3
CO - Crown
Energy Recovery Unit
CI/SfB
(57)

November 2011
Compact & Self-regulated
High Efficiency Plate Exchanger up to 95%
Plug & Play Controls
Indoor or Outdoor Installation
Side-by-side or Double Deck Formats
Up to 1.33 m
3
/s (4800 m
3
/h)
Full BMS Communication
EC Motors
E
r
P
C
o
m
p
lia
n
t
1
2
Application
High efficiency, high performance self regulating ventilation and energy recovery for office and industrial applications.
Thermal efficiency greater than 90 % (EN308), in compliance with ErP 2009/125/EC directive
Air filtration and temperature control included
Compact, plug n play units complete with communications in accordance with (EN 15232)
Range
Available in 6 models, the e
3
co Crown range covers flow rates from 200 to 4,800 m
3
/h (0.05 to 1.33m
3
/s).
Every e
3
co Crown model has two programmable airflow rates
e
3
co Crown range is available in 3 variants:
e
3
ssential : self regulating air handling unit dedicated to use in temperate climate area
e
3
nhanced : self regulating air handling unit fitted with an electric or a hot water coil for external temperatures down to -10C
e
3
lite : same as the e
3
nhanced series but includes an electric pre-heater for external temperatures down to -20C
Construction
Aluminium penta-post framework incorporates anti thermal bridging feature (polyamide sections) which offers class TB2
thermal performance in accordance with EN1886
Corners are manufactured from reinforced polyamide
Double skin panels have steel innner and outer skins that are 1mm in thickness (class 2 in accordance with EN 1886)
- Insulation: high density 50 mm MO wool mineral (class T2 and class A for air leakage in accordance with EN1886)
- External face : Pre-painted sheet (RAL 7035)
- Internal face: galvanized steel
Circular spigot connections with lip seals to guarantee that systems are airtight
Brackets are clamped to unit framework for fixing to the ground or ceiling
Integrated controls compartment is included to house electrical components and regulation system.
Lockable, removable, hinged access panels include integrated IP65 control panel with LCD display and pad lockable local
electrical isolator
Access to internal components via lockable panels.
Integral condensate tray and condensate pipework and connection
100% internal bypass, damper, motorized and self-regulating
Fans and Motors
Complete with high efficiency centrifugal plug fans
Direct driven via EC (Electronically Cumulated) motors with high-performance, thermal protection and built in speed control.
The EC technology is an ecological solution guaranteeing low energy consumption and better management and control of
the operating point (air flows can be controlled from 10 to 100 %). Low sound levels
Controls
User friendly interface
Fast and easy commissioning
Pre-configured controls. Constant Air Volume, Variable Air Volume and Constant Pressure options.
Plug and play solution
Full BMS capability as standard, using a MODBUS protocol. Other protocol options
available on request
Heat Exchanger
Static high-performance counter-flow heat exchanger core with aluminium plates (EUROVENT certified)
Efficiency greater than 90 % (EN 308) under operating conditions as stated below:
Fresh air : -10C/90 % RH Return air 20C/50 % RH
Automatic defrost function by opening the bypass damper and modulation of the fresh air flow if necessary - e
3
ssential and
e
3
nhanced series. The e
3
lite series, includes an extra integrated electric pre-heater (frost heater)
Filters
Filters are included to provide protection to other components (ie, exchanger/fans)
Media frames are mounted on runners fitted with lip seals to ensure effective air tightness
The e
3
co Crown unit is equipped with a high efficiency F7 grade filter fitted to the fresh air intake and a G4 grade filter to
the extracted air intake. The F7 grade filter has vee form media to deliver a high surface area and low pressure drop
Benefits and Features
Integrated ventilation control is provided by an IP65 rated display panel, suitable for either outdoor or indoor installation,
BMS communication using MODBUS is via an RS485 port. TCP/IP communication is available on request
100 % bypass, internal to the central unit, fitted with servomotors controlled automatically by built-in controls which
provides FREE-COOLING and NIGHT-COOLING functions
Wide choice of flow modulations to optimise energy consumption (EN 15232)
Temperature probes (x4) are included to monitor supply air, exhaust air and external temperature There is also a probe
to control the defrost function. An additional probe is fitted to the e
3
lite BE version for control of the pre-heater.
An integrated de-icing sensor is included to protect the hot water coil fitted into the e
3
nhanced/e
3
lite BC versions.
e
3
nhanced/e
3
lite BE versions are complete with a manual reset safety thermostat to protect the electric heater
elements
Programmable on board time clocks are included
Weekly clock and public holiday clock functions
Supply air filter pressure switch provides a dirty filter alarm
Pressure switches are used within the control of airflows of each fan, and provide fan ail alarms
Lockable local electrical isolator mounted on unit casing
Installation
Double Deck or Side-by-Side options (except e
3
co Crown 90-6)
Indoor or outdoor (with weather roof and rain canopy accessories fitted)
Low profile - suitable for mounting in ceiling voids
Specification Specification
ENERGY
EXPERTISE
ENVIRONMENT
3
4
With any system it is always important to have the right product and application to maximise efficiency, with
Flkt Woods new e
3
co Crown ERU units we have a variety of applications which benefit from our new range.
The applications below give an indication of where the new e
3
co Crown ERU units can be installed and used to
minimise energy consumption and provide precise air volume control.
Environmental Assessment Schemes
It is now very common for new build projects to try and achieve environmental standards such as those set
out in LEED and BREEAM programs. Flkt Woods, with its market leading knowledge and products in energy
recovery, has helped many projects achieve the very highest levels in both of these schemes.
Energy using Products Directive (EuP)
The various lots within the EuP directive dictates the eco design requirements for minimum efficiency grades and
labelling. Efficiency grades for fans from 125W to 500W are already published, and e
3
co Crown products are
expected to be included in the near future. The efficiency requirement is the combination of the fan and drive
efficiency, so EC technology will offer the end user or the designer a solution that is better than the minimum
eco design standards.
Energy Performance of Buildings Directive (EPBD)
The Commission of the European Union has recently proposed a revision of the EPBD (Energy Performance
in Buildings Directive, 2002/91/EC). The objective is to further strengthen the effectiveness and impact of the
existing Directive.
The background to this initiative is to optimise energy usage. It was noted that even in member states where the
existing Directive has been successfully implemented, the Commission still identified an untapped potential for
improvements that could further reduce the energy consumption and CO
2
emissions from buildings.
Building Regulations - Part L2 for New (A) and Existing Buildings (B)
Effective from October 2010, Building Regulations Part L and F outline the need for a healthier working/indoor
environment, with the target to decrease CO
2
emissions by a further 25% from the initial reduction stated
within the 2006 document. The eco design of our e3co Crown range will allow specifiers to create designs
which incorporate the necessary energy usage reductions, whilst still providing precise control of mechanical
ventilation.
European Energy Related Products Directive (ErP)
Not only does the e
3
co-Crown meet the requirements of the ErP 2009/125/EC, but also EN15232. In addition,
at the heart of the product, its heat exchanger core is Eurovent Certificated.
LEGISLATION
In Europe, all countries now have to design their new buildings to meet energy targets that
are set out in the Energy Performance in Buildings Directive (EPBD). All Flkt Woods Energy
Performance of Buildings Directive solutions are designed to enable full compliance with this
and other directives regarding ventilation and air conditioning.
Being a global manufacturer and supplier makes meeting legislation easier for Flkt Woods. It means that
Flkt Woods must produce solutions at standards that equal the most stringent legislation and guidelines around.
Only by doing this can we ensure that we meet relevant standards within every market.
Applications Legislation
OFFICES
Flkt Woods offer a high
performance product range
covering all key elements of
the overall ventilation system.
Our products are designed
to secure the best overall
performance of the system as a
whole, considering parameters
such as health and air quality,
energy efficiency, noise, fire
safety and ease of installation.
EDUCATION
High occupancy levels
during teaching periods
require energy-efficient and
controllable demand-based
management of air quality and
temperature. The comfort,
health and alertness of
staff and pupils is ensured
during the learning process,
but operating costs can be
minimised when these facilities
are unoccupied.
GYMNASIUM/
INDOOR SPORTS
Differing types of activity
and occupancy mean a
broad spectrum of functional
requirements to ensure efficient
removal of used air and the
introduction of fresh supplies.
Systems need to contain and
control the periodic build up
of high humidity levels and
temperature.
HEALTHCARE
For a hospital to operate at
its maximum potential, it has to
have all systems working
at the optimum. This not
only applies to staff,
communications and life
support systems, but also
to pipework, cleaning and
ventilation systems.
RETAIL/
SHOPPING AREAS
With high activity levels
during the working week and
weekends, its important to
make sure that all areas of
ventilation are maintained and
Flkt Woods has the systems
to achieve all requirements.
RESIDENTIAL
The purpose of ventilation is to
provide clean good quality air
by removing the stale, polluted
air from our homes. The main
task is of course to ensure that
the indoor air is healthy and
safe to breathe. Ventilation
today is also about energy and
saving energy costs by adding
heat recovery to the ventilation
system.
TOILETS
Fast, efficient removal of
odours and air-borne pollutants
contribute to the maintenance
of cleanliness and an
acceptable environment in
communal sanitary areas.
INDUSTRY
Flkt Woods technology
is used widely in industrial
processing plants and factories
for ventilation of work spaces,
as vital components in high
tech manufacturing facilities,
and for maintaining delicate
environments within high
tolerance levels in
petro-chemical and
pharmaceutical plants.
5
6
Fresh air
Configurations and Electrical Information
Configuration W Configuration Y
Configuration L
Except e
3
co Crown 90-6
Configuration P
Except e
3
co Crown 90-6
Side-by-side format (airflows side-by-side) (view from above)
Double Decked format (airflows one above the other) (side access view)
Electrovalve
Kit Type
Water Coil Options
HOT WATER COIL: Included in
e
3
nhanced/e
3
lite BC
HOT WATER C
DN/Kvs - 90/ 70 80/60 60/50 45/50
10/1,6 - 3/8 M - IP54
90-1 90-1 90-1 90-1
90-2 90-2 90-2 90-2
90-3 90-3 90-3 90-3
15/2.5 - 1/2 M - IP54 90-4 90-4 90-4 90-4
20/4 - 1/2 F - IP54 90-5 90-5 90-5 90-5
25/6.3 - 3/4 F - IP54 - - - -
25/10 - 1 F - IP54 90-6 90-6 90-6 90-6
32/16 - 1 1/4 F - IP41 - - - -
Electro valve kit consists 1 off 3-way
valve, 3 connectors, servomotor
suitable for control via a 0-10v
signal.
Servomotors fitted to valves are
available with either an IP41
enclosure (indoor installation) or
IP54 rated, suitable for outdoor
installation.
Crown
Model
Fan
Motor
power
(W)
Temp
Range
C/C
(min/
max)
IP.
Rating
Overheat
Protection*
e
3
ssential
e
3
nhanced BC
e
3
lite BC e
3
nhanced BE e
3-
lite BE
Voltage
V
FLC
Amp
Rating
**
Voltage
V
FLC
Amp
Rating
**
Voltage
V
Model
FLC
Amp
Rating
**
Voltage
V
Model
FLC
Amp
Rating
**
90-1 2 x 220 -20 / 60 IP44 PTI 230/1/50 3.4 230/1/50 14.3 230/1/50 BE 025 14.3 230/1/50 BE 025 25.2
90-2 2 x 485 -20 / 60 IP54 PTO 230/1/50 6.2 230/1/50 22.5 230/1/50 BE 025 17.1 230/1/50 BE 025 33.4
90-3 2 x 900 -20 / 40 IP54 PTO 230/1/50 7.8 400/3/50 15.4
230/1/50 BE 037 24.1
400/3/50 BE 052 23.0
400/3/50 BE 052 15.4
90-4 2 x 900 -20 / 40 IP54 PTO 230/1/50 7.8 400/3/50 17.5
230/1/50 BE 037 24.1
400/3/50 BE 067 27.2
400/3/50 BE 067 17.5
90-5 2 x 2500 -20 / 40 IP54 PTO 400/3N/50 8.0 400/3/50 19.9 400/3/50
BE 067 17.7
400/3/50
BE 067 29.6
BE 135 27.5 BE 135 39.4
90-6 2 x 2500 -20 / 40 IP54 PTO 400/3N/50 8.0 400/3/50 34.0 400/3/50
BE 067 17.7
400/3/50
BE 067 43.7
BE 135 27.5 BE 135 53.5
* PTO: Overheat protection opening (output on terminal block) / PTI: built-in overheat protection (in series with the windings).
** SC is the same as the FLC as EC motors use a soft start function.
Extract air
Fresh air Extract air
Drawing and Dimensions
* Available in double deck configuration only.
Double Deck format - 90-1 To 90-6
Ce cccumenI e:I |c prcpriI ce C/L/D/lF. l| ne peuI Ire reprccuiI u'cvec ncIre ccccrc criI
20

