78

1.87
1.84
1.96
2.09
2.03
1.99

TC

35
SHC

PI

TC

40
SHC

PI

0.54
0.54
0.54
0.54
0.55
0.55

2.21
2.33
2.44
2.50
2.67
2.79

1.84
1.81
1.93
2.07
2.01
1.97

0.56
0.57
0.57
0.57
0.57
0.58

2.10
2.21
2.33
2.38
2.56
2.67

1.78
1.76
1.89
2.02
1.97
1.93

0.61
0.61
0.61
0.61
0.62
0.62

8.8

Indoor
EDB
C

-10

2.28
2.40
2.51
2.57
2.74
2.86

PI

3.52
3.40
3.35
3.31
3.28
3.24

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

3D056491C

Split - Sky Air Outdoor Unit

13

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FVXS35FV1B + RXS35J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

3.59
3.75
3.91
3.99
4.23
4.39

2.54
2.50
2.60
2.72
2.61
2.54

0.78
0.79
0.79
0.79
0.80
0.81

8.5
0.11

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

3.42
3.58
3.75
3.83
4.07
4.23

2.46
2.42
2.52
2.65
2.55
2.48

0.86
0.86
0.87
0.87
0.88
0.88

3.26
3.42
3.58
3.66
3.90
4.07

2.37
2.34
2.45
2.57
2.49
2.42

0.93
0.94
0.94
0.94
0.95
0.96

PI

TC

PI

1.19
1.22
1.23
1.24
1.25
1.26

5.06
4.91
4.84
4.78
4.75
4.69

1.23
1.26
1.27
1.28
1.29
1.30

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

3.03
2.87
2.81
2.75
2.72
2.66

1.03
1.06
1.07
1.08
1.09
1.10

3.54
3.38
3.32
3.26
3.23
3.16

1.08
1.11
1.12
1.13
1.14
1.15

-5

4.05
3.89
3.83
3.77
3.73
3.67

1.13
1.16
1.17
1.18
1.19
1.20

2.34
2.31
2.42
2.55
2.46
2.40

TC

35
SHC

PI

TC

40
SHC

PI

0.96
0.97
0.97
0.97
0.98
0.99

3.10
3.26
3.42
3.50
3.74
3.90

2.29
2.26
2.37
2.50
2.43
2.37

1.01
1.01
1.02
1.02
1.03
1.03

2.93
3.10
3.26
3.34
3.58
3.74

2.21
2.18
2.30
2.43
2.36
2.31

1.08
1.09
1.09
1.10
1.10
1.11

9.4

Indoor
EDB
C

-10

3.19
3.36
3.52
3.60
3.84
4.00

PI

4.66
4.50
4.44
4.38
4.34
4.28

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

3D056492C

14

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FBQ35C7VEB + RXS35J2V1B
Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

3.48
3.64
3.80
3.87
4.11
4.27

2.70
2.65
2.80
2.96
2.86
2.79

0.90
0.90
0.91
0.91
0.92
0.92

11.5
0.15

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

3.33
3.48
3.64
3.72
3.95
4.11

2.62
2.58
2.73
2.90
2.81
2.74

0.98
0.99
0.99
1.00
1.00
1.01

3.17
3.32
3.48
3.56
3.79
3.95

2.55
2.51
2.66
2.84
2.75
2.69

1.07
1.08
1.08
1.08
1.09
1.10

PI

TC

PI

1.19
1.22
1.23
1.24
1.25
1.26

4.50
4.36
4.31
4.25
4.22
4.17

1.23
1.26
1.27
1.28
1.29
1.30

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.69
2.55
2.50
2.44
2.42
2.36

1.03
1.06
1.07
1.08
1.09
1.10

3.14
3.01
2.95
2.90
2.87
2.81

1.08
1.11
1.12
1.13
1.14
1.15

-5

3.60
3.46
3.40
3.35
3.32
3.26

1.13
1.16
1.17
1.18
1.19
1.20

2.52
2.48
2.64
2.81
2.73
2.67

TC

35
SHC

PI

TC

40
SHC

PI

1.11
1.11
1.12
1.12
1.13
1.13

3.01
3.17
3.32
3.40
3.63
3.79

2.47
2.44
2.60
2.77
2.70
2.64

1.16
1.16
1.17
1.17
1.18
1.18

2.85
3.01
3.16
3.24
3.48
3.63

2.40
2.37
2.53
2.71
2.64
2.59

1.24
1.25
1.25
1.26
1.26
1.27

11.5

Indoor
EDB
C

-10

3.10
3.26
3.42
3.49
3.73
3.89

PI

4.14
4.00
3.94
3.89
3.86
3.81

10

3D055493C
Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

Split - Sky Air Outdoor Unit

15

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FDXS35E7VMB + RXS35J2V1B
Cooling

