Documente Academic
Documente Profesional
Documente Cultură
www.huawei.com
Objective
In this course, you will learn the following
contents:
Huawei Confidential
Page 2
Reference
DRX Feature Parameter Description LTE eRAN FDD&TDD 3.0 DRX function design Description
Huawei Confidential
Page 3
DRX Enhancement
Up to 160ms DRX cycle (in sync. Status)
Dynamic DRX
Up to 2.56s DRX cycle (in Unsync. Status) Sync. And Unsync. Status control based on UE history information RRC connection status control Dynamic switch between Sync. DRX And Unsync. DRX
DRX Enhancement:
Relation with preallocation Relation with CQI/SRS Relation with Scheduler SPS/Dynamic Sceduler/SR/ANack Relation with RACH Relation with Handover Relation with measurement (GAP)
eRAN2.0
eRAN2.1
eRAN3.0
eRAN6.0
Next Evolutions
Huawei Confidential
Content
1 2
3 Relation between DRX and others 4 DRX Feature Benefit and influence 5 DRX Feature deployment Configuration and testability
Huawei Confidential
Page 5
Content
1 DRX basic concepts and principles
a) Basic DRX operation
- DRX timers operation - Switching between active time and sleep time - Switching between long cycle and short cycle DRX MAC CE related operation UL data sending during DRX mode DL data receiving during DRX mode
Huawei Confidential
Page 6
DRX cycle
DRX status Active Time In active time, the UE turns on its receiver and monitors the PDCCH Sleep Time In sleep time, the UE turns off its receiver and does not monitor the PDCCH DRX Cycle A DRX cycle specifies the periodic repetition of the On Duration followed by a possible period of inactivity A DRX cycle may be a long (LongDRXCycle) or short cycle (ShortDRXCycle) ; drxStartOffset DRX start offset, the start of OnDurationTimer is decided by DRX Cycle and drxStartOffset DRX timer OnDurationTimer DRXInactivityTimer HARQRTTTimer DRXRetransmissionTimerShortDRXCycleTimer PDCCH SubFrameFor FDD UE operation, this represents any subframe; for TDD, only downlink subframes and subframes including DwPTS
Huawei Confidential Page 7
Timing Stop
Expire
This timer measures the time during which the UE monitors the PDCCH. This timer starts at the first subframe of a DRX cycle. For details, see Note "Startup of a DRX Cycle." Timing is based on the number of consecutive PDCCH subframes. This timer stops after it expires or the UE receives a DRX command MAC control element (MCE). This timer stops. The UE enters the sleep time, no longer monitoring the PDCCH.
Huawei Confidential
Page 8
DRXInactivityTimer
Function
This timer measures the time during which the UE determines whether to extend its active time because of the arrival of new data. This timer provides a reference for the UE to apply a short DRX cycle. This timer starts or restarts when the UE successfully decodes a PDCCH indicating an initial UL grant or downlink (DL) user data for this UE. Timing is based on the number of consecutive PDCCH subframes. This timer stops after it expires or the UE receives the DRX command MCE. After this timer expires, the UE applies a short DRX cycle if the cycle is configured, and the DRX Short Cycle Timer starts or restarts. Alternatively, the UE applies the long DRX cycle if no short DRX cycle is configured.
Start
Huawei Confidential
Page 9
As the PDCCH indicates a DL transmission,start the HARQ RTT timer if a HARQ RTT Timer expires in this subframe and the data in the soft buffer was not successfully decoded,then start the drx-RetransmissionTimer
a new transmission
a retransmission
NACK
ACK
Function
Start
This timer measures the minimum number of subframes before a DL HARQ retransmission arrives in the case of a packet error occurs. This timer is used to determine when to start the DRX Retransmission Timer. This timer starts and the DRX Retransmission Timer stops at the subframe when there may be a possible semi-persistent DL data transmission or stops at the subframe when the UE learns by detecting the PDCCH that one of its HARQ processes has new subframes for DL transmission.
