Sunteți pe pagina 1din 26

I-CASS Door Access System

THE LEADING INNOVATOR OF SECURITY SYSTEM

Table Of Content

1. 2. 3. 4. 5. 6. 7. 8.

Introduction to I-CASS. Comparison with K-series. System Component. System configuration. System Technology. I-Cass Features. Technical Specification. Precaution & Maintenance.

System Introduction(1)
Max.32 doors access control system. Categorized into 2/4/8/12/16/24/32 doors version. Combination of existing door access system, time attendance system, and alarm monitoring system. T-series K-series FEP : Multi-door interlocking features : Auxiliary Output relay based on defined transaction. : Supervised alarm input points.

System Introduction(2)
Integrated with S-series, K-series, T-series, Commando, Centurion and FEP alarm monitoring system design concept.

Bring in wireless messaging technology. Short message service among very doors. Huge user and transaction storage capacity. High speed processing and respond time. Interactive blue light graphic LCD display Emergency over ride key( Electronic Key). Long reading range for proximity technology. Ready for mifare and wiegand 26/32bits.

System Introduction(3)
1. People choose I-CASS for its flexibility usage in security access control and other relevant application such as:

1. Multi-door anti-pass back that handling max.32 doors


operation. 2. Multi-door interlocking features that only allow one door to grant access at a time. 3. Guard Tour application that enabling patrol guard perform checking duty. 4. Ethernet and GSM ready for internal and external communication. 5. Alarm break in protection. 6. Fire alarm emergency exist.

System Introduction(4)
Dual card entry mode and access counter mode for restricted access area. CCTV and building automation integration. 125Khz and 13.56MHz proximity technology interfacing. I-CASS is designed to meet customer application including Door access control Guard tour patrol Time Attendance Alarm monitoring Car Parking control Building automation Fire alarm panel integration CCTV integration SmartCard based solution

How security handled in I-CASS?


System wiring design Electronic key design Communication data protection Emergency event or alert Low power and main fail power detection Communication break down protection Watch dog for safe guard

Benefit of using I-CASS


To have more card user capacity in the system. To have a high speed and fast processing time for every operation. To have a large door capacity controlled under one controller. To have a alarm monitoring features at every door. To have a guard tour features at every door. To have SMS messaging service among door reader. To have variety choice of operation mode at every door. To have interactive graphic display on every door reader. To have emergency over ride system To have Ethernet ready capability

Comparison with existing controller(1)


Feature/Spec.
Interlocking Anti-pass back Dual card access Access Counter Emergency Key override

K-series
No

I-CASS
5 door per group (100 group)

Available among max. 8 Available among doors Max.32 doors No No Tabular key lock Available (100 match code) Available on every door setting Electronic key with 4 digits password.

Display unit

Normal dot matrix LCD

Graphic LCD with blue backlit

Comparison with existing controller(2)


Features/Spec.
Ethernet
GSM SMS Alarm monitoring Fire alarm

K-series
No
No Based on TTL input on every controller only No

I-CASS
On board Ready
Ready 2 supervised sensor points on every door Fire alarm for emergency door release Available on every door ready as checking terminal. Available

Guard Tour

No

Auxiliary Output

Available

Comparison with existing controller(3)

Feature/Spec.
Speed User storage Transaction storage Door connection Processor RAM

K-series
8Hz 5,000 users 2,500 Max. 8 doors 8 bits MCU 128K Byte

I-CASS
24MHz 20,000 users 50,000 users Max. 32 doors 16 bits MCU 2M byte

Comparison with existing controller(4)


Feature/Spec.
Short Messaging Service Door release time zone Lock out mode Emergency duress alarm General purpose relay output

K-series
No No No Available No

I-CASS
Available among door readers Available on every door setting Available on every door setting Available Available on controller

Software

32bits SmartGuard series software

32bits SmartGuard ICASS software

Level of Changes
19200bps 1024KB 8 6Mhz 32 60% more Existing System I-CASS System

40% 3 2Mhz 128KB 16 9600bps

Bus Onboard UART Frequency RAM Size

Comm. Speed

Over all Door Connection Features

Comparison with Castle-S/K/T&Commando System

System Component(1)
I-CASS controller SmartBox (Door Interface Unit) Door Reader Electronic Key Power Supply PC interface (PCI) SmartGuard I-CASS v5.6 Used as real time processing unit for all door event and alarm. As card user databases storage. As log transactions storage. Used for all the user setting. Responsible for all the communication bus polling.

System Component(2)
SmartBox-Door Interface Unit Used to control the electronic door lock device, door contact and lock release button. Used as reader interface communication gateway to controller. Perform basic door controlling function during system controller breakdown.

System Component(3)
I-CASS Reader Interface Act as reader interface for proximity reader. Mifare serial number interfacing. Wiegand 26bits interfacing. Keypad and LCD interfacing. Perform card number conversion. Display informative message. PIN generator Alarm arming and disarming interface panel

System Component(4)
Electronic Key Connected to reader interface board Used during emergency breakdown to over-ride the door lock. Security key is stored with a standard encryption technique. 10 digits key with suitable password to release door lock.

System Component(5)
PC Interface Unit (PCI) Used as a gateway for controller uplink and PC communication port. Used as a signal converter for RS232 to RS485 communication. Act as a software security key for software version determination.

System Component(6)

SmartGuard ICASS v5.6 32bits PC software. Act as a interface software for data or user setting downloading machine. Act as log transaction uploading software for data reporting purpose. Time attendance report generation.

System Configuration(1)
BUS 4 BUS 3 BUS 2 I-CASS Controller

RS 485 PC I PC Interface

RS 232

I-Cass Software
BUS 1

2 Wires

Maximum 8 doors (expandable)

Door Interface (1)

Door Interface (2)

Door Interface (3)

Door Interface (4)

Door Interface (5)

Push Button

In Reader
E-Key

Lock System

RS 485 RS 232

E-Key

Out Reader

Magnetic Sensor

I-Cass Features
Proximity Technology

ABS Casing

LCD Screen

SMS Press Alarm Guard Tour Alarm Systems Time Attendance

Polycarbonate Keypad

Networking

E - Key

Features Highlighted (1)


Enable Short Message Service (SMS)
Inbound System
SMS

Preset greetings or short messages


Outbound System

Employees

Doors forced open or burglary

SMS

Owner

Storage Capacity: 100 users with 50 characters each user.

Features Highlighted (2)


Guard Tour Feature
1. Configuration
Door 1
Main

Time set : 10 mins

Door 2
Back

Time set : 20 mins

Door 3
Off

2. He/She did not proceed to Door 2


Door 2 Beep
Back

Door 1
Main

Door 3
Time set : 20 mins Off

Time set : 10 mins

3. He/She did not proceed to Door 3 Door 1


Main

Time set : 10 mins

Door 2
Back

Time set : 20 mins

Door 3 Beep
Off

Features Highlighted (3)


Controller storage capacity : Standard 20,000 users. Expandable to 100,000 users Event Transaction Storage Capacity: Maximum 30,000 events Multi door Anti-pass back. Multi door Interlocking On board alarm input and output point. Dual Card Mode.

Features Highlighted (4)


Access Counter. Time Zone Control Door Release Button 2 Holiday Groups @ 50 settings per group. Software Configurable to general purpose relay output. Enable to Interface with CIA88 additional alarm input or output point. Maximum 32 doors linkage per controller.

Keypad arming on every door. Controller backup. Electronic Key (E-Key) for emergency door release. Support K series feature. On board Ethernet. Graphic LCD.

~ The End ~

~ Thank you ~
Visit our website: www.castle.com.my for more information.