Sunteți pe pagina 1din 6

ELECTRIC ACTUATOR NA SERIES

Distributed by

EUNHA MACHINERY INDUSTRIAL CO., LTD.(EMICO)

Noah Series of

Electric Actuators are particularly suitable for quarter turn applications in piping, ducting and in various plants such as water treatment, pulp, paper, ship building and air conditioning combined with ball, butterfly, plug valves and dampers. Its compact and simple design will assure reliability and quality for customers even in hazardous locations. Noah Series of Electric Actuators give the best automation solutions to you with its various models (60Nm~2,500Nm) and options.

Table of Contents
CONFIGURATION FEATURES OPTIONAL PERFORMANCE SPECIFICATION STANDARD / OPTIONAL DIMENSION TABLE OF AVAILABLE VALVE SIZE FOR ACTUATOR 4 5 6 8 8 9 10 10 11

www.emico.co.kr

THE METHODS OF CALCULATION TO FIT DAMPER CUSTOMER SERVICES

Noah

CONFIGURATION

The dome type indicator is directly mounted on the center column to provide positive visual indication of the valve position even over long distances.

Squirrel caged induction motor is totally enclosed type with high stall torque and low inertia force to suit seating/unseating of valves. Integral thermal protection to prevent damage to the single/three phase motor.

FEATURES
SEALING Standard enclosure with o-ring sealing is watertight to IEC IP67, NEMA4 and 6. The actuator is available with optional explosion proof enclosure. WIRING Electric wiring of control circuit is standardized for single and three phase power supply in a single module. Multiple terminal contacts sufficiently cover additional requirements such as auxiliary contacts for DCS, interlocking and other options. COMPONENT ARRANGEMENT Mechanical and electrical module can be separated easily to improve assembling, maintenance and alteration of electrical requirements. Actuator has enough internal space for optional accessories. HANDWHEEL Size of handwheel is designed for safe and efficient emergency manual operation. MANUAL OVERRIDE Hand/auto declutching lever for handwheel engagement. The power drive is automatically restored by motor start. ADAPTION Base mounting is standard to ISO 5211. Drive bush is removable for machining to valve stem requirement. The actuator position on the valve can be selected for 4 positions by means of 4 bolt holes in the drive bush. HEATER A space heater inside the actuator prevents condensation due to temperature and weather changes. Standard 20W heater keeps all electrical components in the actuator clean and dry.

Quality terminal block containing segregated power and control terminals are designed for use in high vibration environments.

One each for Open and Closed.

Hand/Auto declutching lever for engagement of handweel. The power drive is automatically resorted by the motor starting.

LIMIT SWITHCHES The limit switch is activated by means of a simple and yet reliable cam mechanism mounted and driven by the center column. The valve position can be accurately and easily set with the simple adjustable switch mechanism. The set position is permanent and is not affected by over-travel resulting form manual operation. TORQUE SWITHCHES Cam activated torque switches are easily adjustable to provide over-load protection.

www.emico.co.kr

5
The precision worm and worm wheel mechanism transfers high torque with high efficiency and low sound level (Max. 50dB) even though small in size. Additional benefits include low backlash and longer life. Various output torques (60Nm~2,500Nm) cater for valves from 2 24 to .

SELF-LOCKING Rolled steel wormgear on aluminium bronze wormwheel selflocks to prevent valve back drive on control signal or power failure.

OPTIONAL

Providing the dry contact signal to check valve positions (cam switches s structure).

A small unit that is mounted to the actuator to operate the valve s position in local. Local/Remote switch Open/Stop/Close switches

Providing the dry contact signal send to customer panel as fault signal s (cam switches structure). Rugged structure with special parts (Explosion proof type Selector, pushbutton switches) Guarantees that watertight and safety working in hazardous environments. Combined with PIU and transfer out put signal (DC : 4 ~ 20mA) from PIU value of resistance s power : AC 110/220V 10% 50/60Hz DC24V output signal : DC 4-20mA Providing resistance value (0~1K) according to valve position. s

