Sunteți pe pagina 1din 75

Security Level: Internal

RRU3804 Introduction

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Objectives

Master the feature of RRU3804 and SRXU Master the hardware installation method of

RRU3804 and SRXU module


Master the hardware installation method of

cables of RRU3804 and SRXU

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 2

Reference

Huawei DBS Hardware Installation RRU3804 User Guide

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 3

Chapter 1 The Feature of RRU3804 and SRXU


Chapter 2 RRU3804 and SRXU Hardware Installation Chapter 3 Relative Cables Hardware Installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 4

DBS3800 Main Product Family Overview

+
RRU3801C RRU3804 SRXU

BBU3806

BBU3806C

Baseband unit
BBU3806: Indoor baseband unit. BBU3806c:Outdoor baseband unit . RRU3801C: an outdoor remote radio unit.

Remote radio unit

RRU3804: an outdoor remote radio unit that is connected to the SRXU supports 4-way RX diversity. SRXU: an extended RF interface module that provides two RX channels for RF signals.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 5

Typical DBS3800 Deployment Scenarios


This representative scenarios system consists of:

BBU3806 module RRU3804 module Various cables Antenna and Feeder system
RRU 3804C

Antenna TMA RF jumper

Feeder A&F system grounding cable RF jumper

RNC

-48V DC power

Power cable
BBU3806 Power cable Trunk cable

-48V DC power

Grounding cable

Fiber or CPRI high-speed signal cable

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 6

Appearance of RRU3804

Front view Without housing

Side view

Front view With housing

Note: With the development of product, there is a little different of housing.


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 7

RRU 3804 Main Function


The RRU3804 receives RF signals from the antenna system, down-converts the RF signals to IF signals, and then transmits them to the BBU or the macro NodeB after amplification, analog-to-digital conversion, digital down-conversion, matched filtering, and Digital Automatic Gain Control (DAGC). Support 12dB, 24dB gain TMA RTWP statistic and report Interference scan function Standing wave detect and report Support ASIG (Antenna Interface Standards Group) 2.0 Receiver reference sensitivity typical value -125.5dBm Intermodulation sensitivity -115dBm RRU3804 connected to the SRXU supports 4-way RX diversity

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 8

Appearance and Panels of RRU3804

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 9

Ports on the Panels of RRU3804


Items Label
RX_IN/OUT Ports at the bottom RET/PWR_SRXU ANT_TX/RXA ANT_RXB

Description
Interconnection port between combined cabinets Port for RET antenna /Power output to the SRXU Main TX/RX diversity port Port for RX diversity
Difference with RRU3801C

RS485/EXT_ALM
Ports on the cabling cavity CPRI_E CPRI_W RTN(+) NEG(-) PGND

Alarm port
Optical ports Power supply ports

Grounding bolt

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 10

LEDs on RRU3804----- I
Label RUN Color Green Status ON OFF Description The module has power input, yet the module is faulty The module has no power input or is reporting alarms

1s on, 2s off
0.5s on, 0.5s off ALM Red ON OFF TX_ACT Green ON OFF

The module is operational


Software is being loaded to the module The module is reporting alarms (excluding VSWRrelated alarms The module is operational The module is running No specific meaning

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 11

LEDs on RRU3804----II
Label VSWR CPRI_ W Color Red Red/g reen Status ON OFF ON (green) Description VSWR-related alarms are reported No VSWP-related alarm is reported The CPRI link is normal

ON (red)
0.5s ON, 0.5s OFF (red) OFF

The optical module receives local alarms related to LOS


The CPRI is out of lock The optical module is not in position or is powered off The CPRI link is normal The optical module receives local alarms related to LOS

CPRI_E

Red/g reen

ON (green) ON (red)

0.5s ON, 0.5s OFF (red)


OFF

The CPRI is out of lock


The optical module is not in position or is powered off

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 12

RRU3804 Configuration Specification

Cell Description ( Sector X Carriers )

Number of RRU

Sectors

Carriers per Sector

TX power/Carrier

1X1, 1X2, 1X3, 1X4

1,2,3,4

60,30,20,15W

31
3 2 3 3 3 4

3
3 3 3

3
3 3 3

1
2 3 4

60W
30W 20W 15W

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 13

Appearance of SRXU

Front view With housing

Side view

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 14

Panels of the SRXU

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 15

Ports and LED on the Panels of SRXU


Item
Ports at the bottom

Label
PWR_SRXU ANT_RXC ANT_RXD RX_IN/OUT RET

Description
Socket for power supply Ports for RX diversity Ports for RX diversity Port for interconnection between combined cabins Port for the RET antenna Optical ports
Difference with RRU3801C

