Sunteți pe pagina 1din 4

Control Valve Sizing Calculations

(Liquid)
Temp
o

Qop

P1

P2

P1

DP

(bar-g)

(bar-abs)

(bar)

1.00

2.413

0.40

ID (mm)

FL

Cv @100%

( C)

(m /h)

(bar-g)

DCPI+PHO

150

3.3

1.40

Nominal Size

DN

Liquid

Schedule OD (mm)

Upstream

50

40S

60.30

52.94

Control Valve

50

Globe

Equal %

50.00

Downstream

50

40S

60.30

52.94

0.85

DPs

Pv

Pcr

(bar-g)

(bar-g)

1.18

0.017

220.60

2.397

zReducer

zBernoulli

Sz

FP0

0.00000

0.0000

0.00000

0.00000

S.G.

58.20

1.00

FLP0
0.85

%DP

%Qop
75%

10%

2.475

Cv-op

0.04

FP

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

FLP

0.850

0.850

0.85

0.850

0.850

0.850

0.850

0.850

0.850

0.850

0.850

0.850

% Open
Cv

31.6%
4.91

41.4%
6.55

65.1%
20.70

10%
1.74

20%
3.15

30%
4.72

40%
5.91

50%
10.60

60%
16.30

70%
25.00

80%
36.70

90%
47.80

DP
DPmax

0.40
1.73

0.40
1.73

0.04
1.73

5.66
1.73

1.73
1.73

0.77
1.73

0.49
1.73

0.15
1.73

0.06
1.73

0.03
1.73

0.01
1.73

0.01
1.73

Qmax

5.15

6.87

21.71

1.82

3.30

4.95

6.20

11.12

17.09

26.22

38.49

50.13

0
41.4%
65.1%
31.6%

2
41.4%
65.1%
31.6%

4
41.4%
65.1%
31.6%

6
41.4%
65.1%
31.6%

8
41.4%
65.1%
31.6%

10
41.4%
65.1%
31.6%

12
41.4%
65.1%
31.6%

14
41.4%
65.1%
31.6%

16
41.4%
65.1%
31.6%

8.00
7.00

From Catalogue

Cv
dP
dPmax
Qmax
Operating Point
%dP
%Qop

DP [bars]

6.00
5.00
4.00
3.00
2.00
1.00
0.00
10%

20%

30%

40%

50%

Page 1 of 4
% Valve Opening

60%

70%

80%

Control Valve Sizing Calculations


(Liquid)

% Valve Opening

Reference: Fisher Control Valve Sizing Handbook

Page 2 of 4

Control Valve Sizing Calculations


(Liquid)

1.000
0.850
100%
58.20
0.01
1.73
61.04
18
41.4%
65.1%
31.6%

ating Point

Page 3 of 4

Control Valve Sizing Calculations


(Liquid)

Page 4 of 4