Sunteți pe pagina 1din 57

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS(V2) System Architecture

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

OBJECTIVES
To know the system capacity of ZXG10- Base Tranceiver Station Version 2 To understand the parts and functions of the ZXG10-BTS V2 To discover important features and technologies of ZXG10 BTS V2

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

GSM SYSTEM
GENERAL NETWORK ARCHITECTURE
MS
MS

(Mobile Station)

BTS

BSS (Base Station System)


BSC
PSTN, ISDN...

MSC

Voicemail Server SM-SC VLR


OMC

NSS
HLR AuC
OMC

(Network Switching Subsystem)

EIR

NMC

OMM(Operations & Maintenance GSM interfaces Management) X.25 links www.univ.zte.com.cn

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10 BSS STRUCTURE


Um

BTS
B I E

Abis
B I E

Q3

MS BSC
Ater

OMC-R

A
SM TC

BTS

SM

MSC

BS Interface

Gb

SGSN

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS HARDWARE PRINCIPLE


Abis Interface Um Interface

Data Link

B S C

Modulated Signal Demodulated Signal Control signal System Clock

A
RF Signal

M
U
System Clock

P
U

F
U

P
U

PDU
ZTE University www.univ.zte.com.cn
The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS HARDWARE CONFIGURATION

TRM 1

MMI
Abis

CMM

. . . .

BSC

PDM

TRM 6
. . . .

A E M

Um

FCM

TRM 12

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS HARDWARE CONFIGURATION


MAIN MODULES OF ZXG10 BTS V.2
1. CMM:Controller & Maintenance Module
2. TRM:Transceiver Module

3. AEM:Antenna Equipment Module


4. 5.
ZTE University

FCM:Fan Control Module PDM:Power Distribute Module


www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS HARDWARE CONFIGURATION

MAIN MODULES OF ZXG10 BTS V.2


CONTROLLER AND MAINTENANCE MODULE POWER DISTRIBUTION MODULE TRM TPU Tranceiver Processing Unit RCU Radio Carrier Unit PAU Power Amplifier Unit CDU Combiner Distribution Unit RDU Receiver Distribution Unit CEU Combiner Extension Unit FAN CONTROL MODULE
www.univ.zte.com.cn

AEM

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS HARDWARE CONFIGURATION

PDM

CMM CMM

PDM
C D U
S T R G S T R G S T R G S P A G

CMM

CMM
FCM
S T R G S C P D A G U S C P D A U G S C P D A U G

FCM
C T T T T C D R R R R D U M M MM U

FCM
C D U C D U T T T T C R R R R D M M M M U C D U C D U

FCM
S S P T A R G G S S P T A R G G

FCM
T T T T C R R R R D M M M M U

FCM

Single Rack Figure

40 W ZTE University

80 W www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS HARDWARE CONFIGURATION EXPANSION

S444

S888

S12/12/12

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS HARDWARE CONFIGURATION EXPANSION


BTS#3 BTS#1
CMM PDM CMM FCM C D U C D U T R M T R M T T R R M M C D U C D U FCM T T R R M M T T R R M M C D U PDM CMM

BTS#2
CMM

CMM PDM CMM FCM C D U T R M T R M T T R R M M

FCM C D U T R M T R M T T R R M M C D U C D U T R M

FCM T R M T T R R M M C D U C D U

FCM T T R R M M T T R R M M C D U

FCM C D U T R M T R M T T R R M M C D U C D U T R M

FCM T R M T T R R M M C D U C D U

FCM T T R R M M T T R R M M C D U

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

CMM HARDWARE

Indicator Light Test

Reset

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

CMM MODULE FUNCTIONS

1. BS interface functions 2. Providing various clocks needed by BS 3. Remote operation & maintenance function of BTS 4. Local operation & maintenance functions of BTS

5. Equipment alarm collection


6. Active/standby hot backup

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

CMM MODULE STRUCTURE


BS interface unit Switching unit Line interface BS interface Relay array Clock unit

Abis

TO TRM

CLK-ref

CLK Master/slave interface unit MMI unit Main controller unit

Environment monitoring unit

Power supply unit

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

EXTERNAL INTERFACES OF CMM (1)

Abis interface Data/clock interface between the rack at the same site Data/clock interface inside a rack (from CMM to TRM) Test interfaces Panel interface

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

EXTERNAL INTERFACES OF CMM (2)

External environment monitoring interface

Active/standby interfaces
MMI

Power interface
Site ID collection interface

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

DIPSWITCH OF CMM (1)