D
E
D

C
20
I
J
8
130 110 G K
D
8
D E
F F2
A
C
F1
Ce cccumenI e:I |c prcpriI ce C/L/D/lF. l| ne peuI Ire reprccuiI u'cvec ncIre ccccrc criI
20

D
E
D

C
20
I
J
8
130 110 G K
D
8
D E
F F2
A
C
F1
Ce cccumenI e:I |c prcpriI ce C/L/D/lF. l| ne peuI Ire reprccuiI u'cvec ncIre ccccrc criI
20

D
E
D

C
20
I
J
8
130 110 G K
D
8
D E
F F2
A
C
F1
Model A B C D E F F1 F2 G J K T
e
3
ssential
kg
e
3
nhanced
kg
e
3
lite
kg
90-1 315 1915 915 505 255 405 1097 362 456 465 245 540
1
/
2
215 218 220
90-2 315 1915 915 505 255 405 1097 362 456 465 245 540
1
/
2
215 218 220
90-3 400 2230 1115 605 305 505 1261 362 607 565 345 690
1
/
2
310 315 318
90-4 450 2345 1315 705 355 605 1376 362 607 565 445 690
3
/
4
400 407 412
90-5 500 2625 1515 805 405 705 1520 450 655 640 545 740
3
/
4
550 560 564
90-6* 630 2970 1715 1030 455 805 1677 535 758 685 645 840 1 710 725 732
Dimensions Table
Model
RC Weight
kg
K
mm
H
mm
J
mm
MD Weight
kg
90-1 4 340 362 362 8
90-2 4 340 362 362 8
90-3 5 440 462 462 10
90-4 7 540 562 562 13
90-5 10 640 662 662 15
90-6* 13 740 762 762 17
90-7 9 540 562 1162 14
Optional Extras
Ce cccumenI e:I |c prcpriI ce C/L/D/lF. l| ne peuI Ire reprccuiI u'cvec ncIre ccccrc criI
20

