Sunteți pe pagina 1din 25

Supplementary Training Modules on Good Manufacturing Practice Good Practices for Quality Control Laboratories

: Part 3 Working procedures and safety


WHO Technical Report Series, No. 902, 2002. Annex 3

QC

Slide 1 of 25

June 2006

Quality Control
Incoming samples (Sampling plan and procedures)
Sample size sufficient for: the tests to be performed replicate tests retained / retention sample The laboratory must have a sampling plan and internal procedure for sampling, available to all analysts and technicians within the laboratory
Part Three. 14.1 14.3

QC

Slide 2 of 25

June 2006

Quality Control
Test request can be filled out during sampling - accompany each sample submitted to the laboratory, and should contain the following information, e.g.: source of the material full description including its International Nonproprietary Name (INN), concentration or strength, manufacturer, and batch number (if available), size of the sample reason for requesting the analysis date on which the sample was collected
Part Three. 14.5 14.6 (a-f)

QC

Slide 3 of 25

June 2006

Quality Control
Test request can be filled out during sampling accompany each sample submitted to the laboratory, and should contain the following information (continued): size of the consignment from which it was taken, when appropriate expiry date (pharmaceutical product) retest date (starting material, pharmaceutical excipients) pharmacopoeia specifications or other official specifications to be used for testing record of further comments (e.g. discrepancies found) required storage conditions
QC | Slide 4 of 25 June 2006

Part Three. 14.6 (g-k)

Quality Control
Registration and labelling All samples should be assigned a registration number Separate registration numbers different batches A label with appropriate information on each container of the sample

Part Three. 14.7 14.8

QC

Slide 5 of 25

June 2006

Quality Control
Central register
The following information should be recorded: registration number date of receipt specific unit to which the sample was forwarded Sample received should be inspected the findings must be recorded, dated and initialled discrepancies and damage recorded queries referred back to the provider of the sample
Part Three. 14.9 14.10
QC | Slide 6 of 25 June 2006

Quality Control
Storage
The sample prior to testing, the retained sample and any remaining portions of the sample after performance of all required tests must be stored safely (storage conditions) Analysis is determined by the head The sample must be stored until all relevant documentation has been received Request for analysis may be accepted verbally only in case of emergencies Data recorded on the analytical worksheet Copies or duplicates of all documentation must accompany each numbered sample when sent to the specific unit
Part Three. 14.11- 14.17
QC | Slide 7 of 25 June 2006

Quality Control
Analytical worksheet
An internal document in a printed form for recording information Complemented by the raw data obtained in the analysis One used for each numbered sample A further set of analytical worksheets in duplicate can be used for a collaborating unit (after testing, all results are assembled in one analytical worksheet, using the data from all collaborating units).
Part Three. 15.1 15.4

QC

Slide 8 of 25

June 2006

Quality Control
The analytical worksheet must provide or leave space for the following information:
registration number of the sample page numbering including total number of pages (including annexes) date of the test request date of analysis performed name and signature of analyst description of the sample received
Part Three. 15.5
QC | Slide 9 of 25 June 2006

Quality Control
The analytical worksheet must provide or leave space for the following information (continued): reference to the specifications to which the sample was tested including limits (adding any or special methods employed) reference number of the specifications, if available (e.g. pharmacopoeia monograph) results obtained of tested sample the interpretation of the results and the final conclusions, signed by each of the analysts involved and initialled by the supervisor the identity of the test equipment used further comments, e.g. for internal information
QC | Slide 10 of 25 June 2006

Part Three. 15.5 (a-k)

Quality Control
The above information may be complemented by:
detailed notes on the specifications selected and the methods of assessment used whether and when portions of the sample were forwarded to other units for special tests (for example, mass spectrometry, xray diffraction), and the date when the results were received identification number of any reference material if applicable, data to be attached of an instrument verification if applicable, data to be attached of a reagent verification
Part Three. 15.5 (i-v)
QC | Slide 11 of 25 June 2006

Quality Control
The completed analytical worksheet must be signed by the responsible analyst/s and initialled by the supervisor Specifications necessary to assess the sample: Particular pharmacopoeia monograph Manufacturers specifications National pharmacopoeia to be used Specifications contained in the product licence, and should be the current version
Part Three. 15.6-15.8

QC

Slide 12 of 25

June 2006

Quality Control
Filing
Analytical worksheet filed for safe keeping together with any attachments, including calculations and tracings of instrumental analyses If stored in a central archive a copy should be retained in the specific unit for easy reference Analytical test report must be prepared on the basis of the worksheet Mistakes, amended data or text old information may be deleted by a single line (not erased nor made illegible) and the new information added alongside, initialled or signed, and an explanation for the change given
Part Three. 15.9 15.12
QC | Slide 13 of 25 June 2006

Quality Control
Testing
Testing performed according to the work plan If not feasible, the reasons noted, and the sample stored in a special locked-up place Specific tests by a specialized external laboratory responsible person should prepare the request and arrange for the transfer of the required number of units (bottles, vials, tablets) from the sample. Each of these units must bear the correct registration number
Part Three. 16.1. 16.2.

