ASOKORO
Client: Chief Arthur Eze
Prepared by
Kosi Emmanuel Chukwujindu (Arc.)
For Geometrix Consultants and Builders ltd.
No. 23 Waziri Ibrahim Crescent Gudu, Abuja.
July 2014
CONTENTS
Introduction
Brief
Site Analysis
Design principles
Proposed Siteplan
Proposed Floor-plans
Perspective views
Animated walkthrough.
PROJECT INTRODUCTION
This is a presentation of our initial design submission. Hope you like it.
THE BRIEF
An Architectural brief is a statement of a client's requirements, which form the basis for
appointing an Architect. The brief describes the requirements that need to be reconciled and
accommodated,
THE SITE
AREA = 20,600 SQ. M (2.06 HCT.)
THE SITE
AREA = 20,600 SQ. M
(2.06 HCT.)
LOCATION
MAP
SUN DIRECTION
WIND
According to Geographical data available, the site will be affected by two main
winds i.e. the North East Trade Wind (N-E) and the South West Trade Wind
(S.W). As such the building has been positioned to take maximum advantage of
both winds.
SLOPE
Preliminary inspection of the site revealed that the site had a gentle slope
originating from the South-East border and tending toward the North-West
Border. This appreciable difference in spot heights will allow for easier drainage
of mechanical services. It also dictates that all drainage must tend toward the
North-West Boundary of the Site.
DEVELOPMENT CONTROL REQUIREMENTS
BUILDING SETBACK
The development control Authority stipulates a minimum building setback of
4m from the fence line to the building line and 6m where there is a road. This
standard was met in the planning of the Proposed Hotel as shown left- below.
HEIGHT RESTRICTIONS
The development control Authority stipulates a MAXIMUM OF 4 suspended
floors for tall developments within the Asokoro Area. This standard was met in
the planning of the Proposed Hotel as shown right- above.
DESIGN PRINCIPLES
EASE OF CIRCULATION
The provision of
inter-connecting
corridors and
lobbies, which
lead to stairs and
lifts form a
network of easily
accessible system
throughout the
building.
DESIGN PRINCIPLES
USER SAFETY
The provision of
ESCAPE stairs at every
node allows for easy
evacuation of users in
the event of a crisis
situation. The
maximum distance
from each node to
anywhere on a floor is
always less than 30m.
DESIGN PRINCIPLES
ROOM ARRANGEMENT
The USE of Glass and Modern Cladding Material for Beauty and
Durability speaks for itself.
DESIGN PRINCIPLES
OPENESS OF RESTAURANT, LOUNGE AND BAR SPACES AND SIT-OUTS
Delivery
Supply
Staff entrance
TERRACE 5m x 5m comfy 4 16
BEDROOMS with private
balcony
PRESIDENTIAL 15m x 5m 2 2
SUITE(75sq.m) comfy with
lounge and two
bedrooms
STANDARD
BEDROOM
152 NOS.
SUITE -
BEDROOM
12 NOS.
TERRACE
BEDROOM
16 NOS.
Collapsible to
PRESIDENTIAL three single
SUITE bedrooms in
(2 NOS)
case of heavy
demand.