Optimux-108L
Fiber Multiplexer for 4E1 and Ethernet
Version 2.0
Optimux-108L
Fiber Multiplexer for 4E1 and Ethernet
Version 2.0
International Headquarters RAD Data Communications Ltd. 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel: 972-3-6458181 Fax: 972-3-6498250, 6474436 E-mail: market@rad.com
North America Headquarters RAD Data Communications Inc. 900 Corporate Drive Mahwah, NJ 07430, USA Tel: (201) 5291100, Toll free: 1-800-4447234 Fax: (201) 5295777 E-mail: market@rad.com
Limited Warranty
RAD warrants to DISTRIBUTOR that the hardware in the Optimux-108L to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the appropriate corrective action: a) supply a replacement part, or b) request return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location. In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs. RAD shall be released from all obligations under its warranty in the event that the equipment has been subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were made by persons other than RAD's own authorized service personnel, unless such repairs by others were made with the written consent of RAD. The above warranty is in lieu of all other warranties, expressed or implied. There are no warranties which extend beyond the face hereof, including, but not limited to, warranties of merchantability and fitness for a particular purpose, and in no event shall RAD be liable for consequential damages. RAD shall not be liable to any person for any special or indirect damages, including, but not limited to, lost profits from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, repair, maintenance or use of the Optimux-108L, and in no event shall RAD's liability exceed the purchase price of the Optimux-108L. DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating to Optimux-108L and for ensuring that replacements and other adjustments required in connection with the said warranties are satisfactory. Software components in the Optimux-108L are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of use, interruption of business or indirect, special, incidental or consequential damages of any kind. In spite of the above RAD shall do its best to provide error-free software products and shall offer free Software updates during the warranty period under this Agreement. RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this Agreement and the Optimux-108L shall not exceed the sum paid to RAD for the purchase of the Optimux-108L. In no event shall RAD be liable for any indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the possibility of such damages. This Agreement shall be construed and governed in accordance with the laws of the State of Israel.
Product Disposal
To facilitate the reuse, recycling and other forms of recovery of waste equipment in protecting the environment, the owner of this RAD product is required to refrain from disposing of this product as unsorted municipal waste at the end of its life cycle. Upon termination of the units use, customers should provide for its collection for reuse, recycling or other form of environmentally conscientious disposal.
Safety Symbols
This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.
Warning
Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines.
Protective ground: the marked lug or terminal should be connected to the building protective ground bus.
Warning
Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions: Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter. Do not attempt to adjust the laser drive current. Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam. The use of optical devices with the equipment will increase eye hazard.
Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure. ATTENTION: The laser beam may be invisible! In some cases, the users may insert their own SFP laser transceivers into the product. Users are alerted that RAD cannot be held responsible for any damage that may result if non-compliant transceivers are used. In particular, users are warned to use only agency approved products that comply with the local laser safety regulations for Class 1 laser products. Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user.
Connecting AC Mains
Make sure that the electrical installation complies with local codes. Always connect the AC plug to a wall socket with a protective ground. The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A (20A for USA and Canada). The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A (40A for USA and Canada). Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation. In cases when the power distribution system is IT type, the switch must disconnect both poles simultaneously.
Connecting DC Power
Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded. Due to the high current capability of DC power systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards. Make sure that the DC power supply is electrically isolated from any AC source and that the installation complies with the local codes.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A (20A for USA and Canada). The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A (40A for USA and Canada). Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation. If the DC power supply is floating, the switch must disconnect both poles simultaneously.
Ports V.11, V.28, V.35, V.36, RS-530, X.21, 10 BaseT, 100 BaseT, Unbalanced E1, E2, E3, STM, DS-2, DS-3, S-Interface ISDN, Analog voice E&M xDSL (without feeding voltage), Balanced E1, T1, Sub E1/T1
Safety Status SELV Safety Extra Low Voltage: Ports which do not present a safety hazard. Usually up to 30 VAC or 60 VDC.
TNV-1 Telecommunication Network Voltage-1: Ports whose normal operating voltage is within the limits of SELV, on which overvoltages from telecommunications networks are possible. TNV-2 Telecommunication Network Voltage-2: Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are not possible. These ports are not permitted to be directly connected to external telephone and data lines. TNV-3 Telecommunication Network Voltage-3: Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are possible.
FXO (Foreign Exchange Office), xDSL (with feeding voltage), U-Interface ISDN
Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a qualified safety engineer. Always make sure that the equipment is grounded before connecting telecommunication cables. Do not disconnect the ground connection before disconnecting all telecommunications cables. Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms.
When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The grounding and bonding of the ground connections should comply with the local codes. The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors.
Caution
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords.
Attention
Pour rduire les risques sincendie, utiliser seulement des conducteurs de tlcommunications 26 AWG ou de section suprieure.
Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions. Do not attempt to tamper with any carrier-provided equipment or connection hardware.
Avertissement
Achtung
Franais
Avertissement
Symboles de scurit
Ce symbole peut apparaitre sur l'quipement ou dans le texte. Il indique des risques potentiels de scurit pour l'oprateur ou le personnel de service, quant l'opration du produit ou sa maintenance.
Danger de choc lectrique ! Evitez tout contact avec la surface marque tant que le produit est sous tension ou connect des lignes externes de tlcommunications.
Mise la terre de protection : la cosse ou la borne marque devrait tre connecte la prise de terre de protection du btiment.
Avant la mise en marche de l'quipement, assurez-vous que le cble de fibre optique est intact et qu'il est connect au transmetteur. Ne tentez pas d'ajuster le courant de la commande laser. N'utilisez pas des cbles ou connecteurs de fibre optique casss ou sans terminaison et n'observez pas directement un rayon laser. L'usage de priphriques optiques avec l'quipement augmentera le risque pour les yeux.
L'usage de contrles, ajustages ou procdures autres que celles spcifies ici pourrait rsulter en une dangereuse exposition aux radiations. ATTENTION : Le rayon laser peut tre invisible ! Les utilisateurs pourront, dans certains cas, insrer leurs propres metteurs-rcepteurs Laser SFP dans le produit. Les utilisateurs sont avertis que RAD ne pourra pas tre tenue responsable de tout dommage pouvant rsulter de l'utilisation d'metteurs-rcepteurs non conformes. Plus particulirement, les utilisateurs sont avertis de n'utiliser que des produits approuvs par l'agence et conformes la rglementation locale de scurit laser pour les produits laser de classe 1. Respectez toujours les prcautions standards de scurit durant l'installation, l'opration et la maintenance de ce produit. Seul le personnel de service qualifi et autoris devrait effectuer l'ajustage, la maintenance ou les rparations de ce produit. Aucune opration d'installation, d'ajustage, de maintenance ou de rparation ne devrait tre effectue par l'oprateur ou l'utilisateur.
Franais
Certains produits peuvent tre quips d'une diode laser. Dans de tels cas, une tiquette indiquant la classe laser ainsi que d'autres avertissements, le cas chant, sera jointe prs du transmetteur optique. Le symbole d'avertissement laser peut aussi tre joint. Avertissement Veuillez observer les prcautions suivantes :
Franais
Connexion d'alimentation CC
Sauf s'il en est autrement spcifi dans le manuel, l'entre CC de l'quipement est flottante par rapport la mise la terre. Tout ple doit tre mis la terre en externe. A cause de la capacit de courant des systmes alimentation CC, des prcautions devraient tre prises lors de la connexion de l'alimentation CC pour viter des courts-circuits et des risques d'incendie. Assurez-vous que l'alimentation CC est isole de toute source de courant CA (secteur) et que l'installation est conforme la rglementation locale. La capacit maximale permissible en courant du circuit de distribution de la connexion alimentant le produit est de 16A (20A aux Etats-Unis et Canada). Le coupe-circuit dans l'installation du btiment devrait avoir une capacit leve de rupture et devrait fonctionner sur courant de court-circuit dpassant 35A (40A aux Etats-Unis et Canada). Avant la connexion des cbles d'alimentation en courant CC, assurez-vous que le circuit CC n'est pas sous tension. Localisez le coupe-circuit dans le tableau desservant l'quipement et fixez-le en position OFF. Lors de la connexion de cbles d'alimentation CC, connectez d'abord le conducteur de mise la terre la borne correspondante, puis le ple positif et en dernier, le ple ngatif. Remettez le coupe-circuit en position ON. Un disjoncteur facilement accessible, adapt et approuv devrait tre intgr l'installation du btiment. Le disjoncteur devrait dconnecter simultanment les deux ples si l'alimentation en courant CC est flottante.
Declaration of Conformity
Manufacturer's Name: Manufacturer's Address: declares that the product: Product Name: Optimux-108L RAD Data Communications Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
conforms to the following standard(s) or other normative document(s): EMC: EN 55022:2006 + A1:2007 EN 55024:1998 + A1:2001, A2:2003 EN 61000-3-2:2006 Information technology equipment Radio disturbance characteristics Limits and methods of measurement. Information technology equipment Immunity characteristics Limits and methods of measurement. Electromagnetic compatibility (EMC) Part 3-2: Limits Limits for harmonic current emissions (equipment input current 16A per phase) Electromagnetic compatibility (EMC) Part 3-3: Limits Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current 16A per phase and not subject to conditional connection. Information technology equipment Safety Part 1: General requirements.
Safety:
EN 60950-1:2005
Supplementary Information: The product herewith complies with the requirements of the EMC Directive 2004/108/EC, the Low Voltage Directive 2006/95/EC and the R&TTE Directive 99/5/EC for wired equipment. The product was tested in a typical configuration. Tel Aviv, 28 February, 2009
Communications
GmbH,
Otto-Hahn-Str.
28-30,
85521
Glossary
Address Agent Analog Attenuation Balanced
A coded representation of the origin or destination of data. In SNMP, this refers to the managed system. A continuous wave or signal (such as human voice). Signal power loss through equipment, lines or other transmission devices. Measured in decibels. A transmission line in which voltages on the two conductors are equal in magnitude, but opposite in polarity, with respect to ground. Unit of signaling speed equivalent to the number of discrete conditions or events per second. If each signal event represents only one bit condition, baud rate equals bps (bits per second). The smallest unit of information in a binary system. Represents either a one or zero (1 or 0). A storage device. Commonly used to compensate for differences in data rates or event timing when transmitting from one device to another. Also used to remove jitter. The 53-byte basic information unit within an ATM network. The user traffic is segmented into cells at the source and reassembled at the destination. An ATM cell consists of a 5-byte ATM header and a 48-byte ATM payload, which contains the user data. A path for electrical transmission between two or more points. Also called a link, line, circuit or facility. A term for the source(s) of timing signals used in synchronous transmission. Information represented in digital form, including voice, text, facsimile and video. A measure of power in communications: the decibel in reference to one milliwatt (0 dBm = 1 milliwatt and -30 dBm = .001 milliwatt). The detection and isolation of a malfunction or mistake in a communications device, network or system. The binary (1 or 0) output of a computer or terminal. In data communications, an alternating, non-continuous (pulsating) signal.