Ports on the cabling cavity

CPRI_E CPRI_W

LEDS

The meaning of LEDs on the SRXU please refer to LEDs on the RRU3804.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 16

RRU Features Comparison


RRU3801C
Diversity method Supports 2-way RX diversity

RRU3804
Supports 4-way RX diversity with SRXU

Power output

20W or 40W

60W (40% PA efficiency ) Only support frequency band :2100MHz (RX:1920~1980MHz; TX:2110~2170 MHz ) Two CPRI interfaces 1.25G multi-mode 10km 1.25G Single-mode 40km Support -48V DC input only Input interface should be OT terminal

Frequency band

Band~

CPRI interface

Two CPRI interfaces Support 1.25G Single-mode

Voltage

Support 220VAC and -48V DC input

The data configuration and software downloading steps are almost same
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Page 17

RRU Specification Comparison


RRU3801C RRU3804 SRXU

Dimension (WDH) Weight

380mm200mm610 mm (including housing) 20kg

280mm155mm488mm (including the mounting plate and housing) module15kg module +housing16kg

260 mm x 60 mm x 480 mm

6 kg

Power consumption

240W

280W

30 W

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 18

Chapter 1 The Feature of RRU3804 and SRXU


Chapter 2 RRU3804 and SRXU Hardware Installation Chapter 3 Relative Cables Hardware Installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 19

Chapter 2 RRU3804 and SRXU Hardware Installation


2.1 Hardware Installation Overview 2.2 RRU3804 Installation 2.3 SRXU Installation 2.4 RRU 3804 and SRXU Cable Installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 20

Hardware Installation Scenario Overview

Single module installation

Two modules installation

+
Three modules installation
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Page 21

Space Requirements of the RRU3804 /SRXU


Space Requirements of One RRU3804 with and Without the SRXU Space Requirements of Multiple RRU3804s with and Without the SRXUs.

Recommended space requirements

minimal space requirements

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 22

Hardware Installation Comparison


Installation way Single installation 40W RRU3801C
Cabin +housing; Distance between hole center 210*378 M10*75 bolt

RRU3804
Mounting plate +housing; Distance between hole center 210*270 M10*75 bolt

Centralized installation

3 RRU cabins; Distance between hole center 210*378 M10*75 bolt

3*(mounting plate +housing); Distance between hole center 210*270 M10*75 bolt

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 23

Cable and Structure Comparison


Item
Installation piece CPRI Power cable RF AISG Combined cabin

40W RRU3801C
Single cabin and 3 RRU cabins N/A Bottomaviation head N/A N/A N/A

RRU3804
Mounting plate N/A Cabling cavity OT terminal N/A N/A N/A 1 485 or 1 trunk nodeDB9 dont support all at same time N/A

Remark
The distance between hole center:210*378 210*270 Cabling cavity, SFP Can modify on site bottomDIN Bottom, waterproof DB9 Bottom, water proofDB9

Alarm cable

4 trunk nodesDB15

All in cabling cavity

Grounding line

N/A

Support two hole

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 24

Replacing RRU3801C

RRU3804 can share installation hole for replacing RRU3801C

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 25

Chapter 2 RRU3804 and SRXU Hardware Installation


2.1 Hardware Installation Overview 2.2 RRU3804 Installation 2.3 SRXU Installation 2.4 RRU 3804 and SRXU Cable Installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 26

RRU3804 Installation
RRU 3804 hardware installation consists of: Installing a single RRU3804 Installing two RRU3804s Installing three RRU3804s

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 27

RRU3804 Installation
Installing a Single RRU3804
Scenario 1 the mounting plate of the single RRU3804 on the metal pole

1 2

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 28

RRU3804 Installation
Installing a Single RRU3804
Scenario 1 the mounting plate of the single RRU3804 on the metal pole

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 29

RRU3804 Installation
Installing a Single RRU3804
Scenario 1 the mounting plate of the single RRU3804 on the metal pole

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 30

RRU3804 Installation
Installing a Single RRU3804
Scenario 2 installing the mounting plate of the single RRU3804 on the wall

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 31

RRU3804 Installation
Installing a Single RRU3804
Scenario 3 installing the single RRU3804 module 3

M6X20

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 32

RRU3804 Installation
Installing two RRU3804s
Scenario1 installing the mounting plate of the two RRU3804 on the metal pole

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 33

RRU3804 Installation
Installing two RRU3804s
Scenario 1 installing the mounting plate of the two RRU3804 on the metal pole

