Sunteți pe pagina 1din 11

OSMOTIC FRAGILITY OF RED BLOOD CELLS

OSMOTIC FRAGILITY TEST


DEFINITION - it is a test that measures the resistance

to hemolysis of red blood cells (RBC) exposed to hypotonic solutions RBC are exposed to a series of saline (NaCl) solutions with increasing dilution The sooner hemolysis occurs, the greater is osmotic fragility of RBC

Isotonic (physiological) solution 0.9 % NaCl RBC burst in hypotonic (< 0.9 % NaCl), and shrink (crenate) in hypertonic solutions (> 0.9 % NaCl) In hypotonic medium a membrane rupture occurs, allowing hemoglobin (Hb) to exit from the cells By measuring Hb concentration, the % of hemolysis at different NaCl concentrations can be calculated

NORMAL RANGE: - hemolysis onset at: 0.45-0.5 % NaCl - hemolysis complete at: 0.3-0.33 % NaCl

FACTORS AFFECTING OSMOTIC FRAGILITY - cell membrane permeability - surface-to-volume ratio

INCREASED OSMOTIC FRAGILITY - Hereditary spherocytosis - Acquired spherocytosis

Hereditary spherocytosis is a disorder characterized by a defective RBC membrane and decreased surface-tovolume ratio Characteristic round cells (spherocytes) are seen in blood smear and they are more fragile and break open in less hypotonic solutions than normal red blood cells

In hypotonic solutions water enters red blood cells Therefore, normal RBC with a biconcave shape swell and expand their volume On the other hand, spherocytes cannot absorb much extracellular liquid and break very easily

www.marvistavet.com

DECREASED OSMOTIC FRAGILITY - Thalassemia - Sickle cell anemia - Iron deficiency anemia

PROCEDURE
We use human erythrocytes that were washed with physiologic solution and thus do not contain plasma Label 5 eppendorf microtubes 15 and pipette 1 ml of the following solutions into them:
tube 1 physiological solution (non-diluted) tube 2 physiological solution diluted with water in the ratio 3:1 tube 3 physiological solution diluted with water in the ratio 2:1 tube 4 physiological solution diluted with water in the ratio 1:1 tube 5 physiological solution diluted with water in the ratio 1:5, containing NH4Cl (NH4Cl disables remaining membrane pumps)

Pipette 50 l erythrocyte suspension into each microtube, gently mix and let stand for 10 minutes. Then centrifuge 3 minutes at 3 000 g and carefully collect the supernatants for hemoglobin assay Prepare five glass test tubes 15 with 2 ml Drabkin reagent. Add 50 l of each supernatant from the previous step into the corresponding glass test tube and mix gently. Measure the absorbances of all the samples at 400 nm against blank containing the Drabkin reagent only.

Due to the fact that the blood sample is not fresh, we observe partial hemolysis even in test tube 1. The amount of hemoglobin determined in this test tube represents the control value and should be subtracted from the values obtained for all the tubes. The value of hemoglobin measured in test tube 5 is the maximum obtainable amount and we express it as 100% hemolysis. On this basis, calculate the percentage of hemolysis in test tubes 24. Using a calibration graph, express your results as the hemoglobin concentration in mg/l.