Baud
Bit Buffer
Cell
Diagnostics Digital
E1 Line
A 2.048 Mbps line, common in Europe, that supports thirty-two 64 kbps channels, each of which can transmit and receive data or digitized voice. The line uses framing and signaling to achieve synchronous and reliable transmission. The most common configurations for E1 lines are E1 PRI, and unchannelized E1. Encapsulating data is a technique used by layered protocols in which a low level protocol accepts a message from a higher level protocol, then places it in the data portion of the lower-level frame. The logistics of encapsulation require that packets traveling over a physical network contain a sequence of headers. A local area network (LAN) technology which has extended into the wide area networks. Ethernet operates at many speeds, including data rates of 10 Mbps (Ethernet), 100 Mbps (Fast Ethernet), 1,000 Mbps (Gigabit Ethernet), 10 Gbps, 40 Gbps, and 100 Gbps. A logical grouping of information sent as a link-layer unit over a transmission medium. The terms packet, datagram, segment, and message are also used to describe logical information groupings. A circuit or device permitting transmission in two directions (sending and receiving) at the same time. An ITU standard for the physical and electrical characteristics of various digital interfaces, including those at 64 kbps and 2.048 Mbps. Gateways are points of entrance and exit from a communications network. Viewed as a physical entity, a gateway is that node that translates between two otherwise incompatible networks or network segments. Gateways perform code and protocol conversion to facilitate traffic between data highways of differing architecture. A circuit or device capable of transmitting in two directions, but not at the same time. The combined effect of resistance, inductance and capacitance on a transmitted signal. Impedance varies at different frequencies. A shared boundary, defined by common physical interconnection characteristics, signal characteristics, and meanings of exchanged signals. Also known as an Internet address. A unique string of numbers that identifies a computer or device on a TCP/IP network. The format of an IP address is a 32-bit numeric address written as four numbers from 0 to 255, separated by periods (for example, 1.0.255.123). The deviation of a transmission signal in time or phase. It can introduce errors and loss of synchronization in high speed synchronous communications.
Encapsulation
Ethernet
Frame
Gateway
IP Address
Jitter
Laser
A device that transmits an extremely narrow and coherent beam of electromagnetic energy in the visible light spectrum. Used as a light source for fiber optic transmission (generally more expensive, shorter lived, single mode only, for greater distances than LED). A type of diagnostic test in which the transmitted signal is returned to the sending device after passing through all or part of a communications link or network. An application that receives Simple Network Management Protocol (SNMP) information from an agent. An agent and manager share a database of information, called the Management Information Base (MIB). An agent can use a message called a traps-PDU to send unsolicited information to the manager. A manager that uses the RADview MIB can query the RAD device, set parameters, sound alarms when certain conditions appear, and perform other administrative tasks. A fiber with a large core diameter; 50-200 microns compared with the wavelength of light. It therefore propagates more than one mode. With multimode fiber, light traverses multiple paths, some longer than others. This leads to dispersion, which reduces optical range. At one end of a communications link, a device that combines several lower speed transmission channels into a single high speed channel. A multiplexer at the other end reverses the process. Sometimes called a mux. See Bit Interleaving/Multiplexing. (1) An interconnected group of nodes. (2) A series of points, nodes, or stations connected by communications channels; the collection of equipment through which connections are made between data stations. Parameters are often called arguments, and the two words are used interchangeably. However, some computer languages such as C define argument to mean actual parameter (i.e., the value), and parameter to mean formal parameter. In RAD CLI, parameter means formal parameter, not value. Layer 1 of the OSI model. The layer concerned with electrical, mechanical, and handshaking procedures over the interface connecting a device to the transmission medium. The physical interface to a computer or multiplexer, for connection of terminals and modems. One or more characters in a command line interface to indicate that the computer is ready to accept typed input. A formal set of conventions governing the formatting and relative timing of message exchange between two communicating systems. The process of selecting the most efficient circuit path for a message.
Loopback
Manager
Multimode Fiber
Multiplexer
Network
parameters
Physical Layer
Routing
Single Mode
Describing an optical wave-guide or fiber that is designed to propagate light of only a single wavelength (typically 5-10 microns in diameter). See Synchronous Transmission. A digital transmission link with a capacity of 1.544 Mbps used in North America. Typically channelized into 24 DS0s, each capable of carrying a single voice conversation or data stream. Uses two pairs of twisted pair wires. The virtual terminal protocol in the Internet suite of protocols. It lets users on one host access another host and work as terminal users of that remote host. Instead of dialing into the computer, the user connects to it over the Internet using Telnet. When issuing a Telnet session, it connects to the Telnet host and logs in. The connection enables the user to work with the remote machine as though a terminal was connected to it.
Sync T1
Telnet
1.
Installing Optimux-108L
Determine the required configuration of Optimux-108L based on your application. Connect the user/network ports as required for the application. For more information refer to the sections that follow. Connect the unit to power.
3. Note the correct connection of the transmit and receive cables to the corresponding connectors. Avoid sharp bends and twisting of the fiber-optic cables. Refer to Appendix A for information on Optimux-108L port connectors.
Notes
1. SF1 connector must work opposite SF2 and not opposite the same type of link. 2. For WDM option, only one fiber optic cable per link should be connected.
Warning
Installing Optimux-108L
To connect to DC power through the AC/DC power inlet: Refer to the AC/DC adapter plug supplement for instructions on wiring the DC adapters. The AC/DC Adapter (AD) Plug supplement is provided at the end of this manual.
Note
A DC adaptor plug for the -48/-60 VDC power connection is supplied with the unit.
To connect to DC power using a 48 VDC on-board power supply: 1. Connect the DC power supply cable according to the panel polarity marking found under the DC connector. 2. Connect ground wiring to the central pin of the DC inlet connector.
Note
2.
The Optimux-108L/BM local DIP switches allow you to configure the Fault Propagation and Auto Cross Cable Detection.
3.
Note
Note
In the Optimux-108L with Ethernet user port, the Ethernet menu may display the configuration for ETH-USER port. To toggle between configurations, select Port Number and the Port Number Menu appears.
2. Select Device Number to set the device location (local or remote). 3. Select Port Number to set the Fast Ethernet port number to ETH-MNG. 4. Select Autonegotiation to toggle between the Enabled and Disabled options. 5. Select Speed and Duplex to set the desired speed. 6. Select Alarms to mask or unmask the Fast Ethernet alarms. This option identifies whether alarms triggered by this Ethernet port are masked or not. When masked, these alarms are not trapped and are not recorded in the log file.
Contents
Chapter 1. Introduction 1.1 Overview.................................................................................................................... 1-1 Product Options...................................................................................................... 1-1 Applications ............................................................................................................ 1-1 Features ................................................................................................................. 1-2 1.2 Physical Description ................................................................................................... 1-2 1.3 Functional Description................................................................................................ 1-3 E1 Transceivers ....................................................................................................... 1-3 Fiber Optic Transceiver............................................................................................ 1-3 Field-Programmable Gateway Array (FPGA).............................................................. 1-5 Ethernet Transceivers ............................................................................................. 1-5 DIP Switch .............................................................................................................. 1-5 Timing .................................................................................................................... 1-5 Test and Diagnostics ............................................................................................... 1-6 Alarms and Alarm Indications .................................................................................. 1-6 Uplink and Tributaries ........................................................................................ 1-6 Response to Alarm Conditions ............................................................................ 1-6 Events .................................................................................................................... 1-6 Management .......................................................................................................... 1-7 Power Supply .......................................................................................................... 1-7 1.4 Technical Specifications.............................................................................................. 1-7 Chapter 2. Installation and Setup 2.1 Site Requirements and Prerequisites .......................................................................... 2-1 Clearance................................................................................................................ 2-1 Power ..................................................................................................................... 2-2 Ambient Temperature ............................................................................................. 2-2 2.2 Package Contents ...................................................................................................... 2-2 2.3 Required Equipment ................................................................................................... 2-2 Hand Tools and Kits ................................................................................................ 2-2 Cables .................................................................................................................... 2-2 2.4 Mounting Optimux-108L............................................................................................. 2-3 2.5 Connecting to Fiber Optic Equipment.......................................................................... 2-3 Connecting to Uplink Equipment ............................................................................. 2-4 Connecting to E1 Equipment ................................................................................... 2-4 Connecting to User Ethernet Equipment .................................................................. 2-5 Connecting to Management Ethernet Equipment ..................................................... 2-6 2.6 Connecting to Power .................................................................................................. 2-6 Connecting to AC Power.......................................................................................... 2-6 Connecting to DC Power ......................................................................................... 2-7 Chapter 3. Operation 3.1 Turning On the Unit ................................................................................................... 3-1 3.2 Indicators .................................................................................................................. 3-1 Front Panel Indicators ............................................................................................. 3-1 Rear Panel Indicators .............................................................................................. 3-2 Normal Operation ................................................................................................... 3-3
Table of Contents
3.3 Default Settings ......................................................................................................... 3-4 Optimux-108L/BM ................................................................................................... 3-4 Fully-Managed Optimux-108L .................................................................................. 3-4 3.4 Configuration and Management Alternatives .............................................................. 3-6 Optimux-108L/BM ................................................................................................... 3-6 Managing the Unit Using Local Switches ............................................................. 3-6 Managing the Unit Remotely .............................................................................. 3-6 Fully-Managed Optimux-108L .................................................................................. 3-6 Working with Telnet ........................................................................................... 3-7 Working with Web Terminal ................................................................................ 3-9 Working with SNMP-Based Management System ............................................... 3-11 3.5 Optimux-108L Menu Map ......................................................................................... 3-12 3.6 Turning Off the Unit ................................................................................................. 3-14 Chapter 4. Configuration 4.1 Configuring an Optimux-108L/BM ............................................................................... 4-1 Configuring the Unit Remotely ................................................................................ 4-1 Configuring the Unit Using DIP Switches .................................................................. 4-2 4.2 Configuring a Fully-Managed Optimux-108L ................................................................ 4-2 Configuring Optimux-108L for Management ............................................................ 4-2 Setting Device Information ................................................................................. 4-3 Configuring the IP Host ...................................................................................... 4-3 Configuring Optimux-108L Communities ............................................................. 4-4 Setting up the Manager List ............................................................................... 4-4 Controlling Management Access ......................................................................... 4-5 Configuring Control Port ..................................................................................... 4-6 Configuring the Management Ethernet Port (MNG-ETH) ...................................... 4-7 Configuring Optimux-108L for Operation................................................................. 4-8 Configuring the Ethernet User Port (USER-ETH) .................................................. 4-8 Configuring the Fault Propagation ...................................................................... 4-9 Configuring E1 Channel .................................................................................... 4-11 Configuring Uplink ............................................................................................ 4-11 4.3 Performing Additional Tasks ..................................................................................... 4-12 Displaying the Optimux-108L Inventory ................................................................. 4-12 Displaying Optimux-108L Status ............................................................................ 4-13 Displaying System Status Information ............................................................... 4-13 Monitoring the Physical Ports ........................................................................... 4-14 Listing Users ......................................................................................................... 4-17 Changing a Password ............................................................................................ 4-18 Transferring Software and Configuration Files ....................................................... 4-19 Viewing File System Information............................................................................ 4-19 Factory Default Settings ....................................................................................... 4-20 Resetting Optimux-108L ....................................................................................... 4-21 Chapter 5. Monitoring and Diagnostics 5.1 Monitoring Performance ............................................................................................. 5-1 Optimux-108L/BM ................................................................................................... 5-1 Fully-Managed Optimux-108L .................................................................................. 5-3 Monitoring the Physical Ports ............................................................................. 5-4 Monitoring the Status of the Ethernet Port......................................................... 5-4 Monitoring the Status of the Uplink .................................................................... 5-5 Monitoring the Status of the E1 Port .................................................................. 5-6
ii
Table of Contents
5.2 Detecting Problems .................................................................................................... 5-7 Optimux-108L/BM ................................................................................................... 5-7 LEDs .................................................................................................................. 5-7 Alarms ............................................................................................................... 5-7 Fully-Managed Optimux-108L .................................................................................. 5-8 LEDs .................................................................................................................. 5-8 Alarms and Traps ............................................................................................... 5-8 5.3 Handling Events ......................................................................................................... 5-9 Displaying Events .................................................................................................... 5-9 Clearing Events ..................................................................................................... 5-10 Displaying Active Alarms ....................................................................................... 5-10 Masking Alarms ..................................................................................................... 5-12 5.4 Troubleshooting ....................................................................................................... 5-12 5.5 Testing Optimux-108L/BM ........................................................................................ 5-14 Running Loopbacks ............................................................................................... 5-14 Switch.............................................................................................................. 5-14 Running Loopbacks on the Uplink ..................................................................... 5-16 Running Loopbacks on E1 Tributary Channels ................................................... 5-17 Clearing Loopbacks ............................................................................................... 5-19 5.6 Testing Fully-Managed Optimux-108L ....................................................................... 5-19 Running Loopbacks ............................................................................................... 5-19 Running Loopbacks on the Uplink ..................................................................... 5-20 Running Loopbacks on E1 Tributary Channels ................................................... 5-21 Clearing Loopbacks ............................................................................................... 5-23 5.7 Frequently Asked Questions ..................................................................................... 5-23 5.8 Technical Support .................................................................................................... 5-24 Chapter 6. Software Upgrade 6.1 Impact ....................................................................................................................... 6-1 6.2 Software Upgrade Options ......................................................................................... 6-1 6.3 Prerequisites .............................................................................................................. 6-1 Software Files ......................................................................................................... 6-2 System Requirements ............................................................................................. 6-2 6.4 Upgrading Optimux-108L Software via the File Utilities Menu...................................... 6-2 Verifying the Optimux-108L Host Parameters .......................................................... 6-3 Activating the TFTP Server ....................................................................................... 6-3 Downloading the New Software Release File to Optimux-108L ................................ 6-3 Downloading a New Software Release via TFTP ....................................................... 6-4 Chapter 7. Application Tutorial 7.1 Configuring Transparent Services over Fiber ............................................................... 7-1 Equipment List ........................................................................................................ 7-1 Installing the Units .................................................................................................. 7-2 Connecting two Optimux-108L Units ....................................................................... 7-3 Testing the Application ........................................................................................... 7-3 Running Diagnostic Tests ........................................................................................ 7-3
iii
Table of Contents
7.2 Optimux-108L in a Point-to-Point Application .............................................................. 7-3 Equipment List ........................................................................................................ 7-4 Installing the Units .................................................................................................. 7-4 Preparing a Control Session .................................................................................... 7-6 Setting System Parameters ..................................................................................... 7-6 Testing the Application ........................................................................................... 7-7 Running Diagnostic Tests ........................................................................................ 7-7 Appendix A. Connection Data
iv
Chapter 1 Introduction
1.1 Overview
Optimux-108L multiplexes four E1 channels and 100 Mbps Ethernet over a fiber optic link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber.
