Documente Academic
Documente Profesional
Documente Cultură
G6S
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6S-2F-DC12).
STANDARD VERSION
Part number
Terminal
Gull-wing
Inside L
PCB through-hole
Contact form
DPDT
DPDT
DPDT
Non-latching
G6S-2F
G6S-2G
G6S-2
EUROPEAN VERSION
Certified for EN60950/EN41003 Supplementaty Insulation at 250 V
Terminal
Gull-wing
Inside L
PCB through-hole
Contact form
DPDT
DPDT
DPDT
Part number
Non-latching
G6S-2F-Y
G6S-2G-Y
G6S-2-Y
High-sensitivity
dual coil latching
G6SK-2F-H
G6SK-2G-H
G6SK-2-H
G6S
G6S
Specifications
CONTACT DATA
Load
Rated load
Contact material
Max. carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
COIL DATA
G6S Standard non-latching (G6S-2F, G6S-2G, G6S-2)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
()
Pick-up
voltage
3
4.5
5
6
9
12
24
46.7
31.0
28.1
23.3
15.5
11.7
8.3
64.3
145
178
257
579
1,028
2,880
75% max.
75% max.
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
10% min.
200% max.
140
10% min.
170% max.
200
Maximum
voltage
% of rated voltage
75% max.
75% max.
Power
consumption
(mW)
180% max.
100
75% max.
180% max.
150
Set pick-up
voltage
Reset pick-up
voltage
% of rated voltage
Rated
current
(mA)
Coil
resistance
()
3
4.5
5
6
9
12
24
33.3
22.2
20.0
16.7
11.1
8.3
6.3
90
203
250
360
810
1,440
3,840
Set pick-up
voltage
Reset pick-up
voltage
75% max.
Set coil
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
()
Reset coil
Rated
current
(mA)
Coil
resistance
()
3
4.5
5
6
9
12
24
66.6
44.4
40.0
33.3
22.2
16.7
12.5
45
101
125
180
405
720
1,920
66.6
44.4
40.0
33.3
22.2
16.7
12.5
45
101
125
180
405
720
1,920
Maximum
voltage
% of rated voltage
75% max.
75% max.
Power
consumption
(mW)
170% max.
200
75% max.
140% max.
300
75% max.
G6S
G6S
Rated
current
(mA)
Coil
resistance
()
Reset coil
Rated
current
(mA)
Coil
resistance
()
3
4.5
5
6
9
12
24
46.7
31.0
28.1
23.3
15.6
11.7
8.33
64.3
145
178
257
579
1,028
2,880
46.7
31.0
28.1
23.3
15.6
11.7
8.33
64.3
145
178
257
579
1,028
2,880
Set pick-up
voltage
Reset pick-up
voltage
Maximum
voltage
% of rated voltage
75% max.
75% max.
Power
consumption
(mW)
130% max.
140
75% max.
75% max.
130% max.
200
Maximum
voltage
% of rated voltage
75% max.
10% min.
Power
consumption
(mW)
130% max.
200
75% max.
110% max.
230
Rated
current
(mA)
Coil
resistance
()
3
4.5
5
6
9
12
24
66.7
44.6
40.0
33.3
22.2
16.7
9.58
45
101
125
180
405
720
2,504
Note: 1.
2.
3.
4.
Pick-up
voltage
Dropout
voltage
10% min.
The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10%.
The operating characteristics are measured at a coil temperature of 23C (73F) unless otherwise specified.
Pick-up voltage is measured with no carry current across the contacts.
Pick-up voltage will vary with temperature.
CHARACTERISTICS
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service life
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
Weight
75 m max.
4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK)
4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK)
Approx. 0.5 ms
1,000 M min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts
1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
2,500 V, 2 x 10 S (conforms to Bellcore specifications) for G6S and G6SU;
1,500 V, 10 x 160 S (conforms to FCC part 68) for G6SK between coil and contacts
2,500 V, 2 x 10 S (conforms to Bellcore specs.) between contacts of different poles
1,500 V, 10 x 160 S (conforms to FCC part 68) between contacts of same pole
10 to 55 Hz; 5 mm (0.20 in) double amplitude
10 to 55 Hz; 3.3 mm (0.13 in) double amplitude
1,000 m/s2; approx. 100 G
750 m/s2; approx. 75 G
-40 to +85C (-40F + 185F)
35 to 85% RH
100,000,000 operations min. (at 36,000 operations/hour)
See "Characteristic Data"
Approx. 2g (0.07 oz)
G6S
G6S
CHARACTERISTIC DATA
Ambient temperature vs.
