Documente Academic
Documente Profesional
Documente Cultură
Philips innovative and reliable UV lamp systems for water and air disinfection
Content overview
4-5 6-7 8-9 10 - 15 Integrated UV Modules Residential water and air purification TUV PL-S TUV TL Mini 16 - 25 Municipal and industrial water purification TUV Amalgam XPT System DynaPower System Medium Pressure Mercury TUV T5 26 - 33 Commercial and Professional air purification TUV PL-L TUV PL-L Intelligent TUV T8 34 - 35 The right driver for the right lamp Knowing youre safe
Innovation Our comprehensive portfolio of UV lamp and driver systems is always on the forefront of innovation. Just think of the eXtreme Power Technology (XPT) amalgam systems that contain high wattages of low pressure lamps, resulting in amazing power which allows even more flexibility in system design and application. Our latest innovation that changes the world of water disinfection is called InstantTrust. This cutting-edge disinfection technology allows for the first time to disinfect water instantly and independently of water temperature.Evidently, we work closely with our customers to develop and produce these cutting-edge solutions, creating tailor-made lamp systems when required.
Reliability To achieve the best performance from any installation, the delicate balance and interaction between lamp and driver needs to be optimized. We are the only manufacturer that offers a complete in-house manufactured package of lamps and drivers, ensuring the ultimate performance. Evidently, all our products are tested to the most stringent standards to ensure they provide the ultimate quality, reliability and performance. Partnership When you choose Philips as a partner, you can be sure that we take complete responsibility for the system performance and reliability. You deal with one supplier for the total system. This helps to avoid compatibility failures and makes life easier for you.
Sustainability Sustainability has always been at the heart of Philips. Were leading the way towards systems that improve quality of life of people around the world with minimum environmental impact: Its estimated that absence of a safe water supply contributes to 80% of diseases and deaths in the developing world. With its UV lamp systems, Philips helps provide safe drinking water and air in a cost-effective way. Philips UV solutions contribute to a better environment, because they substitute potentially dangerous chemicals. Moreover our products contain industry-leading low amounts of mercury, help reduce waste thanks to their long lifetime and reduce energy use thanks to their high efficacy. You can recognize our most sustainable products by the Green Logo. The Green Logo is only awarded when the product offers a significant environmental improvement.
UV technology Ultra-Violet (UV) radiation is invisible to human eyes. It can be subdivided into three categories, UVA, UVB and UVC. UVC radiation is known to break the DNA of bacteria, viruses and spores. As a result, they are rendered harmless. UV radiation can be used for multiple purposes in water and air treatment, but is primarily employed as a disinfection process that inactivates micro-organisms without chemicals. For other applications, UV is used for the removal of organic and inorganic chemicals, including chlorine, chloramines, ozone and Total Organic Carbon (TOC) emerging contaminants. Benefits of UV are: Effective for all types of microorganisms, including bacteria, viruses, fungi, and protozoa such as Cryptosporidium and Giardia No disinfection by-products (DBPs) of health concern formed UVC acts instantly Low capital and operating cost Easy to operate and maintain Does not change the taste of water Safe and environmentally-friendly No overdose issues and dose can be easily adapted to specific needs
Cutting-edge disinfection technology Philips InstantTrust breaks new ground, overcoming four key limitations of existing low pressure UV lamps: Size: It is half the size or less of existing disinfection functions, which means it can be built into almost any POU application, from fixed taps to portable pitchers. Run-up time: It provides an instant start with no run-up period. As a result, water can be disinfected just before it's served. Fig. 1 Temperature sensitivity: It can be used for both cold (4C) and hot water applications an industry first thanks to its constant performance at all temperatures. Fig. 2
Fig. 2
Fig. 1
A broad range of applications InstantTrust is ideal for applications that require instant disinfection of small quantities of water (up to 4 liters / minute). It is ideally suited for water dispensing equipment such as bottle refill stations, table top purifiers and other Point-of-Use equipment.
The InstantTrust is customized to the manufacturers water dispensing equipment as part of a careful design-in process to make sure that it provides the desired performance. For more information, please contact your sales representative or visit our web site www.philips.com/uvpurification
Integrated UV modules
In addition to our extensive range of individual UV lamps and drivers for water and air purification systems, we offer integrated UV modules on a project by project basis. These integrated modules can be tailored to best match your requirements both in terms of ergonomics and functionality.
