The T-Panel System

Material Recycled Aluminum Alloy 6063 Temper - T5 Sizes. Sold in 5 or 10 panel extrusions. f 8 Eave T-Panel (for eaves up to 12 deep) f 12 Eave T-Panel (for eaves up to 18 deep) f 18 Eave T-Panel (for eaves up to 24 deep) f Valley T-Panel for valleys, chimneys, crickets etc f Utility T-Panel a larger version of the valley panel Components Aluminum Alloy Snap Loc Top, Aluminum Alloy Base Panel, Aluminum Alloy Transition Panel Colors 7 Standard Powder Coating Colors are available Heat Source the 8 Eave, 12 Eave, Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18 Eave Panel System will utilize three feet of cable per foot. Products are designed for 11mm or 14 mm commercial grade heat cables, mineral insulated (MI) cable or 3/8 Radiant PEX tubing *Recommended Commercial GradeSelf Regulating Heat Cable (GM-X2 12 Watt per foot in 100-130 VAC or 208-277 VAC). Optional Items Ambient and/or Moisture Sensor Controllers, Self regulating heat trace for gutters and downspouts Electrical Requirements N.E.C. 426-28 requires 30 mA Ground Fault circuit protection for snow and ice melting applications Specifications Thermal Technologies T-Panels simple integrated drip edge and color matched cover is designed to eliminate icicles, ice dams, and snow at the roofs edge. Thermal Technologies innovative roof snow and ice elimination systems are attractive and cost effective. They ensure that the buildings owner will not have the frustration, property damage, and costs associated with water damage, caused by the inability of the buildings roof to properly drain water during winter months. Thermal Technologies revolutionary roof de-icing systems will extend your roof life and reduce the destructive situations that snow and ice can inflict on any roof. Mounting Eave panels are installed with sealant & roofing screws. Screws and sealant may be replaced by 3M VHB Adhesive Tape, TAMPRO Flashing Cement or Rainbuster 14000 Silicone. The lip of the eave panel fits below the shingles, cedar shake, corrugated metal roof panels, or slate roof panels, facilitation proper moisture drainage off the roof structure. T-Panel eave panels fit below shingles, provide a drip edge into the gutter, and eliminate ice & snow in the roofs freeze zone.

Aluminum Extrusion Profiles (6 lengths) 8 Eave T-Panel for eaves up to 12 deep)

12 Eave T-Panel for eaves up to 18 deep

18 Eave T-Panel for eaves up to 24 deep

Valley T-Panel for Valleys

Utility T-Panel for Chimneys, Valleys & Below Stairs

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


Selecting a panel length The Eave Panel melts ice in the freeze zone at the roofs eave. The Valley Panel melts ice in the freeze zone at the roofs valley.

l ane 2P T 12

Panel heats 70% of valley length

18 Deep Eave The size of the eave freeze area determines the size of the eave panel. f 8 Eave T-Panel (for eaves up to 12 deep) f 12 Eave T-Panel (for eaves up to 18 deep) f 18 Eave T-Panel (for eaves up to 24 deep)

The lower 70% length of valleys is the typical freeze zone. This area needs heat protection in cold climates.

f Valley T-Panel (for valleys, chimneys, crickets etc) f Utility T-Panel (a larger version of the valley panel)

Number of feet of heat cable allowed per circuit breaker the 8 Eave, 12 Eave, Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18 Eave Panel System will utilize three feet of cable per foot. Pay strict attention to the ambient start up temperature, circuit size and load requirement. Start-up 15 A Circuit 20 A Circuit 30 A Circuit temperature Breaker Breaker Breaker @ 120 volts 32F (0C) 100 (30) 135 (41) 200 (61m) 20F (7C) 95 (29m) 125 (38m) 185 (56m) 0F (18C) 80 (24m) 100 (30m) 155 (47m) @ 208 volts 32F (0C) 190 (58) 250 (76) 380 (116m) 20F (7C) 0F (18C) 32F (0C) 20F (7C) 0F (18C) 32F (0C) 20F (7C) 0F (18C) 180 (55m) 145 (44m) 200 (61m) 190 (58m) 155 (47m) 215 (66m) 200 (61m) 165 (50m) 235 (72m) 195 (59m) 265 (81m) 250 (76m) 205 (62m) 290 (88m) 265 (81m) 225 (69m) 355 (108m) 290 (88m) 400 (122m) 370 (113m) 305 (93m) 415 (126m) 400 (122m) 330 (101m)

40 A* Circuit Breaker 200 (61m)* 200 (61m)* 380 (116m)* 380 (116m)* 400 (122m)* 400 (122m)* 415 (126m)* 415 (126m)*

@ 240 volts

@ 277 volts

* Only FTC-P power connection kits may be used with 40-A circuits. Bus Wires 16 AWG nickel-plated copper Braid/Outer 14807 Heritage Crest Way, Suite B Bluffdale, UT 84065 1-866-635-8123 www.thermal1.com