Product Options
In this manual, the generic term Optimux-108L is used when the information is applicable to all the equipment versions. The complete equipment designation is used only for information applicable to specific equipment versions. Optimux-108L is available in two product versions: by default, Optimux-108L is fully-managed, but it may also be ordered with basic management. This latter product option will be referred in to this manual as Optimux-108L/BM. Optimux-108L includes a fiber optic uplink and four tributary E1 links, which can be ordered with a balanced or unbalanced interface. Optimux-108L can be also ordered with an additional Ethernet user port. Both product versions are available in a plastic or metal enclosure.
Applications
Figure 1-1 illustrates a typical application of the Optimux-108L unit with Ethernet
user port.
Overview
1-1
Chapter 1 Introduction
Figure 1-2 shows Optimux-108L extending the E1 range over fiber when
operating opposite the OP-108C card installed in the LRS-102 chassis.
Figure 1-2. Typical Application of Optimux-108L opposite OP-108C Card Installed in LRS-102
Features
Optimux-108L supports a variety of built-in optical uplink interfaces including: 850 nm VCSEL (Vertical Cavity Surface Emitting Laser) for multimode fiber 1310 nm LED for multimode fiber 1310/1550 nm laser diode or long haul laser diode for extended range over single-mode fiber Single fiber (SF1, SF2 options) using a 1310 nm and 1550 nm laser diode transmitter with WDM technology, which enables the laser to transmit the signal at a different wavelength than the receive signal Single fiber (SF3 option) using SC/APC (Angle-Polished Connector) technology, with a 1310 nm laser diode for single wavelength operation.
Optimux-108L has comprehensive test and diagnostics capabilities that include local and remote loopbacks on the uplink interface and on each E1 tributary link. To facilitate system diagnostics, Optimux-108L features LED status indicators, AIS alarm generation and recognition. Optimux-108L can be powered from a wide-range power supply (100 to 240 VAC or 40 to -72 VDC) or from a dedicated on-board DC power supply (-40 VDC to -57 VDC). Optimux-108L is a compact standalone unit. A rack mount adapter kit enables installation of one or two (side-by-side) units in a 19-inch rack.
1.2
Physical Description
Optimux-108L is a 1U high, compact, easy-to-install standalone device. The front view of Optimux-108L is shown in Figure 1-3.
1-2
Physical Description
Chapter 1 Introduction
1.3
Functional Description
E1 Transceivers
The Optimux-108L E1 transceivers enable the transmission and reception of tributary signals. They convert the analog signals coming from the E1 line into digital signals that can be handled by the field-programmable gate array (FPGA) and convert the digital signals coming from the FPGA into required level and shape. Line transformers isolate the transceivers from the E1 line and perform impedance matching to the line.
Table 1-1 and Table 1-2 provide information on the characteristics of the optical
subsystem, including the maximum range over typical fiber optic cable for a product without and with user Ethernet port respectively.
Functional Description
1-3
Chapter 1 Introduction
Table 1-1 Fiber Optic Interface Characteristics for a Product without User Ethernet port
Wavelength Fiber Type Transmitter Type Typical Output Power [dBm] -6 -12 -18 -2 -12 -12 -12 -12 -2 Receiver Sensitivity [dBm] -34 -34 -32 -34 -27 -34 -34 -34 -34 Typical Max. Range [km 4.5 47 7 72 20 47 47 47 120 miles] 2.8 29.2 4.3 44.7 12.4 29.2 29.2 29.2 ST, SC, FC/PC ST, SC, FC/PC ST, SC ST, SC, FC/PC SC/APC only SC SC ST, SC, FC/PC Connector Type
62.5/125 multimode LED 9/125 single mode Laser [long haul] Laser [SF3] Laser WDM [SF1] Laser WDM [SF2] Laser Laser [long haul]
1310 9/125 single mode Transmit/Receive Single fiber 1310/1550 9/125 single mode Transmit/Receive Single fiber 1550/1310 9/125 single mode Transmit/Receive Single fiber 1550 1550 9/125 single mode 9/125 single mode
Table 1-2 Fiber Optic Interface Characteristics for a Product with User Ethernet port
Wavelength Fiber Type Transmitter Type Typical Output Power [dBm] Receiver Sensitivity [dBm] -32 -28 -30 -34 -27 -28 -28 -28 -34 Typical Max. Range [km 2 20 2 40 20 20 20 20 80 miles] 1.2 12.4 1.2 24.8 12.4 12.4 12.4 12.4 49.7 ST, SC, FC/PC ST, SC, FC/PC ST, SC ST, SC, FC/PC SC/APC only SC SC ST, SC, FC/PC ST, SC, FC/PC Connector Type
[m]
62.5/125 multimode Laser (VCSEL) -6 9/125 single mode Laser -12 -18 -2 -12 -12 -12 -12 -2
62.5/125 multimode LED 9/125 single mode Laser [long haul] Laser [SF3] Laser WDM [SF1] Laser WDM [SF2] Laser Laser [long haul]
1310 9/125 single mode Transmit/Receive Single fiber 1310/1550 9/125 single mode Transmit/Receive Single fiber 1550/1310 9/125 single mode Transmit/Receive Single fiber 1550 1550 9/125 single mode 9/125 single mode
To optimally meet a wide range of system requirements, the fiber optic interface can be ordered for operation over 62.5/125 micron multimode fibers (typical attenuation 3.5 dB/km at 850 nm), as well as over low-loss 9/125 micron single mode fibers (typical attenuation 0.4 dB/km at 1310 nm, and 0.25 dB/km at 1550 nm).
1-4
Functional Description
Chapter 1 Introduction
The fiber optic uplink interface is fixed and cannot be replaced in the field. All fiber optic interface options offer high performance and have a wide dynamic range.
Note
The SF3 option uses an SC/APC connector. The FO cable connected to it must therefore be of the same type.
Ethernet Transceivers
The Optimux-108L Ethernet transceiver enables operation of the Optimux-108L Ethernet user and management ports. The Ethernet user port operates at a rate of 10/100 Mbps full duplex, autonegotiation enable/disable. It supports auto cross over cable detection and fault propagation control options. The Ethernet management port operates at a rate of 10/100 Mbps full/half duplex, autonegotiation enable/disable and supports the auto cross over cable detection.
DIP Switch
In Optimux-108L/BM, the DIP switch is used for diagnostics and control over the user Ethernet port parameters. Switch positions provide status indications of the Optimux-108L user port and the loops performed by the unit. The DIP switch is located on the rear panel and is activated only during a point-topoint connection between a pair of Optimux-108L/BM units. If Optimux-108L/BM is connected to a remote LRS-102/ OP-108C card or a fully managed Optimux-108L or Optimux-108 product, rear panel switches of the local unit are inactive. For more information on activation of the DIP switches, their positions and uses, see Chapter 4.
Timing
The uplink interface operates in internal timing mode. The clock of each E1 channel is independent and transferred transparently.
Optimux-108L Ver. 2.0 Functional Description 1-5
Chapter 1 Introduction
If you do not use all the tributaries of a fully-managed Optimux-108L, you can disable the alarm indications related to the unused tributaries through the software. For more information refer to Chapter 5.
An AIS signal is sent on a tributary instead of the tributary data stream through the uplink in the following cases: Loss of tributary input signal is detected AIS is received on the tributary input Local loopback is activated on the E1 input.
Events
The following events are displayed in the event Log of a fully-managed unit:
1-6
Exceeding the maximum size of the event log buffer, which results in old events being overwritten by the new ones Performing a login to the unit Reading/writing via SNMP with wrong community (SNMP Auth Failure) Unit power-up (ColdStart) Alarms on the uplink and E1 ports (Signal Loss, AIS) Remote connection Fail
Optimux-108L Ver. 2.0
Functional Description
Chapter 1 Introduction
Management
Optimux-108L can be configured and monitored remotely via Telnet, Web-based remote access terminal (Web Server, previously ConfiguRAD) or SNMP station.
Power Supply
The Optimux-108L power supply produces the main voltage; all other voltages required on board are generated from it. Optimux-108L may be ordered with one of the following power supplies: A wide-range AC/DC power supply connected to an AC (100 to 240 VAC) or DC (40 VDC to -72VDC) power source; or A dedicated on-board DC power supply (-40 VDC to -57 VDC).