D
E
D

C
20
I
J
8
130 110 G K
D
8
D E
F F2
A
C
F1
Option RC Option MD
RC - Rain
Canopy

MD - Motorised
Damper
Integrated Exchanger
Side-by-Side format - 90-1 To 90-5
Integrated Exchanger
7
8
R
e
t
u
r
n
a
ir
2
0

C
/ 5
0
%
-5C / 90% HR
-10C / 90% HR
300Pa
250Pa
200Pa
150Pa
300Pa
250Pa 200Pa 150Pa
0C / 90% HR
+5C / 90% HR
E
f
f
ic
ie
n
c
y
(
%
)
-
E
N
3
0
8
p
e
r
f
a
n
P
o
w
e
r
c
o
n
s
u
m
p
t
io
n
(
W
)
S
t
a
t
ic
p
r
e
s
s
u
r
e
(
P
a
)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
100% 90%
80% 70% 60% 50% 40%
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
Flow rate (m
3
/s)
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
Flow rate (m
3
/s)
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
Flow rate (m
3
/s)
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
Flow rate (m
3
/s)
Performance curves shown are based on the e
3
nhanced or e
3
lite product versions, with an Electric Post Heater fitted (i.e. BE variant).
Performance (in terms of pressure) for the e
3
ssential variant (with no heaters fitted) is approximately 25 Pa higher, while performance
(in terms of pressure) for the e
3
nhanced or e
3
lite versions, with a Hot Water Post heater fitted (i.e. BC variant) is 45 Pa lower than the BE variant.
Aerodynamic performance has been obtained from tests based upon EN 13053 and conform to ISO 5801.
Max Fan Pressure is optimum for HVAC applications. Data for higher pressures is available on request.
NSC4 = Sound level at 4 m,
in free field, intakes and
outlets connected up
Performance - 90-1 Heating Data - 90-1
BC for e
3
nhanced and e
3
lite versions - Hot Water Coil
Water
temp
(C/C)
Coil
air on
Temp
(C)
Flow rate (m/h)
(m/s)
300
(0.08)
400
(0.11)
500
(0.14)
600
(0.17)
700
(0.19)
800
(0.22)
82/71
11
Power (kW)/Air supply temp. (C) 5.1/60 6.3/56 7.3/53 8.3/51 9.2/49 10/47
Water flow rate (l/h)/DP water (kPa) 410/11 510/17 590/22 670/28 740/34 800/41
15
Power (kW)/Air supply temp. (C) 4.8/61 5.8/58 6.8/55 7.7/52 8.5/51 9.33/49
Water flow rate (l/h)/DP water (kPa) 380/10 470/14 550/20 620/24 690/31 750/35
90/70
11
Power (kW)/Air supply temp. (C) 5.3/62 6.5/58 7.5/55 8.5/52 9.4/50 10.2/48
Water flow rate (l/h)/DP water (kPa) 240/4 290/6 340/8 380/10 420/12 450 /12
15
Power (kW)/Air supply temp. (C) 4.9/63.9 6.1/59 7.05/56 7.9/54 8.7/52 9.5/50.4
Water flow rate (l/h)/DP water (kPa) 220/3 270/5 310/6 350/8 390 /10 420 /11
45/40
11
Power (kW)/Air supply temp. (C) 2.4/34 3/32.7 3.5/31 3.9/30.1 4.3/29 4.7/28
Water flow rate (l/h)/DP water (kPa) 430/13 520/19 610/24 680/30 760/37 820/43
15
Power (kW)/Air supply temp. (C) 2.1/35.6 2.5/34 3/32 3.3/31.8 3.7/30.9 4/30.1
Water flow rate (l/h)/DP water (kPa) 370/10 450/14 520/18 590/23 650/27 710/32
60/50
11
Power (kW)/Air supply temp. (C) 3.4/43.7 4.2/41 4.8/39 5.4/37.5 6/36 6.5/34.9
Water flow rate (l/h)/DP water (kPa) 300/6 360/9 420/12 480/15 530/18 570 /20
15
Power (kW)/Air supply temp. (C) 3/44 3.7/42 4.3/40 4.9/39.3 5.4/37 5.8/36.8
Water flow rate (l/h)/DP water (kPa) 270/5 330/8 380/10 430/12 470/14 510/17
BE for e
3
nhanced and e
3
lite versions - Electric Heater
Notes:
1) Coil air on temperatures are based on 2 scenarios, where the external air temperature onto the plate heat exchanger is either -5C/90% RH
or 0C/90% RH, which typically result in plate heat exchange air off temperatures of 11C or 15C respectively, which we have then stated as
water coil air on temperatures.
2) Rated kW Powers and coil air off temperatures stated above are max valves, so should not be used to calculate heating loads.
Fresh Air 0C 0C -5C -10C -15C -20C
Qv (m/h) 800 800 800 800 800 800
Version
e
3
ssential e
3
nhanced BE 025 e
3
lite BE 025
Electric Heater Pre-heater + Post Heater
Total power (kW) - 2.5 2.5 2.5 2.5 + 2.5 2.5 + 2.5
Air supply Temp. (C) 16.8 26.2 25.6 20.8 24.6 19.7
Typical Plate Heat Exchanger Core Performance data
Thermal performance data for the Counter-flow Plate Heat Exchanger core is based
on a nominal Airflow per unit (approx. 80% of maximum) and the following air conditions:
External air temperature: -5C @ 90% RH and Return air temperature: 22C @ 50% RH
Model
Airfow rate
Recovered
kW
Air Off temp C / RH
Thermal
Efficiency % m3/h m
3
/s
Crown 90-1 450 0.13 3.7 19.3C 16.1%RH 90.1
Cooling coils available, please enquire for further details.
9
10
Performance - 90-2 Heating Data - 90-2
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
-5C / 90% HR
+5C / 90% HR
0C / 90% HR
-10C / 90% HR
300Pa
250Pa
150Pa
300Pa
250Pa
200Pa 150Pa
200Pa
150Pa
R
e
t
u
r
n
a
ir
2
0

