PV Plant REPORT Location

CONTINENT Europe COUNTRY Romania LOCATION Bucharest Inverter Model TRIO-20.0-TL-OUTD Rated AC Power [kW]/ Rated AC Voltage [V] 20000 / 400 Mppt Configuration PARALLEL MPPT (Num. MPPT ind.: 1) Total number of PV modules 90 Installed DC Power (STC) [kW] 20700 Notes

Temperature (C) Amb


Minimum Average Maximum -4C 25C 26C

Cell
-4C 60C 61C

Mounting method
Flush on roof

PV Panel (manufacturer / model) Siliken / Atakama-P60S 230 Tecnology STC Rated Power [W] 230 Open Circuit Voltage - Voc [V] 36.6 Short Circuit Current - Isc [A] 8.64 Maximum Power Voltage - Vmp [V] 28.96 Maximum Power Current - Imp [A] 8.04 Temperature Coefficient - Voc [V/C] -0.13 Temperature Coefficient - Isc [mA/C] 4.98

MPPT1
PV Panels/String Number of Parallel Strings Total number of PV modules Notes Installed DC Power (STC) [kW] Maximum Power/MPPT [kW] Load Factor/MPPT [%] PV Panel Max System Voltage [Vdc] Inverter Maximum Input Voltage [Vdc] String Open Circuit Voltage @-4C [Vdc] String Open Circuit Voltage @61C [Vdc] Inverter Activation Voltage (default) [Vdc] Inverter Reccomended Activation Voltage [Vdc] String Max Power Voltage @-4C [Vdc] String Max Power Voltage @60C [Vdc] String Max Power Voltage @61C [Vdc] Inverter MPP Operating Range* [Vdc] PV Array Max Short Circuit Curr. @61C [Adc] Inverter Max Short Circuit Current/MPPT [Adc] PV Array MPP Current @61C [Adc] Inverter Max MPPT Input Current [Adc] 20.7 22.5 92% 1000 1000 726.7 574.6 360 Default (360) 575 456.4 454.5 252 - 800 44.1 60 41.1 50 18 5 90

MPPT2
n/a n/a n/a
n/a

MPPT3
n/a n/a n/a
n/a

MPPT4
n/a n/a n/a
n/a

MPPT5
n/a n/a n/a
n/a

MPPT6
n/a n/a n/a
n/a

n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a

n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a

n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a

n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a

n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a

Note Explain *) Range for MPPT operation considering the voltage default activation

Terms and Conditions of Use: By using this design tool you are agreeing that it is for estimating the string configurations that can be used with the PowerOne Aurora inverters only. PowerOne makes no claim as to its accuracy in predicting actual performance of your PV system or the inverter or its compliance with codes and standards in force at your project location. All configurations should be double-checked by a qualified engineer for compliance with the inverter operating parameters, and electrical codes and regulations in effect at the installation site. By using this tool, the user indemnifies PowerOne inc. from any and all consequential damages arising from its use.