maximum coil voltage (G6S)
10
7
250
AC
resistive
load
A
1
0.7
0.5
DC
resistive
load
0.3
250
3-12 VDC
Maximum coil voltage
(% of rated voltage)
200
170
150
24 VDC
100
G6SU
200
180
170
150
140
100
B
50
0.1
10
30
50 70 100
50
0
-40
-20
20
40
60
80
0
-40
100
-20
80
100
0.4
0.6
0.8
Service life (x106 operations)
Resistive load: 100mA, 50 VDC
Ambient temperature: +85
1.0
1500
2000
2500
3000
Breakdown voltage (V)
3500
20
40
60
Service Life
500
500
500
300
200
100
50
30
300
200
100
50
30
20
10
1000
1000
1000
20
0.2
0.4
0.6
0.8
Service life (x106 operations)
Resistive load: 10mA, 10 VDC
Ambient temperature: +85
10
1.0
300
200
100
50
30
20
0.2
0.3
0.4
Service life (x106 operations)
Resistive load: 100mA, 28 VDC
Ambient temperature: +85
0.1
10
0.5
0.2
500
50
50
40
40
100
70
50
30
200
300
30
20
0.4
0.8
1.2
1.6
2.0
0
1000
1500
2000
2500
Breakdown voltage (V)
3000
20
10
10
10
30
3500
1000
G6S
G6S
(10 x 160 s)
3500
4000
4500
5000
5500
Breakdown voltage (V)
(10 x 160 s)
15
10
0
1500
6000
2000
2500
3000
3500
Breakdown voltage (V)
4000
3500
4000
4500
5000 5500
Breakdown voltage (V)
6000
(10 x 160s)
4000
4500
5000
5500
6000
Breakdown voltage (V)
10
0
1500
6500
(2 x 10 s)
15
2000
2500
3000
Breakdown voltage (V)
3500
4000
4000
4500
5000
5500 6000
Breakdown voltage (V)
6500
50
50
40
40
Number of contacts (pcs.)
30
20
10
30
20
10
1500
2000
2500
3000
3500
4000
1500
2000
2500
3000
3500
Breakdown voltage (V)
Between contacts of different poles
Between contacts of same pole
4000
G6S
G6S
Dimensions
Unit: mm (inch)
STANDARD
G6S-2F,
G6S-2F-Y
Terminal arrangement/
Internal connections
(Top view)
7.3 0.2
(.287) max.
14.8 0.2
(.583) max.
12
G
12 6S
V 2F
D
C
IN
95
0.25
(.01)
2.54
(.10)
1.25 0.2
(.05)
9.2 +0.5
-0.3
2.54
(.10)
7.3 0.2
(.287) max.
12
9.2 0.2
(.362) .65
max. (.026)
0.25
(.01)
1.25 0.2
(.05)
2.54
(.10)
14.8 0.2
(.583) max.
G
12 6S
V 2-Y
D
C
10
8
6.1
2.2 (.24)
(.087)
95
2.54
(.10)
1.0
(.039)
4.9 +0.3
-0.5
Terminal arrangement/
Internal connections
(Bottom view)
AN
JA
7.3 0.2
(.287) max.
+
12
.50
(.019)
4.9 +0.3
-0.5
Mounting holes
(Bottom view)
2.54
(.10)
Orientation mark
1
5.08
(.20)
Mounting pads
(Top view)
G6S-2,
G6S-2-Y
.50
(.019)
5.08
(.20)
IN
Orientation mark
G
12 6S
V 2G
D
C
PA
JA
1.0
(.039)
AD
8.0
2.2 (.315)
(.087)
Terminal arrangement/
Internal connections
(Top view)
14.8 0.2
(.583) max.
+
1
G6S-2G,
G6S-2G-Y
IN
.50
(.019)
5.08
(.20)
E
AD
10
JA
Orientation mark
PA
AD
Mounting pads
(Top view)
8 - 1 dia.
holes
2.54
(.10)
5.08
(.20)
10
8
10. 16 0.1
1.0
(.039)
1.11
(.04)
G6S
G6S
G6SU-2F
7.3 0.2
(.287) max.
14.8 0.2
(.583) max.
12
G
12 6S
U
V -2
D F
C
IN
JA
0.25
(.01)
2.54
(.10)
1.25 0.2
(.05)
2.54
(.10)
9.2
7.3 0.2
(.287) max.
2.54
(.10)
10
8
6.1
2.2 (.24)
(.087)
SR
+_
0.25
(.01)
1.25 0.2
(.05)
2.54
(.10)
G
12 6S
U
V -2
D G
C
Mounting pads
(Top view)
95
4.9
1.0
(.039)
+0.3
-0.5
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Bottom view)
7.3 0.2
(.287) max.