Designed for optimal performance By integrating the lamp and driver we can ensure maximum compatibility between these different components. As a result the delicate balance and interaction between these components is optimized, allowing for the best performance and efficiency of the complete UV lamp system. Application and technological expertise Philips Lighting has been closely associated with the progress in UVC technology by developing,
manufacturing and marketing UVC lamp systems. Thanks to our deep understanding of the complex factors that need to be taken into account for water and air purification (including quality of the water, water flow and water temperature), we believe we are the best partner for the design of UV modules that are optimized for your application. To learn more about how our integrated modules could benefit you, go to www.philips.com/uvpurification
10
Features Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes Protective inside coating ensures almost constant UV output over the complete lifetime of the lamp Special lamp glass filters out the 185 nm ozone-forming radiation 2-Pin PL-S lamp base contains a special starter for almost instant starting on electromagnetic drivers 4-Pin PL-S lamps are designed for use on electronic drivers Warning sign on lamp indicates that the lamp radiates UVC
Benefits Effective disinfection over the useful lifetime of the lamp High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection Good environmental choice because of lowest amount of mercury
12
Technical data
Type CapBase Dim. Technical Lamp no Lamp Voltage Wattage (W) (V) 1 2 3 4 5 6 7 5.5 5.1 7.1 8.6 8.6 11.6 11.6 13.0 35 27 46 60 60 89 89 56 UVC at 100h (W) 1 1 1.5 2.2 2.2 3.2 3.5 3.4 Lamp Current (A) 0.18 0.19 0.18 0.17 0.17 0.16 0.16 0.29 Useful life (h) 9000 9000 9000 9000 9000 9000 9000 9000 Depreciation Packaging Packaging at useful type configulifetime ration (%) 20 15 20 20 20 20 20 20 1CT 1CT 1CT 1CT 1CT 1CT 1CT 1CT 6x10BOX 5x10CC 5x10CC 6x10BOX 6x10BOX 6x10BOX 6x10BOX 6x10BOX Ordering number 12 NC 5W/2P 5W/4P 7W/2P 9W/2P 9W/4P 11W/2P 11W/4P 13W/2P G23 2G7 G23 G23 2G7 G23 2G7 927900504007 927900804007 927901104007 927901704008 927901904007 927902304007 927902404007 927902804007
GX23 8
D1
D1
D1
G23 Dim.* A no. 1 3 4 6 max. 67 97 129 198 B max. 83 145 C max. 105 167 D max. 28 28 28 D1 max. 13 13 13 13 Dim.* A no. 2 5 7 max. 65,2 129 198 B max. 83 145
213,3 219,9 28
Dimensions (mm)
13
Features Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes Protective inside coating ensures almost constant UV output over the complete lifetime of the lamp Special lamp glass filters out the 185 nm ozone-forming radiation Warning sign on lamp indicates that the lamp radiates UVC
Benefits Effective disinfection over the useful lifetime of the lamp High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection Good environmental choice because of lowest amount of mercury
14
Technical data
Type Cap-Base Dim. Technical Lamp no Lamp Voltage Wattage (W) (V) 1 2 3 2 4 5 6 4 6 8 11 15 20 25 6 11 15 20 25 29 42 56 26 43 45 55 42 26 43 45 55 UVC Lamp Useful Depreciation Packaging Packaging at Current life at useful type configu100h lifetime ration (W) (A) (h) (%) 0.9 1.5 2.4 2.6 4.0 6.0 7.2 1.7 2.6 4.0 6.0 8.0 0.17 0.16 0.15 0.43 0.40 0.45 0.45 0.16 0.43 0.40 0.45 0.45 6000 9000 20 20 1FM 1FM 1FM 1FM 1FM 1FM 1FM UNP UNP UNP UNP UNP Ordering number 12 NC 4W 6W 8W 11W 16W 20W 25W 6W 4P SE 11W 4P SE 16W 4P SE 20W 4P SE 25W 4P SE G5 G5 G5 G5 G5 G5 G5 10x25BOX 928000104013 10x25BOX 928000704013 10x25BOX 928001104013 10x25BOX 928002204013 10x25BOX 928002004013 10x25BOX 928003404013 10x25BOX 928002604013 32 32 32 32 32 927971604099 927971204099 927971404099 927973404099 927972204099
4 Pins Single Ended 7 4 Pins Single Ended 8 4 Pins Single Ended 9 4 Pins Single Ended 10 4 Pins Single Ended 11
11000 15 9000 20
A B C
A C
G5
B min.
B max.
C max.
D max.
Dim. no. 7 8 9 10 11
A max.
C max.