Huawei Confidential
Page 10
Function
Start
This timer measures the minimum number of subframes before a DL HARQ retransmission arrives in the case of a packet error occurs. This timer is used to determine when to start the DRX Retransmission Timer. This timer starts and the DRX Retransmission Timer stops at the subframe when there may be a possible semi-persistent DL data transmission or stops at the subframe when the UE learns by detecting the PDCCH that one of its HARQ processes has new subframes for DL transmission. Timing is based on the number of subframes. This timer stops after it expires. This timer stops. If the UE detects that DL data is received correctly, the UE takes no further action. Otherwise, the DRX Retransmission Timer starts.
This timer measures the time during which the UE waits for HARQ in active time. If this timer expires and the UE has not received the retransmitted data, the UE will not accept it. When the HARQ RTT Timer expires, the DRX Retransmission Timer starts or restarts if the UE does not receive the acknowledgment (ACK) feedback of the corresponding DL data. Timing is based on the number of consecutive PDCCH subframes. This timer stops if the UE receives the retransmission data before the timer expires. This timer stops, and the UE takes no further action.
Huawei Confidential
Page 11
DRX basic concepts and principles - DRX timers operation (5/5) DRXShortCycleTimer
the PDCCH indicates a new transmission Short cycle DRX Short cycle DRX Short cycle DRX UE shall monitor PDCCH Long cycle DRX Long cycle DRX
When the drxShortCycleTimer expires,the UE should enter the long cycle DRX
On Duration timer
This timer measures the lifetime of short DRX cycle, that is, the consecutive repetition times of short DRX cycle. After the DRX Inactivity Timer expires, this timer starts or restarts if a short DRX cycle is configured. After the UE receives the DRX command MCE, this timer starts or restarts if a short DRX cycle is configured.
The UE applies a short DRX cycle after the DRX Short Cycle Timer starts. Timing is based on the repetition times of short DRX cycle. This timer stops after it expires. This timer stops, and the UE applies the long DRX cycle.
Huawei Confidential
Page 12
DRX basic concepts and principles - Switching between active time and sleep time
Switching between active time and sleep time is determined by DRX timers and service processes. Figure shows how the UE receiver in frequency division duplex (FDD) mode switches between active time and sleep time in various scenarios The active time shown in the green (bottom) plot of Figure combines the active time described in each of the other plots excluding the plot of HARQ RTT Timer.
Condition Meaning OD A DRX cycle starts. IA A PDCCH indicating an initial UL or DL data transmission is received. R The HARQ RTT Timer expires. SR A UL scheduling request is sent. UR A UL negative acknowledgment (NACK) is received, and retransmission is required. RAR A non-contention-based random access response is received. CR Msg3 is sent in a random access procedure.
Huawei Confidential
DRX basic concepts and principles - Switching between long cycle and short cycle
Long cycle DRX area
the PDCCH indicates a new transmission UE shall monitor PDCCH Long cycle DRX Short cycle Short cycle DRX DRX
...
7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
...
