This could result in an incorrect parsing of data of this event. Please locate the correct parse file for the current firmware version and uploa d it using the Send Parse File button on the Controller Event page. The correct parse file is: : HSV200_event_CR0ECA_6110.txt It should be installed in the directory: C:\Program Files\Hewlett-Packard\Sanwo rks\Element Manager for StorageWorks HSV\events\ ******************************************************************************** ********** Event header details: Event sequence number: 496106 Flags: Time_set Time_synched Event rev: 2 Event size: 152 Software version: 6110 Base level: CR0ECA Ctlr model: HSV200 Ctlr handle: 0000-7-8-500508B4-00070F87-00000000-00000000 Report time: 4 Mar, 2012 19:01:42.560317 Location: 0x0016415C Event code: Type: 13 Cac: 47 Num: 03 Scid: 06 Event description: 0x06034713 Severity: Warning -- not failed but attention reco mmended or required. An exchange sent to a physical disk drive or another HSV200 controller via the mirror port or a Fibre Channel port has timed out. Information packet rev: 05 Information packet type: 13 Information packet size: 0058 Software component: Fibre Channel Services Corrective action: Dropped frames are potential indications of an impending Fibr e Channel port or physical disk drive failure when they occur excessively. If fr ame drop becomes excessive, the indicated Fibre Channel port or the indicated ph ysical disk drive will be placed in the inoperative state. This is a preemptive action warning, no immediate action is necessary. Event structure details: Information packet descriptor: EIP13 - Fibre Channel Services Physical Disk Drive/Mirror Port/Drive Enclosure E nvironmental Monitoring Unit Error summary. Summary of errors encountered while attempting to access a physical disk drive, the mirror port, or a Drive Enclosure Environmental Monitoring Unit. Structure: Event Structure: flags time_set: TRUE - Time has been set on this HSV200 controller time_synched: TRUE - Time has been synchronized with all HSV200 controllers in the Storage System seq_reset: FALSE - Event sequence number reset occurred outofsequence: FALSE - Event reported out of sequence due to Final Event Blo ck reconciliation or lost host event requeued: FALSE - Event requeued following restart or resynchronization labcode: FALSE - Event reported using LAB code prictrlr: FALSE - Event reported by primary HSV200 controller (Note: Not val id until Storage System primary HSV200 controller is elected) spsctrlr: FALSE - Single power supply HSV200 controller End of structure

revision: 2 [0x02] - Structure revision number count: 152 [0x0098] - Event specific information size in bytes sequence_number: 496106 [0x000791EA] - Sequence number assigned to the event sw_version: 6110 - HSV200 controller software version number string baselevel_id: CR0ECA - HSV200 controller baselevel build string ctrlr_model_id: HSV200 - HSV200 controller model string reporting_ctrlr: 0000-7-8-500508B4-00070F87-00000000-00000000 - Storage System Management Interface Handle of HSV200 controller that reported the event report_time: 4 Mar, 2012 19:01:42.560317 - Time event was reported report_location: 1458524 [0x0016415C] - Location of event report call Structure: header Union: u Structure: ec eiptype: 19 [0x13] - Event Information Packet Type Code cac: 71 [0x47] - Corrective Action Code evnum: 3 [0x03] - Event Number scid: 6 [0x06] - HSV200 Controller Software Component Identification End of structure End of union section value: 100878099 [0x06034713] - Event Code Value End of union End of union revision: 5 [0x05] - Packet revision number type: 19 [0x13] - Packet type count: 88 [0x0058] - Number of bytes in packet End of structure device: 14-00-00-20-5B-86-FE-C3-00-00-00-00-00-00-00-00 - UUID of the physical disk drive, HSV200 controller, or Drive Enclosure Environmental Monitoring Unit associated with the event cerp_id: DP-1A - HSV200 controller enclosure rear panel Fibre Channel port attached to the physical disk drive or mirror port al_pa: 74 [0x0000004A] - AL_PA of the physical disk drive or the mirror port dencl_num: 2 [0x0002] - Enclosure where the physical disk drive is located port: 0 [0x0000] - HSV200 controller internal Fibre Channel port number attach ed to the physical disk drive or mirror port rack_num: 0 [0x0000] - Rack where the physical disk drive is located bay: 6 [0x0006] - Enclosure bay where the physical disk drive is located fed_class: 16777264 [0x01000030] - Fibre Channel Exchange Descriptor class num_times: 1 [0x00000001] - Number of occurrences of the error. Structure: enclosures[1] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[0] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[3] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[2] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[5] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[4]

rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[7] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[6] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[9] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure Structure: enclosures[8] rack_num: 0 [0x00] - Rack were enclosure is located dencl_num: 99 [0x63] - Enclosure number End of structure missing_cerp_id: - HSV200 controller enclosure rear panel Fibre Chann el port that cannot connect to physical disk drive or mirror port bypassa: 32768 [0x8000] - Mask showing bypass state for each slot in a shelf missing_port: 0 [0x0000] - HSV200 controller internal Fibre Channel port numbe r that cannont connect to the physical disk drive or mirror port switch_type: 0 [0x0000] - Used to represent the type of switch detected (SES o r non-SES compliant) bypassb: 32768 [0x8000] - Mask showing bypass state for each slot in a shelf End of structure Salient data: Event: Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV200 controller via the mir ror port or a Fibre Channel port has timed out. Action: Dropped frames are potential indications of an impending Fibre Channel p ort or physical disk drive failure when they occur excessively. If frame drop be comes excessive, the indicated Fibre Channel port or the indicated physical disk drive will be placed in the inoperative state. This is a preemptive action warn ing, no immediate action is necessary.

S-ar putea să vă placă și