D max. 19 19 19 19 19
135.9 140.6 143.0 150.1 16 212.1 216.8 219.2 226.3 16 283.3 293.0 295.4 302.5 16 288.3 293.0 295.4 302.5 16 398.0 402.7 405.1 412.2 16 516.9 521.6 524.0 531.1 16
244.1 251.8 244.1 251.8 320.3 328.0 430.0 437.7 548.9 556.6
*
Dimensions (mm)
15
16
Features Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection Special amalgam used for highest efficiency over wide temperature range Protective inside coating ensures constant UV output over the complete lifetime of the lamp Philips electronic driver available for a perfect interface
Benefits Effective disinfection over the useful lifetime of the lamp Approximately 10% energy savings, because lamps can be dimmed to reach the same UV output compared to similar lamps on the market High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection Best environmental choice because of long reliable life, less waste and industry leading low amount of mercury Extreme reliability of driver, with annual failure rate of less than 1% High efficiency during dimming thanks to unique amalgam temperature control of the 800W lamps
Minimized amount of mercury Universal burning position possible for the T6 range, depending on lamp type and sleeve dimensions Tailor-made solutions possible Lamp can be made from special quartz (open / synthetic) to maximize 185nm Ozone generation
18
Technical data
Lamp type Cap base Dim. no 1 2 3 4 5 6 Technical Lamp Lamp Useful life UVC 1 UVC 1 Wattage Voltage Current at 0h at 100h (W) (W) (W) (W) (W) (W) 140 180 200 305 275 815 67 90 94 160 78 103 2.1 2.1 2.1 2.0 3.6 8.0 12000 12000 12000 12000 12000 12000 46 63 66 114 96 273 44 60 63 108 91 254 Depreciation at Ordering useful lifetime number (%) 12 NC 15 15 15 15 15 15 928101805112 928106805112 928106905112 928107005112 928101705112 928107605112 TUV 130W XPT SE TUV 180W XPT SE TUV 200W XPT SE 4 Pins Single Ended 4 Pins Single Ended 4 Pins Single Ended
TUV 325W XPT HO SE 4 Pins Single Ended TUV 330W XPT SE TUV 800W XPT SE
1
Lamp type
Driver
TUV 130W XPT SE TUV 180W XPT SE TUV 200W XPTSE TUV 325W XPT HO SE TUV 330W XPT SE TUV 800W XPT SE
TUV 130W XPT driver TUV 180-200W XPT driver TUV 180-200W XPT driver
TUV 325W XPT (HO) driver 10054995 TUV 800W XPT driver Prototype
Dim.* no. 1 2 3 4 5 6
A nom. 19 19 19 19 32 38
Dimensions (mm)
19
Features Operates 230W, 260W and 335W TUV Amalgam XPT lamps Single lamp operation possible Cooler operating temperature for additional energy savings 100% stress testing minimizing 0-hour failures
Benefits The highest levels of service and support with a single supplier for lamp and driver 3-year guarantee on driver and 12,000 operating hours guarantee on lamp* Energy cost savings of approximately 10% compared with similar drivers or lamps Dimmable up to 60% power level for additional energy savings Easier maintenance thanks to single lamp operation, allowing to detect easily which lamps need to be replaced Best environmental choice thanks to maximum lifetime reliability, in combination with minimum substances, packaging and product weight Easier to maintain compliance with regulations thanks to reduced risk of failures
Approximately 20 seconds start-up time (compared with 90 seconds for similar drivers on the market)
20
Technical data
Lamp type Cap-Base Technical Wattage (W) Lamp Useful life Voltage (V) (h) 88 76 77 77 12000 12000 12000 12000 UVC 1 at 0h (W) 78 80 94 94 UVC 1 at 100h (W) 76 78 89 89 Depreciation Ordering number at useful lifetime (%) 12 NC 15 15 15 15 928104005112 928102805112 928103105112 928105705112 TUV 230W WE XPT SE TUV 260W XPT DIM TUV 335W XPT SE TUV 335W WP XPT SE
1
4 Pins Single Ended 230 4 Pins Single Ended 222 4 Pins Single Ended 293 4 Pins Single Ended 293
Lamp type
Driver
TUV 230W WE XPT SE TUV 260W XPT DIM TUV 335W XPT SE TUV 335W WP XPT SE
4 Pins Single Ended Dimensions TUV 260W XPT DIM TUV 335W XPT SE A 32 32 B 1400 1400 1400 1400 C 1514 1514 1514 1514
21
Spectral output The lamps emit a wide band spectrum in the UVC range. In contrast to Low Pressure lamps, considerable amounts of radiation around the 254 nm is emitted. The power density is very high compared with Low Pressure lamps. Lamps can be made in special quartz to either substantially lower the emission below 240 nm, or to maximize radiation at 185 nm. The former type is used in installations where nitrite formation must be avoided; the latter type is used in installations for ozone production or advanced oxidation.