C
/ 5
0
%
E
f
f
ic
ie
n
c
y
(
%
)
-
E
N
3
0
8
p
e
r
f
a
n
P
o
w
e
r
c
o
n
s
u
m
p
t
io
n
(
W
)
S
t
a
t
ic
p
r
e
s
s
u
r
e
(
P
a
)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/s)
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
Flow rate (m
3
/s)
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
Flow rate (m
3
/s)
0.06 0.08 0.11 0.14 0.17 0.19 0.22 0.25 0.28
Flow rate (m
3
/s)
80%
70%
60%
50%
40%
Performance curves shown are based on the e
3
nhanced or e
3
lite product versions, with an Electric Post Heater fitted (i.e. BE variant).
Performance (in terms of pressure) for the e
3
ssential variant (with no heaters fitted) is approximately 25 Pa higher, while performance
(in terms of pressure) for the e
3
nhanced or e
3
lite versions, with a Hot Water Post heater fitted (i.e. BC variant) is 45 Pa lower than the BE variant.
Aerodynamic performance has been obtained from tests based upon EN 13053 and conform to ISO 5801.
Max Fan Pressure is optimum for HVAC applications. Data for higher pressures is available on request.
BC for e
3
nhanced and e
3
lite versions - Hot Water Coil
Water
temp
(C/C)
Coil
air on
Temp
(C)
Flow rate (m/h)
(m/s)
400
(0.11)
500
(0.14)
600
(0.17)
700
(0.19)
800
(0.22
900
(0.25)
82/71
11
Power (kW)/Air supply temp. (C) 6.3/56 7.3/53 8.3/51 9.2/49 10/47 10.8/45
Water fow rate (l/h)/DP water (kPa) 510/17 590/22 670/28 740/34 800/41 870/47
15
Power (kW)/Air supply temp. (C) 5.8/58 6.8/55 7.7/52 8.5/51 9.33/49 10.1/47.8
Water fow rate (l/h)/DP water (kPa) 470/14 550/20 620/24 690/31 750/35 810/41
90/70
11
Power (kW)/Air supply temp. (C) 6.5/58 7.5/55 8.5/52 9.4/50 10.2/48 11/46.8
Water fow rate (l/h)/DP water (kPa) 290/6 340/8 380/10 420/12 450 /12 490/15
15
Power (kW)/Air supply temp. (C) 6.1/59 7.05/56 7.9/54 8.7/52 9.5/50.4 10.3/48.8
Water fow rate (l/h)/DP water (kPa) 270/5 310/6 350/8 390 /10 420 /11 450/13
45/40
11
Power (kW)/Air supply temp. (C) 3/32.7 3.5/31 3.9/30.1 4.3/29 4.7/28 5.1/27.5
Water fow rate (l/h)/DP water (kPa) 520/19 610/24 680/30 760/37 820/43 890/51
15
Power (kW)/Air supply temp. (C) 2.5/34 3/32 3.3/31.8 3.7/30.9 4/30.1 4.4/29.5
Water fow rate (l/h)/DP water (kPa) 450/14 520/18 590/23 650/27 710/32 760/38
60/50
11
Power (kW)/Air supply temp. (C) 4.2/41 4.8/39 5.4/37.5 6/36 6.5/34.9 7/33
Water fow rate (l/h)/DP water (kPa) 360/9 420/12 480/15 530/18 570 /20 620/24
15
Power (kW)/Air supply temp. (C) 3.7/42 4.3/40 4.9/39.3 5.4/37 5.8/36.8 6.4/35.9
Water fow rate (l/h)/DP water (kPa) 330/8 380/10 430/12 470/14 510/17 550/20
BE for e
3
nhanced and e
3
lite versions - Electric Heater
Fresh Air 0C 0C -5C -10C -15C -20C
Qv (m/h) 980 980 980 980 980 980
Version
e
3
ssential e
3
nhanced BE 025 e
3
lite BE 025
Electric Heater Pre-heater + Post Heater
Total power (kW) - 2.5 2.5 2.5 3.75 + 2.5 3.75 + 2.5
Air supply Temp. (C) 16.7 24.4 23.8 19 24.6 19.7
Notes:
1) Coil air on temperatures are based on 2 scenarios, where the external air temperature onto the plate heat exchanger is either -5C/90% RH
or 0C/90% RH, which typically result in plate heat exchange air off temperatures of 11C or 15C respectively, which we have then stated as
water coil air on temperatures.
2) Rated kW Powers and coil air off temperatures stated above are max valves, so should not be used to calculate heating loads.
Typical Plate Heat Exchanger Core Performance data
Thermal performance data for the Counter-flow Plate Heat Exchanger core is based
on a nominal Airflow per unit (approx. 80% of maximum) and the following air conditions:
External air temperature: -5C @ 90% RH and Return air temperature: 22C @ 50% RH
Model
Airfow rate
Recovered
kW
Air Off temp C / RH
Thermal
Efficiency % m
3
/h m
3
/s
Crown 90-2 600 0.17 4.8 19.0C 16.4%RH 89.0
NSC4 = Sound level at 4 m,
in free field, intakes and
outlets connected up
Cooling coils available, please enquire for further details.
11
12
Performance - 90-3 Heating Data - 90-3
BC for e
3
nhanced and e
3
lite versions - Hot Water Coil
Water
temp
(C/C)
Coil
air on
Temp
(C)
Flow rate (m/h)
(m/s)
600
(0.17)
800
(0.22)
1000
(0.28)
1200
(0.33)
1400
(0.39)
1500
(0.42)
82/71
11
Power (kW)/Air supply temp. (C) 10.1/59.7 12.4/55.8 14.4/52 16/50 18/48 18.8/47.3
Water fow rate (l/h)/DP water (kPa) 810/18 990/27 1150/36 1310/46 1440/55 1510/60
15
Power (kW)/Air supply temp. (C) 9.4/61 11.5/57.4 13.4/54.5 15.2/52.2 16.7/50 17.5/49.3
Water fow rate (l/h)/DP water (kPa) 750/16 920/24 1070/31 1220/40 1340/48 1400/52
90/70
11
Power (kW)/Air supply temp. (C) 10.5/62.1 13/57.8 14.9/54.4 16.7/51.7 18.5/49.5 19.3/48.6
Water fow rate (l/h)/DP water (kPa) 460/6 570/9 660/12 740/15 820/18 850/20
15
Power (kW)/Air supply temp. (C) 9.8/63.4 12/59 13.9/56.2 15.6/53.7 17.2/51.5 18/50.7
Water fow rate (l/h)/DP water (kPa) 430/6 530/8 610/10 690/13 760/16 800/18
45/40
11
Power (kW)/Air supply temp. (C) 4.8/34.2 5.8/32.4 6.8/30.9 7.7/29.7 8.5/28.7 8.91/28.3
Water fow rate (l/h)/DP water (kPa) 830/20 1020/30 1190/40 1340/49.1 1480/60 1550/68
15
Power (kW)/Air supply temp. (C) 4.1/35.4 5/33.8 5.88/32.5 6.6/31.4 7.3/30.6 7.6/30.2
Water fow rate (l/h)/DP water (kPa) 720/15 880/22 1020/30 1160/37.3 1280/45 1330/51
60/50
11
Power (kW)/Air supply temp. (C) 6.6/43.4 8.1/40.8 9.4/38.7 10.7/37 11.8/35.6 12.3/35
Water fow rate (l/h)/DP water (kPa) 580/10 710/14 830/20 940/24 1030/30 1080/33
15
Power (kW)/Air supply temp. (C) 5.9/44.6 7.3/42.2 8.5/40.3 9.6/38.8 10.6/37.5 11.1/36.9
Water fow rate (l/h)/DP water (kPa) 520/8 640/12 750/16 840/20 930/25 970/27
BE for e
3
nhanced and e
3
lite versions - Electric Heater
Fresh Air 0C 0C -5C -10C -15C -20C
Qv (m/h) 1550 1550 1550 1550 1550 1550
Version
e
3
ssential e
3
nhanced BE 025 e
3
lite BE 025
Electric Heater Pre-Heater + Post Heater
Total power (kW) - 3.75 3.75 3.75 5.25 + 3.75 5.25 + 5.25
Air supply Temp. (C) 16.7 24 23.5 21.5 23.7 21.6
-5C / 90% HR
+5C / 90% HR
0C / 90% HR
-10C / 90% HR
300Pa
250Pa
200Pa
300Pa
250Pa
200Pa 150Pa
150Pa
300Pa
150Pa
250Pa
200Pa
150Pa
R
e
t
u
r
n
a
ir
2
0

