Sunteți pe pagina 1din 51

Nemo Outdoor User Training

Nemo User Training Course Contents


Nemo Outdoor_Indoor Basic Installation Hardware Configuration Nemo Outdoor Measurement Configuration Introduction to Graphical User Interface Nemo Outdoor Playback & File Formats

Nemo Outdoor_Indoor Installation Nemo Outdoor_Indoor License Option Basic SW Installation

Copy Protection
Nemo Outdoor uses either software or hardware protection. (Indoor and Outdoor measurement are restricted by dongle options) Various available options are configured with each copy protection module.

Nemo Outdoor/Indoor Installation


Installation:

You need to have local Administrator rights to install Nemo Outdoor


Run the Nemo Outdoor setup.exe file and follow the instructions. Current Nemo Outdoor SW is 4.20.73 Check the latest versions of Nemo software from our web pages at (www.nemotechnologies.com) Valid to users with Technical Support Agreement only.

Install DKU 2 cable driver.


Restart laptop

HARDWARE SETUP

Testing Concept Voice Call


The voice testing environment consists of
Nemo Outdoor compatible test measurement mobiles Laptop/Tablet PC with Nemo Outdoor installed Necessary connecting cables GPS receiver for Outdoor measurement (optional) fast frequency scanner.

Testing Concept PS Data Call


The PS data testing environment consists of Nemo Outdoor Application Server(e.g. FTP server, HTTP server, POP3 server, SMTP server, or WAP server)

Nemo Outdoor Measurement Configuration

Manual / Automated Mode


Nemo Outdoor supports manual and automated mode.

Manual mode is based on the user establishing a data transfer connection or making voice calls.
This mode is useful, when user wants to make a single continuous data transfer session or a voice call to monitor the resource allocation and cell reselection performance. This mode requires the user to control phones with Nemo Outdoor. The user should NOT use the mobile keyboard to establish voice calls or data calls.

Automated mode is based on scripts that establish data transfer connections or voice calls on behalf of the user and can repeat the same or different sessions for a defined period of time. Scripts can be saved and edited. Script files can be, quickly and easily built with the Script Editor.

Introduction to Graphical User Interface


Device Info Configuration: Device Info: ( )view disp parameters ( )define displayed parameters ( )configure notifications ( )control phone ( )configure measurement parameters

Measurement Properties

Measurement properties for Voice Calls, Data calls etc. Need to be defined before the actual measurement

Manual Measurement Configuration Information on this tab should be filled in when doing Manual Measurement. (Press Properties)

Voice Number defines the phone number to which voice calls will be made.
Data Number defines the phone number for data calls, user name and password for service, etc. PDP Context Properties defines used APN for Packet data connection Data Protocol defines whether FTP or UDP is used for data transfer ICMP Ping Properties defines Ping settings, like Ping address and size of Ping data

Manual Measurement Control


Measurement can be done from Mobiles Control Panel or from Measurement menu by selecting the appropriate mobile

Automatic Measurement
Measurements can be automatically repeated by predefined number of times
Voice calls, data calls, attach, PDP activation, FTP, Web browsing, SMS, MMS, launch of external application, Ping sessions, etc. can be included in automatic measurement sequence Add / Modify / Delete / Move up / Move down / Append script / Repeat script value/ New /Open / Save / Save As...

Voice Call Script Configuration


Script Editor/ Add / Voice Call
Voice Call Properties Number defines the number to be called Call Duration determines the time that the call lasts in seconds Call Attempt Timeout value determines the maximum duration of the call attempt. After that, the call attempt is considered to be failed.

PS Script Configuration

Application Testing

Access Point Name defines the APN used User Name/Password etc. Depend on operators settings

PS Script Configuration
Host Name: IP address of the FTP server used. Username: username for the FTP server. Password: password for the FTP server. Passive Mode: Some firewalls may be configured to refuse any incoming connection requests, and in that case the data transfer would fail. With passive mode, the client always opens those new connections so the firewall does not block the connection. Direction: Receive downloading; Send uploading Remote File: File @ FTP Server Local File: File @ Testing laptop

PS Script Configuration
URL: IP address of the test file that will be downloaded. For example, 203.125.58.120/1000kb.htm

Local File: File

@ Testing laptop

Script Configuration
Editing PS Script

Ping Test
The ICMP (Internet Control Message Protocol) Ping functionality allows you to perform ping measurements simultaneously with FTP testing and data transfers

Script Enhancements
Possibility to synchronize scripts repeats between devices for benchmarking measurements. Improved wait function allows waiting for notifications during script measurements. Option to use measurement settings configured for manual testing during script measurements.