When the drxShortCycleTimer expires,the UE should enter the long cycle DRX DRX Inactivity timer
On Duration timer
eNodeB can assign both long and short DRX cycles (Option) to the UE, the UE applies only the long or short DRX cycle at a time. If shortDRX-Cycle is configured, the value of longDRX-Cycle shall be a multiple of the shortDRX-Cycle value .The UE can switch between the long and short DRX cycles: - After the DRX Inactivity Timer expires or the UE receives the DRX command MCE from the eNodeB, the UE leaves the long DRX cycle and enters a short DRX cycle; - If the UE does not receive any new data for a period after entering a short DRX cycle, it switches to a long DRX cycle, achieving lower power consumption: The period before the UE switches to a long DRX cycle is called the lifetime of short DRX cycle. The lifetime is measured based on the repetition times of short DRX cycle. The related timer is DRX Short Cycle Timer. The period is specified by the DrxShortCycleTimer parameter. After the DRX Short Cycle Timer expires, the UE applies the long DRX cycle
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14
When the DRX command MAC CE is received,stop on duration timer; stop DRX inactivity timer ;start or restart the drxShortCycleTimer; On Duration timer
When the drxShortCycleTimer expires,the UE should enter the long cycle DRX DRX Inactivity timer DRX Short CycleTimer
If UE received DRX Command MAC CE,then Stop OnDurationTimer Stop DRXInactivityTimer If ShortDRXCycle is configuredthen start or restart DRXShortCycleTimerand enter ShortCycleDRXelse enter LongCycleDRX
Huawei Confidential
Page 15
DRX basic concepts and principles - UL data sending during DRX mode
UE shall monitor PDCCH Long cycle DRX the PDCCH indicates a new UL data transmission
NACK
ACK
In DRX mode, the UE sends an SR when there is data in the UE buffer. If the UE is in sleep time, it immediately switches to active time and begins to monitor the PDCCH ; The eNodeB enables resource scheduling (UL grant )for the UE only in active time; HARQ takes priority over DRX. After a HARQ process starts, the UE immediately switches to active time if it is in sleep time and receives HARQ feedback
Huawei Confidential
Page 16
DRX basic concepts and principles - DL data receiveing during DRX mode
the PDCCH indicates a new DL data transmission the PDCCH indicates a DL data retransmission UE shall monitor PDCCH
As the PDCCH indicates a DL transmission,start the HARQ RTT timer if a HARQ RTT Timer expires in this subframe and the data in the soft buffer was not successfully decoded,then start the drx-RetransmissionTimer
a new transmission
a retransmission
NACK
ACK
The eNodeB enables resource scheduling (DL Assignment )for the UE only in active time HARQ takes priority over DRX. After a HARQ process starts, the UE immediately switches to active time if it is in sleep time and sends HARQ feedback HARQRTTtimerDRXRetransmissionTimer ensuring DL data transfer is not restricted by DRX status. Only when DRXRetransmissionTimer is set too short can cause DL HARQ failure
Huawei Confidential
Page 17
Normal DRX
UE
Normal DRX
If an eNodeB receives a special-DRX starting indication during ANR measurements, the eNodeB configures or reconfigures a relatively large value of the long DRX cycle, during which UEs perform ANR measurements in the sleep time. If the eNodeB receives a special-DRX stopping indication, it restores the configuration.
Huawei Confidential
Page 18
Silence period
Talk spurts
eNodeB DL MAC
Talk spurts
Silence period
DRX
UE UL MAC
UE UL APP
eNodeB UL MAC
SPS sechdule
Dynamic sechdule
Huawei Confidential
Page 19
Content
1 2
3 Relation between DRX and others 4 DRX Feature Benefit and influence 5 DRX Feature deployment Configuration and testability
Huawei Confidential
Page 20
SupportShortDrxSp ecial ShortDrxCycleSpec ial DrxShortCycleTime rSpecial OnDurationTimerS pecial DRXInactivityTimer Special DRXReTxTimer
DRXReTxTimer
DRXReTxTimer
N/A
Huawei Confidential
Page 21
Key Parameters(1)
Id
Recom GUI Value mended Range Value
Parameter Name
MML Command
Meaning
Local cell ID
Indicates the local ID of the cell. It uniquely identifies a cell within a BS.
LocalCellId
0~17
None
Indicates the threshold for UEs to enter DRX in the cell that operates in FDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time intervals (TTIs) with data transmission FddEnterDrxThd to the total TTIs. If the traffic volume at a UE is equal to or lower than this threshold, the eNodeB decides that the UE should retain its DRX state or enter DRX. Indicates the threshold for UEs to exit DRX in the cell that operates in FDD mode. This threshold is used in the DRX algorithm. It is expressed as a proportion of the transmission time intervals (TTIs) with data transmission FddExitDrxThd to the total TTIs. If the traffic volume at a UE is equal to or higher than this threshold, the eNodeB decides that the UE should retain its non-DRX state or exit DRX.