QC

Slide 14 of 25

June 2006

Quality Control
Performing the tests
Official pharmacopoeia requirements see general notices and the specific monographs of the pharmacopoeia System suitability done as relevant All values obtained from each test, including blank results, must immediately be entered on the worksheet, and all graphical data, whether obtained from recording instruments or hand-plotted, must be attached to the analytical worksheet
Part Three. 16.3 16.4.

QC

Slide 15 of 25

June 2006

Quality Control
Evaluation of test results
Results must be reviewed and evaluated do they meet specifications? Consider the results of all tests Doubtful results should be investigated (internal quality system, OOS investigation, etc.) Doubtful results can be rejected only if they are clearly due to error, which has been identified All conclusions entered on the analytical worksheet by the analyst and initialled by the supervisor
Part Three. 17.1 17.2

QC

Slide 16 of 25

June 2006

Quality Control
Analytical test report:

is a compilation of the results and states the conclusion of the examination of a sample issued by the laboratory based on the analytical worksheet

Part Three. 17.3

QC

Slide 17 of 25

June 2006

Quality Control
Analytical test report must provide the following information: registration number name and address of laboratory testing the sample name and address of originator requesting analysis name and description and batch number of the sample, where appropriate reference to the specification(s) used for testing the sample, including limits results of all tests performed, numerical results of all tests performed (if applicable) conclusion whether or not the sample was found to meet the limits of specifications Part Three. 17.4
QC | Slide 18 of 25 June 2006

Quality Control
Analytical test report must provide the following information (continued): date of test performed signature of the head of the laboratory or authorized person name and address of repacker/trader, if applicable name and address of original manufacturer compliance to requirements date received expiry date
QC | Slide 19 of 25 June 2006

Part Three. 17.4

Quality Control
Retained samples The purpose is to have access to the sample material for a specified period See also basic GMP

Part Three. 18

QC

Slide 20 of 25

June 2006

Quality Control

Safety in the laboratory


General aspects to consider. . .

Part Four.

QC

Slide 21 of 25

June 2006

Quality Control
General and specific safety instructions must be:
available to each staff member and supplemented regularly as appropriate (e.g. written material, poster displays, audiovisual material, and occasional seminars)

General rules and SOPs should include:


availability of safety data sheets to staff prior to testing being carried out prohibition of smoking, eating, and drinking in the laboratory familiarity with the use of fire-fighting equipment, including fire extinguishers, fire blankets, and gas masks the use of laboratory coats or other protective clothing including eye protection
Part Four. 19.1 19.2
QC | Slide 22 of 25 June 2006

Quality Control
(continued)

special handling as required, e.g. for highly potent, infectious or volatile substances full labelling of all containers of chemicals, including prominent warnings (e.g. "Poison", "Flammable", "Radiation", etc.) whenever appropriate adequate insulation and spark-proofing of electrical wiring and equipment, including refrigerators observation of safety rules in handling cylinders of compressed gases and familiarity with their colour identification codes awareness of avoiding solitary work in the laboratory provision of first-aid materials and instruction in first-aid techniques, emergency care, and use of antidotes Part Four. 19.2
QC | Slide 23 of 25 June 2006

Quality Control
Protective clothing must be available, including eye protection, masks and gloves Water showers should be installed Rubber suction bulbs used on manual pipettes and siphons Staff must be instructed in the safe handling of glassware, corrosive reagents, and solvents, and particularly in the use of safety containers or baskets to avoid spillage from containers Warnings, precautions and instructions must be given Safe disposal of unwanted corrosive or dangerous products by neutralization or deactivation Safe and complete disposal of mercury and its salts
QC | Slide 24 of 25 June 2006

Part Four. 19.3.

Quality Control
Poisonous or hazardous products Singled out and labelled appropriately Unnecessary contacts with reagents, especially solvents and their vapours, must be avoided The use of known carcinogens and mutagens must be limited or totally excluded if required by local regulations Replacement of toxic solvents and reagents by less toxic materials or reduction of their use
Part Four. 19.4

QC

Slide 25 of 25

June 2006