5 6

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 34

RRU3804 Installation
Installing two RRU3804s
Scenario 2 installing the mounting plate of the two RRU3804 on the wall

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 35

RRU3804 Installation
Installing two RRU3804s
Scenario 3 installing the two RRU3804 modules 1 2

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 36

RRU3804 Installation
Installing two RRU3804s
Scenario 3 installing the two RRU3804 modules 4

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 37

RRU3804 Installation
Installing two RRU3804s
Scenario 3 installing the two RRU3804 modules 9 8

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 38

RRU3804 Installation
Installing two RRU3804s
Scenario 1 installing the mounting plate of the three RRU3804 on the metal pole 1 4

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 39

RRU3804 Installation
Installing two RRU3804s
Scenario 1 installing the mounting plate of the three RRU3804 on the metal pole 5

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 40

RRU3804 Installation
Installing two RRU3804s
Scenario 2 installing the mounting plate of the three RRU3804 on the wall 3

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 41

RRU3804 Installation
Installing two RRU3804s
Scenario 2 installing the mounting plate of the three RRU3804 on the wall 4

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 42

RRU3804 Installation
Installing two RRU3804s
Scenario 3 installing the three RRU3804 modules 3

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 43

RRU3804 Installation
Installing two RRU3804s
Scenario 3 installing the three RRU3804 modules 5 7

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 44

RRU3804 Installation
Installing two RRU3804s
Scenario 3 installing the three RRU3804 modules 8

10

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 45

Chapter 2 RRU3804 and SRXU Hardware Installation


2.1 Hardware Installation Overview 2.2 RRU3804 Installation 2.3 SRXU Installation 2.4 RRU 3804 and SRXU Cable Installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 46

SRXU installation
SRXU hardware installation consists of: Installing the SRXU on a single RRU3804 Installing the SRXUs on the two RRU3804s Installing the SRXUs on the three RRU3804s

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 47

SRXU Installation
Installing the SRXU on a single RRU3804
1

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 48

SRXU Installation
Installing the SRXU on a single RRU3804

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 49

SRXU installation
Installing the SRXUs on the two RRU3804s
Scenario 1 Side-mounted installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 50

SRXU installation
Installing the SRXUs on the two RRU3804s
Scenario 1 Side-mounted installation 4 5

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 51

SRXU Installation
Installing the SRXUs on the two RRU3804s
Scenario 1 Rear-mounted installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 52

SRXU installation
Installing the SRXUs on the three RRU3804s

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 53

SRXU Installation
Installing the SRXUs on the three RRU3804s
4

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 54

Chapter 2 RRU3804 and SRXU Hardware Installation


2.1 Hardware Installation Overview 2.2 RRU3804 Installation 2.3 SRXU Installation 2.4 RRU 3804 and SRXU Cable Installation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 55

Installing the PGND cable of RRU3804/SRXU


Connecting the PGND cable (only RRU3804 is installed)

The green and yellow PGND cable is a single cable with a cross-sectional area of 16 mm2. Both ends of the cable are OT terminals to connect to the grounding bolt on the RRU3804 module. If you prepare the cable by yourself, it is recommended to use a copper-based cable with a minimum cross-sectional area of 16 mm2.

PGND

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 56

Installing the PGND cable of RRU3804/SRXU


Connecting the PGND cable (both RRU3804 and the SRXU are installed)
Connect a PGND cable between the RRU3804 and the SRXU. Then connect one of the OT terminal on the other PGND cable to the grounding bolt on the RRU3804 module.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 57

Installing the Power Cable of RRU3804


RRU3804/SRXU only support the -48V DC power cable
Step 1: Route the power cable. One end of the cable is two OT terminals, and the other end is bare. The OT terminals need to be made on site.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 58

Installing the Power Cable of RRU3804


Step 2: Add two OT terminals to one end of the power cable
A. Determine l the lengths of power cable for different operation according to the scales on the cover plate of the cabling cavity as shown: B. Based on the determined lengths, remove the jacket and shielding layer from the power cable. Then remove the jacket of a specified length from each wire.