0~999
300
1~1000
800
Indicates the length of the UE traffic measurement period. The traffic volume of a UE during this period is measured. DataAmountStatTi 2~300 mer Based on the measurement result, the DRX algorithm decides whether the UE should enter or exit DRX.
30
HUAWEI Confidential
Page 22
Key Parameters(2)
Parameter Name MML Command Meaning
Id
Recommended Value
Local cell ID
ADD DRXPARAGROUP LST DRXPARAGROUP Indicates the local ID of the cell. It MOD DRXPARAGROUP uniquely identifies a cell within a BS. RMV DRXPARAGROUP
LocalCellI 0~17 d
None
ADD DRXPARAGROUP LST DRXPARAGROUP Indicates the ID of the DRX parameter DrxParaG 0~9 roupId MOD DRXPARAGROUP group. RMV DRXPARAGROUP
None
Indicates whether bearers to which the parameter group applies support DRX. ADD DRXPARAGROUP The value ON indicates that the bearers EnterDrx Enter DRX Switch MOD DRXPARAGROUP support DRX. The value OFF indicates OFF(Off), ON(On) Switch LST DRXPARAGROUP that the bearers do not support DRX. A UE can enter the DRX mode only when all bearers running on it support DRX. PSF1(1 subframe), PSF2(2 subframes), PSF3(3 subframes), PSF4(4 subframes), PSF5(5 Indicates the length of the On Duration subframes), PSF6(6 subframes), Timer. Due to the impact of CQI PSF8(8 subframes), PSF10(10 ADD DRXPARAGROUP OnDuratio subframes), PSF20(20 subframes), reporting intervals and SRS MOD DRXPARAGROUP transmission intervals, the actual value nTimer PSF30(30 subframes), PSF40(40 LST DRXPARAGROUP of this parameter assigned to a UE may subframes), PSF50(50 subframes), be larger than the configured value. PSF60(60 subframes), PSF80(80 subframes), PSF100(100 subframes), PSF200(200 subframes)
QCI 1: ON(On) QCI 2: OFF(Off) QCI 3: OFF(Off) QCI 4: ON(On) QCI 5: OFF(Off) QCI 6: ON(On) QCI 7: OFF(Off) QCI 8: ON(On) QCI 9: ON(On) QCI 1-FDD: PSF10(10 subframes) QCI 4-FDD: PSF2(2 subframes) QCI 6-FDD: PSF2(2 subframes) QCI 8-FDD: PSF2(2 subframes) QCI 9-FDD: PSF2(2 subframes)
On Duration Timer
HUAWEI Confidential
Page 23
Key Parameters(3)
Parameter Name MML Command Meaning
Id
Recommended Value QCI 1-FDD: PSF3(3 subframes) QCI 4-FDD: PSF4(4 subframes) QCI 6-FDD: PSF3(3 subframes) QCI 8-FDD: PSF3(3 subframes) QCI 9-FDD: PSF3(3 subframes)
PSF1(1 subframe), PSF2(2 subframes), PSF3(3 Indicates the length subframes), PSF4(4 subframes), PSF5(5 subframes), of the DRX Inactivity PSF6(6 subframes), PSF8(8 subframes), PSF10(10 Timer. If the value of subframes), PSF20(20 subframes), PSF30(30 this parameter is subframes), PSF40(40 subframes), PSF50(50 DrxInactivit greater than the subframes), PSF60(60 subframes), PSF80(80 corresponding long yTimer subframes), PSF100(100 subframes), PSF200(200 Drx cycle, the subframes), PSF300(300 subframes), PSF500(500 eNodeB does not subframes), PSF750(750 subframes), PSF1280(1280 instruct UEs to enter subframes), PSF1920(1920 subframes), DRX. PSF2560(2560 subframes) Indicates the length of the DRX Retransmission Timer. sf1(1 subframe), sf2(2 subframes), sf4(4 subframes), DrxReTxTi sf6(6 subframes), sf8(8 subframes), sf16(16 mer subframes), sf24(24 subframes), sf33(33 subframes)
