Documente Academic
Documente Profesional
Documente Cultură
Material Recycled Aluminum Alloy 6063 Temper - T5 Sizes. Sold in 5 or 10 panel extrusions. f 8 Eave T-Panel (for eaves up to 12 deep) f 12 Eave T-Panel (for eaves up to 18 deep) f 18 Eave T-Panel (for eaves up to 24 deep) f Valley T-Panel for valleys, chimneys, crickets etc f Utility T-Panel a larger version of the valley panel Components Aluminum Alloy Snap Loc Top, Aluminum Alloy Base Panel, Aluminum Alloy Transition Panel Colors 7 Standard Powder Coating Colors are available Heat Source the 8 Eave, 12 Eave, Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18 Eave Panel System will utilize three feet of cable per foot. Products are designed for 11mm or 14 mm commercial grade heat cables, mineral insulated (MI) cable or 3/8 Radiant PEX tubing *Recommended Commercial GradeSelf Regulating Heat Cable (GM-X2 12 Watt per foot in 100-130 VAC or 208-277 VAC). Optional Items Ambient and/or Moisture Sensor Controllers, Self regulating heat trace for gutters and downspouts Electrical Requirements N.E.C. 426-28 requires 30 mA Ground Fault circuit protection for snow and ice melting applications Specifications Thermal Technologies T-Panels simple integrated drip edge and color matched cover is designed to eliminate icicles, ice dams, and snow at the roofs edge. Thermal Technologies innovative roof snow and ice elimination systems are attractive and cost effective. They ensure that the buildings owner will not have the frustration, property damage, and costs associated with water damage, caused by the inability of the buildings roof to properly drain water during winter months. Thermal Technologies revolutionary roof de-icing systems will extend your roof life and reduce the destructive situations that snow and ice can inflict on any roof. Mounting Eave panels are installed with sealant & roofing screws. Screws and sealant may be replaced by 3M VHB Adhesive Tape, TAMPRO Flashing Cement or Rainbuster 14000 Silicone. The lip of the eave panel fits below the shingles, cedar shake, corrugated metal roof panels, or slate roof panels, facilitation proper moisture drainage off the roof structure. T-Panel eave panels fit below shingles, provide a drip edge into the gutter, and eliminate ice & snow in the roofs freeze zone.
1-866-635-8123 www.thermal1.com
l ane 2P T 12
18 Deep Eave The size of the eave freeze area determines the size of the eave panel. f 8 Eave T-Panel (for eaves up to 12 deep) f 12 Eave T-Panel (for eaves up to 18 deep) f 18 Eave T-Panel (for eaves up to 24 deep)
The lower 70% length of valleys is the typical freeze zone. This area needs heat protection in cold climates.
f Valley T-Panel (for valleys, chimneys, crickets etc) f Utility T-Panel (a larger version of the valley panel)
Number of feet of heat cable allowed per circuit breaker the 8 Eave, 12 Eave, Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18 Eave Panel System will utilize three feet of cable per foot. Pay strict attention to the ambient start up temperature, circuit size and load requirement. Start-up 15 A Circuit 20 A Circuit 30 A Circuit temperature Breaker Breaker Breaker @ 120 volts 32F (0C) 100 (30) 135 (41) 200 (61m) 20F (7C) 95 (29m) 125 (38m) 185 (56m) 0F (18C) 80 (24m) 100 (30m) 155 (47m) @ 208 volts 32F (0C) 190 (58) 250 (76) 380 (116m) 20F (7C) 0F (18C) 32F (0C) 20F (7C) 0F (18C) 32F (0C) 20F (7C) 0F (18C) 180 (55m) 145 (44m) 200 (61m) 190 (58m) 155 (47m) 215 (66m) 200 (61m) 165 (50m) 235 (72m) 195 (59m) 265 (81m) 250 (76m) 205 (62m) 290 (88m) 265 (81m) 225 (69m) 355 (108m) 290 (88m) 400 (122m) 370 (113m) 305 (93m) 415 (126m) 400 (122m) 330 (101m)
40 A* Circuit Breaker 200 (61m)* 200 (61m)* 380 (116m)* 380 (116m)* 400 (122m)* 400 (122m)* 415 (126m)* 415 (126m)*
@ 240 volts
@ 277 volts
* Only FTC-P power connection kits may be used with 40-A circuits. Bus Wires 16 AWG nickel-plated copper Braid/Outer 14807 Heritage Crest Way, Suite B Bluffdale, UT 84065 1-866-635-8123 www.thermal1.com
14mm cable
Ice Stop cables are designed to be installed within the larger of the two channels. This channel is sized for approximately 14mm heat cable. 3/8 in. PEX tubing or similar sized radiant tubings are designed to be installed within the round channel. This channel is sized for approximately 3/8 inch radiant PEX tubing.
1-866-635-8123 www.thermal1.com
2.50
7.50
0.38
2.40 13.00
1.20
0.70
0.38 0.38
2.40 19.34
2.86
0.70
6.08
14807 Heritage Crest Way, Suite B Bluffdale, UT 84065 1-866-635-8123 www.thermal1.com
0.08
12.5
3.70
0.08
0.73
2.86
Panel Mounting
Panel Mating
Sold
in 5
or 10
leng
ths
0.50
5.00
Leave 0.50 between panels. Cover With Extension Joint Cap (XJ)
Heat Cable
1-866-635-8123 www.thermal1.com
0.70
6.08
0.50
Leave 0.50 between panels. Cover With Extension Joint Cap (XJ)
5.00
End Cap
5.00
Sold
in 5 or
10 le
ngth
1-866-635-8123 www.thermal1.com
Angle Mounting
Roo ng material (shingles, panels, etc) Heat Cable Ice and water shield
Utility Panel
Roof
Valley Flashing
Supp
ort
Surface Mounting
Flashing Roo ng material (shingles, panels, etc)
Roof Support
Roo ng Material
1-866-635-8123 www.thermal1.com
3.00 Gap Between Panels for Cable Exit Junction, Covered by Expansion Joint Cap (XJ)
rce Power Sou x Control Bo
Heat Cable
To Gutters, or other panels
End Termination
rce Power Sou x Control Bo
1-866-635-8123 www.thermal1.com
3.00 6.00
3.00 2.00
12.00
6.00 (7
2.00)
1-866-635-8123 www.thermal1.com
5.8
6.7
2.297 19.2
Sold
in 5
or 10
leng
ths
Heat Cable
1-866-635-8123 www.thermal1.com
Surface Mounting
Roo ng material (shingles, panels, etc) Flashing
Roof Support
Roo ng Material
1-866-635-8123 www.thermal1.com