1.4
Uplink Interface
Technical Specifications
One Fiber Optic Refer to Table 1-1 and Table 1-2 ST, SC, FC/PC, or SC/PC, ordered option (SF1/SF2 options only available with SC) (SF3 option only available with SC/APC) G.955 4
Standards
E1 Tributary Interface
ITU-T Rec. G.703, G.823, G.742 (Optimux-108L without Ethernet USER port)
Nominal Line Data Rate 2048 kbps Line Code Bit Rate Tolerance Line Impedance Connectors
HDB3 25 ppm 120 (balanced) or 75 (unbalanced) Balanced interface: Shielded RJ-45 connector Unbalanced interface: two BNC coaxial connectors
Technical Specifications
1-7
Chapter 1 Introduction
0 to 6 dB Per ITU-T Rec. G.823 10/100BaseT 10/100 Mbps Full -duplex only Autonegotiation enable/disable Auto cross over cable enable/disable
USER-ETH Port
Connector Standard
Shielded RJ-45 IEEE 802.3 10/100BaseT 10/100 Mbps Full/half-duplex Autonegotiation enable/disable
MNG-ETH Port
Connector
Shielded RJ-45 Internal Transferred transparently, independent for each channel Local and remote loopbacks on uplink and on each E1 tributary link
Timing
Diagnostics Indicators
Front Panel
PWR LINK A/B
On (green): power supplies OK Off: power supply fault or disconnected On (red): Sync/Signal Loss on uplink On (yellow): AIS is detected
1-8
Technical Specifications
Chapter 1 Introduction
CH1 to CH4
On (red): Signal Loss on channel On (yellow): AIS received on channel Blinking (yellow): Loop (RLB or LLB) is performed on E1 channel (Optimux-108L/BM only) Off: normal operation
Rear Panel
SD LINK/ACT
On (green): signal exists on Link Off: no signal on Link On (yellow): link is up Off: link is down Blinks: frames are transmitted/received On (green): 100 Mbps mode Off: 10 Mbps mode
100
Power
Fully-Managed Optimux-108L
Wide range AC/DC Power Supply On board DC Power Supply
100 to 240 VAC, 50 or 60 Hz, Max. 18 VA -48 VDC (-40 to-72 VDC), Max. 6W -48 VDC power supply (-40 to 57 VDC) Max. 5W
Optimux-108L/BM
Wide range AC/DC Power Supply On board DC Power Supply
100 to 240 VAC, 50 or 60 Hz, Max. 11 VA -48 VDC (-40 to-72 VDC), Max. 2.7W -48 VDC power supply (-40 to -57 VDC) Max. 2W
Physical
Plastic Enclosure
Height Width Depth Weight
4.37 cm / 1.7 in (1U) 21.7 cm /8.5 in 17.0 cm / 6.7 in 0.5 kg / 1.1 lb
Metal Enclosure
Height Width Depth Weight
4.73 cm (1.8 in) 21.5 cm (8.4 in) 15.25 cm (6.0 in) 0.7 kg (1.5 lb)
Technical Specifications
1-9
Chapter 1 Introduction
Environment
1-10
Technical Specifications
Optimux-108L is delivered completely assembled, and is factory set for basic operation. It is designed for installation as a desktop unit or for mounting in a 19-inch rack. For rack installation instructions, refer to the Rack Mounting Kit for 19-inch Racks guide that comes with the RM kit. After installing the unit, refer to Chapter 3 for the operating instructions. If a problem is encountered, refer to Chapter 5 for test and diagnostic instructions. No internal settings, adjustment, maintenance and repairs should be performed by either the operator or the user. Such activities must be performed only by skilled personnel who are aware of the hazards involved. Always observe standard safety precautions during installation, operation, and maintenance of this product.
Warning
Note
Before installing the product, review Handling Energized Products at the beginning of the manual.
2.1
Optimux-108L is intended for installation on desktop or 19 racks. The RM-33-2 mounting kit is available from RAD for mounting 1 or 2 units in a 19 rack. Avoid sharp bends when planning the routing of fiber optic cables.
Clearance
Allow at least 90 cm (36 in) of frontal clearance for operating and maintenance accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal lines and interface cables.
2-1
Power
AC-powered Optimux-108L units should be installed within 1.5m (5 ft) of an easily accessible grounded AC outlet capable of furnishing the voltage in accordance with Optimux-108L nominal supply voltage. DC-powered Optimux-108L units require a -48 VDC power source, which must be adequately isolated from the main supply.
Note
Refer also to the sections describing connections of AC and DC mains at the beginning of the manual.
Ambient Temperature
The ambient operating temperature of Optimux-108L is 0 to 55C (32 to 122F), at a relative humidity of up to 90%, non-condensing.
2.2
Package Contents
The Optimux-108L package contains the following items: Optimux-108L unit AC power cable (depending on the ordering option) DC adapter plug (depending on the ordering option) Technical Documentation CD RM-33-2 rack-mount kit (if ordered) RM-35 or WM-35 rack mount kits for the metal enclosure unit (if ordered).
2.3
Required Equipment
Cables
Optimux-108L comes equipped with an appropriate (country or region dependent) power cord to be connected from the power inlet located on the rear panel to the mains outlet. Refer to the following table to determine what cables and connectors are required for installation. For information on connector pinouts, refer to Appendix A.
2-2
Required Equipment
2.4
Mounting Optimux-108L
Optimux-108L is designed for installation as a desktop unit. It can also be mounted in a 19" rack. For rack mounting instructions, refer to the RM-33-2 installation kit manual that comes with the RM kit for plastic enclosure unit and RM-35 or WM-35 rack mount kits for the metal enclosure unit. If Optimux-108L is to be used as a desktop unit, place and secure the unit on a stable, non-movable surface. Refer to the clearance and temperature requirements in Site Requirements and
Prerequisites.
2.5
Eye damage may be caused by a broken or unterminated fiber optic or connector if the laser beam is viewed directly or with improper optical instruments. The laser beam is invisible.
Warning
Access to the inside of the equipment is permitted only to qualified and authorized service personnel.
Warning
Disconnect the unit from the power line and from all the cables before removing cover. Dangerous high voltages are present inside the Optimux-108L when it is connected to power and/or to the links. Moreover, under external fault conditions, dangerous high voltages may appear on the lines connected to the Optimux-108L. Any adjustment, maintenance, and repair of the opened instrument under voltage should be avoided as much as possible and, when inevitable, would be carried out only by a skilled technician who is aware of the hazard involved. Capacitors inside the instrument may still be charged even after the instrument has been disconnected from its source of supply.
Warning
2-3
Warning
Do not look directly into the optical connectors while the unit is operating. The laser beams are invisible. Do not attempt to adjust the laser drive current. The use of optical instruments with this product will increase eye hazard. Laser power up to 1 mW at 1300 nm and 1550 nm could be collected by an optical instrument. Use of controls or performing procedures other than those specified herein may result in hazardous radiation exposure.
Notes
SF1 connector must work opposite SF2 and not opposite the same type of link. For WDM option, only one fiber optic cable per link should be connected. In applications where Optimux-108L is working with an Optimux-108 or
OP-108C, the Optimux-108L uplink must be connected to Link A of Optimux-108/OP-108C for proper operation.
2-4
Connecting to E1 Equipment
Optimux-108L has four RJ-45 connectors for the balanced E1 interface or four dual BNC connectors for the unbalanced interface. For information on the RJ-45 connector pin allocation, refer to Appendix A. To connect the tributary interfaces: Connect each of the tributary cables to the connector(s) of the corresponding to the interface. For the unbalanced interface, connect the cables to the two BNC connectors designated RX (receive input) and TX (transmit output). Note the correct connection of the transmit and receive cables to the RX and TX connectors (Figure 2-2).
2-5
2.6
Connecting to Power
Optimux-108L operates on: 110240 VAC or -48/-60 VDC through the AC/DC power inlet when using a wide range power supply; or -40 V to -57 VDC through a dedicated DC inlet when using an on-board 48 VDC power supply.
Warning
Before connecting or disconnecting any cable, the protective earth terminals of this unit must be connected to the protective ground conductor of the mains (AC or DC) power cord. If you are using an extension cord (power cable) make sure it is grounded as well. Any interruption of the protective (grounding) conductor (inside or outside the instrument) or disconnecting of the protective earth terminal can make this unit dangerous. Intentional interruption is prohibited.
2-6
Connecting to Power
Connecting to AC Power
AC power should be supplied via a 1.5m (5 ft) standard power cable terminated by a standard 3-prong socket. The cable is provided with the unit. To connect to AC power supply: 1. Connect the power cable to the AC/DC power connector on the Optimux-108L rear panel. See Figure 2-7 for detail.
Connecting to DC Power
When the unit is ordered with a wide range power supply, a special IEC 60320 adapter plug for the -48/-60 VDC power supply is supplied with the unit.
To connect to DC power using a dedicated on-board 48 VDC power supply: 1. Connect the DC power supply cable according to the panel polarity marking found under the DC connector.
Connecting to Power
2-7
Note
2-8
Connecting to Power
Chapter 3 Operation
This chapter explains the power-on and power-off procedures and provides a detailed description of the Optimux-108L controls and indicators as well as their functions. Before attempting to operate Optimux-108L, make sure you have completed and checked the installation procedures described in Chapter 2.
3.1
To turn on an Optimux-108L unit: 1. Connect the power cable to the power connector on the rear panel of the Optimux-108L. 2. Connect the power cable to the electric outlet. The PWR indicator lights in green.
3.2
Indicators
Indicators
3-1
Chapter 3 Operation
The rear panel of an unbalanced Optimux-108L/BM unit with USER Ethernet port is shown in Figure 3-2. The rear panel of an unbalanced fully-managed Optimux-108L with USER Ethernet port is shown in Figure 3-3.
Table 3-1 lists the functions of the Optimux-108L rear panel indicators.
3-2
Indicators
Chapter 3 Operation
Figure 3-3. Rear Panel View of a Fully-Managed Optimux-108L Table 3-2. Optimux-108L Rear Panel Indicators and Push Buttons
LED Function USER ETH: LINK/ACT Color Yellow Meaning On: USER-ETH link is up Blinking: USER link is up and Rx and/or Tx frames are being transmitted Off: USER-ETH link is down USER ETH: 100 Green On 100M mode Off 10M mode MNG ETH: LINK/ACT Yellow On: MNG-ETH link is up Blinking: Management link is up and Rx and/or Tx frames are being transmitted Off: MNG-ETH link is down MNG ETH: 100 Green On 100M mode Off 10M mode SD Green On Signal is detected on fiber optic module Off signal not detected SET DEF PUSH BUTTON When pushed, returns the following parameters to their default values: IP Address IP Mask Default gateway
Normal Operation
During normal operation, the following appear: The PWR indicator lights green The indicator corresponding to the uplink lights All SYNC LOSS front-panel indicators are off.
Indicators
3-3
Chapter 3 Operation
3.3
Optimux-108L/BM
Default Settings
Table 3-3 lists the default settings of the Optimux-108L DIP switch. Table 3-3. Optimux-108L: DIP Switch Default Settings
Switch Number 1-4 5 6 7 Function Perform E1 loops on E1 channels 1-4 Performs loop on the uplink Determines the loop type (RLB or LLB) Fault Propagation (Optimux-108L with USER-ETH port only) Auto cross cable detect (Optimux-108L with USER-ETH port only) Default OFF (no loop) OFF (no loop) OFF (LLB loop) OFF (disable)
ON (enable)
Table 3-4 lists the factory default parameters of an Optimux-108L/BM unit when
accessed via the LRS-102/OP-108C card or via a fully-managed Optimux-108L.
