SERVICE ADJUSTMENTS
1. Adjustment method after PWB and/or IC replacement due to repair
The unit is set to the optimum at the time of shipment from the factory. If any value should become improper or any adjustment is necessary due to the part replacement, make an adjustment according to the following procedure. 1.1. Procure the following units in order to replace the main unit: MAIN UNIT DUNTKF261FMxx NOTE: [Caution when replacing ICs in the main unit (IC1901, IC1902, IC1006 and IC1007)]
Before replacing the relevant part, procure the following parts in which the data have been rewritten.
Description HDMI EDID 1 HDMI EDID 2 HDCP USER SETTINGS FLASH MEMORY
Description new IC code for service VHIM24C02W61EY AND DATA LC32DH500E_HDMI_1_EDID VHIM24C02W61EY AND DATA LC32DH500E_HDMI_2_EDID RH-IXC986WJZZY AND DATA LC32DH500E_HDCP_KEY RH-IXC870WJZZY AND LC32DH500E_MERGE_V1.23
2. Entering and exiting the adjustment process mode. Standard method. 1. By key-unit.
1. Unplug the AC power cord. 2. Press and hold V- and b keys, simultaneously, and then plug the AC power cord. 3. K appears on the screen. 4. Press and hold V- and P- keys, simultaneously. 5. SHARP FACTORY MENU appears (see Figure 1). 6. Unplug the AC power cord to exit of adjustments process.
2. By own R/C
1. Turn on the TV set. 2. Press b,2,5, 8, 0 (the time is limited to 5 sec. approx., for enter this code). 3. SHARP FACTORY MENU appears (see Figure 1). 4. Press OK on lines 5 ~ 12 to go to submenu. 5. Press MENU to return to main menu. 6. Press END to exit of adjustments mode.
16
LC-32DH500
3. Remote control key operation and description of display in adjustment process mode.
1. key operation Remote control key Cursor (/ ) OK Cursor (/) MENU Keyboard unit P (s/r) b V (+/-) MENU Function Moving an item (line) by one (up/down) on Sharp Factory Menu or submenus. Selecting a submenu on lines 5 to 12 of Sharp Factory Menu or executing a function. Changing a selected item setting value. Return to Sharp Factory Menu from a submenu.
The required input mode should be switched previously to enter the Service Mode. CAUTION: Use due care in handling the information described here lest the users should know how to enter the adjustment process mode. If the settings are tampered with in this mode, unrecoverable system damage may result.
4. Description of display
Figure 1: Main Service Adjustment Menu
(1)
Main version Boot loader version Normal standby cause Error standby cause INIT ADJUST ETC PUBLIC MODE SMARTLOADER ADC ADJUST GAMMA SYSTEM INFORMATION
S 1 23 SEES 41 S 63 08 SHARP v1.23 S S v41 MSTAR C 163 08 CL163508 BD_MST064E_C01A 2 Remote control None
Informative (Main microprocessor version). Informative. Informative (Remote Control/Keyboard). Informative (None/Lamp Error). Press OK to go to INIT submenu. Press OK to go to ADJUST submenu. Press OK to go to ETC submenu. Press OK to go to PUBLIC MODE submenu. Press OK to go to SMARTLOADER submenu. Press OK to go to ADC ADJUST submenu. Press OK to go to GAMMA submenu. Press OK to go to SYSTEM INFORMATION submenu.
(2) No. (1) (2) (3) Description Service Information Item name Factory init and Inch setting
(3)
Display specication Current Software version and others. Submenus to be checked or adjusted (by pressing OK button) Are shown on INIT submenu
17
LC-32DH500
INIT Factory Init Inch setting Center acutime RESET EURO SH32_LK315T3LA57 12H 0M Press or to reset (OK will be displayed). Informative (EURO/RUSSIA/SWEDEN/UK/EAST EUROPE) Panel type.
QMAP ADJUST INPUT SOURCE AFEC Comb SECAM SCinit CSC CSC_Dither YCdelay PreFilter HSD_Y HSD_C VSD CTI and Enter key to show/hide OSD. OFF OFF OFF OFF ALLPASS1X ALLPASS1X OFF CTI_1 Only for Engineering purpose (Please dont use) DTV_576p_MPEG2 DTV/RF/MULTIMEDIA
ETC
EEP Clear EEP Clear B Standby cause reset Auto installation SW Pattern L Error Reset L Error Check I2C OFF Sharp protocol Off 0 0 On Off On
Clear NVM data. Clear NVM data (except adjustments area). Reset of STANDBY CAUSE. On: Pending to execute on next power on. Off: Not required. Selection of internal pattern from 0 up to 6 LAMP ERR RESET Initialization of L_ERR. L_ERR detection. 0: activated. 1: deactivated. I2C BUS status. On: free BUS. Off: Normal. Remote Control Protocol. On: SHARP Off: MSTAR. 0: off. 1: White 100%. 2: White 50%. 3: Red 100% 4: Green 100%. 5: Blue 100%. 6: Black 0%.
18
LC-32DH500
PUBLIC MODE Power On xed Maximum volume Volume xed Volume xed level RC button Panel button Menu button On screen display Input mode start Input mode xed RC path through Hotel mode Respond Respond On Normal Variable Off Off Variable 60 Variable 20 Respond Press or to change Variable/Fixed. Press or to change 0/60. Press or to change Variable/Fixed. Press or to change 0/60. Press or to change Respond/No respond. Press or to change Respond/No respond. Press or to change Respond/No respond. Press or to change On/Off. Press or to change Normal/TV/SCART1/ Press or to change Variable/Fixed. Press or to change On/Off (required external module). Press or to change On/Off. SCART2/COMP/HDMI1/HDMI2/AV/MEDIA PLAYER.
