ZXSDR B8200 Overview Working Principle Product System Structure Board Function Cable Introduction
B8200
Product Characteristics
200 Mbps DL + 75 Mbps UL (three 20 MHz cells in MIMO 2x2) 600 Mbps DL + 225 Mbps UL(six 20 MHz cells in MIMO 2x2) 600 Mbps DL + 300 Mbps UL(three BPL boards in MIMO 4x4)
GE/FE interfaces and IP networking Star and chain networking MicroTCA platform, 2U in height 19 inches in width
ZXSDR B8200 L200 accomplishes the following basic functions with Uu/S1/X2 and O&M interfaces:
Channel coding and decoding Channel multiplexing and de-multiplexing Baseband resource pooling function Power control Spatial multiplexing, transmit diversity and receive diversity Synchronization Operation and Maintenance
Contents
ZXSDR B8200 Overview Working Principle Product System Structure Board Function Cable Introduction
Contents
ZXSDR B8200 Overview Working Principle Product System Structure Board Function Cable Introduction
Module Structure
Control and clock board: CC Baseband pool board: BPL Power module: PM Site alarm module: SA Fan module: FAN
Hardware Structure
Contents
ZXSDR B8200 Overview Working Principle Product System Structure Board Function Cable Introduction
CC Board Function
ZXSDR B8200 L200 can be configured with maximum 2 CC boards for 1+1 redundancy. There are three main functional modules:
CC Board Interface
CC Board Indicators
LED
RUN ALM MS REF
Color
Green Red Green Green Indicate the alarm.
Meaning
Indicate the running state. Indicate the active/standby state Indicate the GPS antenna state or 2 MHz status. It also shows the connection states of the SMA port on the corresponding panel. Indicate the link states of the ETH0 interface. Indicate the link states ofDEBUG/CAS/LMT interface Indicates E1/T1 link states
ETH0 ETH1
Green Green
E0S~E3S Green
FS Function
FS board is fabric switch board which provide baseband optical interface between eBBU and eRRU, and processes the IQ signal.
FS Board Indicators
LED
RUN ALM
Color
Green Red Indicate the alarm.
Meaning
Indicate the running state.
MS
SCS FLS RLS
Green
Green Green Green
ZXSDR B8200 L200 can be installed with 1 to 3 BPL boards. One BPL can deal with 20MHz LTE bandwidth with 3 cells. BPL processes LTE baseband protocol specified by 3GPP R8.
Processing physical layer protocol. Providing uplink/downlink I/Q signal. Processing MAC, RLC and PDCP protocol.
Color
Green
Meaning
Indicate the running state.
ALM
BLS BSA LNK
Red
Green Green Green
CST
OF0~OF2
Green
Green
SA Board Function
ZXSDR B8200 L200 is configured with 1 Site Alarm (SA) board. The board will be managed by CC board. The main function of SA board are:
Responsible for fan speed control and alarming. Providing external interfaces. RS485/232 interface Monitoring serial interface. Monitoring boards temperature. Providing dry contacts and the lightening protection for the external interfaces.
ZXSDR B8200 L200 is configured with 1 Fan Module(FAN). The main functions of FAN are:
Fan speed auto-adjustment according to the equipment working temperature. Monitor, control and fan state reporting.
PM Board Function
ZXSDR B8200 L200 can be configured with 2 PMs, working with 1+1 redundancy mode, or load-balancing. PM has the following functions:
-48V input
Providing two kinds of DC output voltage: 3.3 V for Management Power (MP) and 12V for Payload Power (PP). Reset all of the other boards in eBBU frame under the control of man-machine commands. Detecting the presence/absence state of all the other boards in eBBU frame. Providing protection of input over-voltage/undervoltage. Providing protection of output over-current and overload power management.
Contents
ZXSDR B8200 Overview Working Principle Product System Structure Board Function Cable Introduction
DC Power Cable
DC power cable is used for connecting ZXSDR B8200 L200 to external power distributed unit.
PE Cable
PE cable is used for connecting ZXSDR B8200 L200 to the grounding network, so as to provide protection and ensure personal safety. PE cable is a 16 yellow-green cable with TNR terminals at both ends.
S1/X2 Cable
S1/X2 cable is used for connecting ZXSDR B8200 L200 to core network, or peer eNodeB, or transport devices.
S1/X2 Ethernet Cable
RF Cable
RF cable is used for connecting ZXSDR B8200 L200 to eRRU. End A is used for connecting to eRRU and end B used for connecting to ZXSDR B8200 L200.
Dry contact cable is used for connecting ZXSDR B8200 L200 to external monitoring device, and thus receive dry contact data from external device or send dry contact data to external device.
GPS Jumper
GPS feeder jumper is used for connecting ZXSDR B8200 L200 to GPS antenna. There are two types of GPS feeder jumper: SMA(M)-N(M) and SMA(M)-SMA(M). SMA(M)-N(M) is used for connecting to the lightning arrester.