Sunteți pe pagina 1din 38

LG Inverters

Inverter Products Line

iG
0.37 - 4 kW

iS3
2.2 - 22 kW

iV
2.2 - 22(220) kW

iH
30 - 220 kW

LG Inverters

Products Mix (in Quantity)

iV

7%

1%

iH
30 - 220 kW

2.2 - 22(220) kW

iS3
2.2 - 22 kW

23%

1997

69%

iG
0.37 - 4 kW

LG Inverters
Space Vector PWM
Low Total Harmonic Distortion Low Torque Ripple Low Current Ripple

Space Vector PWM Control

Better Efficiency (Low Iron loss in Motor)


Low Motor Heat (Extended Motor Life) High Voltage Utilization (Approx. 15.9% Better) Stable & Smooth Operation (Better Quality Production) High Torque Overall Speed Range

LG Inverters
SIN - PWM

Space Vector PWM Control

Space Vector PWM

LG Inverters

Special Application Demand

LG Inverters
iG's PI Control
Key-Pad PI Selection H 22
0 1 2

Built-in PI Control
Freqeuncy Hi Limit F 23

To Ramp Input F 24 Freqeuncy Lo Limit H1


0~3

F1 Command Frequecny Setting P1 Analog Input Filter Gain Selection F 19 Analog Input Mode Selection F 18 H 30 V1(0~10V) H 24 P Gain H 25 I Gain Analog Input Gain F 20 Analog Input Bias F 21 PI Reference Scale Factor H 23

Multi-Input Mode Selection

Positive Limit

H 29

PI
Negative Limit

I(4~20mA)

Feedback Filter Gain Selection H 26

Feedback Input Gain H 27

Feedback Input Bias H 28 -1

Analog Input Direction Setting F 22

LG Inverters

120V Interface Card

120 Volt Control Interface Card

LG Inverters

Drive View
Windows Display
Parameter Set / Change Graphic Scope Display

Multi-drop Link up to 32 Inverters


Length : Maximum 0.72 mile Baud Rate : 1,200 ~ 19,200 bps

LG Inverters
Available for LG PLC Master-K, New MKS Series Proprietary Protocol Link Available up to 96 Inverters 1 Mbps, Maximum 750m

PLC Interface Option

LG Inverters
Open Protocol Cost-effective Maximum 64 Nodes 125 kpbs / 250 kbps / 500kbps 100m / 250m / 500m

Device Net

LGIS is a member of
*ODVA : Open DeviceNet Venders Association

LG Inverters

PG(Pulse Generator) Interface Option Available For both Differential and Open Collector Type Encoders 500 - 8,000 ppr

LG Inverters
PG Interface
Available for Both Differential and Open collector Type Encoders

Options
Device Net
Open Protocol Cost-effective Networking Maximum 64 Nodes 125 Kbps / 250 Kbps / 500 Kbps 328 feet / 820 feet / 1,640 feet

500 - 8,000 ppr


PLC Interface

External Braking Resistor Available for LG PLC Master-K Proprietary Protocol Link Available up to 96 Inverters 1 Mbps, Maximum 2.46 feet Built-in Braking IGBT iG, iS3, iV : 15 - 30HP Remote Control Cable & Keypad Mounting Fixture

LG Inverters

Quality Certificates

iG

1 & 3, 200/400V, 0.37 - 4 kW

iS3
iV iH

3, 200/400V, 2.2 - 22 kW

ISO9001 ISO14001

3, 200/400V, 2.2 - 22(220) kW 3, 200/400V, 30 - 220 kW


Available in 2000

LG Inverters
STEP 2
Incoming Components Inspection Frequent Interim Inspection

Quality Control & Assurance


Mass Production Quality Assurance

Accelerated Life Test

- test
Defective Rate Management Trend

Mass Production

Keep Rate < 2,500 ppm (0.25%)

Development & Product Reliability

Electric & Electronic Test

Mechanical Test

Environmental Test

STEP 1

LG Inverters
Automatic Assembly

Production Process & Inspections


Components Incoming

Manual Assembly

Test Operation

Packing & Shipping

: Inspection or Test

LG Inverters
Electrical Test

Test Equipment & Facilities


Mechanical Test

Environmental Test

Accelerated Life Test

LG Inverters

Rated Output Range


0.37kW 4kW
200V 400V

iG

General Purpose 200 / 400 Volts 1 phase 0.75 - 1.5 kW 3 Phase 0.37 - 4 kW
General Purpose 200 / 400 Volts 3 phase 2.2 - 22 kW(CT) 3 Phase 3.7 - 30 kW(VT) Vector Control 200 / 400 Volts 3 phase 2.2 - 22(220) kW General Purpose 200 / 400 Volts 3 phase 30 - 220 kW

22kW

55kW

220kW

iS3
iV iH

200V 400V

200V 400V

200V 400V

200V 400V

iG series

1 0.75 - 1.5kW 200 Volts 3 0.37 - 7kW 200 Volts / 400 Volts

iG series
Easy to Use

Generals Features(1/2)

7-Segment Keypad with 5 functional Keys Simple Parameter Setting and Monitoring Parameter Read, Write with Keypad

Powerful Performance
High Starting Torque : 150% Slip Compensation Output Frequency up to 400Hz Acceleration/Deceleration Time 0 ~ 999 second Recovery from Instantaneous Power Failure (Flying Start) Built in Braking Chopper

iG series
Flexible Control

Generals Features(2/2)

Multi-Step Operation( up to 9 Steps) 2 Sets of Selectable Ramp Pattern 3 Programmable Input / 2 Programmable output Adjustable Carrier Frequency 3 ~ 15 kHz