PUBLIC MODE Reset Execute Press or to return to factory settings. Press or to confirm (OK will be displayed).
SMARTLOADER Save settings to USB Load settings from USB Press or to Save. (OK or NO USB drive available, please check and/or insert USB dri will be displayed). Press or to Load. (OK, reboot TV set or NO USB drive available, please check and/or insert USB dri will be displayed).
19
LC-32DH500
ADC ADJUST MODE ADJUST R-GAIN G-GAIN B-GAIN R-OFFSET G-OFFSET B-OFFSET AUTO ADC RGB Internal signal 115 109 113 148 116 134 Press or to change RGB/YPbPr(SD)/ YPbPr(HD). Press or to change Internal signal/External signal. Note: External: factory. Internal: service.
GAMMA MGAMMA IN1 MGAMMA IN2 MGAMMA IN3 MGAMMA IN4 MGAMMA IN5 MGAMMA IN6 MGAMMA WRITE MGAMMA RESET Press Page Up/Page Down key to jump to next/previous page. 40 80 120 160 200 240 W/B adjustment, gradation 1 input setting. W/B adjustment, gradation 2 input setting. W/B adjustment, gradation 3 input setting. W/B adjustment, gradation 4 input setting. W/B adjustment, gradation 5 input setting. W/B adjustment, gradation 6 input setting. EEP writing of adjustment values. Initialization of adjustment values.
GAMMA MGAMMA R1 MGAMMA G1 MGAMMA B1 MGAMMA R2 MGAMMA G2 MGAMMA B2 MGAMMA R3 MGAMMA G3 MGAMMA B3 MGAMMA WRITE Press Page Up/Page Down key to jump to next/previous page. 164 169 191 319 327 366 458 474 524 W/B adjustment, gradation 1R adjustment value. W/B adjustment, gradation 1G adjustment value. W/B adjustment, gradation 1B adjustment value. W/B adjustment, gradation 2R adjustment value. W/B adjustment, gradation 2G adjustment value. W/B adjustment, gradation 2B adjustment value. W/B adjustment, gradation 3R adjustment value. W/B adjustment, gradation 3G adjustment value. W/B adjustment, gradation 3R adjustment value. EEP writing of adjustment values.
20
LC-32DH500
GAMMA MGAMMA R4 MGAMMA G4 MGAMMA B4 MGAMMA R5 MGAMMA G5 MGAMMA B5 MGAMMA R6 MGAMMA G6 MGAMMA B6 MGAMMA WRITE Press Page Up/Page Down key to jump to next/previous page. 607 627 697 762 770 857 900 895 1008 W/B adjustment, gradation 4R adjustment value. W/B adjustment, gradation 4G adjustment value. W/B adjustment, gradation 4B adjustment value. W/B adjustment, gradation 5R adjustment value. W/B adjustment, gradation 5G adjustment value. W/B adjustment, gradation 5B adjustment value. W/B adjustment, gradation 6R adjustment value. W/B adjustment, gradation 6G adjustment value. W/B adjustment, gradation 6R adjustment value. EEP writing of adjustment values.
SYSTEM INFORMATION NOISE LEVEL GLOBAL MOTION BIT RATE Scan name search VPS code 830/1 code 830/2 code Top txt enabled 13722 1511 32688 2 FFFF FFFF FFFF 1 Informative (changing). Informative (changing). Informative. Changeable between 0 and 255. Informative. Informative. Informative. Press or to change 0/1. Only for Engineering purpose (Please dont use)
21
LC-32DH500
6.2. COMPONENTS ADC 1. Enter in Service mode. 2. Press until selecting ADC ADJUST option. 3. Press OK. 4. ADC ADJUST menu appears. Fig. 7. 5. Press until selecting ADJUST option. 6. Press until selecting Internal Signal. 7. Press until selecting MODE option. 8. Press until selecting YPbPr(SD). 9. Press until selecting AUTO ADC option. 10. Press , the adjustment starts. 11. SUCCESS appears when the adjustments nish. Note: both SD and HD are adjusted. 12. Exit of Service mode.
22
LC-32DH500
23
LC-32DH500
24
LC-32DH500
2. Countermeasures a. Checking with [L Error Check Off]. Repair the problem that produces the LAMP ERROR. The TV remains with power LED blinking until K mode is forced by local keyboard, in order to disable the LAMP ERROR detection. To disable the LAMP ERROR feature is necessary enter in K mode by pressing VOL DOWN and b keys at same time when the AC cord is plugged in. b. Resetting the LAMP ERROR counter. After the lamp and lamp circuit are found out of trouble, the LAMP ERROR counter should be reset. If a LAMP ERROR is detected ve consecutive times, the power cannot be turned on. Method 1: Using the cursor (UP/DOWN) key, move to the cursor to [L Error Reset] on Line 6 of ETC Menu Fig 4. With the cursor (LEFT/RIGHT) keys reset the value to 0. Method 2: In the case the TV is not blocked (less than 5 consecutive errors), switch on the Set. After 30 minutes working, the LAMP ERROR counter will be reset automatically.
25
LC-32DH500
26
LC-32DH500
27