C
/ 5
0
%
E
f
f
ic
ie
n
c
y
(
%
)
-
E
N
3
0
8
p
e
r
f
a
n
P
o
w
e
r
c
o
n
s
u
m
p
t
io
n
(
W
)
S
t
a
t
ic
p
r
e
s
s
u
r
e
(
P
a
)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
80%
70%
60%
50%
40%
0.11 0.14 0.17 0.19 0.22 0.25 0.28 0.31 0.33 0.36 0.39 0.42 0.44
Flow rate (m
3
/s)
0.11 0.14 0.17 0.19 0.22 0.25 0.28 0.31 0.33 0.36 0.39 0.42 0.44
Flow rate (m
3
/s)
0.11 0.14 0.17 0.19 0.22 0.25 0.28 0.31 0.33 0.36 0.39 0.42 0.44
Flow rate (m
3
/s)
0.11 0.14 0.17 0.19 0.22 0.25 0.28 0.31 0.33 0.36 0.39 0.42 0.44
Flow rate (m
3
/s)
Performance curves shown are based on the e
3
nhanced or e
3
lite product versions, with an Electric Post Heater fitted (i.e. BE variant).
Performance (in terms of pressure) for the e
3
ssential variant (with no heaters fitted) is approximately 25 Pa higher, while performance
(in terms of pressure) for the e
3
nhanced or e
3
lite versions, with a Hot Water Post heater fitted (i.e. BC variant) is 45 Pa lower than the BE variant.
Aerodynamic performance has been obtained from tests based upon EN 13053 and conform to ISO 5801.
Max Fan Pressure is optimum for HVAC applications. Data for higher pressures is available on request.
30%
Notes:
1) Coil air on temperatures are based on 2 scenarios, where the external air temperature onto the plate heat exchanger is either -5C/90% RH
or 0C/90% RH, which typically result in plate heat exchange air off temperatures of 11C or 15C respectively, which we have then stated as
water coil air on temperatures.
2) Rated kW Powers and coil air off temperatures stated above are max valves, so should not be used to calculate heating loads.
Typical Plate Heat Exchanger Core Performance data
Thermal performance data for the Counter-flow Plate Heat Exchanger core is based
on a nominal Airflow per unit (approx. 80% of maximum) and the following air conditions:
External air temperature: -5C @ 90% RH and Return air temperature: 22C @ 50% RH
Model
Airfow rate
Recovered
kW
Air Off temp C / RH
Thermal
Efficiency % m
3
/h m
3
/s
Crown 90-3 950 0.26 7.7 19.0C 16.4%RH 89.0
NSC4 = Sound level at 4 m,
in free field, intakes and
outlets connected up
Cooling coils available, please enquire for further details.
13
14
Performance - 90-4 Heating Data - 90-4
BC for e
3
nhanced and e
3
lite versions - Hot Water Coil
Water
temp
(C/C)
Coil
air on
Temp
(C)
Flow rate (m/h)
(m/s)
1000
(0.28)
1250
(0.35)
1500
(0.42)
1750
(0.49)
2000
(0.56)
2250
(0.63)
82/71
11
Power (kW)/Air supply temp. (C) 16/58 19.4/55 22/53 24.3/51.3 26/49.5 28/47
Water fow rate (l/h)/DP water (kPa) 1320/16 1560/22 1760/28 1950/34 2130/41 2300/47
15
Power (kW)/Air supply temp. (C) 15.4/60.3 18/57 20.5/55 22.7/53 24.7/51 26/50
Water fow rate (l/h)/DP water (kPa) 1240/14 1440/19 1640/24 1820/30 1980/35 2140/41
90/70
11
Power (kW)/Air supply temp. (C) 17.2/61.1 20.1/57.8 22.7/55.1 25.1/52.9 27.3/50.9 29.4/49.2
Water fow rate (l/h)/DP water (kPa) 760/6 890/8 1000/10 1110/12 1210/14 1300/16
15
Power (kW)/Air supply temp. (C) 16/62.5 18.7/59.5 21.2/56.9 23.4/54.7 25.5/52.9 27.5/51.3
Water fow rate (l/h)/DP water (kPa) 710/5 830/7 940/9 1030/10 1130/13 1210/14
45/40
11
Power (kW)/Air supply temp. (C) 7.83/33.8 9.2/32.4 10.4/31.2 11.5/30.2 12.6/29.4 13.6/28.6
Water fow rate (l/h)/DP water (kPa) 1360 /19 1600/26 1810/32 2000/38 2190/46 2370/54
15
Power (kW)/Air supply temp. (C) 6.75/35 7.9/33.8 8.97/32.8 10/31.9 10.8/31.1 11.7/30.4
Water fow rate (l/h)/DP water (kPa) 1180/14 1380/20 1560/24 1730/30 1880/35 2040/41
60/50
11
Power (kW)/Air supply temp. (C) 10.9/42.9 12.8/40.8 14.4/39.1 16/37.7 17.4/36.5 18.8/35.4
Water fow rate (l/h)/DP water (kPa) 950/10 1120/13 1260/16 1400/19 1520/22 1650/26
15
Power (kW)/Air supply temp. (C) 9.8/44.1 11.5/42.2 13/40.7 14.4/39.4 15.7/38.3 16.9/37.3
Water fow rate (l/h)/DP water (kPa) 860/8 1010/10 1140/13 1260 /16 1370/19 1480/22
BE for e
3
nhanced and e
3
lite versions - Electric Heater
Fresh Air 0C 0C -5C -10C -15C -20C
Qv (m/h) 2300 2300 2300 2300 2300 2300
Version
e
3
ssential e
3
nhanced BE 025 e
3
lite BE 025
Electric Heater Pre-Heater + Post-Heater
Total power (kW) - 3.75 3.75 6.75 6.75 + 3.75 6.75 + 6.75
Air supply Temp. (C) 16.6 21.5 21 20.1 20.1 19.1
-5C / 90%HR
+5C / 90% HR
0C / 90% HR
-10C / 90% HR
300Pa
250Pa 200Pa
300Pa
200Pa
250Pa
150Pa
150Pa
200Pa
200Pa 150Pa
R
e
t
u
r
n
a
ir
2
0