D. Remove about 15mm jacket from the power cable

C. Add an OT terminals to each wire

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 59

Installing the Power Cable of RRU3804


Step 3: Remove the waterproof fillers from the cable troughs of the cabling cavity. Route the power cable along its dedicated cable trough.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 60

Installing the Power Cable of RRU3804


Step 4: Open the cover over the terminals for the power cable

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 61

Installing the Power Cable of RRU3804


Step 5 :Remove the screw on the strap labeled PGND. Step 6 :Press the strap on the exposed shielding layer of the power cable, then tighten the screw. Step 7 :Connect the OT terminal on the blue -48V DC wire to the terminal labeled NEG(-). Connect the OT terminal on the black or brown GND wire to the terminal labeled RTN(+). Then tight the screw. Step 8 :Close the cover. Step 9 :Bind the -48V DC power cable to the binding slot in the lower angle piece.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 62

Installing the Power Cable of RRU3804


Step 10:Connect the other end of the power cable grounding.
a. Remove about 50mm jacket from the power cable. b. Twist the shielding layer of the power cable into one strand, and then wrap the strand with heatshrinkable tube of 5. d. Wrap the power cable with the heatshrinkable tube of 14 at the point where the shielding layer is removed . f. Connect the PGND cable to the shielding grounding bar of power supply equipment. g. Add OT terminals to the blue 48 V wire and the black GND wire, and then connect the OT terminals to the wiring terminals on the power supply.

C. Add a OT terminal to the other end of the PGND cable.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 63

Installing the Power Cable of RRU3804


Step 11: Check whether the power cable of the SRXU needs to be installed. Condition The SRXU is installed. No SRXU is installed. Action Go to step 12 to install the power cable of the SRXU. Go to step 14.

Step 12: Fix the waterproof DB9 connector at one end of the SRXU power cable to the RET/PWR_SRXU port at the bottom of the RRU3804. Step 13: Fix the waterproof B9 connector at the other end of the SRXU power cable to the PWR_SRXU port at the bottom of the SRXU. Step 14: Label the power cable .

The rest cables installation refers to related contents of RRU3801C.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 64

Installing the Power Cable of SRXU


The SRXU uses a shielded DC power cable. The cable feeds power from the RRU3804 to the SRXU. The cable has a waterproof DB9 connector at each end. One end of the DC power cable is connected to the RET/PWR_SRXU port at the bottom of the RRU3804, and the other end is connected to the PWR_SRXU socket at the bottom of the SRXU.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 65

Installing the Optical Cable of RRU3804/SRXU


BBU3806-RRU3804/SRXU CPRI Optical Cable
The CPRI optical cable transmits CPRI signals: between BBU3806 and RRU3801C, between BBU3806 and RRU3804 between RRU3804 and SRXU. The CPRI optical cable is a multi-mode 2-wire cable with DLC connectors at both ends.

BBU and RRU CPRI hardware connection is


same between RRU3801C and RRU3804

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 66

AISG Multi-Wire Cables of RRU3804/SRXU


The five-meter-long AISG multi-wire cable connects the RRU3804/SRXU to
the Remote Control Unit (RCU). If both RRU3804 and SRXU are installed, the AISG multi-wire cable only connects the SRXU and the RCU. This cable is optional. One end of the AISG multi-wire cable is a waterproof DB9 connector, and the other end is a standard AISG female connector

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 67

AISG Extension Cable of the RRU3804/SRXU


When the distance between the RCU and the RRU3804/SRXU is longer than
5 m, the AISG multi-wire cable is not long enough to cover the distance and the AISG extension cable is used. The AISG extension cable is 15 m long. One end of the AISG extension cable is a standard AISG male connector, and the other end is a standard AISG female connector

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 68

RF Jumper of the RRU3804/SRXU

The RF jumper of the RRU3804/SRXU is of two types Antenna jumper: transmits and receives RF signals. Both ends of the antenna jumper have DIN connectors.

Interconnect jumper: transmits RF signals

between two RRU3804s/SRXUs. The interconnect jumper is optional, depending on the site configuration. The interconnect jumper is 2 m long, and both ends have 2W2 connectors The 2W2 connectors at the two ends of the interconnect jumper are linked to the ports labeled RX_IN/OUT on two RRU3804s/SRXUs respectively

Waterproofed Joints

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 69

Boolean/RS485 Input Cable of the RRU3804

The cable transmits the 2-channel Boolean alarm signals and 1-channel RS485 signals from external devices to the RRU3804. Thus, the external

signals are monitored.


One end of the cable has a DB15 female connector, and the other end has eight cord end terminals. If the cord end terminals of the cable do no match the ports on the external devices, cut off the cord end terminals and make proper terminals on site.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 70

Cable Connections of one RRU3804

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 71

Cable Connections of one RRU3804 /SRXU

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 72

Cable Connections of Multiple RRU3804s

Optical cable

Power cable

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 73

Cable Connections of Multiple RRU3804s/SRXUs

Power cable Power cable Optical cable

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 74

Thank you
www.huawei.com

S-ar putea să vă placă și