AFR
BF

220V-240V 50Hz

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

Outdoor
TC

temperature:
20
SHC
PI

3.48
3.64
3.80
3.87
4.11
4.27

2.46
2.42
2.51
2.63
2.53
2.46

0.84
0.84
0.85
0.85
0.86
0.86

TC

25
SHC

PI

3.33
3.48
3.64
3.72
3.95
4.11

2.38
2.34
2.44
2.56
2.47
2.40

0.92
0.92
0.93
0.93
0.94
0.94

AFR

220V-240V 50Hz

Indoor
EDB
C
15.0
20.0
22.0
24.0
25.0
27.0

Outdoor
temperature:
-10
-5
TC
PI
TC
PI
2.69
2.55
2.50
2.44
2.42
2.36

1.00
1.02
1.04
1.05
1.05
1.06

3.14
3.01
2.95
2.90
2.87
2.81

1.05
1.07
1.08
1.09
1.10
1.11

8.7
0.17

TC

30
SHC

PI

3.17
3.32
3.48
3.56
3.79
3.95

2.30
2.26
2.37
2.49
2.40
2.34

1.00
1.00
1.01
1.01
1.02
1.02

TC

(CDB)
32
SHC

PI

TC

35
SHC

PI

TC

40
SHC

PI

3.10
3.26
3.42
3.49
3.73
3.89

2.26
2.23
2.34
2.46
2.38
2.32

1.03
1.03
1.04
1.04
1.05
1.05

3.01
3.17
3.32
3.40
3.63
3.79

2.21
2.19
2.30
2.42
2.34
2.29

1.08
1.08
1.09
1.09
1.10
1.10

2.85
3.01
3.16
3.24
3.48
3.63

2.13
2.11
2.22
2.35
2.28
2.23

1.16
1.16
1.17
1.17
1.18
1.18

8.7

(CWB)
0

10

TC

PI

TC

PI

TC

PI

3.60
3.46
3.40
3.35
3.32
3.26

1.10
1.12
1.13
1.14
1.15
1.16

4.14
4.00
3.94
3.89
3.86
3.81

1.15
1.18
1.19
1.20
1.21
1.22

4.50
4.36
4.31
4.25
4.22
4.17

1.19
1.22
1.23
1.24
1.25
1.26

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate (m3/min.)


Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity (kW)
Sensible heat capacity
Power input

(C)
(C)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght: 5m
(2) Level difference: 0m
shows nominal (rated) capacities and power input.

3D055043C

16

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FFQ35B8V1B + RXS35J2V1B

Cooling

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

AFR
BF

50 Hz 220V-240V

20
22
25
27
30
32

Heating

Outdoor
TC

temperature:
20
SHC
PI

3.48
3.64
3.80
3.87
4.11
4.27

2.48
2.44
2.54
2.66
2.56
2.49

0.84
0.85
0.85
0.86
0.86
0.87

TC

25
SHC

PI

3.33
3.48
3.64
3.72
3.95
4.11

2.40
2.36
2.46
2.59
2.50
2.43

0.93
0.93
0.93
0.94
0.94
0.95

Outdoor
temperature:
-10
-5
TC
PI
TC
PI

15.0
20.0
22.0
24.0
25.0
27.0

2.69
2.55
2.50
2.44
2.42
2.36

1.01
1.04
1.05
1.06
1.07
1.08

3.14
3.01
2.95
2.90
2.87
2.81

TC

30
SHC

PI

3.17
3.32
3.48
3.56
3.79
3.95

2.32
2.28
2.39
2.52
2.44
2.37

1.01
1.01
1.02
1.02
1.03
1.03

AFR

50 Hz 220V-240V

Indoor
EDB
C

10
0.25

1.06
1.09
1.10
1.11
1.12
1.13

TC

(CDB)
32
SHC

PI

TC

35
SHC

PI

TC

40
SHC

PI

3.10
3.26
3.42
3.49
3.73
3.89

2.29
2.25
2.36
2.49
2.41
2.35

1.04
1.04
1.05
1.05
1.06
1.06

3.01
3.17
3.32
3.40
3.63
3.79

2.24
2.21
2.32
2.45
2.38
2.32

1.09
1.09
1.10
1.10
1.11
1.11

2.85
3.01
3.16
3.24
3.48
3.63

2.16
2.13
2.25
2.39
2.32
2.26

1.17
1.17
1.18
1.18
1.19
1.19

10

(CWB)
0

10

TC

PI

TC

PI

TC

PI

3.60
3.46
3.40
3.35
3.32
3.26

1.11
1.14
1.15
1.16
1.17
1.18

4.14
4.00
3.94
3.89
3.86
3.81

1.17
1.20
1.21
1.22
1.23
1.24

4.50
4.36
4.31
4.25
4.22
4.17

1.21
1.24
1.25
1.26
1.27
1.28

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air owrate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

3D055489C

Split - Sky Air Outdoor Unit

17

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FHQ35BVV1B + RXS35J2V1B

Cooling

AFR
BF

220V-240V 50 Hz

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

3.48
3.64
3.80
3.87
4.11
4.27

2.76
2.72
2.87
3.05
2.95
2.88

0.81
0.81
0.81
0.82
0.82
0.83

13
0.20

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

3.33
3.48
3.64
3.72
3.95
4.11

2.69
2.65
2.81
2.99
2.90
2.83

0.88
0.89
0.89
0.89
0.90
0.91

3.17
3.32
3.48
3.56
3.79
3.95

2.61
2.58
2.74
2.93
2.84
2.78

0.96
0.97
0.97
0.97
0.98
0.98

PI

TC

PI

1.08
1.11
1.12
1.13
1.14
1.15

4.50
4.36
4.31
4.25
4.22
4.17

1.12
1.15
1.16
1.17
1.17
1.18

AFR

220V-240V 50 Hz

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.69
2.55
2.50
2.44
2.42
2.36

0.94
0.96
0.97
0.98
0.99
1.00

3.14
3.01
2.95
2.90
2.87
2.81

0.98
1.01
1.02
1.03
1.03
1.04

-5

3.60
3.46
3.40
3.35
3.32
3.26

1.03
1.06
1.07
1.08
1.08
1.09

2.58
2.55
2.72
2.90
2.82
2.76

TC

35
SHC

PI

TC

40
SHC

PI

0.99
1.00
1.00
1.00
1.01
1.02

3.01
3.17
3.32
3.40
3.63
3.79

2.54
2.51
2.68
2.87
2.79
2.73

1.04
1.04
1.05
1.05
1.06
1.06

2.85
3.01
3.16
3.24
3.48
3.63

2.47
2.44
2.61
2.80
2.73
2.68

1.12
1.12
1.13
1.13
1.13
1.14

13

Indoor
EDB
C

-10

3.10
3.26
3.42
3.49
3.73
3.89

PI

4.14
4.00
3.94
3.89
3.86
3.81

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

3D055046C

18

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FLXS35BAVMB + RXS35J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