15 14 13 12 11 10

8 7

3 2

INDOOR SYN CHANEL_NO BTS_NO SLAVE1_PORT SLAVE2_PORT SATE ABIS_PORT

ABIS_TS

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

DIPSWITCH OF CMM (1)


INDOOR: type of BTS (0-indoors, 1-outdoors) SYN: Network synchronization reference clock source (0-clock extracted from the E1 interface, 1-SDH synchronization clock) CHANEL_NO: selection of on-site monitoring equipment ports (00-RS232 interface used to connect the transparent path, 01-RS422 interface used to connect the transparent path, 10-RS232 interface used to connect the main control unit) BTS_NO: rack No. in the same site (00-master rack, 01-slave rack 1, 10-slave rack 2) SLAVE1_PORT: master rack E1 port used to connect slave rack 1 (00-master rack C port, 01-master rack D port, 10-master rack E port, 11-master rack F port)

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

DIPSWITCH OF CMM (2)

SLAVE2_PORT: master rack E1 port used to connect slave rack 2 (00-master rack C port, 01-master rack D port, 10-master rack E port, 11-master rack F port)

SATE: whether to use the satellite Abis link (0 indicates the ordinary Abis, and 1 indicates the satellite Abis)
ABIS_PORT: O&M port No. (00-port A, 01-port B, 10-port C, 11-port D) ABIS_TS: O&M LapD timeslots on Abis interfaces (000-Ts16, 001-Ts31, 010-Ts30, 011-Ts29, 100-Ts28, 101-Ts27, 110-Ts26, 111-Ts25);

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

TRM INTRODUCTION (1)


TRM

Indicator light

Transmitter

TX

handle

Receiver Reset
RST RX RXD

Diversity Receiver

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

TRANCEIVER MODULE 40W and 80W

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

TRM INTRODUCTION (2)


Downlink Signal

PAU TPU RCU


Check Signal

AEM
Antenna

Uplink Signal

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

TRM PANEL DESCRIPTION

Category

Working band
GSM900 or EGSM900 GSM1800 GSM900 or EGSM900 GSM1800

Name
TRMG TRMD STRG SPAG STRD SPAD

Description
It works in GSM900 or EGSM900 band It works in GSM1800 band It works in GSM900 or EGSM900 band It works in GSM900 band It works in GSM1800 band

TRM (40W)

TRM (80W)

TRM (80W)

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ANTENNA EQUIPMENT MODULE (AEM)

Tx
TRM GROUP

AEM
Rx RxD

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ANTENNA EQUIPMENT MODULE TYPES

Combiner Distribution Unit (CDU) D Combiner Distribution Unit (DCDU) E Combiner Distribution Unit (ECDU) Combiner Extension Unit (CEU) Receiver Distribute Unit (RDU)

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF CDU (1)


LNA_Splitter Duplexer ANT Cable Alarms RTE forward reverse optional VSWR_meter Cable Rx_in ERX1 ERX2 RX1 RX2 RX3 RX4

Tx_out 50ohm

TX1 TX2

Alarms

Hybird_combiner

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF CDU (2)


CDU (Combiner Distribution Unit)
CDU
TX1 TX2 Test Port Indicator TEST Antenna ANT
RX1 RX2 RX3 RX4 EX1 EX2

Combiner Input

Ext Receive

1 to 4 Divider

2 to 1 Combiner
Divider Output Divider Ext Output

D U P L E X E R

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF DCDU
LNA_Splitter RX1 Duplexer Cable ANT Cable RX2 Rx_in

Alarms forward RTE reverse optional VSWR_meter

ITX

Alarms

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF ECDU

LNA_Splitter Duplexer ANT Cable Cable RTE Alarms ITX Rx_in RX1 RX2

forward

reverse

VSWR_meter Alarms

optional

LNA_Splitter ANTD Rx_filter Cable Rx_in

RXD1 RXD2

Alarms

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF RDU (1)

Rx_filter ANT Cable Rx_in

LNA_Splitter

ERX1 ERX2 RX1 RX2 RX3 RX4

50ohm Alarms RTE

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF RDU (2)


RDU (Receiver Distribution Unit)
RDU
Ext Receive

Antenna

1 to 4
Divider
ANT
RX1 RX2

Divider Output

Indicator

RX3 RX4 EX1

EX2

Divider Ext Output

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF CEU (1)


Rx_Splitter ERX1 ERX2 RX1 RX2 RX3 RX4

To CDU TX1 50ohm Hybird_combiner

TX1 TX2

To CDU TX2 50ohm Hybird_combiner

TX3 TX4

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTRODUCTION OF CEU (2)


