Sunteți pe pagina 1din 55

Security Level: INTERNAL

SGSN9810 V900R010C02 Software Installation


ISSUE2.0
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

This course provides SGSN9810 software installation information. It describes how to use the INU4Win tool to install carrier grade platform (CGP) software, and how to use the local maintenance terminal (LMT) to install service processes.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 2

References

INU4Win Usage Guide SGSN9810 Deployment Guide

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 3

Upon completion of this course, you will be able to: Describe the SGSN9810 software structure. Describe the SGSN9810 software installation process.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 4

Chapter 1 Overview of Software Installation

Chapter 2 Preparations for Software


Installation Chapter 3 Process of Software Installation

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 5

Software to Be Installed
LMT: The CGP LMT and SGSN9810 LMT run on the PC, functioning as the

operation and maintenance client. The LMTs interact with the CGP LEM (LMT server) on the OMU to implement functions such as running operation commands, returning reports, tracing messages, displaying alarms, and

measuring performances.
CGP installation media: Suse Linux operating system running on the boards,

Oracle database, and CGP network element package (including CGP application software).
SGSN9810 managed element (ME) package software: service-related process

software running on boards.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 6

Software Installation Process


Prepare for the installation

Check whether the software is installed on the OMU before the SGSN9810 is delivered Use the INU4Win tool to install OMU service processes through the incremental installation method

Use the INU4Win tool to install OMU service processes

Install the OMU server

Install the software of the SGSN9810

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 7

Description of the Installation Process


Step
Prepare for the installation.

Description
Before installing the software, make the following preparations: Check the hardware. Check the IP address of the SMM. Check the dual-inline package (DIP) switches of the SDM. Obtain the software package. Check whether the software is installed on the OMU before the SGSN9810 is delivered. The operations involved in the OMU server installation are as follows: Install the OMU server through the incremental installation method or complete installation method. (You can install the OMU server to one OMU or two OMUs.) Check whether the OMU server is installed successfully. Install the OMU client on the PC. Log in to the OMU. Then, configure the software of the SGSN9810 by running man-machine language (MML) commands.

Install the OMU server.

Install the OMU client. Install the software of the SGSN9810.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 8

Question
What does the running software of a board include?

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 9

Chapter 1 Overview of Software Installation

Chapter 2 Preparations for Software


Installation Chapter 3 Process of Software Installation

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 10

Chapter 2 Preparations for Software Installation


2.1 Connecting Cables 2.2 Checking the DIP Switches of the SDM 2.3 Setting IP Addresses for External Ports on the SMM 2.4 Using the KVM over IP 2.5 Setting the OMU Boot Sequence and RAID Disk 2.6 Installing the CGP LMT and SGSN LMT

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 11

Connecting Cables During Software Installation

Network cable Serial port cable

Network cables to be connected Network cable to be connected if you log in during software to the OMU through theinstallation LMT U S I O M U U S I O M U SMM S S W W I I S S W W U U SMM

PC where the INU4Win tool is installed

Set IP addresses for external ports on the SMM through the serial port. Network cable to be connected if you log in to the OMU through the keyboard, video, and mouse (KVM) over IP

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 12

Chapter 2 Preparations for Software Installation


2.1 Connecting Cables 2.2 Checking the DIP Switches of the SDM 2.3 Setting IP Addresses for External Ports on the SMM 2.4 Using the KVM over IP 2.5 Setting the OMU Boot Sequence and RAID Disk 2.6 Installing the CGP LMT and SGSN LMT
HUAWEI TECHNOLOGIES CO., LTD. HUAWEI Confidential
Page 13

Checking the DIP Switches of the SDM


The SDM provides the DIP switches for you to set subrack numbers. When multiple

subracks are cascaded, a subrack number can uniquely identify a subrack.

Eight switches are available as shown in the preceding figure, and they indicate eight binary

bits (0 or 1) respectively. The 8-bit binary value ranges from 00000000 to 11111111, corresponding to subrack numbers 0 to 255. The leftmost bits are the most significant bits, and the rightmost bits are the least significant bits. In the preceding figure, all the switches are set to 0 (OFF); therefore, the subrack number is 0. To set the subrack number to 1, set switch 8 to 1 (ON); to set the subrack number to 2, set switch 7 to 1 (ON); to set the subrack number to 3, set switches 7 and 8 to 1 (ON); the other subrack numbers are conducted by analog.
HUAWEI TECHNOLOGIES CO., LTD.
Page 14

HUAWEI Confidential

Chapter 2 Preparations for Software Installation


2.1 Connecting Cables 2.2 Checking the DIP Switches of the SDM 2.3 Setting IP Addresses for External Ports on the SMM 2.4 Using the KVM over IP 2.5 Setting the OMU Boot Sequence and RAID Disk 2.6 Installing the CGP LMT and SGSN LMT

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 15

(Optional) Setting IP Addresses for External Ports on the SMM)


Note: You need to set IP addresses for external ports on the SMM only when the SMM needs
to be remotely maintained.