Operation Philips Medium Pressure Mercury lamps can be tailored to operate on conventional electromagnetic or electronic drivers. Lamps in special frames for single ended operation are available on request. A permissible bulb temperature for HOK type lamps is in the 600 900 C range, for HTK type lamps 500 700 C. Permissible pinch temperature is 300 C, higher pinch temperatures up to 420 C are possible using the Philips patented Pinch Protection.
Philips HOK: Maintenance relation between UVC output and burning time
100% 100%
Philips HOK: Maintenance relation between UVC output and burning time
UVC output in %
UVC output in %
80% 60% 40% 20% 0% 0 1000 2000 3000 4000 5000 6000 7000
Wavelength in nm
22
Technical data
Type Tube diameter mm 22 22 22 22 22 22 22 22 22 25 14 14 Arc length mm 105 195 250 350 500 650 800 1050 1400 550 700 700 Technical Lamp Lamp Voltage Wattage max typical (W) (V) 1100 2100 2900 4200 6000 7800 9600 13000 16800 8700 2000 4000 130 240 420 490 670 840 1030 1300 1850 430 1400 1400 Lamp Current UVC typical at 100h (A) (W) 8.5 9.5 7.0 8.5 8.8 9.2 9.2 9.4 9.0 20.0 1.6 3.1 140 250 380 520 750 1000 1200 1600 2100 1130 160 310 Irradiance muW/cm2 1400 2500 3800 5200 7500 10000 12000 16000 21000 11300 1600 3100 HOK 10/120 HOK 20/100 HOK 25/120 HOK 35/120 HOK 50/120 HOK 65/120 HOK 80/120 HOK 105/120 HOK 140/120 HOK 50/180 HTK 7/30 HTK 7/60
Note: bulb diameters for HOK lamps are typically around 22 mm nominal for 120W/cm lamps. For lamp loading up to 180W/cm, the bulb diameters is around 27.5mm. HTK bulb diameters are 14mm nominal. Standard lamps are available (contact our sales department for details), different dimensions are available on request.
23
Philips TUV T5
TUV T5 lamps are single- or double-ended UVC (germicidal) lamps used in professional water and air disinfection units. The small 16 mm diameter of the lamp allows for a small system design and design flexibility. TUV T5 lamps offer almost constant UV output over their complete lifetime, for maximum security of disinfection and high system efficacy.
Main applications Deactivation of bacteria, viruses and other micro-organisms Industrial water disinfection equipment, e.g. for food & beverage industry Small municipal water treatment systems Swimming pool units Residential drinking water units (6, 11 and 16W lamps) Air treatment systems (High Output lamp versions)
Features Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection Small diameter Protective inside coating ensures almost constant UV output over the complete lifetime of the lamp Special lamp glass filters out the 185 nm ozone-forming radiation High temperature and UV-resistant lamp bases High output versions available for optimum UVC output per lamp length, allowing for further reduction of system size Warning sign on lamp indicates that the lamp radiates UVC
Benefits Effective disinfection over the useful lifetime of the lamp High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection Good environmental choice because of lowest amount of mercury
24
Technical data
Type Cap-Base Dim. Technical Lamp UVC Lamp Useful DeprePacka- Packaging Ordering no Lamp Voltage at 100h Current life ciation at ging configu- number Wattage useful life type ration (W) (V) (W) (A) (h) (%) 12 NC 1 40 75 40 75 75 75 140 97 97 97 178 178 178 175 14.0 23.0 14.0 29.0 29.0 29.0 45.0 0.425 0.800 0.425 0.425 0.425 0.425 0.800 9000 9000 9000 9000 9000 9000 9000 15 15 15 15 15 15 15 UNP UNP UNP UNP UNP UNP UNP 32 32 32 32 32 32 32 927970004099 927972104099 927970204099 927970904099 927970704099 927970804099 927971104099 TUV 36T5 HE SP TUV 36T5 HO 4P SE TUV 36T5 HE 4P SE TUV 64T5 HE 2P SE TUV 64T5 HE 4P SE (Rapid Start) TUV 64T5 HE 4P SE (Instant Start) TUV 64T5 HO 4P SE Single Pin
4 Pins Single Ended 2 4 Pins Single Ended 2 2 Pins Single Ended 3 4 Pins Single Ended 4 4 Pins Single Ended 4 4 Pins Single Ended 4
A C
A C
2 Pins / 4 Pins Single Ended D max. 19 Dim. no. 2 3 4 A max. 845.4 C max. 853.1 D max. 19
C max. 863.9
Dimensions (mm)
25
infections, like the flu, moulds, pneumonia and MRSA, is transmitted via the air - at a huge price, both in terms of human life and financial costs. Tuberculosis is even 100% transmitted via the air. Philips UV purification lamp systems provide a safe, reliable and sustainable solution. Ideal for use in ventilation air ducts, air disinfection units or stand-alone air purifiers, they help protect against airborne pathogens, creating a safer and healthier indoor environment with the power of light.