ADD DRXPARAGROUP DRX MOD Retransmissi DRXPARAGROUP on Timer LST DRXPARAGROUP ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP ADD DRXPARAGROUP MOD DRXPARAGROUP LST DRXPARAGROUP
QCI 1: sf8(8 subframes) QCI 4: sf8(8 subframes) QCI 6: sf8(8 subframes) QCI 8: sf8(8 subframes) QCI 9: sf8(8 subframes)
SF10(10 subframes), SF20(20 subframes), SF32(32 subframes), SF40(40 subframes), SF64(64 subframes), QCI 1: SF20(20 subframes) SF80(80 subframes), SF128(128 subframes), QCI 4: SF20(20 subframes) Indicates the length LongDrxCy SF160(160 subframes), SF256(256 subframes), QCI 6: SF40(40 subframes) of a long DRX cycle. cle SF320(320 subframes), SF512(512 subframes), QCI 8: SF40(40 subframes) SF640(640 subframes), SF1024(1024 subframes), QCI 9: SF40(40 subframes) SF1280(1280 subframes), SF2048(2048 subframes), SF2560(2560 subframes) Indicates whether SupportSh short DRX cycles are UU_DISABLE(Disable), UU_ENABLE(Enable) ortDrx enabled. QCI 1: UU_DISABLE(Disable) QCI 4: UU_ENABLE(Enable) QCI 6: UU_ENABLE(Enable) QCI 8: UU_ENABLE(Enable) QCI 9: UU_ENABLE(Enable)
HUAWEI Confidential
Page 24
Key Parameters(4)
Parameter Name MML Command Meaning
Id
Recommended Value
SF2(2 subframes), SF5(5 subframes), SF8(8 subframes), SF10(10 subframes), SF16(16 subframes), SF20(20 subframes), SF32(32 subframes), SF40(40 QCI 4: SF5(5 subframes) subframes), SF64(64 subframes), QCI 6: SF5(5 subframes) ShortDrxCycle SF80(80 subframes), SF128(128 QCI 8: SF5(5 subframes) subframes), SF160(160 QCI 9: SF5(5 subframes) subframes), SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes)
ADD DRXPARAGROUP DRX Short MOD Cycle Timer DRXPARAGROUP LST DRXPARAGROUP
Indicates the length of the DRX Short Cycle Timer. If this parameter is set to 1, the length of this timer is one short DRX cycle. If this parameter is set to 2, the length of this timer is two DrxShortCycle 1~16 short DRX cycles. If this parameter is Timer set to a large value, a UE for which short DRX cycles are enabled stays in short-cycle DRX for a long time. For details, see 3GPP TS 36.321 5.7.
DRX switch
OFF(Off)
Indicates whether to enable or ShortDrxSwitc disable short DRX cycles. Short DRX OFF(Off), ON(On) h cycles reduce the traffic delay.
ON(On)
HUAWEI Confidential
Page 25
Key Parameters(5)
Parameter Name MML Command Meaning
Id
Indicates the length of a long DRX cycle that is applied only to non-power-saving UEs whose subscriber profile ID for RAT/frequency priority LongDrxC (RFSP) indexes are contained in the RFSP index ycleSpeci set. Due to the impact of CQI reporting periods al and SRS transmission periods, the actual value of this parameter assigned to a UE may be less than the configured value. Indicates the length of the On Duration Timer that applies only to non-power-saving UEs whose RFSP indexes are contained in the RFSP OnDuratio index set. For details about this timer, see 3GPP nTimerSp TS 36.321. Due to the impact of CQI reporting ecial intervals and SRS transmission intervals, the actual value of this parameter assigned to a UE may be larger than the configured value.