Connect the PC and the COM port on the SMM through a serial port cable. Log in to the SMM through the serial port tool, such as the HyperTerminal and Tera Term. The user name is root and the password is huaweiosta. Then, set the baud rate of the COM port to 115200.

Set an IP address: smmset -l smm -t eth0 -d staticip -v IP address mask broadcast address

Add a route: smmset -l smm -t eth0 -d routeadd -v destination IP address host/net mask gateway Query for the IP address and route: smmget -l smm -t eth0 -d staticip smmget -l smm -t eth0 -d displayroutes

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 16

(Optional) Setting IP Addresses for External Ports on the SMM)

The SMM is used to manage all hardware devices in the advanced telecom computing architecture
(ATCA) subrack. After the SMM is installed, two internal IP addresses will be available, corresponding to the IP address of the Base 1 plane and the IP address of the Base 2 plane respectively. The SMM uses the internal IP addresses to process internal data of the subrack. Slot Number 14 Network Port eth1 eth2 15 eth1 IP Address 172.17.(128 + Subrack number).112 172.16.(128 + Subrack number).112 172.17.(128 + Subrack number).120 Subnet Mask 255.255.0.0 255.255.0.0 255.255.0.0 Function To interconnect with the Base 2 plane To interconnect with the Base 1 plane To interconnect with the Base 2 plane

eth2

172.16.(128 + Subrack number).120

255.255.0.0

To interconnect with the Base 1 plane

Note: In this slide, "(128 + Subrack number)" represents the sum of 128 and the subrack number. For example, if the subrack number is 2, "172.16.(128 + Subrack number).120" represents an IP address of 172.16.130.120. IP addresses of the Base planes are used for internal management of the SGSN9810. These IP addresses are internally unique, and they do not conflict with external IP addresses; however, you are not advised to set external IP addresses to the IP addresses in the same network segment as the internal IP addresses.
HUAWEI TECHNOLOGIES CO., LTD. HUAWEI Confidential
Page 17

Chapter 2 Preparations for Software Installation


2.1 Connecting Cables

2.2 Setting IP Addresses for External Ports on the SMM


2.3 Checking the DIP Switches of the SDM 2.4 Using the KVM over IP

2.5 Setting the OMU Boot Sequence and RAID Disk


2.6 Installing the CGP LMT and SGSN LMT
HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 18

Using the KVM over IP

The methods for logging in to the SMM through the KVM over IP are as follows:
1. Login through the maintenance network: Connect the PC with the external network port on the SMM by using network cables, and enter the external IP address of the SMM in the Microsoft IE address bar.

2. Login through local direct connection: Set an IP address (in the same network segment as
the internal IP addresses of the SMM), such as 172.16.128 + Subrack number.200, for the PC. Use the network cable to connect the PC and any Base network port on the back board of the switching network board in slot 6. Then, enter the internal IP address of the SMM in the Microsoft IE address bar.

The user name is root and the password is huaweiosta.

Method 1 implements remote login, and method 2 implements local login. Select a method according to actual conditions.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 19

Using the KVM over IP


After logging in to the SMM, choose Blade > Remote Control. Then, you can

view the status of other boards in the current subrack. Click the slot where the OMU resides to log in to the OMU. The user name is root and the password is huawei.

If no IP address is set for the OMU, this is the only method to log in to the OMU.

Note:

1. Before using the KVM over IP, you must install the Java runtime environment
(JRE) on the PC. 2. Slots of boards that are logged in through the KVM over IP are numbered from 1 rather than 0.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 20

Using the KVM over IP

Click the slot where the OMU resides, and enter the user name and password. Then, the login interface is displayed at the bottom of the window.

In the drop-down list box, select the slot, and rightclick Cold Reset to reset the board in the selected slot.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 21

Chapter 2 Preparations for Software Installation


2.1 Connecting Cables

2.2 Setting IP Addresses for External Ports on the SMM


2.3 Checking the DIP Switches of the SDM 2.4 Using the KVM over IP

2.5 Setting the OMU Boot Sequence and RAID Disk


2.6 Installing the CGP LMT and SGSN LMT
HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 22

Setting the OMU Boot Sequence and RAID Disk


Set the OMU boot sequence.

Log in to the OMU through the KVM over IP, and reset the OMU. During the start of the OMU, press Delete to enter the basic input/output system (BIOS) menu.