CEU (Combiner Extension Unit)

Combiner Input

TX1 TX2

CEU
Indicator

1 to 2 Divider 1 to 2 Divider 2 to 1 Combiner 2 to 1 Combiner


Divider Ext Output

Combiner Output

OTX1 TX3 TX4 OTX2 RX1


RX2 RX3 RX4 EX1 EX2

Divider Output

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS V.2 AEM CONFIGURATION Sum of Carrier (one cell) Sum of CDU Sum Of CEU Sum of Carrier (one cell) Sum of CDU Sum of CEU

1 2 3 4

2 2 2 2

0 0 0 0

7 8 9

2 2 4

2 2 1

10
11 12

4
4 4

1
2 2

5 6
ZTE University

2 2

1 1

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS V.2 BASIC CONFIGURATION

TX/RX

TX/RX

CDU
TX1 TX2 RX1 RX2 RX3 RX4

CDU
TX1 TX2 RX1 RX2 RX3 RX4

O4
TX RX RXD TX RX RXD TX RX RXD TX RX RXD

TRM1

TRM2

TRM3

TRM4

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS V.2 BASIC CONFIGURATION

TX/RX

TX/RX
RX1 RX2 RX3 RX4 TX1 TX2

CDU
TX1 TX2

RX1 RX2 RX3 EX1 EX2 RX4

CDU
EX1 EX2 EX1 EX2

O8

OTX1 OTX1

CEU

EX1

EX2

OTX1 OTX1

CEU

TX1TX2 TX3 TX4 RX1 RX2 RX3 RX4

TX1TX2 TX3 TX4 RX1 RX2 RX3 RX4

TX

RX RXD

TX

RX RXD

TX

RX RXD

TX

RX RXD

TRM1

TRM2

TRM5

TRM6

TX

RX RXD

TX

RX RXD

TX

RX RXD

TX

RX RXD

TRM3

TRM4

TRM7

TRM8

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS V.2 BASIC CONFIGURATION


TRM1 TRM2 TRM3 TRM4
TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD

TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4

OTX1 OTX2 C E U EX1 EX2

TX1 TX2 RX1 RX2 RX3 RX4 EX1 EX2

TX/RX C D U

TRM5 TRM6 TRM7 TRM8

O10

TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4

OTX1 OTX2 C E U EX1 EX2

TX1 TX2 RX1 RX2 RX3 RX4 EX1 EX2

TX/RX C D U

TRM9

TRM10

TX1 TX2 RX1 RX2 RX3 RX4 EX1 EX2

TX/RX C D U

TX/RX RX1 RX2 RX3 RX4 EX1 EX2 R D U

ZTE University

Notes: use two pairs of polarized antenna

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS V.2 BASIC CONFIGURATION


TRM1 TRM2 TRM3 TRM4
TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD TX RX RXD

TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4

OTX1 OTX2 C E U EX1 EX2

TX1 TX2 RX1 RX2 RX3 RX4 EX1 EX2

TX/RX C D U

TRM5 TRM6 TRM7 TRM8

TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4

OTX1 OTX2 C E U EX1 EX2

TX1 TX2 RX1 RX2 RX3 RX4 EX1 EX2

TX/RX C D U

O12

TRM9 TRM10 TRM11 TRM12

TX1 TX2 RX1 RX2 RX3 RX4 EX1 EX2

TX/RX C D U

TX1 TX2 RX1 RX2 RX3 RX4 EX1 EX2

TX/RX C D U

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

FAN CONTROL MODULE FUNCTIONS

Temperature monitoring Fan control and inspection

Communication with TRM

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

FAN CONTROL MODULE FUNCTIONS

Optical coupling isolation

Temperature 1 alarm Temperature 2 alarm

Fan drive

PWM

Optical coupling isolation

Fan control

Fan alarm CPU alarm

CPU

Fan 1 rotation speed Fan 2 rotation speed

Monitoring circuit

Temperature 1 Temperature 2

From TRM +12V

+5V Power supply 1


Power supply 2

From RRM

-48V or +24V

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

PDM POWER SUPPLY MODULE

PDM

CMM backplane

FCM

Backplane of the carrier shelf

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

BTS V.2 POWER CONSUMPTION

TRM: 140W AEM: 70W CMM(2): 20W Fans and others: 80W One frame when full configuration: 700W One rack when full configuration2200W

