Sunteți pe pagina 1din 14

SIEMENS

SIMATIC PRODUCT OVERVIEW

SIEMENS
SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

1/2

21 November 2013

SIEMENS

Objectives

- Overview On Simatic S7 Product. - Familiar With S7-200, S7-300 & S7-400.

- Different Between Siemens Programming Device.

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

2/2

21 November 2013

SIEMENS

SIMATIC PRODUCT OVERVIEW

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

3/2

21 November 2013

SIEMENS

SIMATIC OVERVIEW
Operating Panel PG

PC Panel

MPI Ethernet ProfiBus

S7-200

S7-300

S7-400

SIMATIC NET
ProfiBus DP Bus System

DP Slaves

DP/PA

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

4/2

21 November 2013

SIEMENS

Bus System

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

5/2

21 November 2013

SIEMENS

SIMATIC S7-200
The micro PLC that offers maximum automation at minimum cost. Extremely simple installation, programming and operation. Large-scale integration, space-saving, powerful. Can be used both for simple and complex automation tasks. Suitable for applications where programmable controllers would not have been economically viable in the past. With powerful communication options (PPI, PROFIBUS DP, AS-Interface) Digital inputs/outputs to supplement the onboard I/Os of the CPUs EM 277: For connecting S7-22x to PROFIBUS DP and MPI EM 253: Function modules for simple positioning tasks (1 axis) EM 231: For user-friendly, high precision temperature detection

CPUs

AI/AO

DI/DO

EM 277 PROFIBUS DP module

EM 253 positioning module

EM 231 thermocouple module

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

6/2

21 November 2013

SIEMENS

SIMATIC S7-300
CPU 313C-2 DP The compact CPU with integrated digital I/Os and PROFIBUS DP master/slave interface. CPU 315-2 DP The CPU with medium to large program memory, High processing performance in binary and floating-point arithmetic, PROFIBUS DP master/slave interface. CPU 319-3 PN/DP The CPU with high command processing performance, large program memory and quantity framework for demanding applications, Used as central controller in production lines with central and distributed I/O on PROFIBUS and PROFINET. CPU 317T-2 DP The CPU with integrated technology/motion control functionality, For multi-sector automation tasks in the construction of series machines, special machines and plants.
SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

CPU 319-3 PN/DP

CPU 313C-2 DP

CPU 317T-2 DP
7/2

CPU 315-2 DP
21 November 2013

SIEMENS

SIMATIC S7-300
CPU S7-300 Signal Modules:
Digital input modules Digital output module Analog input modules Analog output modules CPU IM DI DO AI AO FM CP

Interface Modules:
The IM360/IM361 and IM365 make multi-tier configurations possible.

Function Module (FM)


- Counting - Positioning - Closed-loop control.

Communication Processors (CP)


- Point-to-Point connections - PROFIBUS - Industrial Ethernet.

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

8/2

21 November 2013

SIEMENS

Training Unit Hardware


CPU 313C-2 DP:
The compact CPU with integrated digital I/Os PROFIBUS DP master/slave interface With process-related functions For tasks with special functions For the connection of standalone I/O devices Note: Micro memory card required to operate the CPU.

Signal Modules:
Digital input modules Digital output module Analog input modules Analog output modules CPU DI DO AI AO

Memory Card
A slot is provided for a memory card. The memory card saves the program contents in the event of a power outage without the need for battery. RAM cards are available with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte. Flash EPROM cards are available with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte, 4MByte, 8MByte, 16MByte.
SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

9/2

21 November 2013

SIEMENS

Training Unit Hardware


Mode Selector:
MRES =Memory reset function (Module Reset) STOP = Stop mode, the program is not executed. RUN = Program execution

Status Indicators.
SF = Internal CPU fault or fault in module. BATF = Battery fault; battery empty or non-existent. DC5V = Internal 5 VDC voltage indicator. FRCE = FORCE; indicates that at least one input or output is forced. RUN = Flashes when the CPU is starting up, then a steady light in Run mode. STOP = Shows a steady light in Stop mode. Flashes slowly for a memory reset request, Flashes quickly when a memory reset is being carried out, Flashes slowly when a memory reset is necessary because a memory card has been inserted.

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

10/2

21 November 2013

SIEMENS

SIMATIC S7-400
CPU 416-2
High-performance CPUs in the high-end performance range Applicable for plants with high requirements in the high-end performance range

CPU 414-4H
Fault-tolerant automation system with redundant configuration For applications with high failure safety requirements Processes with high restart costs, expensive downtimes, little supervision, and few maintenance options Hot standby: Automatic reaction-free switching to the standby unit in the event of a fault

CPU 414-4H

CPU 416-2

CPU 414-4FH
Failsafe automation system for plant with high safety requirements If required, also fault tolerant through redundant configuration
CPU 414-4FH SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

11/2

21 November 2013

SIEMENS

SIMATIC S7-400
The power PLC for the mid to upper performance range Performance-graded range of CPUs Extensive selection of modules Expandable design to over 300 modules Backplane bus integrated in the modules Can be networked with - (MPI) - PROFIBUS - Industrial Ethernet

S7-400 Rack
UR1 (Universal Rack) with up to 18 modules UR2 (Universal Rack) with up to 9 modules UR2-H (Universal Rack For H-SYS) ER1 (Expansion Rack) with up to 18 modules ER2 (Expansion Rack) with up to 9 modules

PS

CPU

DI

DO FM CP

IM

Rack UR2-H (18 Slot) SIMATIC S7


SIEMENS LTD EGYPT 2007 All Rights Reserved

Rack UR2 (9 Slot) 21 November 2013

12/2

SIEMENS

SIMATIC S7-400
Fault LEDs
LEDs for the CPUs statuses and faults, both internal and external

Memory Cards
Mode Selector
MRES = Memory reset function (Module RESet) STOP = STOP mode RUN = Program execution, read-only access possible from PG. RUN-P= Program execution, read/write access possible from PG.

MPI / DP Interface DP Interface


For connecting to distributed peripherals

EXT-BATT

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

13/2

21 November 2013

SIEMENS

SIMATIC Programming Device


Field PG Intel Pentium M processor.

Power PG

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

14/2

21 November 2013

S-ar putea să vă placă și