SF10(10 subframes), SF20(20 subframes), SF32(32 subframes), SF40(40 subframes), SF64(64 subframes), SF80(80 subframes), SF128(128 subframes), SF160(160 subframes), SF256(256 subframes), SF10(10 SF320(320 subframes), SF512(512 subframes), subframes) SF640(640 subframes), SF1024(1024 subframes), SF1280(1280 subframes), SF2048(2048 subframes), SF2560(2560 subframes) PSF1(1 subframe), PSF2(2 subframes), PSF3(3 subframes), PSF4(4 subframes), PSF5(5 subframes), PSF6(6 subframes), PSF8(8 subframes), PSF10(10 subframes), PSF20(20 subframes), PSF30(30 PSF4(4 subframes), PSF40(40 subframes), PSF50(50 subframes) subframes), PSF60(60 subframes), PSF80(80 subframes), PSF100(100 subframes), PSF200(200 subframes) PSF1(1 subframe), PSF2(2 subframes), PSF3(3 subframes), PSF4(4 subframes), PSF5(5 subframes), Indicates the length of the DRX Inactivity Timer PSF6(6 subframes), PSF8(8 subframes), PSF10(10 that applies only to non-power-saving UEs subframes), PSF20(20 subframes), PSF30(30 PSF5(5 whose RFSP indexes are contained in the RFSP DrxInactivi subframes), PSF40(40 subframes), PSF50(50 subframes) index set. For details about this timer, see 3GPP tyTimerSp subframes), PSF60(60 subframes), PSF80(80 for FDD ecial TS 36.321. If the value of this parameter is subframes), PSF100(100 subframes), PSF200(200 greater than that of LongDrxCycleSpecial, the subframes), PSF300(300 subframes), PSF500(500 eNodeB does not instruct a UE to enter DRX. subframes), PSF750(750 subframes), PSF1280(1280 subframes), PSF1920(1920 subframes), PSF2560(2560 subframes) Indicates whether to enable or disable short DRX SupportSh cycles for non-power-saving UEs whose RFSP ortDrxSpe UU_DISABLE(Disable), UU_ENABLE(Enable) cial indexes are contained in the RFSP index set. UU_DISABL E(Disable)
HUAWEI Confidential
Page 26
Key Parameters(6)
Parameter Name MML Command Meaning
Id
Long DRX Cycle for ANR Long DRX Cycle for Inter-RAT ANR
SF2(2 subframes), SF5(5 subframes), SF8(8 subframes), SF10(10 subframes), SF16(16 subframes), Indicates the length of a short DRX cycle that ShortDrxC SF20(20 subframes), SF32(32 subframes), SF40(40 applies only to non-power-saving UEs whose SF10(10 ycleSpeci subframes), SF64(64 subframes), SF80(80 subframes), RFSP indexes are contained in the RFSP index subframes) al SF128(128 subframes), SF160(160 subframes), set. SF256(256 subframes), SF320(320 subframes), SF512(512 subframes), SF640(640 subframes) Indicates the length of the DRX Short Cycle Timer that applies only to non-power-saving UEs whose RFSP indexes are contained in the RFSP index set. The length of this timer is expressed in DrxShortC ycleTimer 1~16 the number of short DRX cycles. If this 1 parameter is set to 1, the length of this timer is Special one short DRX cycle. If this parameter is set to 2, the length of this timer is two short DRX cycles. For details, see 3GPP TS 36.321 5.7. SF128(128 subframes), SF160(160 subframes), Indicates the long DRX cycle for intra-RAT ANR. LongDrxC SF256(256 subframes), SF320(320 subframes), If intra-RAT ANR is enabled, this parameter SF320(320 ycleForAn SF512(512 subframes), SF640(640 subframes), takes effect regardless of whether DRX is subframes) r SF1024(1024 subframes), SF1280(1280 subframes), enabled. SF2048(2048 subframes), SF2560(2560 subframes) SF128(128 subframes), SF160(160 subframes), Indicates the long DRX cycle for inter-RAT ANR. LongDRX SF256(256 subframes), SF320(320 subframes), SF1280(128 CycleforIR SF512(512 subframes), SF640(640 subframes), If inter-RAT ANR is enabled, this parameter is 0 subframes) atAnr valid regardless of whether DRX is enabled. SF1024(1024 subframes), SF1280(1280 subframes), SF2048(2048 subframes), SF2560(2560 subframes)