Combined with PIU and control the valve s position proportionally by input signal and provide valve position as their output s signal.
Input signal : DC 4 ~ 20mA/ DC 2 ~ 10V/ DC 1 ~ 5V Output signal : DC 4 ~ 20mA Power : AC 110/220V 10% 50/60Hz/ DC 24V Size : 120mm 135mm Operating temperature : -10 ~ 55 Resolution : Min. 1/500 Operating Humidity : 90% RH Max. (Non condensing)

www.emico.co.kr

Applicable Function
Auto Scan - Automatically memorized each open/close position by the signal of PIU. (It is very easy to set the PCU even in local area only requiring one push of the Auto Scan button) Fail close - Drives to close position there is no certain input signal. Fail open - Drives to open position there is no certain input signal. Manual operation mode - Zero Null/ Span Open. Optional Setting - It is possible to fix a certain signal as Open and Close. Manual Operating - Locally move valve position without source of signal s by direct use of dip switch on PCU board.

Combined transformer with electric contactor and directly provides various control voltages to the Actuator (24VDC, 110VAC/220VAC) from main power (380VAC /440VAC).

PERFORMANCE
TYPE Max Output Torque Kg/m Operating Time 60/50 Hz 90 Deg. Max Stem Dia mm Motor Class F W Rated Current ( mA ) 1 Phase 110V 220V 3 Phase 380V 440V Number of Hand Wheel Turns Weight (f)

DIMENSION

NA 06 NA 09 NA 15 NA 19 NA 28 NA 38 NA 50 NA 60 NA 80 NA 100 NA 150 NA 200 NA 250

6 9 15 19 28 38 50 60 80 100 150 200 250

14 / 17 14 / 17 17 / 20 17 / 20 20 / 24 20 / 24 20 / 24 24 / 29 24 / 29 24 / 29 72 / 87 72 / 87 72 / 87

22 22 22 22 32 32 32 42 42 42 75 75 75

15 25 40 40 40 60 90 90 180 180 90 180 180

750 1200 1600 1600 1800 2300 3900 3900 4700 4700 3900 4700 4700

450 580 950 950 950 1300 1500 1500 2150 2150 1500 2150 2150

130 170 300 300 330 360 560 560 840 840 560 840 840

125 160 300 300 340 340 570 570 780 780 570 780 780

8.5 8.5 10 10 12.5 12.5 12.5 14.5 14.5 14.5 43.5 43.5 43.5

11 11 12 13 17 18 19 22 23 25 68 70 70

STANDARD SPECIFICATION
Enclosure Ambient Temperature Power Supply ( 60 / 50 Hz ) Control Power Torque Switches Limit Switches Stall Protection Travel Angle Indicator Manual Override Self Locking Mechanical Stops Space Heater Conduit Entries Lubrication Materials Surface Treatment External Coating Watertight Ingress Protection 67 Nema 4 and 6 20 to +70, 150 / 1hr 110 / 220 VAC , 1 Phase 380 / 440 VAC , 3 Phase 110 / 220 VAC , 1 Phase , 60 / 50 Hz 2 Open / Close ( Except NA 06 , NA 09 ) 2 Open / Close, 250 VAC 16A Rating Built - in Thermal Protection (Open 150 5 / Close 97 15) 90 5 Continuous Position Indicator Hand / Auto Declutching Mechanism Provided by means of Worm Gearing External Adjustable Screws 20 W (110 / 220 VAC , 24 VDC ) Two PF 3 / 4(NPT 3/4 ) Grease Moly (EP Type) Steel, Aluminium Alloy , All Bronze Anodizing Dry Powder, Epoxy - Polyester, Polyester(TGIC-Free)

OPTIONAL SPECIFICATION
EXP DCM ALS EXT LCU Explosion Proof & Watertight Enclosure Ex d B T4 IP 67 , EEx d B T4 (NEMKO) 24 V DC Motor Additional Auxiliary Limit Switches Travel Angle 120, 135, 180, 270, 300 Local Control Unit Local / Remote Selector Switch Open / Stop / Close Selector Switch or Push button type Potentiometer Unit 1K Ohm. Current Position Transmitter Output : DC 4-20mA Proportional Control Unit Power : AC 110/220V 1PH , DC 24V Input : DC 4-20mA, DC 1-5 V, DC 2-10 V Output : DC 4-20 mA Integral Motor Starter Reversing Magnet Contacts and Transformer