2.72
3.34
3.91
3.99
4.23
4.39

1.92
2.14
2.42
2.51
2.40
2.32

0.87
0.87
0.88
0.88
0.89
0.89

8.6
0.35

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

2.72
3.34
3.75
3.83
4.07
4.23

1.92
2.14
2.34
2.43
2.33
2.26

0.95
0.96
0.96
0.96
0.97
0.98

2.72
3.34
3.58
3.66
3.90
4.07

1.92
2.14
2.26
2.34
2.26
2.19

1.03
1.04
1.04
1.05
1.05
1.06

PI

TC

PI

1.20
1.23
1.24
1.25
1.26
1.27

4.50
4.36
4.31
4.25
4.18
3.91

1.24
1.27
1.28
1.29
1.30
1.30

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.69
2.55
2.50
2.44
2.42
2.36

1.04
1.07
1.08
1.09
1.10
1.11

3.14
3.01
2.95
2.90
2.87
2.81

1.09
1.12
1.13
1.14
1.15
1.16

-5

3.60
3.46
3.40
3.35
3.32
3.26

1.14
1.17
1.18
1.19
1.20
1.21

1.92
2.14
2.22
2.31
2.23
2.16

TC

35
SHC

PI

TC

40
SHC

PI

1.07
1.07
1.08
1.08
1.09
1.09

2.72
3.26
3.42
3.50
3.74
3.90

1.92
2.10
2.17
2.27
2.19
2.13

1.12
1.12
1.13
1.13
1.14
1.14

2.72
3.10
3.26
3.34
3.58
3.74

1.92
2.01
2.09
2.19
2.12
2.06

1.20
1.21
1.21
1.21
1.22
1.23

9.8

Indoor
EDB
C

-10

2.72
3.34
3.52
3.60
3.84
4.00

PI

4.14
4.00
3.94
3.89
3.86
3.81

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


(1) Corresponding refrigerant piping lenght:
5m
(2) Level difference:
0m
shows nominal (rated) capacities and power input.

3D055039C

Split - Sky Air Outdoor Unit

19

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FTXS35J2V1B + RXS35J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

3.59
3.75
3.91
3.99
4.23
4.39

2.67
2.63
2.75
2.91
2.80
2.73

0.66
0.66
0.67
0.67
0.67
0.68

11.4
0.21

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

3.42
3.58
3.75
3.83
4.07
4.23

2.59
2.55
2.68
2.84
2.74
2.67

0.72
0.73
0.73
0.73
0.74
0.74

3.26
3.42
3.58
3.66
3.90
4.07

2.51
2.48
2.61
2.77
2.68
2.62

0.79
0.79
0.79
0.80
0.80
0.81

PI

TC

PI

0.93
0.95
0.96
0.97
0.97
0.98

4.50
4.36
4.31
4.25
4.22
4.17

0.96
0.98
0.99
1.00
1.00
1.01

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

2.69
2.55
2.50
2.44
2.42
2.36

0.80
0.82
0.83
0.84
0.85
0.85

3.14
3.01
2.95
2.90
2.87
2.81

0.84
0.86
0.87
0.88
0.89
0.89

-5

3.60
3.46
3.40
3.35
3.32
3.26

0.88
0.90
0.91
0.92
0.92
0.93

2.48
2.45
2.58
2.74
2.66
2.60

TC

35
SHC

PI

TC

40
SHC

PI

0.81
0.82
0.82
0.82
0.83
0.83

3.10
3.26
3.42
3.50
3.74
3.90

2.43
2.40
2.54
2.70
2.62
2.57

0.85
0.85
0.86
0.86
0.87
0.87

2.93
3.10
3.26
3.34
3.58
3.74

2.35
2.33
2.47
2.64
2.57
2.51

0.91
0.92
0.92
0.92
0.93
0.93

12.1

Indoor
EDB
C

-10

3.19
3.36
3.52
3.60
3.84
4.00

PI

4.14
4.00
3.94
3.89
3.86
3.81

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.
5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables. (Figures out of the tables should not be used for calculation.)
About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D070670A

20

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FTXS42J2V1B + RXS42J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

4.30
4.50
4.69
4.79
5.08
5.27

3.10
3.05
3.18
3.34
3.22
3.13

0.93
0.93
0.94
0.94
0.95
0.96

11.3
0.14

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

4.11
4.30
4.49
4.59
4.88
5.07

3.00
2.96
3.09
3.26
3.14
3.06

1.02
1.02
1.03
1.03
1.04
1.04

3.91
4.11
4.30
4.40
4.69
4.88

2.90
2.86
3.01
3.17
3.07
2.99

1.11
1.11
1.12
1.12
1.13
1.13

PI

TC

PI

1.42
1.45
1.46
1.48
1.48
1.50

6.07
5.89
5.81
5.74
5.70
5.63

1.47
1.50
1.51
1.52
1.53
1.54

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

3.64
3.45
3.37
3.30
3.26
3.19

1.23
1.26
1.27
1.29
1.29
1.30

4.24
4.06
3.98
3.91
3.87
3.80

1.29
1.32
1.33
1.34
1.35
1.36

-5

4.85
4.67
4.59
4.52
4.48
4.41

1.35
1.38
1.39
1.40
1.41
1.42

2.87
2.83
2.97
3.14
3.04
2.96

TC

35
SHC

PI

TC

40
SHC

PI

1.14
1.15
1.15
1.16
1.16
1.17

3.72
3.91
4.10
4.20
4.49
4.68

2.81
2.77
2.92
3.09
2.99
2.92

1.20
1.20
1.21
1.21
1.22
1.22

3.52
3.71
3.91
4.00
4.29
4.49

2.71
2.68
2.83
3.01
2.92
2.86

1.29
1.29
1.30
1.30
1.31
1.31

12.2

Indoor
EDB
C

-10

3.83
4.03
4.22
4.32
4.61
4.80

PI

5.59
5.40
5.33
5.25
5.21
5.14

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.
5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables. (Figures out of the tables should not be used for calculation.)
About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D070646

