OPERATION OF POINTS IN PI.

Features: Operation by route initiation. Operation individually/manually. Mid stroke facility. Separate tail cable to enhance safety in case of accidental damage/shortening of cores.

POINT ORDERING CIRCUIT

B24V (INT)

N24V (INT)

POINT ODERING CIRCUIT. Actuate for both auto route setting and manual operation. Use of magnetically latch relay to act as a memory during power failure case (as the PIs are of push button type). Track locking achieved during ordering of points.

Provision of operation of points during point zone track circuit failure. Prevention of ordering the points when it is engaged with other conflicting routes (may be set or initiated). Crank handle locking incorporated only during auto route setting leaving for manual operation for easy maintenance. Latching/delatching circuit is provided with double cutting features.

POINT TIMER CIRCUIT

B24V (INT)

N24V (INT)

100 OHM 5W

20,000 MFD 50V

POINT TIMER CIRCUIT


Prevents over-rubbing of friction clutch. Ceases the driving feed as soon as point set and locked. Condenser value may be adjusted to 200% of normal operating time of the motor at site. Certain time delay provided between two successive operation.

POINT OPERATION CIRCUIT

B24 (INT)

N24

POINT DRIVING CIRCUIT


Heavy duty biased contactor relays used. Cross protection of contactor relays provided against false feed. Use of separate contactor relay for each end of crossover to prevent self-unlocking. Double cutting features provided for contactor relays.

RELAY ROOM
B110 (POINT)

POINT DETECTION CIRCUIT


LOCATION BOX JB 59B

59B NWPR 59B RWPR

POINT MACHINE 59B

NW

RW
'B'

N110 (POINT)

59B NWPR 59B RWPR

CW N24 (INT)
B24 (EXT)
2A

B110 (POINT)
2A

59A NWPR 59A RWPR

LOCATION BOX
NW

JB 59A

POINT MACHINE 59A

RW
'A'

N110 (POINT)

59A NWPR 59A RWPR 59 RWKR 59 RWKPR 59 NWKR 59 NWKPR

CW

59 NWR 59 NWR 59 RWR 59 RWR


'F' RD 'D' RD 'E' ND 'C' ND ND ND

R1

59

R2

NWKR

R1

59

R2

RWKR
RD RD

POINT OPERATION AND DETECTION CIRCUIT

Protection against picking up of detection relays against cable fault condition. Separate tail cable to prevent unsafe situation during multi-cable fault/damage. Extension of track locking not provided in operating circuit as point may stop in mid position if track circuit fails during operation.

IMPROVEMENT OF POINT CIRCUIT


Suitable for Push Button, Route Setting type Panel. Emergency point operation under Point Zone Track Fail condition introduced. Crank Handle Interlocking introduced in Point Driving Circuit during auto route setting. Separate tail cable used to prevent unwanted situation due to multiple cable fault. Using latch relay ensures the last operated position of the point like point switch.

Economy of relays by introducing the relay NLBPR / RLBPR. Provision of individual point contactor relay for each end prevents the unwanted unlocking of the point during parallel operation of both end. Cross protection of contactor relay provided against false feed. Separate point locking relay provided instead of locking by approach lock relay.

COMMENTS ON CSTE/SECRS LETTER NO. SECR/S&T/DRG./1965 DATED 18.11.2008


This may be possible if contactor relay / contactor group placed in the Track Relay Location Box for Point Zone Track Circuit i.e. for local feeding arrangement. Using contacts of normal Q-Series Relays in the 110 V point driving circuit is not advisable particularly during obstruction. Parallelism of contacts cannot increase the current carrying capacity because failure of any contacts / soldering may create unwanted situation.

Another heavy duty contactor relay is to be used affecting the economy. Extra requirement of cable core for generating repeater of WLR & EWNR at Location Box. Maximum relay wiring involves at Location Box. The total enhancement of safety depends upon the relay named TPZR. The integrity of TPZR relay is nowhere proved in interlocking and hence if it is forcefully picked up, then normal working will not be disturbed but total expenditure / sophistication against the abnormal working of TPR and operation of point under lock condition will become null and void.

Using of one time time-delay for extracting of

no. of keys may not be advisable because this operation is very rare and will be performed under abnormal condition. So, individual timedelay for each crank handle group may be continued. This is not affecting the economy. As per Eastern Railway practice, the cross protection against false feed on the contactor relays will take care. As per Eastern Railway practice, the emergency operation of point is provided.

COMMENTS ON TYPICAL POINT CONTROL CIRCUIT OF SE RLY.


24 Volt Siemens contactor unit used. Cross protection against false feed in 110 V DC circuit provided. Local control feeding for point drive. Crank Handle contact used in Detection Circuit in stead of 110 V circuit. Detection Circuit is Cross protected during operation. Driving Relays (WNPR/WRPR) is not cross protected.

FEATURES OF POINT CONTROL CIRCUIT USED IN E. RLY.

Latch relay (NWR/RWR) used as a substitute of point switch / lever for push button panel. Emergency operation of point under track fail condition provided. Holding time of WJR relay is adjusted to 200% of normal operating time. The contactor relay (NWPR/RWPR) have been provided with active cross protection. Mid stroke facility provided. Separate tail cable used to prevent unwanted situation during multiple cable fault. Contactor relay (NWPR/RWPR) provided with double cutting. NLBPR/RLBPR relay generated to economise the interlocking. Correspondence of latch relay proved in detection circuit. Simultaneous feed to both latch relay is prevented to prevent hunting. Separate contactor relay for each end provided to prevent the unwanted situation created during parallel operation.

PROVISION OF X-PROTECTION IN POINT DRIVE CIRCUIT


RELAY ROOM
59B NWPR 59B RWPR
N110 (POINT)

B110 (POINT)

LOCATION BOX
NW 59B NWPR 59B RWPR 59B RWPR 59B NWPR

JB 59B

POINT MACHINE 59B

RW
'B'

59B NWPR 59B RWPR

CW N24 (INT)
B24 (EXT)
2A

B110 (POINT)
2A

59A NWPR 59A RWPR 59A NWPR 59A RWPR 59A RWPR 59A NWPR

LOCATION BOX
NW

JB 59A

POINT MACHINE 59A

RW
'A'

N110 (POINT)

59A NWPR 59A RWPR 59 RWKR 59 RWKPR 59 NWKR 59 NWKPR

CW

59 NWR 59 NWR 59 RWR 59 RWR


'F' RD 'D' RD 'E' ND 'C' ND ND ND

R1

59

R2

NWKR

R1

59

R2

RWKR
RD RD