Fully-Managed Optimux-108L
Table 3-5 lists the factory default parameters of a fully-managed Optimux-108L. Table 3-5. Optimux-108L Factory Default Parameters
Parameter System Description Default Value
Device Information
3-4
Default Settings
Installation and Operation Manual Parameter Description IP address IP mask Default gateway Read Community Write Community Trap Community Default Value
Chapter 3 Operation
Host
192.168.205.1 255.255.255.0 0.0.0.0 public private public All All All Off
Management Access
Ethernet
Local MNG-ETH MNG-ETH Port Enable Unmasked Local Fiber Optic Unmasked Local 1 E1 Channel Unmasked Local No Loop 5 No Loop (on all channels)
Link
E1
Diagnostics
Device Number Link Loop type Link LLB loop timeout (min) [1-255] Channels Loops
Default Settings
3-5
Chapter 3 Operation
3.4
After installation, there are no special operating procedures for Optimux-108L. Once it is powered up, the unit operates automatically. The units operational status can be monitored constantly.
Optimux-108L/BM
Managing the Unit Using Local Switches
The following parameters can be set by the user via the Optimux-108L local switches: RLB or LLB loops on the E1 tributary and Uplink ports Enable/Disable the USER-ETH fault propagation Enable/Disable the USER-ETH auto cross cable detection.
Fully-Managed Optimux-108L
Optimux-108L can be managed and configured using one of the following remote management tools: Telnet Web Server (ConfiguRAD) RADs Web-based application SNMP-based systems.
The remote management of an Optimux-108L unit is performed via the units Ethernet management port. Optimux-108L allows up to three simultaneous active management sessions. When connected via Telnet or Web, the user is disconnected after 10 minutes of inactivity (no keyboard input on the client computer). The following functions are supported by the Optimux-108L management software: Viewing system information (Inventory) Modifying configuration and mode of operation, including setting system default values and resetting the unit
Optimux-108L Ver. 2.0
3-6
Chapter 3 Operation
Monitoring Optimux-108L performance Initiating loopback tests (Diagnostic) Uploading and downloading software and configuration files.
Login
To prevent unauthorized modification of the operating parameters, Optimux-108L supports two access levels: Superuser can perform all the activities supported by the Optimux-108L management facility, including defining new users. Users access rights (read only) are defined by the superuser. Users are not allowed to create new users. Tech (technician) access rights (limited read/write authority). A technician has rights to read all but write only diagnostics and clear alarms.
1. After the SW finishes uploading, open the Telnet/Web/SNMP connection 2. On Telnet Connection, press several times Enter Until the following Password Prompt Screen appears. Optimux-108L USER NAME: PASSWORD: SU **** 0 M/ 1 C
Figure 3-4. Password Prompt Screen Note It is recommended to change default passwords to prevent unauthorized access to the unit.
To enter as a superuser: 1. Enter su for user name. 2. Enter 1234 for password. This allows you to configure all the parameters of Optimux-108L, and to change the su, user and tech passwords. To enter as a user: 1. Enter user for user name. 2. Enter 1234 for password.
3-7
Chapter 3 Operation
To set all passwords to the default values (1234): Log in as su and delete the units configuration through the configuration screens.
To enter as a technician: 1. Enter tech for user name. 2. Enter 1234 for password.
Choosing Options
To use the remote terminal to perform a desired activity: To select a menu item, type the corresponding line number and then press <Enter>. This will either display a submenu or a parameter selection screen or let you type the (free text) parameter value in the same row or toggle the current value of the corresponding parameter (relevant to ENABLE/DISABLE or ON/OFF selections). The type of response to be expected after selecting a menu item is indicated as follows: > Selecting that item will display a submenu or a parameter selection screen. Selecting that item will let you type the desired value in the same line. When neither symbol is displayed, selecting that item will toggle the current selection, now shown in brackets (for example, this will change ENABLE to DISABLE or vice versa).
...
Nothing
3-8
Chapter 3 Operation
option that displays these keys). The following keys may be used for navigation within tables: L move to the left R move to the right
In addition, the following shortcuts are also available: Tab select the next cell that may be changed S followed by <row number>,<col number> select a specific cell. For example, type S2,5 to select the fifth cell in the second row. The current value of a parameter is listed within parentheses ( ). To change a parameter value on a parameter selection screen: Type the line number corresponding to the desired value, and then press <Enter> To enter a value which requires free text entry, type in the desired string and then press <Enter>. Use backspace to erase the current string. Note that whenever applicable, the allowed range of values of a parameter is listed within square brackets [ ]. The entry is checked after pressing <Enter>, and it is accepted only if it is valid: If you make an error, for example, if you press a key not active on the current screen or select an invalid parameter value, an ERROR indicator appears in the right-hand corner. This indicator disappears as soon as you make a correct operation. If you select a parameter value incompatible with the current operating state or other parameters, you will see a message that explains the error. When done with the current screen, press <Esc> to return to the previous screen, or type ! to return directly to the main menu.
After a session is ended, it is necessary to re-enter a valid user name and password to start a new session.
3-9
Chapter 3 Operation
However, before using Web access, it is necessary to perform a preliminary configuration of the unit. When using a Web browser, pay attention to the following points: Enable scripts Configure the firewall that is probably installed on your PC in order to allow access to the destination IP address Disable pop-up blocking software (such as Google Popup Blocker); you may also have to configure your spyware/adware protection program to accept traffic from/to the destination IP address Browsers store the last viewed pages in a special cache. To prevent configuration errors, it is absolutely necessary to flush the browsers cache whenever you return to the same screen.
Login
To manage Optimux-108L via Web browser: 1. Open the Web browser. 2. Enter the Optimux-108L IP address in the address field of the browser. Use the following format: http://IP address (IP address stands for the actual Optimux-108L IP address). 3. After entering the address, press <Enter> to command the browser to connect. The Login window appears.
3-10
Chapter 3 Operation
Note
This includes up to five network sessions (Telnet, Web Server (ConfiguRAD), RADview)
If no user input is detected for 10 minutes during Web Server session,
3-11
Chapter 3 Operation
Optimux-108L supports several management information bases (MIBs). A MIB (Management Information Base) is a database of managed objects. The MIB contains the data regarding the network elements being controlled and monitored. Each characteristic of the element to manage is defined as an object in the MIB. The MIB is a hierarchical tree structure that acts as the repository for defined objects. Each object has an object name, a type, syntax, an access code (read-write, read-only, not-accessible, and write-only) and a status (mandatory, optional, obsolete). Optimux-108L supports appropriate groups (tables) of MIB II (SNMP standard MIB), and the RAD Private MIB as follows:
MIB RFC3418 RFC2863 RFC3593 RFC3895 RAD Private MIB Notes MIB-II MIB-II MIB-II Partially supported Partially supported radGen optimux Tables IANAiftype if PreHist-TC dsx1ConfigTable physicalConnectorTable mngTrapIPTable agnTrapMask (object) agnLed (object) OptMxConfigTable
Additional MIB information can be obtained from your local Authorized Business Partner. For the trap list, see Chapter 5.
3.5
Use the terminal menus to set and view configuration parameters. Figure 3-7 and Figure 3-8 illustrates the main menu and its submenus. Use this tree as a reference aid while performing configuration and control functions. Refer to Chapter 4 and Chapter 5 to find specific parameters.
3-12
Chapter 3 Operation
Figure 3-7. Main Menu Tree Optimux-108L with Ethernet User Port
Figure 3-8. Main Menu Tree Optimux-108L with Ethernet User Port (cont.)
3-13
Chapter 3 Operation
3.6
To power off the unit: Remove the power cord from the power source.
3-14
Chapter 4 Configuration
This chapter illustrates the configuration procedures of Optimux-108L units and explains their respective configuration parameters. Menu trees of the fully-managed Optimux-108L management software are shown in Chapter 3.
4.1
Configuring an Optimux-108L/BM
All Optimux-108L configurations can be performed using the LRS-102/OP-108C card, fully-managed Optimux-108L and Optimux-108 products. Fault propagation and auto cross cable detection can also be configured using the Optimux-108L DIP switches. Loopbacks are configured using either using the LRS-102/OP-108C card, fully-managed Optimux-108L and Optimux-108 products or the local switches.
Configuring an Optimux-108L/BM
4-1
Chapter 4 Configuration Parameter Speed Function When Autonegotiation is Disable, selects the data rate of the Ethernet port. When Autonegotiation is Enable, this parameter is replaced by Max. Capability Advertised Values
The available selections are listed in ascending order of capabilities: 10Mbps full duplex Full-duplex operation at 10 Mbps. 100Mbps full duplex Full-duplex operation at 100 Mbps.
Fault Propagation
Before starting the configuration, make sure that sections 1-6 of the DIP switch are set to the Off position (no loops on the tributary and uplink ports.) Before starting the configuration, make sure that sections 1-6 of the DIP switch are set to the Off position (no loops on the tributary and uplink ports.)
4.2
Optimux-108L is supplied with pre-configured (default) host IP parameters, which enables the user initial access via Telnet, Web Server (ConfiguRAD) or third-party SNMP station for further configuration.
Setting the Device Information Configuring IP Host Parameters Configuring Optimux-108L Communities Configuring the Network Managers Setting up the Managers List Controlling Management Access.
4-2
Chapter 4 Configuration
> Please select item <1 to 3> ESC-Previous menu; !-Main Menu; &-Exit
Note
4-3
Chapter 4 Configuration
Optimux-108L Configuration>System>Management>Host 1. 2. 3. 4. 5. 6. IP Address IP Mask Default Gateway Read Community Write Community Trap Community ... ... ... ... ... ... (192.168.205.1) (255.255.255.0) (0.0.0.0) (public) (private) (public)
> Please select item <1 to 6> ESC-Previous menu; !-Main Menu; &-Exit
4-4
Chapter 4 Configuration
Optimux-108L Configuration>System>Management>Managers List Num 1 2 3 4 5 6 7 8 9 10 IP Address (0.0.0.0) (0.0.0.0) (0.0.0.0) (0.0.0.0) (0.0.0.0) (0.0.0.0) (0.0.0.0) (0.0.0.0) (0.0.0.0) (0.0.0.0) Trap Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked ... (0.0.0.0)
1. Change Cell
4-5
Chapter 4 Configuration
Optimux-108L Configuration>System>Management>Management Access 1. Telnet 2. WEB 3. SNMP > > > (Enable) (Enable) (Enable)
> Please select item <1 to 3> ESC-Previous menu; !-Main Menu; &-Exit
> Please select item <1 to 3> ESC-Previous menu; !-Main Menu; &-Exit
4-6
Chapter 4 Configuration
To set the size of the scrolling window (available on Telnet only): 1. From the Control Port menu (Figure 4-5), select Set Scrolling Window Size to set it to a number between 0 to 8. 2. After setting a number, press Enter and then press S to save your changes. The screen is refreshed.