Built In Protective Function


Automatic Retry Stall Prevention Motor & Inverter i2t Over-Current Over-Voltage Under-Voltage

iG series
LG iG Maker A

Tripless Operation

Comparison of Acceleration & Deceleration Capability with Rated Load

16A

16A

Acc. Time : 0.0 seconds with Stall prevention

Acc. Time : 0.7 seconds with Stall prevention

iG series

Stall Prevention

Rapid Acceleration & Deceleration without Load (Flywheel Only)

Acc. Time : 0.0 seconds without Stall prevention

Acc. Time : 0.0 seconds with Stall prevention

iG series

Keypad & Menu

Menu Driven Type Setting - Basic Group - FU1 ( Function Group) - FU2 ( Sequence Group)
Parameter Lock Parameter Read, Write for Copy
FUNC

Optional Remote Cable and Panel Door Mounting Fixture


FUNC

iS3 series

3 2.2 - 22kW 200 Volts / 400 Volts

iS3 series
Easy to Use

Generals Features(1/3)

Keypad with 16 X 2 Alphanumeric LCD display and 10 Functional Keys Optional 6 digit 7-Segment Keypad Parameter Read, Write for Copy and Lock with Keypad

Powerful Performance
High Starting Torque : 150% Automatic Torque Boost Various V/f Pattern Slip Compensation Recovery from Instantaneous Power Failure (Flying Start) Built in Braking Chopper

iS3 series
Flexible Control

Generals Features(2/3)

Output Frequency up to 400Hz Acceleration/Deceleration Time 0 ~ 6,000 second Multi-Step Operation( up to 9 Steps) 8 Sets of Selectable Ramp Pattern 6 Programmable Input / 4 Programmable output Adjustable Carrier Frequency 3 ~ 15 kHz UP/DOWN Operation 3-wire Operation Pre-Programmable Sequence Operation - Pulse Triggered - Time Scheduled Additional Parameter Set for Alternative motor

iS3 series
Built In Protective Function
Automatic Retry Stall Prevention Parameter Lock Rotating Direction Protect Motor & Inverter i2t Over-Current Over-Voltage Low-Voltage Fuse Open Fault History(Recent 2 Faults)

Generals Features(3/3)

iS3 series
Menu Driven Type Setting - DRV (Main Group) - FUN (Function Group) - I / O (Sequence Group) - AUT (Auto Group)
MODE PROG ENTER

Keypad

Parameter Lock Parameter Read, Write and Copy Optional Remote Cable Optional 7-Segment Keypad

REV

RESET

FWD

STOP

iS3 series
CT & VT Dual Rating

Constant Torque

Variable Torque

Inverter Overheat Motor Overheat :150% for 60second.

Inverter Overheat Motor Overheat :120% for 60second.

iH series

3 30 - 55 kW 200 Volts 3 30 - 220 HP 400 Volts

iH series
Easy to Use

Generals Features(1/2)

Keypad with 16 X 2 Alphanumeric LCD display and 10 Functional Keys Optional 6 digit 7-Segment Keypad Parameter Read, Write for Copy and Lock with Keypad

Powerful Performance
High Starting Torque : 150% Automatic Torque Boost 150% Overload Capacity for 1 minute Various V/f Pattern Slip Compensation Recovery from Instantaneous Power Failure (Flying Start)

iH series
Flexible Control

Generals Features(2/2)

Output Frequency up to 400Hz Multi-Step Operation( up to 9 Steps) Acceleration/Deceleration Time 0 ~ 6,000 second 8 Sets of Selectable Ramp Pattern 6 Programmable Input / 5 Programmable output Adjustable Carrier Frequency 1 ~ 6 kHz UP/DOWN Operation 3-wire Operation Automatic Energy Saving Built-in 4 ~ 20mA Output Built-in PI

LG Inverters
FeedBack(4~20mA) Reference
I

Special PI Control for Multi-Motor Control

PI
V1

Opt_Man RUN

P6 FX

P4 P3 P2 P1

Q3 Q2 Q1 AX1

Up to 4 Motors Automatic exchange of Motor PI - Bypass Sleep Interlock

Main Supply

R S T

iS3 iH

U V W

IM
* iS3 customized S/W version

IM

IM

IM

iV series

3 2.2 - 22 kW 200 Volts / 400 Volts

iV series
Closed Loop Vector Control

General Features

True Field Oriented Control with Speed Feedback (Rotor Flux Oriented Control) Precise Control of Speed and Torque Full 4 Quadrant Control Full Torque at Low and ZERO Speed

High Performance
Speed Control Range of 1 : 1,000 0.01 % of Torque Control Accuracy 250 % of Instantaneous Torque Control Capability 3 % of Open Loop Torque Control Linearity

iV series
Flexible Functions

General Features(2/2)

Programmable Analog Input(-10~10V) 2 channel Analog Output(0~10V) 2 channel Programmable Digital Input 7 channel Digital Output 5 channel 2 Sets of Acceleration and Deceleration Ramp with Linear or S-Shape Curves

Built - In Functions
Process PI for Draw, Tension, Winder and Unwinder Control Droop Control for Load Balance or Iron Process Helper Roll

iV series
T-N Curve
T 150%

Torque Characteristics

Torque ramp with zero speed


T 150% Speed[rpm]

100%
75% 0 rpm

50%
-150% 0

1500

3600 Speed[rpm] Time[0.5sec/div]

* Test Sample : 10HP, 220V

iV series
PLC Interface

Interface Options

RS232/485 Interface

120Volt Control Interface

CAN Interface

Multi-function Interface