The T-Panel System


How to select the correct heat channel All of our products can incorporate different types of heat sources, such as, 14 mm self regulating heat cable, Mineral Insulated Cable and Hydronic / Radiant Tubing. Thermal Technologies technically advanced aluminum alloy extrusions are manufactured with specific sized channels for specific sized heat cables. Note: All products manufactured by Thermal Technologies incorporate the same or similar superior internal configuration as the systems shown here. The same installation parameters with regards to channels vs. heat source apply to all of the other panel system products manufactured and sold by Thermal Technologies. This picture shows the correct cable in the correct channel. The separation between the snap-loc top and base unit are designed and manufactured within tight tolerances. This separation eliminates the characteristics of a cover panel supported by the base panel, yet enables direct heat transfer or direct thermal conductivity to occur between the heat source and the base and top units. No other product designed, manufactured or sold compares to the exceptional quality and outstanding performance of the products offered by Thermal Technologies. If multiple sized channels are available, only fill one size on each side of the panel with the correct cable or tubing.

3/8 pex Tubing

14mm cable

Ice Stop cables are designed to be installed within the larger of the two channels. This channel is sized for approximately 14mm heat cable. 3/8 in. PEX tubing or similar sized radiant tubings are designed to be installed within the round channel. This channel is sized for approximately 3/8 inch radiant PEX tubing.

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


Drawings 8 Eave Panel for eaves up to 12 deep
2.44
0.73

2.50

7.50

12 Eave Panel for eaves up to 18 deep


6.40
3.70
1.20 0.38

0.38

2.40 13.00

18 Eave Panel for eaves up to 24 deep

1.20

0.70
0.38 0.38

2.40 19.34

3 Valley Panel for Valleys


0.73

2.86

6 Utility Panel for valleys, chimneys, crickets etc

0.70
6.08
14807 Heritage Crest Way, Suite B Bluffdale, UT 84065 1-866-635-8123 www.thermal1.com

0.08

12.5

3.70

0.08

The T-Panel System


3 Valley Panel for valleys, chimneys, crickets etc

0.73

2.86

Panel Mounting

Panel Mating

Sold

in 5

or 10

leng

ths

0.50

Extension Joint Cap (XJ)

5.00

Screw Hole Placement Every 2 (24)

Leave 0.50 between panels. Cover With Extension Joint Cap (XJ)

Heat Cable

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


6 Utility Panel for valleys, chimneys, crickets etc

0.70
6.08

0.50

Leave 0.50 between panels. Cover With Extension Joint Cap (XJ)

Extension Joint Cap (XJ)

5.00

Loop cable at end cap

End Cap

5.00

Sold

in 5 or

10 le

ngth

Screw hole placement every 24 on center

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


Placement of Ice & Water Shield, Flashing and Roofing Materials

Angle Mounting
Roo ng material (shingles, panels, etc) Heat Cable Ice and water shield

Utility Panel

Roof

Valley Flashing

Supp

ort

Surface Mounting
Flashing Roo ng material (shingles, panels, etc)

Ice and water shield

Roof Support

Surface Mounting for Rubber Roof


Manufacturers recommended adhesive or cement Non-slip powder coat Ice-stop Heat Cable

Roo ng Material

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


Example Cable Run for Utility Panels

Expansion Joint Cap (XJ)

3.00 Gap Between Panels for Cable Exit Junction, Covered by Expansion Joint Cap (XJ)
rce Power Sou x Control Bo

Expansion Joint Cap (XJ)

Heat Cable
To Gutters, or other panels

0.50 Gap Between Panels, Covered by Expansion Joint Cap (XJ)

End Termination
rce Power Sou x Control Bo

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


Double-Valley Panel

3.00 6.00

3.00 2.00

12.00

6.00 (7

2.00)

Screw hole placement every 24 on center

Roo ng material (shingles, panels, etc) Double Valley Panel Assembly

Ice & Water Sheild

Roo n g Mate rial

rial g Mate Roo n

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


Flat Roof Panel
6.7
0.726

5.8

6.7

2.297 19.2

Each addition of a center panel adds 5.8

Sold

in 5

or 10

leng

ths

Screw Hole Placement Every 2 (24)

Heat Cable

Insert Panels to increase length


Each addition of a center panel adds 5.8

14807 Heritage Crest Way, Suite B Bluffdale, UT 84065

1-866-635-8123 www.thermal1.com

The T-Panel System


Flat Roof Panel Installation

Surface Mounting
Roo ng material (shingles, panels, etc) Flashing

Ice and water shield

Roof Support

Surface Mounting for Rubber Roof


Manufacturers recommended adhesive or cement Non-slip powder coat Ice-stop Heat Cable