> Please select item <1 to 6> ESC-Previous menu; !-Main Menu; &-Exit
1 user(s)
4-7
Chapter 4 Configuration
5. Select Speed and Duplex (only when Autonegotiation is set to Disabled) and set the desired speed. Choose between the following options: 10BaseT Half Duplex 10BaseT Full Duplex 100BaseTX Half Duplex 100BaseTX Full Duplex 6. Select Alarms to mask or unmask the USER-ETH or MNG-ETH alarms. This option identifies whether alarms triggered by this Ethernet port are masked or not. When masked, these alarms are not trapped and are not recorded in the Event log file.
> Please select item <1 to 7> ESC-Previous menu; !-Main Menu; &-Exit
4-8
Chapter 4 Configuration
4. Select Administrative Status and set the status to either Up or Down. 5. Select Port Name to set a name to the port (up to 15 characters). 6. Select Autonegotiation and toggle between the Enabled or Disabled options. 7. Select Speed and Duplex (only when Autonegotiation is set to Disabled) and set the desired speed. Choose between the following options: 10BaseT Half Duplex 10BaseT Full Duplex 100BaseTX Half Duplex 100BaseTX Full Duplex. 8. Select MDIX Auto Cross Over and toggle between the Enabled or Disabled options. 9. Select Alarms to mask or unmask the USER Ethernet alarms. This option identifies whether alarms triggered by this Ethernet port are masked or not. When masked, these alarms are not trapped and are not recorded in the log file.
> Please select item <1 to 6> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Chapter 4 Configuration
4-10
Chapter 4 Configuration
Configuring E1 Channel
To configure the E1 channel parameters: 1. Navigate to Configuration>Physical Layer and select E1 (Figure 4-13). Optimux-108L Configuration>Physical Layer>E1 1. 2. 3. 4. Device Number Port number [1-4] Port Name Alarms > > ... > (Local) (1) () (Unmasked)
> Please select item <1 to 4> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Configuring Uplink
To configure the uplink parameters: Navigate to Configuration>Physical Layer and select Link.
4-11
Chapter 4 Configuration
Optimux-108L Configuration>Physical Layer>Link 1. Device Number 2. Port Name 3. Alarms > ... > (Local) (Fiber Optic) (Unmasked)
> Please select item <1 to 3> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Alarms
4.3
4-12
Chapter 4 Configuration
Optimux-108L Inventory 1. Device Number > (Local) Device type > (Optimux-108L) SW version (1.00) HW version (0.1/A_Firmware: Ver. 1.0) INTERFACES INFORMATION Link (Fiber Optic Multi mode SC 850nm) E1 Channel 1-4 (COAX, Unbalanced(75ohm)) ETH-MNG (RJ-45, 10/100BaseT) ETH-USER (RJ-45, 10/100BaseT) PS type > (DC) > Please select item <1 to 1> ESC-prev. menu; !-main menu; &-exit
1 user(s)
The status information is available via the Monitoring menu. To access the Monitoring menu: From the Main menu, select Monitoring. The Monitoring menu appears (see Figure 4-16). Optimux-108L Monitoring 1. System > 2. Physical Layer > ESC-prev. menu; !-main menu; &-exit 1 user(s)
4-13
Chapter 4 Configuration
The System Monitoring menu screen is shown in Figure 4-16. Table 4-5 explains the System Monitoring parameters. Sys Up Time format is: HH:MM:SS Optimux-108L Monitoring>System MAC Address Sys Up Time 1. Event Log 2. Active Alarms (0020D222E15F) ... (12:06:34) [] []
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Event Log
Ethernet Ports
The Ethernet Status Screen displays the current status of the Management and User Ethernet ports.
Note
For a device without User Ethernet port, only Ethernet Management port information is relevant.
4-14
Chapter 4 Configuration
To display the status of the Ethernet ports: 1. Navigate to Monitoring>Physical Layer and select Ethernet. The Ethernet management port screen is displayed. Monitoring>Physical Layer>Ethernet 1. Device Number 2. Port number Port name Operation Status Max Capability Advertized Alarms > > ... > > > (Local) (MNG-ETH) (MNG-ETH Port) (Up) (100baseTX Full Duplex) (Unmasked)
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Uplink
The Link Status Screen displays the current status of the Uplink port. To display the link status: 1. Navigate to Monitoring>Physical Layer and select Link:
4-15
Chapter 4 Configuration
Optimux-108L Monitoring>Physical Layer>Link 1. Device Number Operation Status Optical Wave Length Fiber Type Connector Type Alarm Indication Test Indication Alarms > > > > > > > > (Local) (Up) (1550nm) (MultiMode) (FC-LH) (Normal) (Off) (Unmasked)
> Please select item <1 to 1> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Figure 4-20. Uplink Status Screen Table 4-6. Uplink Status Parameters
Parameter Device Number Description Identifies the device currently being monitored. Possible Values Local Remote Operation Indicates the current operational status of the device. Up when Uplink synchronized Down when Uplink is not synchronized Optical Wave Length Indicates the Optical Wave Length in nm. 850 nm 1310 nm 1550 nm Not Applicable Fiber Type Indicates the Fiber Type Not Applicable Single Mode Multi Mode Connector Type Alarm Indication Indicates the Connector Type Indicates the highest status level of current alarms. Normal when Uplink synchronized Signal Loss when Uplink is not synchronized. Test Indication Indicates whether a loopback test is currently being run. Identifies whether alarms on the device are masked or not. When masked, Ethernet alarms are not trapped. On Off Masked Unmasked sc, st, fc, scLH, stLH, fcLH Normal Signal loss Up Down
Alarm
4-16
Chapter 4 Configuration
To monitor the status of the uplink: 1. To toggle between the local and remote device, enter 1. The Device Number changes to identify the unit currently being monitored.
E1 Tributary Ports
The E1 port parameters are the same as those in the Uplink Status Screen. For more information, see Figure 4-20. Monitoring>Physical Layer>E1 1. Device Number 2. Port Number [1-4] Operation Status Interface Type Alarm Indication Test Indication Alarm > > > > > > > (Local) (1) (Down) (Balanced) (Signal loss) (Off) (Unmasked)
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Listing Users
The following screen lists information about all users defined in the device. Optimux-108L Configuration>System>Control Port>Device Access>User Information User Name SU Tech USER Access level SU TECH USER Dynamic/Permanent Permanent Permanent Permanent
4-17
Chapter 4 Configuration
USER TECH
Changing a Password
To enhance security, you can specify a password to control access to the Optimux-108L management functions. Pay attention that each line at the Change Password screen (see Figure 4-24) appears only after the previous change. All the instructions appear at the bottom of the screen. The access to the Change Password Screen is according to the next figure: Configuration>System>Control Port>Device Access 1. Change Password 2. User info > []
> Please select item <1 or 2> ESC-Previous menu; !-Main Menu; &-Exit
4-18
Chapter 4 Configuration
. . . >Change Password 1. 2. 3. 4. User Name Password New Password Confirm New Password ... ... ... ... (SU) (****) (****) _-
Note
You must reset the unit in order to activate the new configuration.
1 User(s)
4-19
Chapter 4 Configuration
To view information about the file system: Choose TFTP. The TFTP screen is displayed, Optimux-108L Utilities>File Utilities>File Transfer>TFTP Transfer Status (noOp) Transfer Error (NoError) Command > Local User File Name ... (Put your string here) Remote File Name ... (Put your string here) Server IP ... (0.0.0.0) TFTP Total Timeout (ms)[60 - 240] ... (60)
1. 2. 3. 4. 5.
1 User(s)
1 User(s)
To reset the factory defaults using the System menu: 1. Navigate to Configuration>System and select Factory Default. The Factory Default menu is displayed Figure 4-28.
4-20 Performing Additional Tasks Optimux-108L Ver. 2.0
Chapter 4 Configuration
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 user(s)
Resetting Optimux-108L
You can perform the overall reset of Optimux-108L. To reset Optimux-108L: 1. From the Main Menu, choose Utilities>Reset Device. A confirmation message is displayed. 2. Type Y to confirm the reset.
4-21
Chapter 4 Configuration
4-22
5.1
Optimux-108L/BM
Monitoring Performance
The LRS-102/OP-108C card, fully-managed Optimux-108L or Optimux-108, enable you to monitor the following parameters: Product type (with/without USER-ETH port, balanced/unbalanced tributary ports) Uplink fiber optic type Power supply type Tributary E1 loops Tributary AIS/LOS Uplink loop Uplink AIS/LOS Fault Propagation settings Auto cross detect settings USER-ETH Autonegotiation settings USER-ETH speed USER-ETH link.
When Optimux-108L is connected to the LRS-102/OP-108C card, you can monitor the status of its parameters. Table 5-1 lists the parameters that can be monitored:
Monitoring Performance
5-1
Displays the Optimux-108L device at the far end: OP108 Fully-managed Optimux-108L standalone unit without Ethernet port OP108/ETH Fully-managed Optimux-108L standalone unit with Ethernet port OP108L Optimux-108L/BM standalone unit without Ethernet port OP108L/ETH Optimux-108L/BM standalone unit with Ethernet port
Displays whether Optimux-108L has an Ethernet port: YES the remote device is OP-108L/ETH or OP108/ETH NO the remote device is OP-108L or OP108
Displays the type of the Optimux-108L fiber-optic transceiver: 9 Row transceiver Displays the type of power supply module installed in the PS position of the remote unit: AC AC only PS module is installed. ACDC universal (AC and DC) PS module is installed -48 VDC only the -48 DC PS module is installed
Interface Type
Displays the interface type of remote Optimux-108L E1 ports: Balanced balanced interface Unbalanced unbalanced interface
Displays the enclosure type of the remote Optimux-108L Displays the FPGA version of the remote Optimux-108L Displays the PCB revision of the remote Optimux-108L Displays the alarm status of the port. Normal means normal operation; Major or Minor indicates that an alarm condition with the specified severity has been detected
Test Indication
Displays whether any test is currently active on the remote unit: OFF normal operation (no active test) ON a test is active (LLB or RLB on either E1 channel or uplink)
Displays the Optimux-108L link connector type, for example: LC, SC, SC/APC, FC, etc. Displays the range supported by the transceiver: Short haul or Long haul Displays the nominal operating wavelength of the link (nm) Displays the type of optical fiber for which the link is optimized: Single mode or Multi mode
FO Module
Displays the type of fibers used by the transceiver: Duplex fiber Single fiber
CSL Rev
5-2
Monitoring Performance
Installation and Operation Manual Parameter viewed via LRS-102/OP-108C Switches State Description
Displays the status of the Optimux-108L rear panel switches: FF normal state Any other value DIP switch is active
Note: when Optimux-108L operates opposite the LRS-102/OP-108C card, its rear panel switches are inactive.