Enter the boot menu, choose Boot Device Priority, and then press Enter. You can select 1st Boot Device to start from the hard disk, or select 2nd Boot Device to start from the network. Then, press F10 to save the setting and exit the boot menu.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 23

Setting the OMU Boot Sequence and RAID Disk


Set the redundant array of independent disks (RAID).
When the OMU starts, press Ctrl+C. After the SAS1064 menu is displayed, select C1064E,

and press Enter. Select RAID Properties. If the following interface appears, it indicates that

the RAID disk is configured. In such a case, select Manage Array to delete the RAID disk.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 24

Setting the OMU Boot Sequence and RAID Disk


Set the RAID disk.

Select RAID Properties, and select Create IM Volume. When the following interface appears, move the cursor to the column of RAID Disk in the first row. Then, enter a space. If the input prompt appears, press D, and then Enter. After the setting, Yes is displayed. Perform the preceding operations for RAID Disk in the second row.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 25

Setting the OMU Boot Sequence and RAID Disk


Set the RAID disk.
Press C, and select Save changes then exit this menu. Press Esc twice, select

Exit the configuration utility and Reboot, and press Enter. Then, the OMU restarts.
After the software on the OMU is installed, you can run DSP BRDRAID on the

LMT to query for the type and status of the RAID disk.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 26

Chapter 2 Preparations for Software Installation


2.1 Connecting Cables 2.2 Setting IP Addresses for External Ports on the SMM 2.3 Checking the DIP Switches of the SDM 2.4 Using the KVM over IP 2.5 Setting the OMU Boot Sequence and RAID Disk 2.6 Installing the CGP LMT and SGSN LMT

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 27

Installing the CGP LMT and SGSN LMT


To install the LMT, simply run the installation program. Install the

LMT to the default directory. Do not change the installation directory randomly.
Run setup.bat. The installation sequence number is SGSN9810 (case

sensitive).
After setup.bat is executed, both the CGP LMT and the SGSN LMT

are installed.
Currently, the LMT supports the Windows 2000 and Windows XP

operating systems, but does not support the Windows NT operating system.
The LMT provides you two language versions: English and Chinese.

You can select a language according to actual requirements.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 28

Installing the CGP LMT and SGSN LMT


When starting the LMT, you can add a CGP server by clicking the button behind

Server. In the displayed dialog box, enter the office name, dynamic IP address of the OMU, user name admin, and initial password lem. Then, you can log in to the LMT. After login, you can change the password at system prompt. Note: The dynamic IP address of the OMU refers to the LMT maintenance IP address set during the installation. Information about the dynamic IP address will be provided later in this course.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 29

Question
How to set IP addresses for external network ports on the SMM? How to log in to the OMU and then operate it if no IP address is set for the

OMU?

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 30

Chapter 1 Overview of Software Installation Chapter 2 Preparations for Software Installation

Chapter 3 Process of Software Installation

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 31

Chapter 3 Process of Software Installation


3.1 Installing Software on the OMU by Using the INU4Win Tool

3.2 Adding MEs and Process Groups on the LMT


3.3 Installing the License

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 32

Installing OMUs by Using INU4WIN


Obtain INU4WIN and install the media.

Download the Windows installation package of the INU , namely, INU4WIN.rar . Copy the package to the PC and decompress the package.

Copy the installation package media to the software folder in the INU4WIN

directory. The media required for OMU installation are as follows: SLES10.2IMG32Q_TO_SLES10.3IMG32Q00x.tar SLES10.3IMG32Q1.x.tar SLES10.3INST32Q1.x.tar ORACLE11GV101R001C01.tar OMU_ADDONSLES10.3I386Q1.x.tar BASICUTILITYV100R00xC0xSPCxxx.tar

CGPV100R00xC0xSPCxxx.tar

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 33

Installing Software on the OMU by Using the INU4Win Tool


Install software on the OMU.
Two installation methods are available:

Incremental installation: This method is used when the operating system and database are installed before you install software such as OMU service processes.

Complete installation: This method is used when software on both the active
and standby OMUs needs to be reinstalled. Using this method, you can install OMU service processes and OMU required software, such as operating system and database, at the same time.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 34

Installing Software on the OMU by Using the INU4Win Tool


Install software on the OMU through the incremental installation method.