Event Trigger Notifications


By clicking the Notifications sheet, you can access the Notifications dialog box

Select the Events that you would like to be notified of and also select whether the notification will be a textual note in the Output window, a sound (.wav file), or a bitmap Own notifications can be created for different situations, like bad quality example below, in Configuration tool

User Defined Event Trigger Configuration I


Static triggers Static triggers are made available in Nemo Outdoor by default and can collect statistics. User configurable event trigger

User Defined Event Trigger Configuration II

Bitmap image Audio Wave Notification

Event Trigger Configuration

Event bitmap displayed in map window

Event bitmap displayed in line graph

(1.) Textual Notification displayed in the Output window

(2.) Sound Notification

Real-time monitoring during measurement

Real-time monitoring during measurement

Introduction to Nemo Outdoor Graphical User Interface

Introduction to Graphical User Interface

Introduction to Graphical User Interface


Script Status window

Output window Status bar

Introduction to Graphical User Interface


Windows: Graphs
Line Graphs allow the user to accurately observe the measurement information. zoom thresholds scale selectable parameters & values selectable layers & values average value presentation displaying events & notifications

Workspace and Hardware Configuration


By saving the workspace, different views can be saved to a .wor file. The following
views are saved to the file: Device Information Window views Grid and Graph views

Color Set and Parameter selected in the Map Window (Map layers must be
saved to MapInfo .gst file) By saving the hardware configuration file, the information related to device(s) is saved to the .hwc file:

All information defined in the Measurement Properties Window

Introduction to Graphical User Interface


Windows: Graphs
Line graph Bar graph

Introduction to Graphical User Interface


Windows: Graphs Scatter plot

Scanning results

Introduction to Graphical User Interface

Windows: Grids

The user can easily select the events, parameters, and statistics to be displayed in the grid table. It is also possible to highlight certain events with color to improve the clarity of the results presented. Double-click on an event to view more information about that particular event.

Introduction to Graphical User Interface


Windows: Grids Parameters Events

Introduction to Graphical User Interface


Windows: Grids

Layer3

Statistics

Decoded Layer3

Introduction to Graphical User Interface

Textual Windows: Grids Statistics Decoded Layer3 Events Parameters Layer3 Table

Graphical Windows: Graphs Scatter plot Line graph Scanning Plots Bar graph

Nemo Indoor & Floor plan


Nemo Indoor supports indoor floor plan in .tab; .bmp; .jpg; .tif formats.

Nemo Indoor & Floor plan


During measurement, markers( ) need to be inserted in order to plot route on floor plan.

Nemo Indoor & Floor plan


Indoor floor plan properties

Nemo Outdoor and MS BTS File

Multiple Real-time Route Coloring

New multi route feature allows users to compare easily measurements from different terminals on the same map or to correlate different parameters from the same terminal.

A line from the test vehicle to the serving and neighboring BTS can be drawn.

Playback in Nemo Outdoor

The Play button starts the playback The Pause button pauses the playback

The Stop button stops the playback


Add Marker Add Textual Note Playback Speed

Files Used by Nemo Outdoor

Files Used by Nemo Outdoor


BTS files .bts, .nbf MAP files MapInfo vector and raster maps Result files .dt1, .dt2, .dt3, .dt4 .fs1, fs1, fsn .ft1, ft2, ftn Workspace files .wor Hardware configuration files .hwc Script files .nsf

Nemo Outdoor Measurement File


With Call mode measurements, *.DT1 file is produced.
With Frequency/Pilot Scan (Separate Scanner) measurements , *.FS file is produced.

Open ASCII non-proprietary file format


Easy to view and use

Nemo Outdoor Measurement File Contents


Field strength results of the serving and neighbouring cells Quality class values Mobile output power level Layer 3, layer 2, RLC/MAC, LLC and RRC messages Geographical coordinates and time Call events and handover events Location update events Channel information Other information

Example of Nemo Outdoor Measurement File header


*** Nemo Outdoor 4.12.22 ff ver 1.72 28.01.2004 : 0.00 : : d:\Nemo Tools\deactivate.nsf : 0.00 : Originate : 4.01.12 : : T260 : 11:47:41 #ID Id tag for simultaneous measurement files #AG External antenna gain (dBi) #BF BTS filename #CF Call list filename #CL External cable loss #CM Call mode #HV Handler version #MF Map filename #MT Mobile type #NN Network name : {342E0B9C-E2B5-495e-97AC-87D2B710A166}

#NT Network type


#PN Test call phone number #SW Device software version #HW Device hardware version GAA 0.000000 0.000000 0 0 0 0 0 11:47:42.827 GAC 0.000000 0.000000 0 0 0 0 0 11:47:42.827 8 LUA 0.000000 0.000000 0 0 0 0 0 11:47:42.827

: GSM 900/GSM 1800


: : af.7f.cb : 4C7

Questions?

THANK YOU!

S-ar putea să vă placă și