New!
Features Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes Protective inside coating ensures almost constant UV output over the complete lifetime of the lamp Special lamp glass filters out the 185 nm ozone-forming radiation Hight Output versions contain wind-chill correction for improved performance in moving air and reducing amount of required lamps Warning sign on lamp indicates that the lamp radiates UVC
Benefits Effective disinfection over the useful lifetime of the lamp High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection Good environmental choice because of lowest amount of mercury
28
Technical data
Type CapBase Dim. Technical Lamp UVC Lamp no Lamp Voltage at 100h Current Wattage (W) (V) (W) (A) 18 24 36 55 35 65 90 60 87 106 105 42 82 115 5.5 7.0 12.0 17.0 11.0 19.0 27.0 0.370 0.350 0.440 0.540 0.850 0.800 0.800 Useful life (h) 9000 9000 9000 9000 9000 9000 9000 Depreciation Packa- Packaging Ordering at useful life ging configu- number (%) type ration 12 NC 15 15 15 15 15 15 15 1CT UNP 1CT 1CT 1CT 1CT 1CT 25 50 25 25 25 25 25 927903004007 927903204016 927903404007 927908704007 927904204007 927909004007 927909804007 18W/4P 24W/4P 36W/4P 55W/4P 35W/4P HO 60W/4P HO 95W/4P HO 2G11 1 2G11 2 2G11 3 2G11 4 2G11 5 2G11 3 2G11 4
D1
A B
2G11 Dim.* A no. 1 2 3 4 5 max. 195 290 385 505 195 B max. 220 315 410 530 220
*
D1 max. 18 18 18 18 18
Dimensions (mm)
29
New!
Features Lamp type data (wattage, current, manufacturing code etc) and operational data (number of switches, burning hours, etc.) are stored on the RFID chip Information on the RFID chip will be read and checked by the driver before starting the lamp Warning levels for burning hours and/or number of switches can be programmed in the chip and compared to actual reached data System will check proper functioning of the lamp and driver The system can operate 4 lamp types, both standard and high output version. The system will recognize the lamp type used and adapt itself to the right settings In case of over-heating, the system will automatically be switched off In case of lamp or driver failure the system will be switched off and a failure code will be stored on the RFID chip
Benefits Customer info can be stored on the RFID chip and read by driver before starting the lamp Only correct lamps will be switched on Warnings can be sent to the building management system for preventive maintenance based on actual burning hours and switches Manual check-ups can be minimized as building engineers are automatically notified when the lamps need replacement failure and information can be checked via the bus Thanks to software on the controller, both individual systems and groups of systems can be addressed and switched on or off at the same time
30
Technical data
System Lamp ordering number Driver ordering number 9137... Horizontal Vertical Vertical version version (V1) version (V2) Cap- Lifetime UVC Depreciation Packaging Packaging Base at 100 at useful type configuhrs lifetime (%) ration 2G11 9000 2G11 9000 2G11 9000 2G11 9000 12.0 17.0 19.0 27.0 15% 15% 15% 15% 1CT 1CT 1CT 1CT 25 25 25 25 TUV PL-L Intelligent 36W TUV PL-L Intelligent 55W TUV PL-L Intelligent 60W TUV PL-L Intelligent 95W 9279 335 04007 132 29795 132 29495 132 29395 9279 338 04007 132 29795 132 29495 132 29395 9279 341 04007 132 29795 132 29495 132 29395 9279 344 04007 132 29795 132 29495 132 29395
120 V System System wattage Current (W) (A) TUV PL-L Intelligent 36W TUV PL-L Intelligent 55W TUV PL-L Intelligent 60W TUV PL-L Intelligent 95W 43.8 61.5 76.8 97.1 0.37 0.52 0.64 0.81
230 V System System wattage Current (W) (A) 42.7 61.4 73.9 94.9 0.20 0.27 0.33 0.42
277 V System System wattage Current (W) (A) 42.7 62.3 74.9 95.2 0.17 0.24 0.28 0.35
C B B
C B
A B
Dimensions
A max. B max. C max. D max. (mm) (mm) (mm) (mm) 52 52 52 117 102 102 271 271 271 80 78
TUV PL-L Intelligent driver horizontal version (H) 51 TUV PL-L Intelligent driver vertical version (V1) TUV PL-L Intelligent driver vertical version (V2)
31
Philips TUV T8
TUV T8 lamps are double-ended UVC (germicidal) lamps used in professional air disinfection units. TUV T8 lamps offer almost constant UV output over their complete lifetime, for maximum security of disinfection and high system efficacy. Moreover, they have a long and reliable lifetime, which allows maintenance to be planned for in advance.