HUAWEI Confidential
Page 27
Content
1 2
3 Relation between DRX and others 4 DRX Feature Benefit and influence 5 DRX Feature deployment Configuration and testability
HUAWEI Confidential
Page 28 Page 28
DRX VS.SRS&CQI
UE shall monitor PDCCH
DRX cycle=40ms
CQI cycle=5ms
DRXCQI DRXCQI
When not in Active Time, CQI/PMI/RI on PUCCH and SRS shall not be reported For UEs complying with 3GPP Release 8, CQIs can be periodically measured and reported in active time in DRX mode. For UEs complying with 3GPP Release 9, CQIs can be reported only in the On Duration. In DRX mode, SRS can be periodically measured and reported only in active time of the UE;
HUAWEI Confidential
Page 29 Page 29
DRX VS.RACH&GAP
RACH take priority than DRX GAP take priority than DRX, even when measurement configurations
HUAWEI Confidential
Page 30 Page 30
The eNodeB enables resource scheduling for the UE only in active time if no system information is delivered or no paging is performed. In DRX mode, the UE sends an SR when there is data in the UE buffer. If the UE is in sleep time, it immediately switches to active time and begins to monitor the PDCCH. Upon reception of a PDCCH message, the DRX Inactivity Timer starts. This ensures that the active time continues and the UE obtains resources. HARQ takes priority over DRX. After a HARQ process starts, the UE immediately switches to active time if it is in sleep time and sends/receives HARQ feedback
HUAWEI Confidential
Page 31 Page 31
DRX vs.HO
In different stages of a handover, DRX functions in the following manners: When the handover process starts: After receiving an indication of accepting the handover decision, the source eNodeB sends the RRC Connection Reconfiguration message to instruct the UE to leave the DRX mode. If the UE is in sleep time, it will receive the message in active time in the next DRX cycle. If the handover succeeds: The UE cannot use the DRX feature if the DRX feature is deactivated on the target eNodeB. If the handover fails: The UE remains in the current cell, and the source eNodeB checks whether the UE can enter the DRX mode.
HUAWEI Confidential
Page 32 Page 32
Content
1 2
3 Relation between DRX and others 4 DRX Feature Benefit and influence 5 DRX Feature deployment Configuration and testability
HUAWEI Confidential
Page 33 Page 33
HUAWEI Confidential
Page 34 Page 34
HUAWEI Confidential
Page 35 Page 35
Content
1 2
3 Relation between DRX and others 4 DRX Feature Benefit and influence 5 DRX Feature deployment Configuration and testability
HUAWEI Confidential
Page 36 Page 36
HUAWEI Confidential
Page 37
HUAWEI Confidential
Page 38
HUAWEI Confidential
Page 39
Testability (1)
If DRX is enabled, the handover performance of UEs in the DRX state can be monitored by checking the counters:
Huawei Confidential
Testability (1)
If DRX is enabled, the handover performance of UEs in the DRX state can be monitored by checking the counters:
Huawei Confidential
Huawei Confidential
Page 42
1. DRX Feature Benefit What kind of DRX timers are mentioned 2. How DRX cycle Switched between long and short 3. When UE is in active time? How DRX status Switched between active time and sleep time 4. How to Sett DRX Parameters for Special UEs 5. How to configure DRX for ANR measurement?
Huawei Confidential
Page 43
Conclusion
DRX is a mechanism for UE power consumptionUE DRX status is control by network between active time and sleep time
DRX cycles are switched between long and short to balance service delay and power saving
Suitable DRX parameters can improve UE stand-by time significant without big influence of service QoS (Objective)
Huawei Confidential
Page 44
Thank You
HUAWEI Confidential
Page 45