Sunteți pe pagina 1din 17

INTRODUCING

OUR NEW
PRODUCT
SYSMEX XE 5000
A BRIEF INTRODUCTION
The Sysmex XE-5000 Automated Hematology System utilizes the
power of fluorescent flow cytometry and hydrodynamic focusing
technologies.
Using a unique and advanced diode laser bench, Sysmex fluorescent
flow cytometry provides the sensitivity needed for measuring and
differentiating cell types in whole blood and body fluid samples.
Fluorescent technology and hydrodynamic focusing enable the XE-
5000 to consistently differentiate normal WBC, RBC and PLT
populations from abnormal populations, thereby decreasing the
number of manual interventions.
The XE-5000 technology provides clinically relevant and reportable
parameters.
Reportable parameters
43 parameters
CBC (14 parameters)
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MPV, P-
LCR, PDW, PCT
DIFF (12 parameters)
NEUT%, LYMPH%, MONO%, EO%, BASO%, IG%, NEUT#, LYMPH#,
MONO#, EO#, BASO#, IG#
NRBC (2 parameters)
NRBC%, NRBC#,
RET (8 Parameters)
RET%, RET#, LFR, MFR, HFR, IRF, RET-He, IPF, (PLT-O)
Body Fluid (6 parameters)
WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#
-HPC

SPECIFICATIONS
Principles & Technologies
Fluorescent Flow Cytometry:
WBC-Di, IG, NRBC, RET, IRF, PLT-O
RF-DC method:
HPC
DC-Sheath-Flow:
PLT, RBC, HCT
SLS-Method:
Hgb
Linearity WBC: 0 440.00 x 103
/L
RBC: 0 8.00 x 106
/L
PLT: 0 5,000 x 103
/L
Body Fluid Linearity WBC-BF: 0.000 10.000 x 103
/L
TC-BF: 0.000 10.000 x 103
/L
RBC-BF: 0.000 5.000 x 106
/L
SPECIFICATIONS
Throughput Whole Blood Mode:
150 samples/hr (max.)
Body Fluid Mode:
38 samples/hr (max.)
Sample Volumes 200L / 130L (manual closed
mode/open mode)
40L for capillary mode
Data Storage
(IPU: Information Processing Unit)
10,000 samples (incl. graphics)
Interfaces Sysmex WAM (HL7 & ASTM)
SPECIFICATIONS
Quality Control (Total QC Management) Levey-Jennings control chart
X-bar M le
Online QC
Dimensions / Weight
w x h x d [in] / [lbs]
Main unit: 27.8" x 35.9" x 28" / 178 lbs.
Sampler: 22.8" x 7.7" x 14.8" / 26 lbs.
IPU: 18" x 17.6" x 5.3" / 24 lbs.
Congurations Stand alone
Sysmex HST-N, Sysmex XE-AlphaN
TARGET CUSTOMER
SUITABLE FOR LAB WHICH RECEIVES
GREATER NUMBER OF SAMPLES PER DAY
SUITABLE FOR LAB WITH LESS STAFFS AS
OUR ANALYZER IS AUTOMATED AND
REQUIRES LESS MANPOWER.


XE-5000 ANALYSIS PRINCIPLE
Laser Flow Cytometry
ShealthFlow/Hydrodynamic Focusing DC
detection
RF/DC Detection Method
SLS Heamoglobin Method

FLUOROSCENCE FLOW CYTOMETRY

DC-HYDRODYNAMIC FOCUSING

XE-5OO0 MULTICHANNEL ANALYZER
CHANNEL PRINCIPLE PARAMETERS
WBC/BASO Flow cytometry WBC,Baso #, Baso
NRBC Flow cytometry NRBC #, NRBC %
4 Diff Flow cytomtery Lymph# , Lymph%
Mono#, Mono%
Eo# , Eo%
Neut# , Neut%
IG# , IG%
RET/PLT-O Flow cytometry RET#, RET%,PLT-O,
HFR, MFR, LFR, IRF
RET-He, IPF
IMI RF/DC-detection
method
HPC#
HGB SLS-Method,
photometry
HGB
MCH,MCHC,MCV
RBC/PLT-Detector HDF DC-Detection
method
RBC,HCT,PLT-I,RDW-
SD, RDW-CV, PDW,
MPV, P-LCR
REAGENT SYSTEM
OUTPUT
WHY SYSMEX XE-5000??
Integrated Sysmex SP-Series automated
slide maker/stainer.
eMM software provides more specific
flagging.
Measure body fluids.
Advanced parameters


WHY SYSMEX XE-5000 ?
HIGH THROUGHOUTPUT
NO NEED OF SAMPLE PREPARATION
SHORTENED TURN AROUND TIME
REDUCED SAMPLE VOLUME
LESS LIKEHOOD OF TRANSCRIPTIONAL ERRORS
PROVIDES 7 SCATTERGRAMS AND 2
HISTOGRAM FOR A BETTER ANALYSIS
RANKED BY THIRD PARTY AS HIGHEST VENDOR
FOR RELIABILITY FOR 8 CONSECUTIVE YEARS IN
A ROW*




CUSTOMER SERVICE
In-time deliveries of reagents and
consumable
Instrument repair and maintenance including
hot-line support
Consultancy and management of complex
laboratory installation projects
Continuous post-market surveillance and
feedback of market requirements as design
input for new product development
Management of customer events

S-ar putea să vă placă și