Main applications Air disinfection systems in professional applications such as universities, hospitals, jails and laboratories Upper air and whole room disinfection equipment in hospitals, intensive care units and surgery rooms Areas with low maintenance and/or disruptive costs Fish ponds and process water units
Features Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes Protective inside coating ensures constant UV output over the complete lifetime of the lamp
Benefits Effective disinfection over the useful lifetime of the lamp Maintenance can be planned in advance, virtually eliminating the need for expensive spot replacement of prematurely failed lamps High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection Good environmental choice because of lowest amount of mercury
Long lifetime of 18,000 hours* High reliability with the lowest percentage of lamps that fail prematurely in the market (90% of all lamps still operate on full output and quality after 15,000 hours*) Special lamp glass filters out the 185 nm ozone-forming radiation High Output versions available for optimum UVC output per lamp length, allowing for reduction of system size Warning sign on lamp indicates that the lamp radiates UVC
*
32
Technical data
Cap-Base Dim.no Technical Lamp lamp voltage wattage (W) 10W 15W T8 F17 25W 30W 36W 55W HO 75W HO G13 G13 G13 G13 G13 G13 G13 G13 1 2 3 2 4 5 4 5 9.0 15.9 16.7 25.5 30.0 36.0 54.0 75.0 (V) 44.5 54.0 72.0 48.0 102.0 103.0 86.0 110.0 UVC (W)at 100h on EM gear (W) 2.5 4.9 4.5 7 12 15 17.5 25.5 UVC (W)at 100h on HF gear (W) 5.1 7.5 13.1 14.7 20.0 28.1 Lamp Current (A) 0.230 0.335 0.265 0.600 0.370 0.440 0.770 0.840 Useful life Useful life Depre- Packaging on EM on HF ciation type gear gear at useful (h) (h) life (%) 9000 9000 9000 9000 9000 9000 9000 9000 18000 18000 18000 18000 18000 18000 15 10 15 15 10 10 10 10 SLV SLV SLV SLV SLV SLV SLV SLV Packa- Ordering ging number configuration 12 NC 25 25 25 25 25 6 6 6 928024204005 928039004005 927941904020 928039404005 928039504005 928048604003 928049504003 928049404003
A B C
G13 Dim 1 2 3 4 5 A 331.5 437.4 589.8 894.6 1199.4 B 338.6 444.5 596.9 901.7 1206.5
*
D 28 28 28 28 28
Dimensions (mm)
33
34
HF-P 158 TL-D III 220-240V 50/60 Hz HF-P 154/155 TL5 HO/PLL III 220-240V IDC HF-P 136 TL-D III 220-240V 50/60 Hz HF-P 236 TL-D III 220-240V 50/60 Hz HF-P 1 60-120 PL-H 220-240V 50/60Hz* HF-P 180 TL5 III 220-240V 50/60 Hz
913700180066 913713034266
LC25TP w/starter
HF-P 154/155 TL5 HO/PLL III 220-240V IDC HF-P 254/255 TL5 HO/PLL III 220-240V IDC HF-P 1 60-120 PL-H 220-240V 50/60Hz HF-P 95-120 TL5 EII 220-240V
913700180066 913700622866
913700180066 913700180066
HF-P 1 60-120 PL-H 220-240V 50/60Hz HF-P 1 60-120 PL-H 220-240V 50/60Hz
This driver is not to be used for new system design. We recommend to use the Philips Advance 60 Hz as alternative.
35
2012 Koninklijke Philips Electronics N.V. All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. Date of release: April 2012 / 3222 635 66981 Printed in The Netherlands