Documente Academic
Documente Profesional
Documente Cultură
CROPACK 2010
Migration Testing
Overall migration SML tests Screening methods
DI Michael Pitzl
www.ofi.at
www.ofi.at
Packaging
www.ofi.at
Main Focus:
Certification / Consulting in case of Damage Claims Testing & Quality Assurance Assessment according to the European Food Legislation / LMSVG Clients R&D-Projects Branch-oriented R&D-Projects Branch-oriented Training and Education
...
Migration
www.ofi.at
Mech. Stress
Light
Hygiene H 2O Gas
Migration
Product
Active Packaging
Flavour
Scalping
Potential Migrants
www.ofi.at
Glas - Silicates, heavy metals Plastics - Plasticizers, monomers, antistatics ... Paper - Additives and fillers (chalk etc.) Metal - Aluminium, tin for acid contents
Migration
www.ofi.at
How can be prevented that an illegitimate amount of contents of the packaging migrates into the product?
Choosing the right packaging! Ensured by migration testing - Compliance with overall migration limit (OML) - Specific migration limits (SML) - Maximum legitimate residual content of the substance in the finished food contact material (QMA) !!! Consideration of actual applied conditions (time and temperature combinations)
7
Migration Testing
www.ofi.at
VC in PVC: 78/142/EEC (residual content and transfer to foodstuff) VC-analysis: 80/766/EEC, 81/432/EEC Certain epoxy derivatives: REG (EC) Nr. 1895 / 2005 Plasticizers in gaskets in lids: REG (EC) Nr. 372/2007
8
European Standards
www.ofi.at
Standard EN 1186:
Test methods for overall migration
Standard EN or CEN/TS 13130: Standard methods for the specific migration (SML/QM)
currently, 28 parts are published within this standard
Simulants
www.ofi.at
Aqueous foods pH > 4,5 Distilled water (A) Acidic foods pH 4,5 3 % (w/v) Acetic acid (B) Alcoholic foods: 10 % (v/v) Ethanol (C) milk / milk products: 50 % (v/v) Ethanol Fatty foods: Rectified olive oil (D) Dry foods: none
10
11
www.ofi.at
Migration Testing:
Unknown contact time, application for ambient temperature or lower temperatures:
10 d / 40 C (all simulants)
2 h / 70 C (all simulants)
12
Migration Testing
www.ofi.at
If the use of fatty food simulants is not feasible for technical reasons
Substitution: defined test media and conditions, corresponding to the simulant D Iso-Octan Ethanol (95 %)
13
Migration Testing
www.ofi.at
Consideration of the practical usage conditions of the packaging (e. g. for which foodstuff applied?) Clarification of the usage conditions Selection of the simulant and test conditions (contact time and temperature) Is overall migration limit complied (OML)? Compliance with thresholds of the specific migration (SML) residual content in the commidity (QM)?
14
www.ofi.at
Plastic 2002/72/EC
amanded VO Nr. 975/2009
Ceramik 84/500/EEC
amanded2005/ 31/EC
Analyses of VC 81/432/EEC
Rules Migration
amended 97/48/EEC
List of Simulants
amended 2007/19/EC
82/711/EEC
85/572/EEC
15
EU-Substances List - Based on: 2002/72/EG incl. supplements - Containing an authorised positive list of monomers and an incomplete list of additives
16
SML / QM
www.ofi.at
Test Methods: migration test medium + GC, HPLC Positive List (excerpt):
17
Special Cases:
Calculation model
18
Gas Chromatography
www.ofi.at
19
Chromatographic Separation
www.ofi.at
Separation of substances mixture due to different retention times of each single analyte during the transport through the chromatographic bed
20
Definitions
www.ofi.at
(yes/no). If a sample possessed the exact content of the dicision limit, the analyte wouldnt be detected in 50 % of the measurements despite the presence of the analyte (false negative).
DETECTION LIMIT: minimal concentration of an analyte, which is
detected with a high likeliness (e. g. 95 %). The detection limit is usually twice the amount of the decision limit.
DETERMINATION LIMIT: lowest concentration of an analyte,
which can be quantitatively detected with a determined accuracy. Quantitative analyse results are only declared above the determination limit. The determination limit equals approximately the triple amount of the decision limit.
21
Gas Chromatography
www.ofi.at
Thermodesorber:
22
Screening Methods
www.ofi.at
Migration or directly in food Which peaks are explainable, which are not?
Criticism: Analysis method? Comparability? Undetected
substances?
Abundance
T IC: H U ND 002.D
3.57 140000 130000 120000 110000 100000 90000 80000 70000 60000 50000 3.26 40000 30000 20000 10000 0 3.00 Time--> 4.87 4.74 5.15 5.06 4.18 3.77 3.51
5.96 6.21
8.90
11.15
7.19 7.29
9.78 12.74
4.00
5.00
6.00
7.00
8.00
9.00
10.00
11.00
12.00
23
Regulation 372/2007/EG laying down transitional migration limits for plasticizers in gaskets in lids intended to come into contact with food
SML for: fatty food: 300mg/kg* all others: 60 mg/kg* baby / infant food: 30 mg/kg* (restriction for ESBO)
* of food or food simulant
24
Example - ITX
www.ofi.at
Isopropylthioxanthone (ITX)
25
IVLV cluster commodities Working group of German-speaking testing laboratories eurofins, Fresenius, GALAB, GfU, innoform, ISEGA, MUVA, Nehring, ofi, SQTS Agreement on common test conditions:
Time / Temperature
- at customer - at laboratory: a) guideline value 10 days at 40 C b) alternatively according to actual application
Pressure
- three-dimensional - pile (according to customer) - flat/foil a) roll b) pile - full-surface contact - flexible - 1kg/dm
New simulants
e. g. Tenax:
27
Priority: 1. Specific migration 2. Overall migration Overall migration: Test conditions OM1-9
28
Contacts
www.ofi.at
DI Michael Pitzl
(ext. 597, E-Mail: michael.pitzl@ofi.at)
sterreichisches Forschungsinstitut fr Chemie und Technik (ofi) Brehmstrae 14A 1110 Vienna +43-(0)1-798 16 01 ext. +43-(0)1-798 16 01 - 480
29