Split - Sky Air Outdoor Unit

21

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FDXS50C7VMB + RXS50J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

3.92
4.81
5.58
5.70
6.04
6.27

2.76
3.08
3.47
3.59
3.44
3.32

1.13
1.22
1.28
1.28
1.30
1.30

12.0
0.11

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

3.92
4.81
5.35
5.47
5.81
6.04

2.76
3.08
3.35
3.47
3.33
3.23

1.29
1.37
1.40
1.41
1.42
1.42

3.92
4.81
5.12
5.23
5.58
5.81

2.76
3.08
3.23
3.36
3.23
3.13

1.44
1.51
1.52
1.53
1.54
1.55

PI

TC

PI

1.88
1.92
1.94
1.95
1.96
1.98

6.52
6.32
6.24
6.16
6.12
6.04

1.94
1.98
2.00
2.02
2.03
2.04

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

3.90
3.70
3.62
3.54
3.50
3.42

1.62
1.67
1.68
1.70
1.71
1.73

4.56
4.36
4.28
4.20
4.16
4.08

1.70
1.75
1.76
1.78
1.79
1.81

-5

5.21
5.01
4.93
4.85
4.81
4.73

1.78
1.83
1.84
1.86
1.87
1.89

2.76
3.07
3.18
3.31
3.19
3.10

TC

35
SHC

PI

TC

40
SHC

PI

1.50
1.57
1.57
1.58
1.59
1.60

3.92
4.65
4.88
5.00
5.35
5.58

2.76
3.00
3.11
3.24
3.13
3.04

1.59
1.64
1.65
1.65
1.66
1.67

3.92
4.42
4.65
4.77
5.11
5.34

2.76
2.88
3.00
3.13
3.03
2.95

1.74
1.76
1.77
1.77
1.78
1.79

12.0

Indoor
EDB
C

-10

3.92
4.79
5.02
5.14
5.49
5.72

PI

6.00
5.80
5.72
5.64
5.60
5.52

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.
5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables.
(Figures out of the tables should not be used for calculation.)
About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D052271D

22

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FFQ50B8V1B + RXS50J2V1B

Cooling

AFR
BF

50 Hz 230V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

4.76
4.92
5.07
5.15
5.38
5.54

3.51
3.54
3.58
3.59
3.65
3.68

1.45
1.48
1.50
1.52
1.55
1.58

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

4.61
4.77
4.92
5.00
5.23
5.39

3.44
3.47
3.51
3.52
3.58
3.61

1.55
1.57
1.60
1.61
1.65
1.68

4.46
4.62
4.77
4.85
5.08
5.24

3.37
3.40
3.44
3.45
3.51
3.54

1.64
1.67
1.69
1.71
1.74
1.77

Outdoor temperature: (CWB)


-5
0
TC
PI
TC
PI
4.09
4.06
4.04
4.02
4.01
3.98

AFR

50 Hz 230V

Indoor
EDB
C

TC

PI

TC

PI

16.0
18.0
20.0
21.0
22.0
24.0

2.76
2.73
2.70
2.69
2.68
2.65

1.41
1.48
1.55
1.58
1.62
1.69

3.43
3.40
3.37
3.36
3.34
3.32

1.51
1.58
1.65
1.68
1.72
1.79

-15

12.0
0.16

-10

1.60
1.67
1.74
1.78
1.81
1.89

PI

TC

35
SHC

PI

TC

40
SHC

PI

1.68
1.70
1.73
1.74
1.78
1.81

4.31
4.47
4.62
4.70
4.93
5.09

3.30
3.33
3.37
3.38
3.44
3.47

1.74
1.76
1.79
1.80
1.84
1.87

4.16
4.32
4.47
4.55
4.78
4.94

3.23
3.26
3.30
3.31
3.37
3.40

1.83
1.86
1.88
1.90
1.93
1.96

4.40
4.56
4.71
4.79
5.02
5.18

3.34
3.38
3.41
3.43
3.48
3.51

TC

PI

TC

PI

5.56
5.53
5.50
5.49
5.47
5.45

1.82
1.89
1.96
2.00
2.03
2.10

6.09
6.06
6.03
6.02
6.00
5.98

1.90
1.97
2.04
2.07
2.11
2.18

12.0

4.76
4.73
4.70
4.69
4.67
4.65

1.70
1.77
1.84
1.88
1.91
1.98

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.

5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables. (Figures out of the tables should not be used for calculation.)
SHC is based on each EWB and EDB.
SHC*=SHC correction for other dry bulb.
=0.02*AFR(m3/min.)*(1-BF)*(DB*-EDB)
Add SHC*TO SHC.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D060463B

Split - Sky Air Outdoor Unit

23

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FLXS50BAVMB + RXS50J2V1B

Cooling

AFR
BF

50 Hz 220-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

4.96
5.12
5.27
5.35
5.58
5.74

3.26
3.30
3.33
3.35
3.40
3.43

1.37
1.40
1.42
1.44
1.47
1.50

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

4.81
4.97
5.12
5.20
5.43
5.59

3.19
3.23
3.26
3.28
3.33
3.36

1.47
1.49
1.52
1.53
1.57
1.60

4.66
4.82
4.97
5.05
5.28
5.44

3.12
3.16
3.19
3.21
3.26
3.29

1.56
1.59
1.61
1.63
1.66
1.69

Outdoor temperature: (CWB)


