Sunteți pe pagina 1din 10

Nokia DN2

Dynamic Node
Updated July 2001 Pirkko Kajander

NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DF2-8 DM2 DNT/ILT

DB2

DN2

DYNANET PRODUCTS
DL2E ACM2

ACL2

NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DN2 - Efficient Three-in-one Node for Network Flexibility and Reliability


Efficient capacity grooming and rerouting, because 1) cross-connect, 2) drop/insert and 3) voice/data multiplexer are in the same product. Several efficient ways to protect equipment and/or signal route. Modular design: Capacity can be increased up to 40 ports by 2 port increments. Direct data or speech interfaces upon request. Small size.
3 NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

PABX
D M 2

D M 2

DN2

DN2

DB2 DB2 DB2


D M 2 D M 2

DN2
NMS

PABX

DN 2 Dynamic Node Equipment


2M, G.703 V.11 2M, G.704

Consists of a control unit (CU), a bus power unit (BPU) and interface units (IU2). The BPU- and the IU2-units can be duplicated. Direct data or speech interfaces provided by DYNACARD units. n x 8 kbit/s, n x 64 kbit/s, 2 Mbit/s switching. 1...40 x 2 Mbit/s (G.703/G.704) capacity.

2M, G.704

2M, G.703

VF

V./RS/X

ISDN

CU

BPU

IU2

IU2

CH

NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DN2 - Equipping of a 40-Port Device

Max. 40 unprotected or 20 protected 2M ports. Two 19" subracks. Installation in 19" rack or on the wall.
EBPU IU2 IU2 IU2 IU2 IU2 IU2 IU2 IU2 IU2 IU2 CU

PIA

Unequipped unit slots for any singlecard equipment.


EBPU IU2 IU2 IU2 IU2 IU2 IU2 IU2 IU2 IU2 IU2

PIA

NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DN2 - Connection Alternatives


Cross connection

8...2048 kbit/s
8...2048 kbit/s 32...2048 kbit/s 8...2048 kbit/s 8...2048 kbit/s

Broadcast
Digital omnibus Conditional connections Bit pattern and bit mask connections
6 NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DN2 Redundancy Arrangements



Decentralization of connection information. The cross connection is stored in the Interface Units (IU2) Duplication of 2M connections (1+1 redundancy). A 2Mbit/s signal is brought to/sent from two different ports in the DN2 via two different transmission routes, the DN2 selects the better of these. Duplication of equipment. The bus and the cross-connection can be duplicated if the node size is less than or equal 20 ports. Also the Bus Power Unit can be duplicated. Conditional Connection Tables. The DN2 can be defined to change connection tables on the basis of a condition. This way it is possible to implement e.g.N+1 redundancy. Channel specific redundancy in a loop network. n*8 kbit/s channel protection using a pilot bit.

NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DN2 - Transmission Optimization in a HUB

BTS

BTS

BTS

DN2

BTS

BTS

8 kbit/s channel cross-connection capability. Reduced transmission capacity need (typically -30...-70%). Flexibility for changes and optional selective protection.
8 NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DN 2 - Block Diagram
IU2
DN2 DN2 BUS BUS CU

Plug-In Units
IU2 Interface unit 2x2 Mbit/s CU Control Unit (E)BPU Bus Power Unit

2 Mbit/s

2 Mbit/s . . . 2 Mbit/s IU2

(E)BPU (E)BPU VF-UNIT . . . DATA-UNIT

Optional Units
VF units Data units

2 Mbit/s DYNACARD BUS

NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS

DN 2 - Switching Protection
Decentralized crossconnection. Duplicated connection bus. Incoming signal is fed to both buses. Outgoing signal is selected according to pilot signals of the buses.
2 Mbit/s IU2 DN2 DN2 BUS BUS CU (E)BPU

2 Mbit/s

2 Mbit/s

. . . IU2

(E)BPU

2 Mbit/s

10

NOKIA 2000 DN2_slides_7_01.PPT/ 5.7.2001 / PKS