Run INU4Win.exe in the INU4WIN directory. After the interface similar to the right figure appears, select the network adapter that is connected with the Base port on the switching network

board in the subrack of the


OMU (where software is to be installed). Then, connect the OMU and the network adapter through network cables.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 35

Installing Software on the OMU by Using the INU4Win Tool


Install software on the OMU through the incremental installation method.
Click Next. The INU4Win tool saves the IP address of the network adapter,

and then reconfigures an IP address 192.168.1.2 for Dynamic Host


Configuration Protocol (DHCP) interception and two maintenance IP addresses 172.16.128.254 and 172.17.128.254 in the Base plane.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 36

Installing Software on the OMU by Using the INU4Win Tool


Install software on the OMU through the incremental installation method.
Set the position information about the OMU to be installed. See the

following dialog box. The parameters are described in the next slide.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 37

Board type Software path

Optional values of this parameter are OMU and Other. Here, select OMU. This parameter specifies the location of the software package. By default, the software package is stored in the software folder of the INU4WIN directory. Click Check to check whether the software to be installed is present in the specified path.

Installation Mode

If a correct operating system is already installed on the target OMU, select Incremental Installation. If no operating system is installed on the target OMU, select Complete Installation. Here, select Incremental Installation.
To install software to a single OMU, select Single-server mode. To install software to two OMUs, select HA mode. Here, select HA mode.

Running Mode

Installation language Backup File

Optional values of this parameter are English and Chinese. Select English or Chinese based on actual requirements. This parameter specifies whether to back up installation files of the OMU. If no installation files are backed up, No backup is displayed automatically. If installation files are backed up, you can use the backup installation files to restore the previous software of the OMU. These parameters specify the IP address, subnet mask, and gateway IP address for logging in to the OMU through the LMT. This parameter specifies whether to copy the software package to the OMU. If it is not selected, you can upload the software package to the OMU by File Transfer Protocol (FTP). This parameter specifies the subrack number and slot number of the active OMU. The subrack number ranges from 0 to 19, and the slot number ranges from 0 to 13. This parameter specifies the host name of the active OMU. This parameter specifies the network port on the active OMU. Through this network port, the active OMU interworks with external devices. This parameter specifies the physical IP address, subnet mask, and gateway IP address of the active OMU. This parameter specifies the subrack number and slot number of the standby OMU. The subrack number ranges from 0 to 19, and the slot number ranges from 0 to 13.

Explicit IP address, Mask and Gateway Copy software to OMU board Primary board Primary host name Primary network port Primary physical IP address Secondary board

Secondary host name


Secondary network port Secondary physical IP address

This parameter specifies the host name of the standby OMU.


This parameter specifies the network port on the standby OMU. Through this network port, the standby OMU interworks with external devices. This parameter specifies the physical IP address, subnet mask, and gateway IP address of the standby OMU.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 38

Installing Software on the OMU by Using the INU4Win Tool


Install software on the OMU through the incremental installation method.
After information about the OMU is configured, click Next. Then, the

INU4Win tool automatically connects to the OMU and starts the installation.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 39

Installing Software on the OMU by Using the INU4Win Tool


Install software on the OMU through the incremental installation method.
After the installation is complete, the installation progress is displayed as

100%. Click Stop and return to return to the configuration dialog box.
Click the close button in the upper right corner of the configuration dialog

box. When the confirm dialog box is displayed, disconnect the network cable between the PC and the Base network port on the switching network board. Then, click Confirm to exit.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 40

Installing Software on the OMU by Using the INU4Win Tool


Install software on the OMU through the complete installation method.

In complete installation, you need to click the installation button after the board configuration information is specified, which is the only difference from incremental installation. After the installation button is clicked, the INU4Win tool automatically resets the OMU and then starts the installation. In incremental installation, the INU4Win tool does not reset the OMU on which software is to be installed.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 41

Chapter 3 Process of Software Installation


3.1 Installing Software on the OMU by Using the INU4Win Tool

3.2 Adding MEs and Process Groups on the LMT


3.3 Installing the License

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 42

Adding MEs and Process Groups on the LMT


Configure hardware.

Connect the PC to the rear boards of OMUs by using cables. Select the network port configured during the installation of the OMU, such as CARD4/LAN0. During the installation, use the LMT management IP address to log in to the CGP LMT. After the login, select MML Command and the CGP on the Object navigation tree. The MML command window appears. Run SET NET to set Cascading mode to Internal switch boards. Run ADD RACK to add a rack. Run ADD SUBRACK to add a subrack. Set Subrack version to T8280, the front board of the switching board to SWUA1, the rear board of the switching board to SWIA1, and the service subrack to SWIA0.Set the slot numbers of the SRMUs to the slot numbers where a pair of ECUs resides, such as slots 1 and 3. Run ADD BRD to add active and standby OMUs that are in slots 0 and 2 of subrack 0. Set ME type to COMMON, the front board type to UPBA2, and the rear board type to USIA7. Run ADD BRD to add ECUs/EPUs. Set the ME type to SGSN, the front board type to MSPB0/UPBA3, and the rack board type to PFIA0/ETIA0. After the configuration is complete, check whether the configuration has taken effect on the device panel.
HUAWEI Confidential
Page 43

HUAWEI TECHNOLOGIES CO., LTD.