Fully-Managed Optimux-108L
You can monitor the following aspects of the Optimux-108L system: System up-time (format: HH:MM:SS) MAC Address Alarms and events Interface status Local system status Remote system status. Optimux-108L Monitoring>System MAC Address Sys Up Time 1. Event Log 2. Active Alarms ... ... [] > [] > (00-20-D2-22-E1-5F) (05:06:34)
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Monitoring Performance
5-3
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Figure 5-2. MNG-ETH Status Screen Table 5-3. MNG-ETH Status Parameters
Parameter Operation Status Description Indicates the current operational status of the device Indicates the speed and duplexity configured for the Ethernet port Possible Values Up Down 100 Mbps Full Duplex 100 Mbps Half Duplex 10 Mbps Full Duplex 10 Mbps Half Duplex Alarm Identifies whether alarms on the device are masked or not. When masked, Ethernet alarms are not trapped Masked Unmasked
2. To see the ETH-USER status, select 2. 3. Select ETH-USER port (2). The USER-ETH screen is displayed.
5-4 Monitoring Performance Optimux-108L Ver. 2.0
Optimux-108L Monitoring>Physical Layer>Ethernet 1. Device Number 2. Port number Port Name Administrative status Operation Status Max Capability Advertized MDIX Auto Cross Over Alarms > > > > > > > (Local) (USER-ETH) (USER-ETH Port) (Up) > (Up) (100baseTX Full Duplex) (Enabled) (Unmasked)
Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
Figure 5-3. USER-ETH Status Screen Table 5-4. USER-ETH Status Parameters
Parameter Administrative status Operation Description Indicates the port status Possible Values Up Down Indicates the current operational status of the device. Indicates the speed and duplexity configured for the Ethernet port. Indicates the status of MDI/MDIX auto cross-cable detection and cross-over Identifies whether alarms on the device are masked or not. When masked, Ethernet alarms are not trapped. Up Down 100Mbps Full Duplex 10Mbps Full Duplex Enabled Disabled Masked Unmasked
Monitoring Performance
5-5
Optimux-108L Monitoring>Physical Layer>Link 1. Device Number Operation Status Optical Wave Length Fiber Type Connector Type Alarm Indication Test Indication Alarms > > > > > > (Local) (Up) (1310nm) (Single Mode) (FC-LH) (Normal) (Off) (Unmasked)
> Please select item <1 to 1> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Figure 5-4. Uplink Status Screen Table 5-5. Uplink Status Parameters
Parameter Device Number Description Identifies the device currently being monitored. Indicates the current operational status of the device. Indicates the Optical Wave Length in nm. Possible Values Local Remote Up Down 850 nm 1310 nm 1550 nm Not Applicable Fiber Type Indicates the Fiber Type Single Mode Multi Mode Connector Type Alarm Indication Indicates the Connector Type Indicates the highest status level of current alarms. Indicates whether a loopback test is currently being run. Identifies whether alarms on the device are masked or not. When masked, Ethernet alarms are not trapped. sc, st, fc, scLH, stLH, fcLH Normal Signal loss On Off Masked Unmasked
Operation Status
Optical Wavelength
Test Indication
Alarm
2. To toggle between the local and remote device, enter 1. The Device Number changes to identify the unit currently being monitored (Local or Remote). 3. To select an E1 port to monitor, enter 2 and then the port number (1 to 4). The screen displays the current status of the selected port on the selected device. Optimux-108L Monitoring>Physical Layer>E1 1. Device Number 2. Port Number [1..4] Operation Status Interface Type Alarm Indication Test Indication Alarm > > > > > > > (Local) (1) (Down) (Balanced) (Signal loss) (Off) (Unmasked)
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
5.2
Optimux-108L/BM
LEDs
Detecting Problems
The status of Optimux-108L operation is indicated by the LED indicators located on the front and rear panels of the unit as well as by the dipswitches located on the unit back panel. For a description of the Optimux-108L front and rear panel LEDs and DIP switch refer to Chapter 3 of this manual.
Alarms
Optimux-108L detects the following alarm conditions on each E1 and uplink interface: Loss of input signal Loss of frame synchronization (on uplink only) Reception of alarm indication signal (AIS) consisting of a continuous sequence of 1s (on the tributary; on the uplink only for products without Ethernet user port).
For the list of Optimux-108L alarms refer to the OP-108C, OP-106C Installation and Operation Manual.
Detecting Problems
5-7
Fully-Managed Optimux-108L
LEDs
The status of Optimux-108L operation is indicated by the LED indicators located on the front and rear panels of the unit. For a description of the Optimux-108L front and rear panel LEDs refer to Chapter 3 of this manual.
Events and alarms are handled via the System Monitoring menu (see Figure 5-6) and described in the following sections. Sys Up Time format is: HH:MM:SS Optimux-108L Monitoring>System MAC Address Sys Up Time 1. Event Log 2. Active Alarms (0020D222E15F) ... (12:06:34) [] []
> Please select item <1 to 2> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
5-8
Detecting Problems
5.3
Handling Events
Displaying Events
The Event log displays up to 1000 events. When the event log buffer is full, each new event replaces the currently oldest event. To access the event log: 1. Navigate to Monitoring>System and select Event Log (see Figure 5-7). The event log displays the source of the event, alarm indicated as the result of the event, its status (ON, OFF) and severity (Major Alarm, Minor Alarm or Event). 2. In the Event Log screen, use the <Ctrl+U> and <Ctrl+D> keys to scroll the alarm list up and down. Optimux-108L Monitoring>System>Event Log Source System Local Link Local Ch-4 Local Device Description DEVISE LOGIN Signal Loss AIS DEVISE LOGIN Status On On On On Sevirity Event Event Major Major SysUpTime 4:15:44 1:41:37 0:07:11 0:00:08
1 2 3 4
1 Mngr/s
Handling Events
5-9
Clearing Events
To clear the event log: 1. From the Event Log menu, Press <C>. A confirmation message appears. 2. Enter Yes to clear the event log buffer.
5-10
Handling Events
Optimux-108L Monitoring>System>Active Alarms Source Local Ch-1 Local Ch-2 Local Ch-3 Local Ch-4 Remote Ch-1 Remote Ch-3 Remote Ch-4 Remote Link Description Signal Loss Signal Loss Signal Loss Signal Loss Signal Loss Signal Loss Signal Loss Signal Loss Severity Status Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked Unmasked
1 2 3 4 5 6 7 8
1 User(s)
Handling Events
5-11
Masking Alarms
You can configure whether various groups of alarms are trapped or not. Optimux-108L Configuration>System>Alarms 1. Device Number 2. Alarms 3. Remote Connection Failed > (Local) (Unmasked) (Unmasked)
> Please select item <1 to 3> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
5.4
Troubleshooting
If a problem occurs, check the displayed indications and refer to Section 3-2 and Table 3-1 for their interpretation. Identify the trouble symptoms and perform the actions listed under Corrective Measures in the order given in Table 5-10, until the problem is corrected.
5-12
Troubleshooting
None of the E1 units connected to a local Optimux-108L receive the signal from the remote equipment
External problem
Defective Optimux-108L Only one of the E1 units connected to a local Optimux-108L does not receive the signal from the remote equipment signal Equipment problem
Defective Optimux-108L
Troubleshooting
5-13
5.5
Testing Optimux-108L/BM
Optimux-108L/BM has comprehensive test and diagnostics capabilities that include local and remote loopbacks on the uplink interface and on each E1 tributary link. Diagnostic loopbacks are configured using the DIP switch located on the Optimux-108L/BM rear panel. The following should be noted with respect to the local and remote loops on Optimux-108L/BM: If a loop is performed by a remote unit, the local unit cannot perform any loop using its local switches until the remote loop is terminated. If a loop is performed on a local unit using its local switches, the remote unit will not be able to perform any loop until the loop on the local unit is terminated.
Note
Optimux-108L/BM does not have a TST LED or other capability to view the loop status. When a loop is performed on a local or remote unit, the corresponding yellow LED (AIS) blinks. For example, if a remote loop is performed on E1 channels 1 and 3, the AIS LEDs of both channels are blinking.
The available loopback functions are described below in this chapter.
Running Loopbacks
Optimux-108L/BM diagnostics capabilities include local and remote loopbacks on each E1 tributary link and Uplink. The loopbacks can be sent by the corresponding LRS-102/OP-108C card, a fully-managed Optimux-108L and an Optimux-108 or generated using the DIP switch of the local or remote Optimux-108L/BM unit. Table 5-11 lists the types of loopbacks available.
+ +
+ + + +
Switch
The Optimux-108L/BM DIP switch is used for performing diagnostic procedures and configuring the USER-ETH port. Switch positions indicate the type of loop performed by Optimux-108L/BM at a given time.
5-14
Testing Optimux-108L/BM
Table 5-12 describes the positions of the switch sections and their meanings. Table 5-12. DIP Switch - Positions and Functions
Switch number 1-4 Function Position Function
E1 Loop
ON
Loop is performed on E1 channels 1-4, respectively. Loop type (remote or local) is determined by switch number 6.
No loop on E1 channels 1-4, respectively. Loop is performed on the Uplink. Loop type (remote or local) is determined by switch number 6.
OFF 6 Loop Type ON OFF 7 Fault Propagation Relevant only when USER-ETH port exist ON
No loop on Uplink RLB loop LLB loop Fault propagation is enabled. When a signal or frame loss is detected on the uplink, the USER-ETH port is shut down on both local and remote units. In an Optimux-108L/BM vs Optimux-108L/BM application, when a signal or frame loss is detected on the uplink, the USER-ETH port shuts down only in the product that the signal or frame loss was detected on.
OFF 8 Auto cross cable detect Relevant only when USER-ETH port exists ON
Fault propagation is disabled. Auto cross cable detect is enabled. Cross or strait cable can be connected, the Ethernet PHY will be adjusted accordingly.
OFF
Testing Optimux-108L/BM
5-15
Figure 5-11 shows the uplink local loopback connection for an Optimux-108L/BM unit without an optional Ethernet user port. Note The diagrams for models with the optional Ethernet user port are similar to Figure 5-11 but do not include AIS on the uplink.
When loopback is activated, the equipment connected to the local Optimux-108L/BM tributary receives its own transmission. In Optimux-108L/BM with an optional USER-ETH port, the port transmission is disabled as Ethernet traffic does not loop back. The test checks the Optimux-108L/BM operation status and the tributary interface connections to other equipment.
Local Optimux-108L
Tributary Interface Tributary Interface Mux /Demux Tributary Interface Tributary Interface
AIS
Uplink Interface
2. Set switch section 5 to ON to activate the Uplink loop. The loopback test runs immediately after the loopback is set.
Figure 5-12 shows the uplink remote loopback connection for an Optimux-108L unit without optional Ethernet user port.
In Optimux-108L with an optional USER-ETH port, the Ethernet traffic is not affected.
5-16
Testing Optimux-108L/BM
The test checks the Optimux-108L operation status and its connection to the remote Optimux-108L.
Local Optimux-108L
Tributary Interface Tributary Interface Mux /Demux Tributary Interface Tributary Interface Uplink Interface Uplink Interface Mux /Demux Tributary Interface Tributary Interface
Remote Optimux-108L
Tributary Interface Tributary Interface
AIS ~
Local Optimux-108L
Tributary Interface
Testing Optimux-108L/BM
5-17
To run a local loopback on an E1 tributary channel: 1. Set switch section 6 to OFF. 2. Set the respective switch section (1 to 4, according to the channel loop required) to ON to activate the E1 tributary loop.
Note
You can simultaneously perform several E1 loops. Each port can be set separately. The loopback test will run immediately after the loopback is set. For instructions on activating the loopback from the LRS-102/OP-108C card, refer to OP-108C, OP-106C Installation and Operation Manual.
Remote Optimux-108L
Tributary Interface
AIS
Uplink Interface
Uplink Interface
Tributary Interface
Tributary Interface
Note
5-18
Testing Optimux-108L/BM
Clearing Loopbacks
To clear a loopback: Set the respective switch section or sections (1 to 5, according to the channel loop) to OFF. The loopback test is discontinued immediately.
