Sunteți pe pagina 1din 6

60 Series - General purpose relays 6 - 10 A Features

Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations) Contact material options Lockable test button with mechanical flag indicator (preferred version) 90 series sockets Coil EMC suppression Timer accessories 86 series

60.12

60.13

2 pole, 10 A power contacts 8 pin plug-in

3 pole, 10 A power contacts 11 pin plug-in

FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Contact configuration Rated current/Maximum peak current Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load Standard contact material Coil specification Nominal voltage (UN) Rated power AC/DC Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC Electrical life at rated load AC1 Operate/release time cycles cycles ms 20 106/50 106 200 10 9/9 4 1,000 40+70 RT I
3

2 CO (DPDT) A VA VA kW A 10/20 250/400 2,500 500 0.37 10/0.4/0.15 500 (10/5) AgNi V AC (50/60 Hz) V DC VA (50 Hz)/W AC DC AC/DC AC/DC 2.2/1.3 (0.81.1)UN (0.81.1)UN 0.8 UN/0.5 UN 0.2 UN/0.1 UN

3 CO (3PDT) 10/20 250/400 2,500 500 0.37 10/0.4/0.15 500 (10/5) AgNi

Rated voltage/Maximum switching voltage V AC

mW (V/mA)

6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 2.2/1.3 (0.81.1)UN (0.81.1)UN 0.8 UN/0.5 UN 0.2 UN/0.1 UN 20 106/50 106 200 103 9/9 3.6 1,000 40+70 RT I

Insulation between coil and contacts (1.2/50 s) kV Dielectric strength between open contacts V AC Ambient temperature range Environmental protection Approvals (according to type) C

60 Series - General purpose relays 6 - 10 A Features


Plug-in mount - 6 A Bifurcated contacts for low level switching 2 & 3 pole changeover contacts Cadmium Free contacts (Gold plated Silver Nickel) AC coils & DC coils Lockable test button with mechanical flag indicator (preferred version) 90 series sockets Coil EMC suppression Timer accessories 86 series

60.12 - 5200

60.13 - 5200

2 pole, 6 A bifurcated contacts 8 pin plug-in

3 pole, 6 A bifurcated contacts 11 pin plug-in

FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Contact configuration Rated current/Maximum peak current Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load Standard contact material Coil specification Nominal voltage (UN) Rated power AC/DC Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC Electrical life at rated load AC1 Operate/release time Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type)
2

2 CO (DPDT) A VA VA kW A 6/10 250/400 1,500 250 0.185 6/0.3/0.12 50 (5/5) AgNi + Au (5 m) bifurcated contacts V AC (50/60 Hz) V DC VA (50 Hz)/W AC DC AC/DC AC/DC cycles cycles ms V AC C 2.2/1.3 (0.81.1)UN (0.81.1)UN 0.8 UN/0.5 UN 0.2 UN/0.1 UN 20 106/50 106 250 103 9/9 4 1,000 40+70 RT I

3 CO (3PDT) 6/10 250/400 1,500 250 0.185 6/0.3/0.12 50 (5/5) AgNi + Au (5 m) bifurcated contacts

Rated voltage/Maximum switching voltage V AC

mW (V/mA)

6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 2.2/1.3 (0.81.1)UN (0.81.1)UN 0.8 UN/0.5 UN 0.2 UN/0.1 UN 20 106/50 106 250 103 9/9 3.6 1,000 40+70 RT I

Insulation between coil and contacts (1.2/50 s) kV

60 Series - General purpose relays 6 - 10 A Features


Flange mount - General purpose relay 10 A Faston 187, 4.8x0.8 mm 2 & 3 pole changeover contacts AC coils & DC coils Cadmium Free contacts (preferred version) Contacts material options

60.62

60.63

2 pole, 10 A power contacts Flange mount/Faston 187

3 pole, 10 A power contacts Flange mount/Faston 187

FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Contact configuration Rated current/Maximum peak current Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load Standard contact material Coil specification Nominal voltage (UN) Rated power AC/DC Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC Electrical life at rated load AC1 Operate/release time Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type)
3

2 CO (DPDT) A VA VA kW A 10/20 250/400 2,500 500 0.37 10/0.4/0.15 500 (10/5) AgNi V AC (50/60 Hz) V DC VA (50 Hz)/W AC DC AC/DC AC/DC cycles cycles ms V AC C 2.2/1.3 (0.81.1)UN (0.81.1)UN 0.8 UN/0.5 UN 0.2 UN/0.1 UN 20 106/50 106 200 10 9/9 4 1,000 40+70 RT I
3

3 CO (3PDT) 10/20 250/400 2,500 500 0.37 10/0.4/0.15 500 (10/5) AgNi

Rated voltage/Maximum switching voltage V AC

mW (V/mA)

6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 2.2/1.3 (0.81.1)UN (0.81.1)UN 0.8 UN/0.5 UN 0.2 UN/0.1 UN 20 106/50 106 200 103 9/9 3.6 1,000 40+70 RT I

Insulation between coil and contacts (1.2/50 s) kV

60 Series - General purpose relays 6 - 10 A


Ordering information
Example: 60 series plug-in relay, 3 CO (3PDT), 12 V DC coil, test button and mechanical indicator. A B C D

6 0 . 1
Series Type 1 = 8/11 pin plug-in 6 = Faston 187 (4.8x0.8 mm) with flange mount No. of poles 2 = 2 pole 3 = 3 pole

3 . 9 . 0 1 2 . 0

0
D: Special versions 0 = Standard C: Options 0 = None 2 = Mechanical indicator 3 = LED (AC) 4 = Lockable test button + mechanical indicator 5* = Lockable test button + LED (AC) 54* = Lockable test button + LED (AC) + mechanical indicator 6* = LED + diode (DC, polarity positive to pin 2) 7* = Lockable test button + LED + diode (DC, polarity positive to pin 2) 74* = Lockable test button + LED + diode (DC, polarity positive to pin 2) + mechanical indicator * Options not available for 220 V DC and 400 V AC versions.