PA
JA
5.08
(.20)
+SR
-+
12
.50
(.019)
0.25
(.01)
2.54
(.10)
2.54
(.10)
5.08
(.20)
2.54
(.10)
Orientation mark
1
G
12 6S
U
V -2
D C
_+
14.8 0.2
(.583) max.
IN
Orientation mark
12
9.2 0.2
(.362) .65
max. (.026)
G6SU-2
1.0
(.039)
.50
(.019)
5.08
(.20)
AD
8.0
2.2 (.315)
(.087)
SR
+_
1
PA
JA
Terminal arrangement/
Internal connections
(Top view)
14.8 0.2
(.583) max.
IN
+0.5
-0.3
G6SU-2G
E
AD
10
_+
95
4
.50
(.019)
5.08
(.20)
Orientation mark
PA
AD
Mounting pads
(Top view)
8 - 1 dia.
holes
2.54
(.10)
5.08
(.20)
10
8
10. 16 0.1
1.0
(.039)
1.11
(.04)
G6S
G6S
Unit: mm (inch)
G6SK-2F,
G6SK-2F-H
7.3 0.2
(.287) max.
14.8 0.2
(.583) max.
G
12 6S
K
V -2
D F
C
IN
A
AP
95
0.25
(.01)
2.54
(.10)
2.54 2.54
(.10) (.10)
1.25 0.2
(.05)
9.2
7.3 0.2
(.287) max.
12
2.54 2.54
(.10) (.10)
G
12 6S
K
V -2
D -
C
M
6.1
2.2 (.24)
(.087)
+
3
5 6
95
1.0
(.039)
4.9 +0.3
-0.5
5.08
(.20)
5 6
+
S
12
0.25
(.01)
2.54 2.54
(.10) (.10)
2.54
(.10)
5.08
(.20)
Note: 1. 123456
Coplanarity is 0.1 mm max.
123456
123456
2.
and
indicate mounting orientation marks.
10 - 1 dia.
holes
Orientation mark
1
Mounting holes
(Bottom view)
2.54
(.10)
7.3 0.2
(.287) max.
PA
JA
.50
(.019)
Terminal arrangement/
Internal connections
(Bottom view)
14.8 0.2
(.583) max.
2.54
(.10)
10 9 8 7
0.25
(.01)
1.25 0.2
(.05)
2.54
(.10)
Mounting pads
(Top view)
5.08 2.54
(.20) (.10)
G6SK-2,
G6SK-2-H
IN
5 6
9.2 0.2
(.362) .65
max. (.026)
.50
(.019)
5.08
(.20)
E
AD
Orientation mark
JA
1.0
(.039)
PA
IN
8.0
2.2 (.315)
(.087)
+0.5
-0.3
G
12 6S
K
V -2
D G
C
Terminal arrangement/
Internal connections
(Top view)
14.8 0.2
(.583) max.
AD
+
1
G6SK-2G,
G6SK-2G-H
9 8
.50
(.019)
5.08
(.20)
10
AD
Mounting pads
(Top view)
+
R
10 9 8
2.54
(.10)
5.08
(.20)
7
1.0
(.039)
12..70.1
1.11
(.04)
G6S
G6S
ACCESSORIES
Tube packing
Tape packing
Standard nomenclature
50 pcs per anti-static tube
When ordering, add TR before the rated coil voltage (e.i., G6S-2F-TR-DC12)
Note: TR is not part of the relay model number and will not be marked on the relay
DIMENSIONS
Relays per reel: 400
Reels per packing carton: 2 (800 relays)
+2
24.4.-0
(.961)
20.5
(.0.79)
29.41.0 (1.16)
Orientation mark
210.8
(.827)
Feed
direction
Cover tape
330
(12.99)
80
(3.15)
R1.0
130.2
(.512)
Carrier tape
Emboss tape
APPROVALS
UL (File No. E41515)/ CSA (File No. LR24825)
Type
G6S-2F
G6S-2F-Y
G6S-2G
G6S-2G-Y
G6S-2
G6S-2-Y
G6SU-2F
G6SU-2G
G6SU-2
G6SK-2F
G6SK-2G
G6SK-2
G6SK-2F-H
G6SK-2G-H
G6SK-2-H
Contact Form
DPDT
Coil Rating
1.5 to 48 VDC
Contact Ratings
0.5 A, 125 VAC
0.3 A, 110 VDC
2.0 A, 30 VDC
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance
characteristics individually defined in this catalog.
1-800-55-OMRON
416-286-6465
9/97