5.6
Diagnostic loopbacks are configured and monitored using the Diagnostics menu (see Figure 5-15). Optimux-108L Diagnostics 1. 2. 3. 4. 5. Device Number Link Loop type Link LLB loop Duration (min) [0-255] Channels Loops Clear all channels loops > > ... (Local) (No Loop) (5) [] >
> Please select item <1 to 5> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
Running Loopbacks
Optimux-108L diagnostics capabilities include local and remote loopbacks on each E1 tributary link and uplink. The loopbacks can be originated by the local or remote Optimux-108L unit. In addition, loopbacks can be sent by the corresponding LRS-102/OP-108C card or Optimux-108 product.
Table 5-11 lists the types of loopbacks available. Table 5-13. Optimux-108L Loopbacks
Sent by local Optimux-108L/ Optimux-108 Local loopback on each E1 tributary link Remote loopback on each E1 tributary link Local loopback on Uplink Remote loopback on Uplink Sent by remote Optimux-108L/ Optimux-108 Sent by LRS-102/OP-108C Card
+ + + +
+ + + +
+ + + +
5-19
Figure 5-16 shows the uplink local loopback connection for an Optimux-108L unit
without an optional Ethernet user port.
Note
The diagrams for models with the optional Ethernet user port are similar to Figure 5-16 but do not include AIS on the uplink.
When loopback is activated, the equipment connected to the local Optimux-108L tributary receives its own transmission. In Optimux-108L with an optional USER-ETH port, the port transmission is disabled as Ethernet traffic does not loop back. The test checks the Optimux-108L operation status and the tributary interface connections to other equipment.
Local Optimux-108L
Tributary Interface AIS
~
Tributary Interface Mux /Demux Tributary Interface Uplink Interface
Tributary Interface
Figure 5-17 shows the uplink remote loopback connection for an Optimux-108L
unit without optional Ethernet user port. In Optimux-108L with an optional USERETH port, the Ethernet traffic is not affected. The test checks the Optimux-108L operation status and its connection to the remote Optimux-108L.
5-20
~
Uplink Interface Uplink Interface
Caution Setting the Uplink Local Loopback (LLB) in the remote Optimux-108L disconnects
the link, and as such, is irreversible. To remove this loopback, connect a terminal to the remote unit or shut down the power to the remote unit. If you set the Uplink LLB timeout on the remote Optimux-108L, the loopback test will stop after the specified timeout period.
5-21
~ Tributary Interface
AIS
Local Optimux-108L
Tributary Interface
Remote Optimux-108L
Tributary Interface
AIS
Tributary Interface Mux/Demux Tributary Interface Uplink Interface Uplink Interface Mux/Demux
Tributary Interface
Tributary Interface
Tributary Interface
Tributary Interface
5-22
Optimux-108L Diagnostics>Channels Loop 1. 2. 3. 4. E1 E1 E1 E1 Channel Channel Channel Channel 1 2 3 4 > > > > (No (No (No (No loop) loop) loop) loop)
> Please select item <1 to 4> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
4. Select the loopback status you want to set: No loop - No loopback on the channel LLB - Local loopback on the channel RLB - Remote loopback on the channel.
Note
Clearing Loopbacks
To clear a specific loopback: Select No loop in the specific loopback screen. The loopback test is disconnected immediately after this option is selected. To clear all loopbacks: 1. From the Diagnostics menu, select Clear all channels loops. All the loopback tests are disconnected immediately after this option is selected.
5.7
Q A
Is Optimux-108L fiber main link line coding compliant with NRZ? Optimux-108L does not comply with NRZ. The fiber optic interface line code is scrambled NRZ. The fiber optic module is RAD proprietary, and cannot work opposite other vendors.
5-23
5.8
Technical Support
Technical support for this product can be obtained from the local authorized RAD partner from whom it was purchased. For further information, please contact the authorized RAD partner nearest you or one of RAD's offices worldwide. This information can be found at www.rad.com (offices About RAD > Worldwide Offices; distributors Where to Buy > End Users).
5-24
Technical Support
6.1
Impact
Optimux-108L resets automatically after the software upgrade, resulting into up to two minutes of downtime. Upgrade to new version does not affect any user settings.
6.2
Application software can be downloaded to Optimux-108L via the TFTP menu: Main Menu > Utilities > File Utilities > File Transfer > TFTP.
6.3
Prerequisites
This section details the Optimux-108L software and versions compatible with the new version. It also lists the software file names and outlines system requirements needed for the upgrade procedure.
Prerequisites
6-1
Software Files
The new version releases are distributed as software files named OP-108L.img. The files can be obtained from the local RAD business partner from whom the device was purchased.
System Requirements
Before starting the upgrade, verify that you have the following: For upgrade via TFTP: Operational Optimux-108L unit with valid IP parameters configured for the host Connection to a PC with a TFTP server application (such as 3Cdaemon or PumpKIN), and a valid IP address Software file (OP-108L.img) stored on the PC
6.4
The recommended software downloading method is downloading by means of the TFTP, using the Download/upload using TFTP menu reached from the File Utilities menu. Network administrators can use this procedure to distribute new software releases to all the managed Optimux-108L units in the network from a central location. To download the new software release to Optimux-108L via the File Utilities menu: 1. Verify that the OP-108L.img is stored on the PC with the TFTP server application. 2. Verify that the Optimux-108L host has valid IP parameters. 3. Ping the PC to verify the connection. 4. Activate the TFTP server application. 5. Download the OP-108L.img from the PC to Optimux-108L.
Note
6-2
To verify the Optimux-108L host parameters: Display the Host IP menu (Configuration > System > Management > Host), and verify that the host IP address, IP mask and default gateway are configured according to your network requirements. Optimux-108L Host IP address IP mask default gateway Read community Write community Trap community (172.17.161.73) (255.255.255.0) (172.17.161.1) (public) (public) (public)
6-3
New software releases are distributed as an *.img file, which is downloaded to the local Optimux-108L using the TFTP protocol. Upon downloading, the new software release becomes active, the former active software turns into backup, and the former backup is erased. If a failure occurs during downloading or decompression, the new version is erased from the flash and the backup version becomes active. In this case, only one version is left stored in the flash memory. If the active software becomes corrupted, you can replace it with its backup. This procedure is used to replace the current software version with the new software release (OP-108L.img).
1. 2. 3. 4. 5.
> Please select item <1 to 5> ESC-Previous menu; !-Main Menu; &-Exit
1 User(s)
6-4
Possible Values No error Error resources Error timout Error use msg Error nofile Error acceess Error disk full Error illegal op Error bad tid Error exists Error no user
Description Error code when Transfer Status is Error. This parameter provides specific details of the error that occurred while attempting to download the file. This parameter is set to No error unless an error is detected.
Command
No Operation Software Download Software Upload Configuration File Download Configuration File Upload
Downloads software from the server Uploads current software version to the server
Name of the file to download from server or upload to server. IP address of the server to which the file will be uploaded or downloaded.
3. Choose Remote File Name and enter the name of the file you want to download. 4. Choose Command and then choose Software download. The download process begins. The Transfer Status field indicates the current status of the download. 5. After the decompression, Optimux-108L is automatically reset. This causes the new software to be loaded into the modem's RAM.
Note
After the unit reboots, you must open a new Telnet session.
6-5
6-6
7.1
Transparent services and clocks are enabled by connecting two Optimux-108L units over fiber. After installation, there are no special configuration procedures to be performed; the services and clocks over fiber are enabled automatically.
Equipment List
The following devices and network equipment are used to enable transparent services and clocks over fiber:
Optimux-108L Ver. 2.0
Two Optimux-108L units (local and remote) Two gateway routers (depending on the application) Up to 4 E1 tributary interfaces One Ethernet interface AC or DC power cable, depending on the ordering option RM-33-2 rack-mount kit, if ordered (depending on user requirements) Fiber optic cables RJ-45 E1 connector cables RJ-45 Ethernet connector shielded cable category 5.
Configuring Transparent Services over Fiber 7-1
Note
1. SF1 connector must work opposite SF2 and not opposite the same type of link. 2. For the WDM option, only one fiber optic cable per link should be connected.
7-2
4. Connect the USER-ETH ports of both units to routers using the shielded CAT5 cable.
7.2
7-3
Equipment List
The following devices and network equipment are used in the Optimux-108L applications: Two Optimux-108L units (local and remote) Two gateway routers (depending on the application) Up to 4 E1 tributary interfaces One Ethernet interface AC or DC power cable, depending on the ordering option RM-33-2 rack-mount kit, if ordered (depending on user requirements) Fiber optic cables RJ-45 E1 connector cables RJ-45 Ethernet connector shielded cable category 5 Management station with Telnet, Web Server or SNMP application.
7-4
4. Using a shielded CAT5 cable, connect the management station to the MNG-ETH connector. See Figure 7-11 for details.
Note
Note
7-6
4. Configure the Masking of the Physical Layer parameters independently for each parameter: MNG-ETH, E1, Link, USER Ethernet (the paths of these parameters appear in steps 1 to 4).
7-7
7-8
The pinout of both Ethernet connectors (MNG-ETH and USER-ETH) is the same and listed in Table A-1.
A.2
The tributary interface has four E1 RJ-45 connectors (for the balanced link interface) or four dual BNC connectors (for the unbalanced interface). The pin assignment of the E1 RJ-45 connector is given in Table A-2.
A-1
A-2
Supplement
To prepare the AD plug and connect it to the DC power supply cable: 1. Loosen the cover screw on the bottom of the AD plug to open it (see Figure 3). 2. Run your DC power supply cable through the removable cable guard and through the open cable clamp. 3. Place each DC wire lead into the appropriate AD plug wire terminal according to the voltage polarity mapping shown. Afterwards, tighten the terminal screws closely. 4. Fit the cable guard in its slot and then close the clamp over the cable. Tighten the clamp screws to secure the cable. 5. Reassemble the two halves of the AD plug and tighten the cover screw. 6. Connect the assembled power supply cable to the unit.
Note: You have to flip over the non-90-degree AD plug type by 180 degrees to insert it into the unit. After inserting it, verify that the blue (negative) wire is connected to the POWER and the brown (positive) wire is connected to the RETURN.
Reversing the wire voltage polarity will not cause damage to the unit, but the internal protection fuse will not function.
Warning
Always connect a ground wire to the AD plugs chassis (frame) ground terminal. Connecting the unit without a protective ground, or interrupting the grounding (for example, by using an extension power cord without a grounding conductor) can damage the unit or the equipment connected to it! The AD adapter is not intended for field wiring.
24 Raoul Wallenberg Street, Tel Aviv 69719, Israel Tel: +972-3-6458181, Fax: +972-3-6498250 E-mail: erika_y@rad.com, Web site: http://www.rad.com
Excellent
Installation instructions Operating instructions Manual organization Illustrations The manual as a whole
Good
Fair
Poor
Very Poor
Error Report
Type of error(s) or problem(s): Incompatibility with product Difficulty in understanding text Regulatory information (Safety, Compliance, Warnings, etc.) Difficulty in finding needed information Missing information Illogical flow of information Style (spelling, grammar, references, etc.) Appearance Other Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.) and attach the page to your fax, if necessary.
You are:
Who is your distributor? Your name and company: Job title: Address: Direct telephone number and extension: Fax number: E-mail:
International Headquarters
24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com
www.rad.com