3
Disconnect (by others)
Dim. B
Tolerance 1/8
DOCK FLOOR
10 14
C L
Concrete anchors 1/4 thick x 1 wide x 6 long (Alternate direction of each J hook anchor)
Dim. A
Tolerance -1/4 +0
3 3
C L
90
Dim. E
Tolerance 1/8
Hydraulic and electric units only Set () conduit and recessed weatherproof receptacle (4 x 4 junction box) and cover (by others) before pouring concrete
Control Panel (inside wall) for hydraulic and electric units only
L WA
Dim. D
Tolerance 1/8
90
NOTE: Tolerances: 1/8 in depth, width and squareness -1/4 +0 in length pitch toward front of pit for drainage. All curb angle joints to be welded completely. Levelers to be stitch welded to rear pit steel with 6 on and 6 off weld pattern, for further instructions request an installation manual. Side curb angles must be 90 to dock face and rear curb. Concrete behind Pit Steel must be well vibrated. 8 recommended minimum thickness for pit walls, pit floor and dock face. For dock heights under 44 or over 52 consult factory. For decline slope drive condition, consult field sales representative. Pit steel furnished by general contractor or available from the manufacturer at additional cost.
C L
AL W
Optional vehicle restraint mounting plate & conduit locations - consult factory
DR
O PR AP Y WA IVE
AC
puertasautomaticasdeveracruz@prodigy.net.mx
CONTACTO: MAGALI SANTA ROSA GONZALEZ
Pit dimensional tolerances are 1/8 in depth, width and squareness, - +0 in length. McGUIRE/Systems, Inc. assume no liability for deviations beyond this tolerance.
Dimensions below are for all MP Series Mechanical and HP and H Series Hydraulic pit type levelers, all capacities, except 75K Comparative Industry Rating (CIR) leveler - Dim. C is 23 and Dim. D is 24.
Contractors Bill Of Material Curb Angles " x 3" x 3" Front Rear (Qty Side (Qty 1) 1) (Qty 2) 6' x 6 6.5' x 6' 7' x 6' 6' x 8' 6.5' x 8' 7' x 8' 6' x 10' 6.5' x 10' 7' x 10' 6' x 12' 6.5' x 12' 7' x 12' 74" 80" 85" 74" 80" 85" 74" 80" 85" 74" 80" 85" 80" 86" 91" 80" 86" 91" 80" 86" 91" 80" 86" 91" 60" 60" 60" 84" 84" 84" 108" 108" 108" 132" 132" 132" Mounting Plates " Thick
Face (Qty 2) *CleanPit Embed (Qty 1)
Nominal Pit Dimensions Dim. "A" Length 63" 63" 63" 87" 87" 87" 111" 111" 111" 135" 135" 135" Dim. "B" Width 74" 80" 85" 74" 80" 85" 74" 80" 85" 74" 80" 85" Dim. "C" Depth (rear) 19" 19" 19" 19" 19" 19 23" 23" 23" 23" 23" 23" Dim. "D" Depth (front) 20" 20" 20" 20" 20" 20" 24" 24" 24" 24" 24" 24"
Consult Manufacturer
20 20 20 20 20 20 24 24 24 24 24 24
16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16" 16" x 16"
20 20 20 30 30 30 48 48 48
*Weldment is required ONLY for clean pit style leveler. Optional Bumper Plates - in lieu of above
q q q q 3 x 14 wide x 12 high (Qty 2) 3 x 11 wide x 20 high (Qty 2) 3 x 11 wide x 24 high (Qty 2) Other Bumper Embed ___________________ (Qty 2)
ANCHOR LAYOUT FOR BUMPER MOUNTING PLATE (14 x 12)
3
45
12
12
14
Example
6% 8"
7% 9"
8% 10"
9% 11"
10% 12"
NOTE:
Projection of pit may require modifications to seals and shelters. Coordinate with supplier if required.
Model VB420-11F 10 3/8 Model VB424-11F 10 3/8
Bumper Layout
Model B410-14F Model DB 12 x 13
13 9 2
13 3/8
2 3/8 7 1/4 12
puertasautomaticasdeveracruz@prodigy.net.mx 23 1/2
CONTACTO: MAGALI SANTA ROSA GONZALEZ
4 1/2 4 1/2
q 2 Model B410-14F
laminated bumpers q Optional - 6 Projection Standard on H Series 75K and 100K Levelers q Optional - Steel face
CLIENTE: WALMART MEXICO q q 2 Model VB420-11F MODELO: HP 6830 6'X8' 30,000LBS laminated bumpers
q Optional - 6 Projection q
Optional - Steel face
4 1/2
A continuing product improvement process is in effect at Systems, Inc. We reserve the right to make product changes without prior notice.
McGUIRE Division of Systems, Inc. W194 N11481 McCormick Dr. Germantown, WI 53022 800.643.5424 fax: 262.255.9399 www.DockSystemsInc.com