A: Contact material 0 = Standard 2 = AgCdO 5 = AgNi + Au (5 m) B: Contact circuit 0 = CO (nPDT) 2 = Bifurcated contacts 60.12/13 - 6 A only

Coil version 4 = Current sensing (60.12/13 only) 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications

Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version 60.12/13 AC AC AC AC DC DC DC DC current sensing 60.62/63 AC-DC A 0-2 0-2 5 5 0-2 0-2 5 5 0 0-2-5 B 0 0 000 0 000 0 C 0-2-3-4-5 54 0-2-3-4-5 54 0-2-4-6-7 74 0-2-4-6-7 74 4 0 D 0 / 0 / 0 / 0 / 0 0

2 2

2 2

Descriptions: Options and Special versions

C: Option 3, 5, 54 LED (AC)

C: Option 6, 7, 74 LED + diode (DC, polarity positive to pin 2)

Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074) 1 3
The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive.

60 Series - General purpose relays 6 - 10 A


Technical data
Insulation according to EN 61810-1 Nominal voltage of supply system V AC Rated insulation voltage V AC Pollution degree Insulation between coil and contact set Type of insulation Overvoltage category Rated impulse voltage kV (1.2/50 s) Dielectric strength V AC Insulation between adjacent contacts Type of insulation Overvoltage category Rated impulse voltage kV (1.2/50 s) Dielectric strength V AC Insulation between open contacts Type of disconnection Dielectric strength V AC/kV (1.2/50 s) Conducted disturbance immunity Burst (5...50)ns, 5 kHz, on A1 - A2 Surge (1.2/50 s) on A1 - A2 (differential mode) Other data Bounce time: NO/NC ms Vibration resistance (555)Hz: NO/NC g Shock resistance g Power lost to the environment without contact current W with rated current W 2 pole 230/400 250 3 Basic III 4 2,000 Basic III 4 2,000 Micro-disconnection 1,000/1.5 EN 61000-4-4 EN 61000-4-5 2/4 22/22 20 1.3 2.7 (60.12, 60.62) 400 2 230/400 250 3 Basic III 3.6 2,000 Basic III 3.6 2,000 Micro-disconnection 1,000/1.5 level 4 (4 kV) level 4 (4 kV) 3 pole 400 2

1.3 3.4 (60.13, 60.63)

Contact specification
F 60 - Electrical life (AC) v contact current H 60 - Maximum DC1 breaking capacity

Resistive load - cos = 1 Inductive load - cos = 0.4

DC breaking current (A)

contacts in series

Cycles

DC voltage (V)

When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100103 can be expected. In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.

Coil specifications
DC coil data Nominal voltage UN V 6 12 24 48 60 110 125 220 Coil code Operating range Umin V 4.8 9.6 19.2 38.4 48 88 100 176 Umax V 6.6 13.2 26.4 52.8 66 121 138 242 Resistance Rated coil consumption R I at UN mA 28 214 110 109 445 53.9 1,770 27.1 2,760 21.7 9,420 11.7 12,000 10.4 37,300 5.8

AC coil data Nominal voltage UN V 6 12 24 48 60 110 120 230 240 400 Coil code Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 320 Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 440 Resistance Rated coil consumption R I at UN (50Hz) mA 4.6 367 19 183 74 90 290 47 450 37 1,600 20 1,940 18.6 7,250 10.5 8,500 9.2 19,800 6
5

9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220

8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 8.400

60 Series - General purpose relays 6 - 10 A


Coil specifications
R 60 - DC coil operating range v ambient temperature R 60 - AC coil operating range v ambient temperature

1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.

1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.

Current sensing version


Current sensing DC coil data L Coil code 4202 4182 4162 4142 4122 4102 4092 4062 4032 4012 Imin (A) 1.7 1.5 1.4 1.2 1.0 0.85 0.8 0.5 0.25 0.085 IN (A) 2.0 1.8 1.6 1.4 1.2 1.0 0.9 0.6 0.3 0.1 Imax (A) 2.4 2.2 1.9 1.7 1.4 1.2 1.1 0.7 0.4 0.15 R () 0.15 0.19 0.24 0.31 0.42 0.61 0.75 1.70 6.70 61

N Typical application with current sensing relays. An open circuit filiment of lamp L1 is detected by the current sensing relay coil (K1) which causes the back-up safety lamp L2 to be energised, and indication of failure at the control panel via lamp S1. Example: navigation light. L1 = Light L2 = Safety light S1 = Control light K1 = Relay

Current sensing AC coil data Coil code 4251 4181 4161 4121 4101 4051 4041 4031 4021 4011 Imin (A) 2.1 1.5 1.4 1.0 0.85 0.42 0.34 0.25 0.17 0.085 IN (A) 2.5 1.8 1.6 1.2 1.0 0.5 0.4 0.3 0.2 0.1 Imax (A) 3.0 2.2 1.9 1.4 1.2 0.6 0.5 0.4 0.25 0.15 R () 0.05 0.10 0.12 0.22 0.32 1.28 2.00 3.57 8.0 32.1

Other types of current sensing relays are available on request.

Accessories
Sheet of marker tags for relay types 60.12 and 60.13, plastic, 72 tags, 6x12 mm 060.72

060.72 6

S-ar putea să vă placă și