Sunteți pe pagina 1din 2

PIT DETAIL FOR MP MECHANICAL & HP and H SERIES (Autodok) HYDRAULIC DOCK LEVELERS

ANCHOR LAYOUT FOR CURB ANGLES

12

12

12

12

3
Disconnect (by others)

Dim. B
Tolerance 1/8

DOCK FLOOR

10 14
C L

Concrete anchors 1/4 thick x 1 wide x 6 long (Alternate direction of each J hook anchor)
Dim. A
Tolerance -1/4 +0

3 3

C L
90

b pit of lum ar be p Re ust m Dim. C


Tolerance 1/8

Dim. E
Tolerance 1/8

Hydraulic and electric units only Set () conduit and recessed weatherproof receptacle (4 x 4 junction box) and cover (by others) before pouring concrete

Control Panel (inside wall) for hydraulic and electric units only

L WA

Dim. D
Tolerance 1/8

90

NOTE: Tolerances: 1/8 in depth, width and squareness -1/4 +0 in length pitch toward front of pit for drainage. All curb angle joints to be welded completely. Levelers to be stitch welded to rear pit steel with 6 on and 6 off weld pattern, for further instructions request an installation manual. Side curb angles must be 90 to dock face and rear curb. Concrete behind Pit Steel must be well vibrated. 8 recommended minimum thickness for pit walls, pit floor and dock face. For dock heights under 44 or over 52 consult factory. For decline slope drive condition, consult field sales representative. Pit steel furnished by general contractor or available from the manufacturer at additional cost.

Optional CleanPit for VH Series

C L

Pitch from rear to front

AL W

Optional vehicle restraint mounting plate & conduit locations - consult factory

For Declined Slope Drives


See pit projection guide on back

DR

O PR AP Y WA IVE

AC

PUERTAS AUTOMATICAS DE VERACRUZ SA DE CV


TEL: (01 229) 922 00 84 922 00 85 921 92 94

puertasautomaticasdeveracruz@prodigy.net.mx
CONTACTO: MAGALI SANTA ROSA GONZALEZ

PD MP, HP, H 11/06

CLIENTE: WALMART MEXICO MODELO: HP 6830 6'X8' 30,000LBS

Pit dimensional tolerances are 1/8 in depth, width and squareness, - +0 in length. McGUIRE/Systems, Inc. assume no liability for deviations beyond this tolerance.
Dimensions below are for all MP Series Mechanical and HP and H Series Hydraulic pit type levelers, all capacities, except 75K Comparative Industry Rating (CIR) leveler - Dim. C is 23 and Dim. D is 24.

Contractors Bill Of Material Curb Angles " x 3" x 3" Front Rear (Qty Side (Qty 1) 1) (Qty 2) 6' x 6 6.5' x 6' 7' x 6' 6' x 8' 6.5' x 8' 7' x 8' 6' x 10' 6.5' x 10' 7' x 10' 6' x 12' 6.5' x 12' 7' x 12' 74" 80" 85" 74" 80" 85" 74" 80" 85" 74" 80" 85" 80" 86" 91" 80" 86" 91" 80" 86" 91" 80" 86" 91" 60" 60" 60" 84" 84" 84" 108" 108" 108" 132" 132" 132" Mounting Plates " Thick
Face (Qty 2) *CleanPit Embed (Qty 1)

Nominal Pit Dimensions Dim. "A" Length 63" 63" 63" 87" 87" 87" 111" 111" 111" 135" 135" 135" Dim. "B" Width 74" 80" 85" 74" 80" 85" 74" 80" 85" 74" 80" 85" Dim. "C" Depth (rear) 19" 19" 19" 19" 19" 19 23" 23" 23" 23" 23" 23" Dim. "D" Depth (front) 20" 20" 20" 20" 20" 20" 24" 24" 24" 24" 24" 24"
Consult Manufacturer

Dim. "E" Clean Pit


(H Series)

20 20 20 20 20 20 24 24 24 24 24 24

16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16"

20 20 20 30 30 30 48 48 48

*Weldment is required ONLY for clean pit style leveler. Optional Bumper Plates - in lieu of above
q q q q 3 x 14 wide x 12 high (Qty 2) 3 x 11 wide x 20 high (Qty 2) 3 x 11 wide x 24 high (Qty 2) Other Bumper Embed ___________________ (Qty 2)
ANCHOR LAYOUT FOR BUMPER MOUNTING PLATE (14 x 12)
3

45

12

12

14

Pit Projection Guide for Decline Slope Driveways


Percentage Of Grade = Rise of Driveway Driveway Length
% of Driveway Grade Pit Projection *Excludes Bumper Projection 0% 0" 1% 3" 2% 4" 3% 5" 4% 6" 5% 7"

Example

6% 8"

7% 9"

8% 10"

9% 11"

10% 12"

NOTE:

Projection of pit may require modifications to seals and shelters. Coordinate with supplier if required.
Model VB420-11F 10 3/8 Model VB424-11F 10 3/8

Bumper Layout
Model B410-14F Model DB 12 x 13
13 9 2

13 3/8
2 3/8 7 1/4 12

PUERTAS AUTOMATICAS DE VERACRUZ SA DE CV


10

puertasautomaticasdeveracruz@prodigy.net.mx 23 1/2
CONTACTO: MAGALI SANTA ROSA GONZALEZ
4 1/2 4 1/2

TEL: (01 229)19 1/200 84 922 00 85 921 92 94 922

Bumper Consideration q 2 Model DB 12 x 13


Molded bumpers Standard on MP, HP Series, and H Autodok Levelers (Less than 75k)

q 2 Model B410-14F
laminated bumpers q Optional - 6 Projection Standard on H Series 75K and 100K Levelers q Optional - Steel face

CLIENTE: WALMART MEXICO q q 2 Model VB420-11F MODELO: HP 6830 6'X8' 30,000LBS laminated bumpers
q Optional - 6 Projection q
Optional - Steel face

4 1/2

2 Model VB424-11F laminated bumpers q Optional - 6 Projection

q Optional - Steel face

A continuing product improvement process is in effect at Systems, Inc. We reserve the right to make product changes without prior notice.

McGUIRE Division of Systems, Inc. W194 N11481 McCormick Dr. Germantown, WI 53022 800.643.5424 fax: 262.255.9399 www.DockSystemsInc.com