-5
0
TC
PI
TC
PI
4.54
4.51
4.48
4.46
4.45
4.42

AFR

50 Hz 220-240V

Indoor
EDB
C

TC

PI

TC

PI

16.0
18.0
20.0
21.0
22.0
24.0

3.06
3.03
3.00
2.98
2.97
2.94

1.31
1.37
1.44
1.47
1.50
1.57

3.80
3.77
3.74
3.72
3.71
3.68

1.40
1.46
1.53
1.56
1.59
1.66

-15

11.4
0.18

-10

1.49
1.55
1.62
1.65
1.69
1.75

PI

TC

35
SHC

PI

TC

40
SHC

PI

1.60
1.62
1.65
1.66
1.70
1.73

4.51
4.67
4.82
4.90
5.13
5.29

3.05
3.09
3.12
3.14
3.19
3.22

1.66
1.68
1.71
1.72
1.76
1.79

4.36
4.52
4.67
4.75
4.98
5.14

2.98
3.02
3.05
3.07
3.12
3.15

1.75
1.78
1.80
1.82
1.85
1.88

4.60
4.76
4.91
4.99
5.22
5.38

3.09
3.13
3.16
3.18
3.23
3.26

TC

PI

TC

PI

6.16
6.13
6.10
6.08
6.07
6.04

1.69
1.75
1.82
1.85
1.89
1.95

6.75
6.72
6.69
6.68
6.66
6.63

1.76
1.83
1.89
1.93
1.96
2.02

12.1

5.28
5.24
5.21
5.20
5.18
5.15

1.58
1.65
1.71
1.74
1.78
1.84

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.
5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables. (Figures out of the tables should not be used for calculation.)
About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D051896D

24

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FTXS50J2V1B + RXS50J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

4.62
5.35
5.58
5.70
6.04
6.27

3.26
3.47
3.58
3.73
3.58
3.47

1.07
1.13
1.13
1.14
1.15
1.15

11.6
0.18

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

4.62
5.12
5.35
5.47
5.81
6.04

3.26
3.34
3.47
3.62
3.48
3.38

1.20
1.23
1.24
1.24
1.25
1.26

4.62
4.89
5.12
5.23
5.58
5.81

3.26
3.23
3.36
3.51
3.39
3.30

1.33
1.34
1.35
1.35
1.36
1.37

PI

TC

PI

1.50
1.53
1.54
1.56
1.56
1.58

6.52
6.32
6.24
6.16
6.12
6.04

1.55
1.58
1.59
1.61
1.61
1.63

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
6
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

3.90
3.70
3.62
3.54
3.50
3.42

1.29
1.33
1.34
1.36
1.36
1.38

4.56
4.36
4.28
4.20
4.16
4.08

1.36
1.39
1.41
1.42
1.43
1.44

-5

5.21
5.01
4.93
4.85
4.81
4.73

1.42
1.45
1.47
1.48
1.49
1.50

3.22
3.18
3.31
3.47
3.35
3.26

TC

35
SHC

PI

TC

40
SHC

PI

1.38
1.39
1.39
1.40
1.40
1.41

4.42
4.65
4.88
5.00
5.35
5.58

3.15
3.11
3.25
3.41
3.30
3.21

1.44
1.45
1.46
1.46
1.47
1.48

4.19
4.42
4.65
4.77
5.11
5.34

3.03
3.00
3.14
3.31
3.20
3.13

1.55
1.56
1.56
1.57
1.58
1.58

12.1

Indoor
EDB
C

-10

4.56
4.79
5.02
5.14
5.49
5.72

PI

6.00
5.80
5.72
5.64
5.60
5.52

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.
2.
3.
4.
5.

6.

Ratings shown are net capacities which include a deduction for indoor fan motor heat.
shows nominal (rated) capacities and power input.
TC, PI and SHC must be calculated by interpolation using the gures in the above tables. (Figures out of the tables should not be used for calculation.)
About SHC which are not mentioned on the table, please calculate them with around values in direct proportion.
Capacities are based on the following conditions.
Corresponding refrigerant piping lenght:
5m
Level difference:
0m
Air ow rate (AFR) and Bypass factor (BF) are tabulated above table.

3D070731

Split - Sky Air Outdoor Unit

25

Outdoor Unit Pair application RXS-J

Capacity tables

4-1

Cooling/Heating Capacity Tables

FVXS50FV1B + RXS50J2V1B

Cooling

AFR
BF

50 Hz 220V-240V

Indoor
EWB
EDB
C
C
14.0
16.0
18.0
19.0
22.0
24.0

20
22
25
27
30
32

Heating

TC

20
SHC

PI

4.53
5.35
5.58
5.70
6.04
6.27

3.19
3.45
3.56
3.71
3.56
3.45

1.13
1.20
1.20
1.21
1.22
1.22

10.7
0.13

TC

25
SHC

PI

TC

Outdoor temperature: (CDB)


30
32
SHC
PI
TC
SHC

4.53
5.12
5.35
5.47
5.81
6.04

3.19
3.33
3.45
3.60
3.46
3.36

1.27
1.31
1.32
1.32
1.33
1.34

4.53
4.89
5.12
5.23
5.58
5.81

3.19
3.21
3.34
3.49
3.37
3.27

1.41
1.43
1.43
1.44
1.45
1.45

PI

TC

PI

1.56
1.60
1.61
1.63
1.64
1.65

6.52
6.32
6.24
6.16
6.03
5.64

1.62
1.65
1.67
1.68
1.68
1.68

AFR

50 Hz 220V-240V

TC

PI

TC

Outdoor temperature: (CWB)


