Documente Academic
Documente Profesional
Documente Cultură
FIRE
ALL
DUAL-FUEL
BURNERS
Dimensions 6514
DIMENSIONS Main air, gas, atomizing air, and oil connections can be rotated relative to one another and to the mounting plate. Drawings show
connections as assembled at the factory. These arrangements reduce maintenance by preventing oil dripping into air or gas manifolds (which
should be above burners) and by minimizing dirt accumulation in pilots and ame supervisory devices. Pilot and main air connections cannot be
aligned in the same direction.
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC.
IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.
Burner wt
designation Q R R
1
S T U V W X Y Z
C
AA
C
BB CC DD
C
lb
6514-6 5316 1038 1916 3716 19
1038 9 4 4 4116
15 58 8
32316 195
6514-7 618 1018 1916 31516 20
1138 878 4 4116 4716 16 58 9 3438 225
6514-8-A 738 11 11316 4516 22
1238 10 6516 478 41516 17 58 121316 411516 335
6514-8-B 1316 8 1238 11316 4516 24
13 1278 8316 61116 5316 19 58 121316 481316 450
6514-9 1516 1338 31316 6316 28
16 13716 11516 8716 6316 23 58 141116 57 795
6514-10 1916 15716 438 51516 32
20 1358 13116 11316 61116 27 1618 631316 1035
Dimensions in inches
Burner
designation A
C
B C D E F G H I J K L
M N P
6514-6 3 2 1 38 1 51732
22 8 18 58 19
2 2
6514-7 4 2 2 38 1 1 5
22 8 19 58 19 1 3
6514-8-A 6 2 2 38 1 1 678
15 12 21 58 19 238 378
6514-8-B 6 3
3
C
38 1 2 738
15 12 22 58 19 5316
C
1916 61316
6514-9 8 4
4
C
1 2 978
15 12 26 58 20 778
C
1916 81316
6514-10 10 6
6
C
1 2 12316
15 12 30 20 878
C
11316 91116
Dimensions in inches and degrees
6514- /LX (refractory tile)
See back for notes and additional information.
S
R
M
S
-6 -7
M
R
S
-10
C
E
C
F
G
C
F
E
G
G
F E
C
B
P
C
D
P
C
C
V
dia.
AA
C
dia.
U-dia.
A-NPT
Main Air Inlet
C
C-NPT
Atomizing Air Inlet
D-NPT
Oil Inlet
L
C
BB
F
A
A
A
G
C
H
A
C
T
45
E-NPT
for Pilot Tip
I-No. of Slots on
J-Bolt Circle for K-Bolts
C
S M
R
N
Z
C CC
DD
W X
-8-A, -8-B, and -9
Y
C
D
B Q B
C
N
M
R
P
D
B
Q
P
C
D
B-NPT
Gas Inlet
TYPICAL SIDE VIEW
C
C
C
2/11 Dims6514
Burner wt Recommended Recommended
designation AA BB CC DD lb Sensitrol oil valve pilot tip
6514-6 16 838 32516 215 1813-02-C 4021-12
6514-7 17 938 34 250 1813-02-D 4025-0-T
6514-8-A 18 121516 42116 370 1813-02-D 4025-0-T
6514-8-B 20 121516 481516 495 1813-02-D 4025-0-T
6514-9 24 1316 1478 571116 860 1813-01 4025-2-T
6514-10 27 1116 16516 631316 1085 1813-01 4025-2-T
6514- /LC,L4,L9 (jacketed tile)
C
A square threaded ange is used for sizes -6, -7, -8. SW style (suitable for slip-on or welded connection) inlet may be ordered as a special
option. An SW inlet is standard for -9 and -10 burners.
C
Opening in furnace shell or outer wall must be " larger than dimension "AA" to allow for mounting plate llet and draft.
C
Blank boss--This may be ordered as a special option with a 1 " tap suitable for 5025-3-1T Oil Pilot, in which case Fives North American will
drill out " web of refractory left in tile before shipment, and the burner nose will be positioned so none of its holes are in front of that opening.
For -10 size, an appropriate 1 " npt half-coupling will be added as a special option.
C
1" fpt for electrode or UV ame detector.
C
Pipe nipple and optional (recommended) Sensitrol Oil Valve are not included as part of the burner assembly, and must be ordered separately.
Dimensions Z and DD assume a 38" close nipple between burner and Sensitrol Oil Valve (6514-6 through -8-B) and a " close nipple between
burner and Sensitrol Valve (6514-9 and -10).