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

TOP CONFIGURATION
1 2 3 4 5 6 7 8 9 10 11

15

16 12 17 13 14

18 19

1: PE 2: PWRTA_L1 3: PWRTA_L2 4: PWRTA_L3 5: 13MHz 6: FCLK 7: RS232 8: E1 PORT 9: RELAY_ALM 10: ID PORT 11: SYNC 12: HYCOM3 13: HYCOM2 14: HYCOM1 15: GND 16: HYCOM6 17: PWR 18: HYCOM5 19: HYCOM4

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

INTERFACE AND COMMUNICATION


M Interface

External Monitoring System


B Interface

Um Interface

BSC

Abis Interface MMI Interface Interface of the tower amplifier system

Tower Mounted Amplifier

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

FRAME STRUCTURE OF Abis INTERFACE

11 multiplexing
TS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 0 1 2 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 3 4 5 SYNC TRX1 TCH1 TCH2 TCH5 TCH6 TRX2 TCH1 TCH2 TCH5 TCH6 TRX3 TCH1 TCH2 TCH5 TCH6 TRX4 TCH1 TCH2 TCH5 TCH6 TRX5 TCH1 TCH2 TCH5 TCH6 O+M1 TRX6 TCH1 TCH2 TCH5 TCH6 TRX7 TCH1 TCH2 TCH5 TCH6 TRX8 TCH1 TCH2 TCH5 TCH6 TRX9 TCH1 TCH2 TCH5 TCH6 O+M4 O+M3 O+M2 6 7 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7

SYNCSynchronous time slot

TRXLAPD signaling channel of radio carrier OMULAPD channel of OMU, mainly includes configuration and O&M information of all BTSs

TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4

TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7

TCHTraffic channel, occupying 2 bits, 16kb/s

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

FRAME STRUCTURE OF Abis INTERFACE

14 multiplexing
TS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 0 1 2 TRX1 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TRX5 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TRX9 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 TCH0 TCH4 3 4 5 SYNC TRX2 TRX3 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 TRX6 TRX7 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 O+M TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 TRX10 TRX11 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 TCH1 TCH2 TCH5 TCH6 O+M4 O+M3 O+M2 6 7 TRX4 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TRX8 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TRX12 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7 TCH3 TCH7

SYNCSynchronous time slot

TRXLAPD signaling channel of radio carrier OMULAPD channel of OMU, mainly includes configuration and O&M information of all BTSs

TCHTraffic channel, occupying 2 bits, 16kb/s

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10 BTS VERSION 2 NETWORK

Site 0

BSC

.
. .

Site 1

Site n

The star networking mode


ZTE University www.univ.zte.com.cn
The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10 BTS VERSION 2 NETWORK

BSC
Site 0 Site 1 Site 2

Schematic diagram of chain networking

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10 BTS VERSION 2 NETWORK


Site 1

Site 2

.
BSC . .
Site n Site 0 Site 3

Tree Networking Mode


ZTE University www.univ.zte.com.cn
The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS (V2) INTERNETWORKING

B T S B T S

B T S

MSC

BSC
B T S B T S

B T S

B T S B T S

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZXG10-BTS (V2) LINK PROTECTION

A B

BSC
B D B

BTS

BTS

BTS

High reliability key components adopt redundancy and backup technology Adopt the BCCH carrier automatically rearranging technology to improve the system reliable BTS support the automatic skip connection protection function for linkconnection mode ZTE University www.univ.zte.com.cn
The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

SHELTER BTS

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

SHELTER BTS SPECIFICATIONS


The ZXG10 SBTS normally holds the ZXG10-BTS(V2) rack and matched device, so the ZXG10 SBTS supports all the features of the ZXG10-BTS(V2). It can hold 1, 2 or 3 ZXG10-BTS(V2) racks respectively. The largest capacity is 36 TRXs. The shelter of the ZXG10 SBTS can also contain the ZXG10-BSC and the ZXG10BTS(V2) simultaneously.

Standard configuration consists of two accumulator sets with a total capacity of 400 AH (Max. 800AH). This configuration ensures a power supply of 4~8 hours.
ZTE University www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

SHELTER BTS SPECIFICATIONS

The ZXG10 SBTS provides integrated power and environment monitoring system and the monitor of the base station system involves no additional transmission resource. The Shelter may be applied in transmission of Microwave, SDH, PDH, and other modes of transmission.
Two conditioners mounting on the wall work in timed shifts. This secures an operation temperature of 25 C 5C.

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

SHELTER BTS FLOOR LAYOUT

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

ZTE University

www.univ.zte.com.cn

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

S-ar putea să vă placă și