C
/ 5
0
%
E
f
f
ic
ie
n
c
y
(
%
)
-
E
N
3
0
8
p
e
r
f
a
n
P
o
w
e
r
c
o
n
s
u
m
p
t
io
n
(
W
)
S
t
a
t
ic
p
r
e
s
s
u
r
e
(
P
a
)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
100% 90%
80%
70%
60%
50%
40%
0.17 0.22 0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67
Flow rate (m
3
/s)
0.17 0.22 0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67
Flow rate (m
3
/s)
0.17 0.22 0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67
Flow rate (m
3
/s)
0.17 0.22 0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67
Flow rate (m
3
/s)
Performance curves shown are based on the e
3
nhanced or e
3
lite product versions, with an Electric Post Heater fitted (i.e. BE variant).
Performance (in terms of pressure) for the e
3
ssential variant (with no heaters fitted) is approximately 25 Pa higher, while performance
(in terms of pressure) for the e
3
nhanced or e
3
lite versions, with a Hot Water Post heater fitted (i.e. BC variant) is 45 Pa lower than the BE variant.
Aerodynamic performance has been obtained from tests based upon EN 13053 and conform to ISO 5801.
Max Fan Pressure is optimum for HVAC applications. Data for higher pressures is available on request.
Notes:
1) Coil air on temperatures are based on 2 scenarios, where the external air temperature onto the plate heat exchanger is either -5C/90% RH
or 0C/90% RH, which typically result in plate heat exchange air off temperatures of 11C or 15C respectively, which we have then stated as
water coil air on temperatures.
2) Rated kW Powers and coil air off temperatures stated above are max valves, so should not be used to calculate heating loads.
Typical Plate Heat Exchanger Core Performance data
Thermal performance data for the Counter-flow Plate Heat Exchanger core is based
on a nominal Airflow per unit (approx. 80% of maximum) and the following air conditions:
External air temperature: -5C @ 90% RH and Return air temperature: 22C @ 50% RH
Model
Airfow rate
Recovered
kW
Air Off temp C / RH
Thermal
Efficiency % m
3
/h m
3
/s
Crown 90-4 1450 0.40 11.9 19.5C 16 %RH 90.7
NSC4 = Sound level at 4 m,
in free field, intakes and
outlets connected up
Cooling coils available, please enquire for further details.
15
16
Performance - 90-5 Heating Data - 90-5
BC for e
3
nhanced and e
3
lite versions - Hot Water Coil
Water
temp
(C/C)
Coil
air on
Temp
(C)
Flow rate (m/h)
(m/s)
1500
(0.42)
1900
(0.53)
2300
(0.64)
2700
(0.75)
3100
(0.86)
3500
(0.97)
82/71
11
Power (kW)/Air supply temp. (C) 24.8/58 29.3/55 33.5/53.1 37.2/50.9 40.7/49 44/47.4
Water fow rate (l/h)/DP water (kPa) 1990/42 2350/58 2690/74 2980/91 3260/108 3530/125
15
Power (kW)/Air supply temp. (C) 23.1/60.3 27.4/57.3 31.2/54.8 34.7/52.8 37.9/51 41/49.4
Water fow rate (l/h)/DP water (kPa) 1850/37 2200/51 2500/65 2780/80 3040/94.7 3290/110
90/70
11
Power (kW)/Air supply temp. (C) 25.3/60.2 29.7/56.7 33.8/53.9 37.5/51.5 40.9/49.5 44.1/47.8
Water fow rate (l/h)/DP water (kPa) 1120/4 1310/6 1490/8 1660/9 1810/11 1950/13
15
Power (kW)/Air supply temp. (C) 23.5/61.6 27.7/58.3 31.5/55.6 34.9/53.4 38.1/51.5 41.1/49.9
Water fow rate (l/h)/DP water (kPa) 1040/4 1220/5 1390/7 1540/8 1680/10 1820/11
45/40
11
Power (kW)/Air supply temp. (C) 11.5/33.5 13.6/32 15.5/30.7 17.3/29.7 18.9/28.8 20.4/28
Water fow rate (l/h)/DP water (kPa) 2000/14 2370/20 2700/25 3010/10 3290/36 3550/41
15
Power (kW)/Air supply temp. (C) 10/34.7 11.7/33.4 13.4/32.3 14.9/31.3 16.3/30.6 17.6/29.9
Water fow rate (l/h)/DP water (kPa) 1730/11 2040/15 2330 /19 2600/23 2840/27 3070/32
60/50
11
Power (kW)/Air supply temp. (C) 16/42.3 18.9/40.1 21.5/38.3 23.9/36.9 26.1/35.6 28.2/34.5
Water fow rate (l/h)/DP water (kPa) 1410/7 1650/9.4 1880/12 2090/15 2280/18 2470/20
15
Power (kW)/Air supply temp. (C) 14.4/43.6 17/41.6 19.3/40 21.5/38.6 23.5/37.5 25.3/36.5
Water fow rate (l/h)/DP water (kPa) 1260/6 1490/8 1690/10 1880 /12 2060/15 2210/17
BE for e
3
nhanced and e
3
lite versions - Electric Heater
Fresh Air 0C 0C -5C -10C -15C -20C
Qv (m/h) 3500 3500 3500 3500 3500 3500
Version
e
3
ssential e
3
nhanced BE 025 e
3
lite BE 025
Electric Heater Pre-Heater + Post-Heater
Total power (kW) - 6.75 6.75 13.5 8.25 + 6.75 8.25 + 13.5
Air supply Temp. (C) 16.7 22.5 22 20.2 19.5 20.5
-5C / 90% HR
+5C / 90% HR
0C / 90% HR
300Pa
250Pa
250Pa
200Pa
200Pa
150Pa
150Pa
300Pa
-10C / 90% HR
200Pa
200Pa
150Pa
150Pa
R
e
t
u
r
n
a
ir
2
0

C
/ 5
0
%
E
f
f
ic
ie
n
c
y
(
%
)
-
E
N
3
0
8
p
e
r
f
a
n
P
o
w
e
r
c
o
n
s
u
m
p
t
io
n
(
W
)
S
t
a
t
ic
p
r
e
s
s
u
r
e
(
P
a
)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
70%
60%
50%
40%
30%
0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67 0.72 0.78 0.83 0.89 0.94 1.00
Flow rate (m
3
/s)
0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67 0.72 0.78 0.83 0.89 0.94 1.00
Flow rate (m
3
/s)
0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67 0.72 0.78 0.83 0.89 0.94 1.00
Flow rate (m
3
/s)
0.28 0.33 0.39 0.44 0.50 0.56 0.61 0.67 0.72 0.78 0.83 0.89 0.94 1.00
Flow rate (m
3
/s)
Performance curves shown are based on the e
3
nhanced or e
3
lite product versions, with an Electric Post Heater fitted (i.e. BE variant).
Performance (in terms of pressure) for the e
3
ssential variant (with no heaters fitted) is approximately 25 Pa higher, while performance
(in terms of pressure) for the e
3
nhanced or e
3
lite versions, with a Hot Water Post heater fitted (i.e. BC variant) is 45 Pa lower than the BE variant.
Aerodynamic performance has been obtained from tests based upon EN 13053 and conform to ISO 5801.
Max Fan Pressure is optimum for HVAC applications. Data for higher pressures is available on request.
Notes:
1) Coil air on temperatures are based on 2 scenarios, where the external air temperature onto the plate heat exchanger is either -5C/90% RH
or 0C/90% RH, which typically result in plate heat exchange air off temperatures of 11C or 15C respectively, which we have then stated as
water coil air on temperatures.
2) Rated kW Powers and coil air off temperatures stated above are max valves, so should not be used to calculate heating loads.
Typical Plate Heat Exchanger Core Performance data
Thermal performance data for the Counter-flow Plate Heat Exchanger core is based
on a nominal Airflow per unit (approx. 80% of maximum) and the following air conditions:
External air temperature: -5C @ 90% RH and Return air temperature: 22C @ 50% RH
Model
Airfow rate
Recovered
kW
Air Off temp C / RH
Thermal
Efficiency % m
3
/h m
3
/s
Crown 90-5 2100 0.58 17.0 19.1C 16.4%RH 89.2
NSC4 = Sound level at 4 m,
in free field, intakes and
outlets connected up
Cooling coils available, please enquire for further details.
17
18
Performance - 90-6 Heating Data - 90-6
BC for e
3
nhanced and e
3
lite versions - Hot Water Coil
Water
temp
(C/C)
Coil
air on
Temp
(C)
Flow rate (m/h)
(m/s)
2200
(0.61)
2700
(0.75)
3200
(0.89)
3700
(1.03)
4200
(1.17)
4700
(1.31)
82/71
11
Power (kW)/Air supply temp. (C) 36/59 42/56 47.8/54.2 52.7/52.3 57.3/50 61/49
Water fow rate (l/h)/DP water (kPa) 2940/8 3410/11 3830/13.3 4230/16 4600/18.7 4950/22
15
Power (kW)/Air supply temp. (C) 34/60.6 39/58 44.5/55.8 49.1/54 53.4/52.4 57.4/50.9
Water fow rate (l/h)/DP water (kPa) 2730/7 3170/9.3 3570/11.6 3940/14 4280/16 4600/19
90/70
11
Power (kW)/Air supply temp. (C) 37.9/61.3 43.7/58.3 49.1/55.8 54.1/53.7 58.7 /51.8 63.1/50.2
Water fow rate (l/h)/DP water (kPa) 1670/3 1930/4 2170/5 2390/6 2590/7 2790/8
15
Power (kW)/Air supply temp. (C) 35.3/62.7 40.8/59.8 45.8/57.5 50.4/55.4 54.7/53.7 58.8/52.2
Water fow rate (l/h)/DP water (kPa) 1560/3 1800/4 2020/4 2230/5 2420/6 2600/7
45/40
11
Power (kW)/Air supply temp. (C) 17.3/34 20.1/32.7 22.6/31.6 24.9/30.6 27.1/29.8 29.1/29.1
Water fow rate (l/h)/DP water (kPa) 3010/10 3500/12 3940/15 4340/18 4720/22 5070/24
15
Power (kW)/Air supply temp. (C) 14.9/35.1 17.3/34 19.4/33 21.4/32.2 23.3/31.5 25.1/30.8
Water fow rate (l/h)/DP water (kPa) 2600/7 3010/10 3380 /11 3730/14 4060/16 4370/19
60/50
11
Power (kW)/Air supply temp. (C) 24/43 27.9/41.1 31.3/39.5 34.5/38.2 33.6/38.8 40.3/36
Water fow rate (l/h)/DP water (kPa) 2110/5 2440/6 2740/8 3020/9 2940/9 3530/12
15
Power (kW)/Air supply temp. (C) 21.6/44.2 25/42.5 28.1/41.1 30.9/39.8 37.5/37.1 36.2/37.9
Water fow rate (l/h)/DP water (kPa) 1890/4 2190/5 2460/6 2700/8 3280/11 3170/10
BE for e
3
nhanced and e
3
lite versions - Electric Heater
Fresh Air 0C 0C -5C -10C -15C -20C
Qv (m/h) 4800 4800 4800 4800 4800 4800
Version
e
3
ssential e
3
nhanced BE 025 e
3
lite BE 025
Electric Heater Pre-Heater + Post-Heater
Total power (kW) - 6.75 6.75 13.5 18 + 6.75 18 + 13.5
Air supply Temp. (C) 16.6 20.8 20.3 19.7 20.9 20.9
-5C / 90% HR
+5C / 90% HR
0C / 90% HR
-10C / 90% HR
300Pa
250Pa
250Pa
200Pa
300Pa
200Pa
150Pa
150Pa
300Pa
200Pa
200Pa
R
e
t
u
r
n
a
ir
2
0

