TECHNICAL SPECIFICATIONS
A. GENERAL CHARACTERISTICS Design standars Transformer type Service Condition Type of oil Number of phase Frequency B. TECHNICAL SPECIFICATION Capacity Primary Voltage Secondary Voltage Vector Group Cooling Temperature Rise - Oil - Winding No load losses at nominal voltage On load losses at principal tapping Impedance voltage Off load current at nominal voltage Temperature Insulation Class Noise Tapping value C. INSULATION CLASS OF THE WINDINGS Highest system voltage (kV) Impulse test voltage (kV) Applied test voltage (kV) D. EFFICIENCY AND VOLTAGE REGULATION : : : : : : : : : : : : : : : : : : : : : : : IEC 76 Oil Filled With Conservator Indoor Mineral Oil 3 Phase 50 Hz 4000 / 5000 kVA 20 kV 0.4 kV Dyn5 ONAN / ONAF 60 oC oC 65 5300 Watts 38000 Watts (at ONAN) 7.5 % (at ONAN) 1.7 % A dB 70 +2X2.5%; -5X2.5% Primary Secondary 24 125 50 1.1 0 3

TO BE INFORMED
E. APPROXIMATE WEIGHTS AND DIMENSION Total length Total width Total height Weight of oil Weight of core and winding Total weight Approximate Drawing No. Painting Colour : : : : : : : : 2,800 2,500 2,850 2,100 4,100 10,700 mm mm mm kg kg kg

Light Grey RAL 7032

The above dimensions and masses are approximate and provided to give a general description of our proposed transformer.
Revision Date Est. Chk App. Original 19-May-11 Wid

Client / Project:
No : : D 10913 1 / 2

Private

Page

Jakarta - Indonesia

TECHNICAL SPECIFICATIONS
F. ACCESSORIES - Name Plate and Rating Plate - HV and LV Porcelain Bushings - Off Circuit Tap Changer - Oil Filling Valve - Oil Draining Valve and Sampling - Lifting Lugs - Grounding Terminal - Skid Base - Pressure Relief Device Without Contact - DGPT 2 Relay - Conservator + Dehydrating Breather - Fins Type Radiator - Cooling Fans - Control Box for Wiring G. DEVIATIONS / EXCEPTIONS - None

H. NOTES - None

I. LIST OF TEST Routine Test : - Measurement of the resistance value and checking of polarities - Measurement of the ratio on all taps - No load test for measurement of the no load loss and no load current - Short circuit test for determination of the on load loss and impedance - Applied voltage test - Induced voltage test Type test : - Temperature rise test - Full wave impuls test ( 1.2 / 50 us ) Yes

No

Tests other than the above mentioned list needs further confirmation
Revision Date Est. Chk App. Original 19-May-11 Wid

Client / Project:
No : : D 10913 2 / 2

Private

: :

: : : : : :

Page