0
0
PI
TC
PI
TC

15.0
20.0
22.0
24.0
25.0
27.0

3.90
3.70
3.62
3.54
3.50
3.42

1.35
1.39
1.40
1.42
1.43
1.44

4.56
4.36
4.28
4.20
4.16
4.08

1.42
1.46
1.47
1.48
1.49
1.51

-5

5.21
5.01
4.93
4.85
4.81
4.73

1.48
1.52
1.54
1.55
1.56
1.57

3.19
3.16
3.29
3.45
3.33
3.24

TC

35
SHC

PI

TC

40
SHC

PI

1.46
1.47
1.48
1.48
1.49
1.50

4.42
4.65
4.88
5.00
5.35
5.58

3.13
3.09
3.23
3.39
3.27
3.19

1.53
1.54
1.55
1.55
1.56
1.57

4.19
4.42
4.65
4.77
5.11
5.34

3.01
2.98
3.12
3.28
3.18
3.10

1.65
1.65
1.66
1.66
1.67
1.68

11.8

Indoor
EDB
C

-10

4.53
4.79
5.02
5.14
5.49
5.72

PI

6.00
5.80
5.72
5.64
5.60
5.52

10

Symbols

AFR:
BF:
EWB:
EDB:
TC:
SHC:
PI:

Air ow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Total capacity
Sensible heat capacity
Power input

(m3/min.)
(C)
(C)
(kW)
(kW)
(kW)

NOTES

1.

2.

Capacities are based on the following conditions.


Corresponding refrigerant piping lenght:
7.5 m
Level difference:
0m
shows nominal (rated) capacities and power input.

3D056339B

26

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Dimensional drawings

5-1

Dimensional Drawings

RXS20-42J2V1B

Minimum space for air passage


Drain outlet
(I.D 15.9 hose for connection)

Handle

Wall height on air outlet side


= less than 1200

4-holes for anchor bolts


(M8 or M10)

Brand name label


Outdoor air thermistor

Manufactures
label

Liquid stop valve


( 6.4CuT)

Wiring inlet

Service port

In case of removing
stop valve cover

Gas stop valve


( 9.5CuT)

3D055546C

RXS50J2V1B

Minimum space for air passage

Drain outlet
(I.D. 15.9 hose for connection)

In case of removing
stop valve cover
4-holes for anchor bolts
(M8 or M10)

Name plate
Wiring inlet

Brand name label

Wall height on air outlet side


= less than 1200

Outdoor air temperature


thermistor

Terminal strip with


earth terminal

Liquid stop valve


( 6.4CuT)
Service port

Gas stop valve


( 12.7CuT)

3D051657Q

Split - Sky Air Outdoor Unit

27

Outdoor Unit Pair application RXS-J

Centre of gravity

6-1

Centre of Gravity

RXS20-35J2V1B

4D056351R
RXS42J2V1B

4D059009E

28

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Centre of gravity

6-1

Centre of Gravity

RXS50J2V1B

the position of foundation bolt

4D051638Q

Split - Sky Air Outdoor Unit

29

Outdoor Unit Pair application RXS-J

Piping diagrams

7-1

Piping Diagrams

RXS20J2V1B
OUTDOOR UNIT

9.5 CuT

7.0 CuT

Heat exchanger

Outdoor temperature thermistor

7.0 CuT
Motor
operated
valve

Heat exchanger
thermistor
6.4 CuT

6.4 CuT

Mufer with
lter

Mufer with
lter

9.5 CuT

Propeller fan

4.0 x ID. 2.0 CuT

7.0 CuT

9.5 CuT

Four way valve


on: heating

Field piping

9.5 CuT

7.9 CuT

6.4 CuT

Mufer with
lter

Liquid stop
valve

Mufer

(6.4 CuT)

7.9 CuT

Discharge pipe
thermistor
9.5 CuT

9.5 CuT

Field piping

Compressor
Gas stop
valve

Mufer Mufer
Accumulator

Refrigerant ow
Cooling
Heating

(9.5 CuT)

3D059587B
RXS25-35J2V1B
OUTDOOR UNIT

9.5 CuT

7.0 CuT

Heat exchanger

Outdoor temperature thermistor

7.0 CuT

4.8 CuT Mufer with

Motor
operated
valve
6.4 CuT
Mufer with
lter

lter

9.5 CuT

Propeller fan

4.0 x ID. 2.0 CuT

Heat exchanger
thermistor
4.8 CuT
6.4 CuT

9.5 CuT

Four way valve


on: heating

Field piping

9.5 CuT

7.9 CuT

6.4 CuT

Mufer with
lter

Liquid stop
valve

Mufer

(6.4 CuT)

7.9 CuT

Discharge pipe
thermistor
9.5 CuT

9.5 CuT

Field piping

Compressor
Mufer Mufer
Accumulator

Gas stop
valve

(9.5 CuT)
Refrigerant ow
Cooling
Heating

30

Split - Sky Air Outdoor Unit

3D059586G

Outdoor Unit Pair application RXS-J

Piping diagrams

7-1

Piping Diagrams

RXS42J2V1B
OUTDOOR UNIT
Heat exchanger

12.7 CuT

7.9 CuT

Outdoor temperature thermistor

7.9 CuT
Heat exchanger
thermistor
4.8 CuT
6.4 CuT
4.8 CuT Mufer with

Motor
operated
valve
6.4 CuT
4.0 x ID. 2.0 CuT

Mufer with
lter

lter

9.5 CuT

Propeller fan
9.5 CuT

Four way valve


on: heating

Field piping

9.5 CuT

7.9 CuT

6.4 CuT

Mufer with
lter

Liquid stop
valve

Mufer

(6.4 CuT)

7.9 CuT

Discharge pipe
thermistor
9.5 CuT

9.5 CuT

Field piping

Compressor
Mufer
Accumulator

Gas stop
valve

(9.5 CuT)