C
/ 5
0
%
E
f
f
ic
ie
n
c
y
(
%
)
-
E
N
3
0
8
p
e
r
f
a
n
P
o
w
e
r
c
o
n
s
u
m
p
t
io
n
(
W
)
S
t
a
t
ic
p
r
e
s
s
u
r
e
(
P
a
)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
Flow rate (m
3
/h)
80%
70%
60%
50%
40%
30%
Performance curves shown are based on the e
3
nhanced or e
3
lite product versions, with an Electric Post Heater fitted (i.e. BE variant).
Performance (in terms of pressure) for the e
3
ssential variant (with no heaters fitted) is approximately 25 Pa higher, while performance
(in terms of pressure) for the e
3
nhanced or e
3
lite versions, with a Hot Water Post heater fitted (i.e. BC variant) is 45 Pa lower than the BE variant.
Aerodynamic performance has been obtained from tests based upon EN 13053 and conform to ISO 5801.
Max Fan Pressure is optimum for HVAC applications. Data for higher pressures is available on request.
0.39 0.50 0.61 0.72 0.83 0.94 1.06 1.17 1.28 1.39
Flow rate (m
3
/s)
0.39 0.50 0.61 0.72 0.83 0.94 1.06 1.17 1.28 1.39
Flow rate (m
3
/s)
0.39 0.50 0.61 0.72 0.83 0.94 1.06 1.17 1.28 1.39
Flow rate (m
3
/s)
0.39 0.50 0.61 0.72 0.83 0.94 1.06 1.17 1.28 1.39
Flow rate (m
3
/s)
Notes:
1) Coil air on temperatures are based on 2 scenarios, where the external air temperature onto the plate heat exchanger is either -5C/90% RH
or 0C/90% RH, which typically result in plate heat exchange air off temperatures of 11C or 15C respectively, which we have then stated as
water coil air on temperatures.
2) Rated kW Powers and coil air off temperatures stated above are max valves, so should not be used to calculate heating loads.
Typical Plate Heat Exchanger Core Performance data
Thermal performance data for the Counter-flow Plate Heat Exchanger core is based
on a nominal Airflow per unit (approx. 80% of maximum) and the following air conditions:
External air temperature: -5C @ 90% RH and Return air temperature: 22C @ 50% RH
Model
Airfow rate
Recovered
kW
Air Off temp C / RH
Thermal
Efficiency % m
3
/h m
3
/s
Crown 90-6 3000 0.83 24.3 19.1C 16.4%RH 89.1
NSC4 = Sound level at 4 m,
in free field, intakes and
outlets connected up
Cooling coils available, please enquire for further details.
19
20
Modulation Solutions Flow Rate Modulation
HS air flow
LS air flow
Air flow
HS constant air flow
LS constant air flow
Air flow
CAV EC
Constant Air Volume
2 Constant Airflow Options
VAV TB EC
Variable Air Volume - Trickle & Boost Strategy
2 Air flow rates - Low Speed/High Speed
View of access to technical compartment
Access door to technical compartment
features integral display and user interface.
Remote control unit (optional)
HS air flow
LS air flow
Air flow
HS constant air flow
Air flow
LS constant air flow
COP EC
Constant Pressure Control
All control options use EC motor technology
VAV AQ EC
Variable Air Volume/CO
2
sensor & EC Fans
Proportional air flow control via CO
2
sensor
CAV AQ EC
Constant Air Volume/CO
2
sensor
2 Constant Airflow options controlled by
CO
2
sensor
The e
3
co Crown unit has a factory-programmable controller as standard, which can be used to configure how the
airflow can be modulated:
Constant pressure
Air flow
The e
3
co Crown ERU product includes an integral control panel with LCD display
mounted on the unit casing, and can be used to adjust time clocks, airflow rates,
temperatures (proportional control of the internal bypass, internal hot water coil for BC
version or electric heater for BE version, Night cooling). Fault alarms are also displayed.
Stop

HS Stop

LS

HS Stop

LS + LS

HS Forced Stop
e
3
co-Crown VAV TB EC
Variable Air Volume control (2
air flows) - Trickle and Boost
Functions
Clock Clock Clock + VF Contact #1
Easy LCD display or
remote control
or or or or
VF Contact #1 VF Contact #1 VF Contact #1 + VF Contact #1 VF Contact #1
e
3
co-Crown CAV EC
Constant Air Volume control (1 or
2 air flows). EC Fans Fitted
Clock Clock Clock + VF Contact #1
Easy LCD display or remote
control
or or or or
VF Contact #1 VF Contact #1 VF Contact #1 + VF Contact #1 VF Contact #1
e
3
co-Crown COP EC
Constant Pressure control at
Variable Air flows. EC Fans Fitted
Clock
Easy LCD display or remote
control
or or
VF Contact #1 VF Contact #1
e
3
co-Crown VAV AQ EC
PROPORTIONAL Variable Air
Volume control via CO
2
Sensor,
between 2 adjustable air flows. EC
Fans Fitted.
Clock + 0-10V CO
2
Probes
Easy LCD display or remote
control
or or
0-10V CO
2
Probes VF Contact #1
e
3
co-Crown CAV AQ EC
PROPORTIONAL control via CO
2

