Documente Academic
Documente Profesional
Documente Cultură
21/05/2012
Kind Attention : Mr. D.A. Balaji, Dear Sir, We thank you for kind enquiry about our servo stabilisers, and we would like to quote for the same follows:
Sl. No
Model
Qty
Rate
Amount
BCS Un-Balanced Type Air Cooled 3 Servo stabiliser Model Input Voltage Out Put Voltage : BCS 30 Kva : 175V to 265V 1 : 220 Volts 1 2%
2 Nos
56,900.00
1,13,800.00
We hope the above quoted prices are in line with your requirements and now we look forward for the pleasure of receiving your valuable order at the earliest. Thanking you and assuring you of our best attention at all times. Yours sincerely, M Nagarajan
Features of BCS Servo Stabilizer:Protections: Low Voltage Protection through Contactor at Out put High Voltage Protection through Contactor at Out put Over load Protection through MCB at Input Short Circuit Protection through MCB / MCCB at input Single Phase preventer through Contactor at Output On load by pass provision at Input
High Reliability We always use solid state control circuits, No relays, No warm up time, Synchronous motor drive, and Professional grade ICs and components are used Trouble Free Operation Every unit is soak tested for 48 hours Quick response time 10 Millie Sec ( Half a Cycle) All transformers are with the state of the art design wounded on CR laminations and double vacuum impregnated for high efficiency Excellent regulation as high as 0.5% Zero wave-form distortion Plug-in type fiberglass PCBs with gold-plated fingers for better contacts to ensure excellent reliability and minimum down-time Unaffected by load power factor No Load losses are very low Very wide input operating ranges Reset Manual / Auto reset with time delay (Optional) Control Switch Phase control- Individual phase control is provided for Meter Provision of cabling : Input / Output cable termination with provision for fixing cable glands Servo Motor Drive : Rugged AC step synchronous motor Enclosure IP 32 Mounting - floor mounted / Free on wheel
TECHNICAL SPECIFICATIONS FOR BCS SCVS AIR COOLED Input Voltage Out Put Voltage Line Frequency Output Voltage Regulation : : : : 300V to 460V Phase To Phase 415V 1% Phase To Phase 50 Hz 2% 1%
Type conditions Efficiency Speed of Correction Wave form distortion Effect of Load power factor Ambient Temperature Duty Cycle Mode of System Indications on
: : : : : : : : :
Unbalanced supply and Load >90 % 60 V per sec. Nil Nil 0-40C Continuous Fully Automatic / Manual Input on Output On Output Cutoff Auto/Manual Selector Switch Increase/Decrease Selector Switch Volts adjustable potentiometer (Optl) Voltmeter to read Input and Output Voltages with selector switch.
Metering
Panel Control
Auto / Manual select switch (optional) Increase / Decrease switch to control the output voltage in manual mode (optional) Volts adjust to set required output in auto mode (optional) Without Single phase preventer Contactors will be provided at output side