Refrigerant ow
Cooling
Heating

3D059590B

RXS50J2V1B
OUTDOOR UNIT
Heat exchanger

7.9 CuT

Outdoor air temperature


thermistor

7.9 CuT
7.9 CuT
7.9 CuT

Capillary tube 1

7.9 CuT

7.9 CuT 4.0 CuT

7.9 CuT

7.9 CuT 4.0 CuT

7.9 CuT
7.9 CuT

4.0 CuT

Capillary tube 2
Capillary tube 3

Mufer with
lter
6.4 CuT

4.0 CuT

Heat exchanger
thermistor

Refrigerant ow
Cooling

6.4 CuT 6.4 CuT

12.7 CuT

Capillary tube 4

Heating

Motor
operated
valve

Propeller fan

Filter

12.7 CuT

6.4 CuT

12.7 CuT

9.5 CuT
Four way valve
on: heating

Reciever
12.7 CuT

7.9 CuT
Mufer

6.4 CuT

9.5 CuT

7.9 CuT

Field piping

Mufer

Mufer
7.9 CuT
Discharge pipe
thermistor

Liquid stop
valve

12.7 CuT

Compressor

Split - Sky Air Outdoor Unit

(6.4 CuT)

Field piping
Gas stop valve
with service port

(12.7 CuT)

3D051637S

31

Outdoor Unit Pair application RXS-J

Wiring diagrams

8-1

Wiring Diagrams - Single Phase

RXS20-35J2V1B
FIELD WIRING
indoor

outdoor

In case of
cooling only
type
C5, C6 ,C119
:
DB1, DB2, DB3 :
FU1, FU2, FU3
:
IPM1, IPM2
:
L
:
L1
:
L1R
:
M1C
:
M1F
:
MRCW, MR30,
MRM10, MRM20 :
N
:
Q1L
:
PCB1, PCB2,
PCB3
:
S10, S11, S20, S40,
S50, S70, S80, S90,
S100, S110, HL3,

Capacitor
Diode Bridge
Fuse
Instelligent Power Module
Live
Coil
Reactor
Compressor Motor
Fan motor

HN3, X11A, X12A


R1T, R2T, R3T
SA1
SW1
V1, V3, V4
X1M
Y1E

Magnetic Relay
Neutral
Overload Protector
Printed Circuit Board

Y1R
Z1C, Z2C, Z3C

:
:
:
:
:
:
:

Connector
Thermistor
Surge Arrester
Forced operation switch
Varistor
Terminal Strip
Electronic Expansion Valve
Coil
: Reversing solenoide valve coil
: Ferrite Core
: Protective Earth

BLK
BLU
BRN
GRN

:
:
:
:

Black
Blue
Brown
Green

(outdoor)
(discharge)
(condenser)

ORG
RED
WHT
YLW

:
:
:
:

Orange
Red
White
Yellow

NOTES

1.
2.
3.
4.

Refer to the nameplate for power requirements.


Size: Length 105 x width 185.
Refer to purchasing specication AS(Y)303002, unless otherwise specied.
This drawing was drawn on CAD system.
3D065704B

RXS42J2V1B
indoor

Power
supply

(outdoor)
(discharge)
(condenser)

outdoor

FIELD WIRING
C74, C75 ,C94, C95
DB1, DB2, DB3
FU1, FU2, FU3
IPM1
L
L1
L1R
M1C
M1F
MRCW, MRM10,
MRM20, MR30
N
PCB1
Q1L

32

:
:
:
:
:
:
:
:
:

Capacitor
Diode Bridge
Fuse
Instelligent Power Module
Live
Coil
Reactor
Compressor Motor
Fan motor

:
:
:
:

Magnetic Relay
Neutral
Printed Circuit Board
Overload Protector

R1T~R3T
SA1
Q31
V1, V3, V4
X1M
Y1E
Z1C, Z2C, Z3C,
Z4C
S20, S40, S70,
S80, S90
X11A

:
:
:
:
:
:

Thermistor
Surge Arrester
IGBT
Varistor
Terminal Strip
Electronic Expansion Valve
Coil

BLK
BLU
BRN
GRN

:
:
:
:

Black
Blue
Brown
Green

ORG
RED
WHT
YLW

:
:
:
:

Orange
Red
White
Yellow

NOTES

: Ferrite Core
: Connector
: Protective Earth

Split - Sky Air Outdoor Unit

1.
2.
3.

Refer to purchasing specication AS303002, unless otherwise specied.


This drawing was drawn on CAD system.
The electric wiring diagram label is 3P210678-1.
3D059601A

Outdoor Unit Pair application RXS-J

Wiring diagrams

8-1

Wiring Diagrams - Single Phase

RXS50J2V1B

Power
supply

To indoor
unit

sheet
metal
indoor
FIELD WIRING

(outdoor)
(discharge)
(condenser)

LED
outdoor
Z1C~Z5C
X1M, X2M
Y1E

: Ferrite Core
: Terminal Strip
: Electronic Expansion Valve
Coil

V2, V3, V5, V6,


V11
: Varistor
SA2
: Surge Arrester
FU1, FU2, FU3
: Fuse
AC1, AC2
U, V, W, X11A, X12A
E1, E2
HR1, HR2
: Connector
MRM10, MRM20
MRC/W
: Magnetic Relay
R1T~R3T
: Thermistor

S2~S102
Leda
L
N
SW1

:
:
:
:
:

SW4
M1C
M1F
L1R
Q1L
PM1
PCB1, 2
Y1R
Sheet metal

:
:
:
:
:
:
:
:
:

Connector
Pilot lamp
Live
Neutral
Forced operation on/off SW
(SW1)
Localsetting SW (SW4)
Compressor motor
Fan motor
Reactor
Overload protector
Power module
Printed circuit board
Reversing sorenoid valve coil
Terminal strip xed plate

Split - Sky Air Outdoor Unit

NOTES

1.
2.
3.

Refer to purchasing specication AS303002, unless otherwise specied.