Sensor, between 2 Constant Air
Volumes (adjustable #2). EC Fans
Fitted.
Clock + 0-10V CO
2
Probes
Easy LCD display or remote
control
or or
0-10V CO
2
Probes VF Contact #1
Notes:
#1: Volt Free Contact can be either : Remote ON-OFF /
ON-OFF CO
2
Probe / ON-OFF Humidity Probe
#2 Except e
3
co-Crown 90-1
Control Function Options:
Standard Function Optional Function
21
22
Sound Data Product Codes
As standard, integrated controls can manage one or several heaters
(depending on the unit version selected : e
3
ssential, e
3
nhanced or e
3
lite)
Climate Solutions
Integrated Coil
Crown
Type
Pre-Heating Heating
Electric coil Electric coil Water water coil
e
3
ssential - - -
e3nhanced BC - -

e3nhanced BE -

-
e3lite BC

e3lite BE

-
1 2 3 4 5
e
3
co-CROWN 90-1 L - P - W - Y e
3
ssential Controls
e
3
nhanced BC/BE xxx
e lite BC/BE xxx
1 - High Thermal Efficiency unit (90%) - complete with automatic control and Counter Flow Plate Heat Exchanger
2 - Unit Model Code Examples:

90-1 Efficiency = 90%, Unit size = 1 (0.22 m
3
/s)
90-5 Efficiency = 90%, Unit size = 5 (1.00 m
3
/s)

3 - Unit Configuration Options:
L & P: Side-by-Side format (except unit model 90-6)
W & Y: Double Deck format

4 - Unit Version Options:
e
3
ssential Unit with NO coils fitted
e
3
nhanced BC Hot water coil (POST Heater) plus appropriate controls fitted
e
3
nhanced BE xxx Electric heater (POST Heater) plus appropriate controls fitted
e
3
lite BC Unit with Electric PRE-Heater and hot water POST Heater plus controls
e
3
lite BE xxx Unit with Electric PRE-Heater and Electric POST heater plus controls

For BE versions, the xxx relates to the power rating of the electrical heater. Options shown below:
BE 025 = 2.50 (single phase)
BE 037 = 3.70 (single phase)
BE 052 = 5.25 (three phase)
BE 067 = 6.75 (three phase)
BE 082 = 8.25 (three phase)
BE 105 = 10.5 (three phase)
BE 135 = 13.5 (three phase)
5 - Controls:
VAV TB EC (Std) - Variable Air Volume Trickle and Boost
VAV AQ EC - Variable Air Volume and CO
2
Sensor
CAV EC - Constant Air Volume
CAV AQ EC - Constant Air Volume and CO
2
Sensor
COP EC - Constant Pressure - All motors are EC Type
All units feature EC motors



Accessory Options
Weather Roof
Code: WR
For Outdoor installation.
Pre-Painted Steel
(RAL 7035)
Motorized Damper
Code: MD
For Unit shut-off and
Frost protection.
Features Opposed blades
Rain Cowl
Code: RC
Complete with safety grille
(bird guard)
Constructed from
Galvanised Steel
Support Legs (set of 4)
Code: SLK
Can be used instead of
Integral mounting brackets
Flexible Connectors
Code: FC MO
Circular: 315 to 630mm
ElectroValve Kit
Code: EVK
0-10V motorized 3 way valve
for used with e
3
nhanced
and e
3
lite BC
Available IP 41 or IP 54
Damper Motor
Code: DA
Open / Closed 24V
Servo Motor to control
Fresh air damper and to
provide Frost protection
Remote Control
Code: RC-10ML
Additional LCD display
Can be used local to Easy
Control compartment
or remote (10m) from unit
BMS Controller Unit
Code: BCU
Controller with LON or
TCP/IP BMS protocol
Control Repeater Unit
Code: CRU
Repeater unit used to
Booster control signal
between 10m and 1km
from unit
Model
In-duct Sound Power Levels (Supply Air and Exhaust Air Connections) Breakout
dBA @
3m
SFP
63 Hz 125 Hz 250 Hz 500 Hz 1 KHz 2 KHz 4 KHz 8 KHz Lw LwA
Crown 90-1 66 65 67 68 64 59 56 56 73 69 33 0.85
Crown 90-2 64 65 66 69 64 58 57 61 74 70 34 0.88
Crown 90-3 66 69 70 68 68 60 57 55 76 71 35 0.72
Crown 90-4 65 69 71 68 67 60 57 55 76 71 35 0.72
Crown 90-5 65 72 73 72 69 66 63 65 78 74 39 1.06
Crown 90-6 70 78 79 78 75 73 70 72 85 81 45 1.01
Acoustic data has been obtained from tests based upon the EN 13053 standard
Flkt Woods operates a policy of continuous improvement and reserves the right to supply products that may differ from
those illustrated and described in this publication. Certified dimensions can be supplied on request on receipt of order.
Flkt Woods Limited
Axial Way, Colchester, Essex C04 5ZD
Tel 01206 222 555 Fax 01206 222 777
email info.uk@flaktwoods.com www.flaktwoods.com
See global website for international sales offices www.flaktwoods.com
We Bring Air to Life
Flkt Woods is a global
leader in air management.
We specialise in the design
and manufacture of a wide
range of air climate and air
movement solutions. And
our collective experience
is unrivalled.
Our constant aim is to
provide systems that
precisely deliver required
function and performance,
as well as maximise
energy efficiency.
Fans
Advanced axial, centrifugal and
boxed fans for general and specialist
applications. Comprehensive range
including high temperature and
ATEX compliant options. Engineered
for energy efficiency and minimised
life cycle cost.
Air Handling Units (AHUs)
Modular, compact and small
AHU units. Designed to ensure
optimisation of indoor air quality,
operational performance and
service life.
Chillers
Air-cooled and water-cooled chillers
with cooling capacity up to 1800kW.
Designed to minimise annual energy
consumption in all types of buildings.
Chilled Beams
Active induction beams for
ventilation, cooling and heating,
and passive convection beams
for cooling. For suspended or
flush-mounted ceiling installation
and multi-service configuration.
With unique Comfort Control and
Flow Pattern Control features.

Solutions for all your air climate and air movement needs
Flkt Woods is the only company in the UK capable of providing total system
solutions from the following portfolio:
Smoke control and car park
ventilation systems
Unique approach to car park
ventilation, aided and optimised
by Computational Fluid Dynamics
(CFD) software. Complete turnkey
solutions for designing, installing
and commissioning mechanical
and natural smoke ventilation.
Controls and drives
Variable speed drives and control
systems, all tested to ensure total
compatibility with our products.
Specialist team can advise on energy
saving and overall system integration.
Technical Site Services
Our dedicated team providing
comprehensive post-installation
services. Including condition-based
contract monitoring, preventative and
routine maintenance, refurbishment
and system upgrades.
U
K
/
P
B
E
S
C
-
0
1
/
0
9
1
1
Flkt Woods operates a policy of continuous
development and improvement. Accordingly, the
Company reserves the right to supply products that
may differ from those illustrated and described in this
publication. Certified dimensions will be supplied on
request on receipt of order.