PIU CPT

PCU

IMS

TYPE Flange ISO 5211 A A B B C D(MAX) E F G H I J K L M N O P Q R S T U X Y Z

NA06 NA09 F07 70 M8 12 22 55 43 2 231 56 175 60 213 273 102 68 113 181 108 102

NA15 NA19 F07 F10 70 102 M8 M10 15 22 57 43 2 261 77 184 60 213 273 120 85 139 224 108 102

NA28 NA38 NA50 F10 F12 102 125 M10 M12 18 32 75 52 2 285 83 202 70 250 320 145 99 159 258 130 125

NA60 NA80 NA100 NA150 NA200 NA250 F12 F16 F14 F14 125 165 140 *140 M12 M20 M16 *M14 *M16 22 30 42 75 85 100 59 126 2 7 325 325 99 99 226 226 78 78 283 283 361 361 175 266 116 116 191 191 307 307 178 178 170 170 556 195 388 16 318

www.emico.co.kr

for optional alternative flanges

TABLE OF AVAILABLE VALVE SIZE FOR ACTUATOR

CUSTOMER SERVICES
When an actuator leaves our factory it not only has the Noah name attached it has with it our true heart as well. Our mottos, Quality First and Fast Delivery have satisfied and will continue to satisfy customers around the world. Many things have changed over the past decade and many things will change in the decade to come, but our mottos will remain the same.

TYPE NA 06 NA 09 NA 15 NA 19 NA 28 NA 38 NA 50 NA 60 NA 80 NA 100 NA 150 NA 200 NA 250

BUTTERFLY VALVE 80A 100A 125A 150A 200A 250A 300A 350A 400/450A 500A 600A

2-WAY BALL VALVE 40A 50A 65A 80A 100A 125A 150A 200A 250A 300A

3-WAY BALL VALVE

40A 50A 65A 80A 100A 125A 150A

200A 250A

Butterfly Valve(on/off)

Ball Valve(on/off)

THE METHODS OF CALCULATION TO FIT DAMPER


Base Processing
Noah Electric Actuator Test Report

Center Column Assembling

T=

d P 10-91.8 = 12n
3

T=

a bP 10-91.8 = 8n
2

Messer(S)

Test Power Source: NA-06 025839 + BUTTERFLY V/V + BALL GREASE MOLY

230V.

1 Phase.

50Hz

Project Name :
Type Order No. Serial No. M. O. V. Lubricant Type & Size Construction Handwheel Turn Torque Setting Size M Duty O Power Source T Control Source O Rated Current R Rated Started Torque Motor Suppil V/V + DAMPER 15W, 4P 230V. 1Ph

Functional Test :
NA-06 Gear Ratio Weather Proof Drive Steeve Counter Clockwise to open Base Mounting Apprex 8.5Rev Kg-m Open Traveling Time Close Kg-m Max 9.97Kg-m Specified Time Insulation 15W Pole 15Min 230V. 1Ph 230V. 1Ph 0.42A Insulation Res(500MV) 1,200/1,400 Insulation Potential Test 1,462:1 1.00RPM ISO05211 Fo7 17.0Sec/90 17.0Sec/90 17.0Sec/90 F 4

AC 1,800/1sec

Torque Graph

Test result for Actuator


1. Function of Manual and Electric operating 2. Function of Limit switches 3. Function of Torque switches 4. Function of Position indicator 5. Wiring (NU-11000-B) 6. Oil leakage 7. Appearance painting 8. Overall dimensions 9. Space Heater 10. Options OK OK OK OK OK OK OK OK OK OK

www.emico.co.kr

10 11

Tested By : Approved By : Date :

S.J.Kim R.G.Lee

Test Report Rod Box

Torque Test of Actuator

S-ar putea să vă placă și