This drawing was drawn on CAD system.
The electric wiring diagram label is 3P193830-1.
3D056095D

33

Outdoor Unit Pair application RXS-J

Sound data

9-1

Sound Pressure Spectrum

RXS20-25J2V1B

Octave band sound pressure level (0 dB = 0.0002 bar)

Heating

Octave band sound pressure level (0 dB = 0.0002 bar)

Cooling

Approximate
threshold hearing
for continuous
noise

Approximate
threshold hearing
for continuous
noise

Octave band center frequency - IEC (Hz)

Octave band center frequency - IEC (Hz)

NOTES

Scale
1
2
3
4

5
6

Over All (dB):


(B,G,N is already rectified)
Measuring place: measure in anechoic room.
Operating conditions: Power source 220~240V, 50Hz
Location of microphone.
JISC9612
The operation noise
measuring method is in
accordance with JISC9612
Cooling
Operation noise differs with operation and ambient conditions.

50Hz
220-240V
46

NOTES

Scale
1
2
3
4

Over All (dB):


(B,G,N is already rectified)
Measuring place: measure in anechoic room.
Operating conditions: Power source 220~240V, 50Hz
Location of microphone.
JISC9612
The operation noise
measuring method is in
accordance with JISC9612
Heating

50Hz
220-240V
47

3D059599B
RXS35J2V1B

Octave band sound pressure level (0 dB = 0.0002 bar)

Heating

Octave band sound pressure level (0 dB = 0.0002 bar)

Cooling

Approximate
threshold hearing
for continuous
noise

Approximate
threshold hearing
for continuous
noise

Octave band center frequency - IEC (Hz)

Octave band center frequency - IEC (Hz)

NOTES

Scale
1
2
3
4

5
6

Over All (dB):


(B,G,N is already rectified)
Measuring place: measure in anechoic room.
Operating conditions: Power source 220~240V, 50Hz
Location of microphone.
JISC9612
The operation noise
measuring method is in
accordance with JISC9612
Cooling
Operation noise differs with operation and ambient conditions.

50Hz
220-240V
48

NOTES

Scale
1
2
3
4

Over All (dB):


(B,G,N is already rectified)
Measuring place: measure in anechoic room.
Operating conditions: Power source 220~240V, 50Hz
Location of microphone.
JISC9612
The operation noise
measuring method is in
accordance with JISC9612
Heating

50Hz
220-240V
48

3D059593D

34

Split - Sky Air Outdoor Unit

Outdoor Unit Pair application RXS-J

Sound data

9-1

Sound Pressure Spectrum

RXS42J2V1B

Octave band sound pressure level (0 dB = 0.0002 bar)

Heating

Octave band sound pressure level (0 dB = 0.0002 bar)

Cooling

Approximate
threshold hearing
for continuous
noise

Approximate
threshold hearing
for continuous
noise

Octave band center frequency - IEC (Hz)

Octave band center frequency - IEC (Hz)

NOTES

Scale
1
2
3
4

5
6

Over All (dB):


(B,G,N is already rectified)
Measuring place: measure in anechoic room.
Operating conditions: Power source 220~240V, 50Hz
Location of microphone.
JISC9612
The operation noise
measuring method is in
accordance with JISC9612
Cooling
Operation noise differs with operation and ambient conditions.

50Hz
220-240V (H)
48

NOTES

Scale
1
2
3
4

Over All (dB):


(B,G,N is already rectified)
Measuring place: measure in anechoic room.
Operating conditions: Power source 220~240V, 50Hz
Location of microphone.
JISC9612
The operation noise
measuring method is in
accordance with JISC9612
Heating

50Hz
220-240V (H)
48

3D059597B
RXS50J2V1B

Octave band sound pressure level (0 dB = 0.0002 bar)

Heating

Octave band sound pressure level (0 dB = 0.0002 bar)

Cooling

Approximate
threshold hearing
for continuous
noise

Approximate
threshold hearing
for continuous
noise

Octave band center frequency - IEC (Hz)

Octave band center frequency - IEC (Hz)

NOTES

Scale
1
2
3
4

5
6

Over All (dB):


(B,G,N is already rectified)
Measuring place: measure in an echoic room.
Operating conditions: Power source 220~240V, 50Hz
Location of microphone.
JISC9612
The operation noise
measuring method is in
accordance with JISC9612
Cooling
50 Hz 220-240V
Operation noise differs with operation and ambient conditions.

50Hz
220-240V
48

NOTES

Scale
1
2
3

Over All (dB):


(B,G,N is already rectified)
Operating conditions: Power source 220~240V, 50Hz
Heating
50 Hz 220-240V

50Hz
220-240V
48

3D059740B

Split - Sky Air Outdoor Unit

35

Outdoor Unit Pair application RXS-J

10

Operation range

10 - 1 Operation Range
RXS20-50J2V1B

Continuous operation

Pull-down period

Outdoor temperature (CWB)

Heating

Continuous operation

Outdoor temperature (CWB)

Cooling

(-15CDB)

Indoor temperature (CDB)

Indoor temperature (CDB)

NOTES

The graphs are based on the following conditions.


Equivalent piping length
7.5 m
Level difference
0m
Air ow rate
High

36

Split - Sky Air Outdoor Unit

3D028318Q

The present publication is drawn up by way of information only and does not constitute an offer binding
upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its
knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for
particular purpose of its content and the products and services presented therein. Specifications are subject
to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect
damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All
content is copyrighted by Daikin Europe N.V.

Daikin products are distributed by:

Daikin Europe N.V. is participating in the EUROVENT


Certification Programme. Products are as listed in the
EUROVENT Directory of Certified Products. Multi units are
Eurovent certified for combinations up to 2 indoor units

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

EEDEN11-100 CD 02/11 Copyright Daikin


The present publication supersedes EEDEN10-100
Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern
for the environment is set in the EMAS and ISO 14001 systems.
Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Daikins unique position as a manufacturer of air


conditioning equipment, compressors and refrigerants
has led to its close involvement in environmental issues.
For several years Daikin has had the intention to become
a leader in the provision of products that have limited
impact on the environment. This challenge demands the
eco design and development of a wide range of products
and an energy management system, resulting in energy
conservation and a reduction of waste.