Utility Company Case Study

This client is one of the biggest Utility companies in the Philippines. Their franchise area covers 31 cities and 80 municipalities, including Metro Manila, the entire provinces of Bulacan, Rizal and Cavite; parts of the provinces of Laguna, Quezon, Batangas and Pampanga.

The solution
Initial inspection was done to insure the UPS will fit into the limited space. The Mega Power+ with its 25 kVA per module was just the right size for their requirement as well as the space limitations. An extra benefit was the reduced noise

Customer Profile
This company repeatedly appears on the list of the Philippines top five corporations and cited among Asias finest. Serves over 4.8 million residential, commercial and industrial customers. It is strategically located to serve the countrys center of commerce and industry and its hub of government services and infrastructures. It services about 30 manufacturing economic zones, which also compete in the global market. Likewise, the Company caters to providers of outsourced business processes, both domestic and international.

level compared to the conventional pervious UPS .

Mega Power+ 125kVA/kW to 500kVA/kW


The Mega Power+ is a state of the art modular redundant UPS System - With a capacity to grow up to 500kVA (with 25kW increments). The products unbelievable small footprint and high efficiency makes it one of the worlds leading solutions in its range. The product is utilized in many Datacenter rooms, hospitals,

The Challenge
Due to the increasing demand for their data center, the company decided to upgrade. Their data is very important thus the data center supply must be protected by an advanced UPS system which can be upgraded when additional power is needed. Due to the sensitivity of their data center equipment the UPS must be on-line at all times even when a quick repair or maintenance is required. Another big challenge was the limited space in the data center room. Therefore the 4x50kVA conventional UPS were replaced by the Mega Power+.

institutions, manufacturing & industrial applications, telecom datacenters as well as many other segments.

Utility Company Case Study


System Characteristics
Highest efficiency rate of 96% Significant energy and cooling savings Maximum Availability and Minimal Downtime The Highest Power Density / Smallest Footprint (25kVA/ kW 3U and saves space in data centers, IT rooms and other critical hosted sites) All connections and cables are internal. Minimal access to the sides and rear of the unit is required FRONT access only Highest level of load availability: Even if a module fails, it will not influence the system operation and load availability. The system will continue to work uninterrupted Flexible scalability: Mega Power+ ensures future growth when load increases . This scalability feature enables the user/designer unprecedented flexibility Minimal maintenance: Mega Power+ delivers almost zero MTTR (Mean Time To Repair), which results in the best service with minimal costs Minimal maintenance: Mega Power+ delivers almost zero MTTR (Mean Time To Repair), which results in the best service with minimal costs Mega Power+ performs unity output PF 250kVA = 250kW. The UPS is perfectly suitable for loads, such as blade servers with lower power factor Gamatronic understands that energy-savings is not only a matter of cost-savings, but also of social responsibility. Mega Power+ clean and globally responsible energy technology meets and exceeds power requirements, while minimizing environmental impact Each Mega Power+ features a unique and proprietary Controller, which is the users main interface with the Mega Power+. The Controller features a colored, touchsensitive screen which enables the user to navigate through the system screens by pressing various icons. Multilanguage functions allow simple usage worldwide. The Controller is not a failure point and the UPS operation is not interrupted if the Controller is removed. Its interface offers up-to-the-minute, intelligent monitoring of all UPS parameters including intelligent battery monitoring functionality, system voltage, temperature etc. Each system element has its own Control and History Log. Built in SNMP/TCIP & optional GPSR/SMS interface provides complete control over units operation without installing software or using dedicated computers or control hardware