Adding MEs and Process Groups on the LMT


Add the SGSN9810 package on the LMT.

Upload the SGSN9810 package SGSN_SRV_V900R010C02SPCXXX.tar to /opt/pub/software/tmp on the hard disk of the OMU. Then, load the SGSN9810 package. Upload method 1: Use the Secure File Transfer Protocol (SFTP) function of the CGP LMT. Click Maintenance, and select File Transfer Service. Then, select Software package(auto loading) in the Remote Directory window. After the upload, the CGP automatically loads the SGSN9810 package. Note: Before the upload, run SET FTPSENABLE to enable the SFTP function.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 44

Adding MEs and Process Groups on the LMT


Add the SGSN9810 package on the LMT.
Upload method 2: Use the WinSCP3 software of a third party when the File

Transfer Protocol (FTP) tool of the LMT is unavailable. Specify Host name as the external IP address of the OMU, that is, the IP address for logging in to the OMU through the LMT. The user name is root and the password is huawei. After login, you can see that the left window displays the local hard disk, and the right window displays the hard disk of the OMU. After the SGSN9810 package is uploaded, run LOD PKG to load and run the

SGSN9810 package. Specify File name as the full name of the SGSN9810
package. That is, the extension name .tar should be also entered.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 45

Adding MEs and Process Groups on the LMT


Add the SGSN9810 package on the LMT.
After the SGSN9810 package is loaded, run LST PKG to query for

information about the SGSN9810 package.


+++ CGP/*MEID:0*/ 2010-09-10 09:10:19+00:00 O&M #595 %%LST PKG: PKGT=VERPKG, MET=SGSN;%% RETCODE = 0 Operation succeeded The ME-related packages are as follows -------------------------------------ME type = SGSN Package type = Version package ME version = V900R010C02 File name = SGSN_SRV_V900R010C02.tar (Number of results = 1) --END

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 46

Adding MEs and Process Groups on the LMT


Add SGSN9810s on the LMT.
Run ADD ME to add SGSN9810s. To add an SGSN9810, set ME ID to 6,

ME version to the version of the SGSN9810 to be added, and ME vendor to Huawei. The execution of ADD ME takes about 10 minutes. After ADD ME is executed, you can view the added SGSN9810 under

Object Navigation Tree.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 47

Adding ME Packages and Process Groups on the LMT


Add OMU/ECU/EPU Process Groups

Select the SGSN from the object navigation tree. The MML command window of the SGSN appears.

Run ADD PROCESSGRP and type the numbers of the slots where the active/standby OMUs reside to add OMPGP process groups.

Run ADD PROCESSGRP to add the CPGP, UIPGP, ECUGP, EPUGP, and LIPGP in sequence. The UIP and LCP can be configured on only one pair of ECUs. The ECU process group needs to be configured on each pair of ECUs. The EPU process group needs to be configured on each pair of EPUs. The LIP process can be configured on only one pair of EPUs. LCPGP/UIPGP/ECUGP/EPUGP/LIPGP

LST PROCESSGRPOMUECUEPU

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 48

Question
What is the difference between the incremental installation method and

complete installation method of the INU4Win tool?


How to connect cables for logging in to the OMU through the LMT? What are the procedures for adding SGSN9810s and process groups on

the LMT?

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 49

Chapter 3 Process of Software Installation


3.1 Installing Software on the OMU by Using the INU4Win Tool

3.2 Adding MEs and Process Groups on the LMT


3.3 Installing the License

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 50

Installing the License

Run ADD PROCESSGRP to add the LCP process group on the ECU.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 51

Installing the License


Upload the license file.

In the right pane, set Package type to License file. Then, drag the license file

to the right pane. The license file is stored in \opt\pub\software\tmp.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 52

Installing the License


Activate the license file.

In the MML interface of the SGSN9810, run ACT LICENSE to

activate the license file. The license file name must be the standard full
name of the uploaded license file, that is, the specified license name must be in the LICXXX.dat format. After the license file is activated, you can run DSP LICENSE to query for the configuration of the license file on the SGSN9810.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 53

Summary

Sum mary

This course describes the SGSN9810 software

installation process, including the process of installing software on the OMU, process of loading the SGSN9810 package, process of adding service processes, and process of installing the license.

HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI Confidential

Page 54

Thank you