Sunteți pe pagina 1din 54

CISCO NX-OS DATA

CENTER FEATURES
Jack Ross
CCIE #16728
1
Agenda
Brief Hardware Overview
Software Versions
NX-OS Layer 2
NX-OS Layer 3
FabricPath
Virtual Device Contexts (VDCs)
Fiber Channel Over Ethernet (FCoE)
Overlay Transport Virtualization (OTV)
Virtual Port Channels (vPCs)




2
Nexus 7000 Overview
Nexus 7000/7700
Typically DC core or aggregation
High performance, density, & availability
Unified I/O
FCoE switch but not a FC switch
Redundant Power, Line Cards and Supervisors
3
Nexus 7000 Platform Overview
Currently 7 form factors
7018, 7010, 7009, 7004, 7718, 7710,7706
Currently 2 types of line cards
M Series Cards - Layer 3 cards
Feature rich cards
F Series Cards - Layer 2 cards*
Performance oriented cards
4
Line Card Features
M Series Specific
Layer 3 Routing
FEX
OTV
TrustSec
F Series Specific
FabricPath
vPC+
FCoE
5
Nexus 5000 Overview
Nexus 5000/5500
Typically End of Row (EoR) aggregation or Top
of Rack (ToR) access
Typically Layer 2 but can do limited Layer 3 with add on
daughter card in the 5500 Series
Unified I/O
Both FCoE and native FC switching
Redundant power but not supervisors

6
Nexus 5000 Platform Overview
Currently 2 Generations
1st Gen - Nexus 5000 5010 & 5020
2nd Gen - Nexus 5500 5548 & 5596
Mainly layer 2 switching
5500 can support L3 add-in card
Supports Unified I/O
Both FCoE Forwarder (FCF) and native FC switching
5500 supports Unified Ports (UP models)
Ports can run as Ethernet or native Fibre Channel
Ethernet ports allocated at port 1 and counts up
Fibre Channel ports allocated at last port and counts down
Requires a reboot to re-allocate ports role (like UCS FI)
7
Nexus 2000
Fabric Extender (FEX)
Acts as a remote line card of 7K or 5K chassis
All management performed on Parent Switch
No console or VTY ports on FEX
NX-OS automatically downloaded from Parent
No local switching
Essentially a VN-Tag/802.1BR switch, not an Ethernet
switch
Traffic between local ports on FEX must flow north via
uplink to Parent and then south back down
Can impact design decision of platform placement
8
Software Versions for CCIE Lab
NX-OS v6.0(2) on Nexus 7000 Switches (6.2(6) latest)
NX-OS v5.1(3) on Nexus 5000 Switches
NX-OS v4.2(1) on Nexus 1000v
NX-OS v5.2(2) on MDS 9222i Switches
UCS Software release 2.0(1x) for UCS-6248
Fabric Interconnect

9
Nexus NX-OS Basics
Nexus at its core is a Layer 2/3 Switch
Similar in many aspects to Catalyst IOS
VLANs, Trunking, VTP, Rapid PVST, MST,
EtherChannel, PVLANs, UDLD, FHRPs, IGPs,
BGP, etc.
Key new features beyond Catalyst IOS
FEX, vPC, Fabric Path, OTV, FC Switching, FCoE, etc
10
NX-OS Port Channels/EtherChannels
Unlike IOS, NX-OS does not support PAgP
Channels must be statically on or LACP negotiated
no switchport mode desireable
LACP must be enabled with feature lacp
One of the killer apps of NX-OS is
Virtual Port Channels (vPC)
Multi-Chassis EtherChannel (MEC/MCEC)
Analogous to 3750 Cross StackWise Channel & 6500
Virtual Switching System (VSS)
11
NX-OS Spanning Tree
Unlike IOS, NX-OS does not support legacy CST/PVST+
Default STP mode is Rapid-PVST+
i.e. per-VLAN, but uses 802.1w Rapid STP
Also supports 802.1s Multiple Spanning Tree (MST)
NX-OS defines three STP port types
spanning-tree port-type [normal | edge | network]
12
NX-OS Switchport Types
spanning-tree port-type normal
Normal ports act like Catalyst IOS ports
Default STP port type, run Rapid Per VLAN STP
spanning-tree port-type edge
Edge ports are STP PortFast ports
spanning-tree port-type network
Network ports run STP Bridge Assurance
13
Bridge Assurance
All STP Network Ports send BPDUs regardless of STP port state
Legacy 802.1d only sends BPDUs from Root Bridge
downstream
Primary goal is to protect against unidirectional links
BPDU becomes a bidirectional keepalive
Replaces LoopGuard functionality
Secondary result is same functional effect as VTP Pruning
VLANs stop forwarding on trunk links that you do not receive
BPDUs for that VLAN in
Enabled on interfaces with spanning-tree port type network
14
Bridge Assurance Diagram
15
N5K-1
N5K-2
VLANS 10, 20, 30
VLANS 20, 30, 40
10
20
30
20
30
40
20, 30
Bridge Assurance
switchport trunk allowed vlan
NX-OS Layer 3
Like Catalyst IOS, NX-OS supports
Native layer 3 routed interfaces
I.e. no switchport
Switched Virtual Interfaces (SVIs)
I.e. VLAN interfaces
Must be enabled with feature interface-vlan
16
NX-OS Routing Protocols
Like IOS, NX-OS supports routing with
Static routing
RIPv2 & RIPng
EIGRP & EIGRPv6
OSPF & OSPFv3
IS-IS
BGP
Policy Routing
No network command in IGPs, activated on link
Not all protocols use the same license

17
NX-OS VRF
Like IOS, NX-OS Virtual Routing & Forwarding Instances are
used to create separate logical routing tables
Layer 3 interfaces in different VRFs cannot exchange traffic
by default
NX-OS VRFs behave slightly different than IOS, as
All layer 3 interfaces are automatically in VRF table default
MGMT0 is automatically in vrf management
VRFs are defined as vrf context
Static routes are defined under the vrf context
Dynamic routing is VRF aware, but configured under the
same process
Exec mode routing-context vrf can change the default VRF
for verifications
18
NX-OS Redistribution
Unlike IOS, route-maps are required to perform
redistribution on NX-OS
Same route-map match/set logic as IOS
Redistribution does not include directly connected
interfaces
Requires redistribute direct route-map
19
Fabric Path
Pre Standard version of TRILL
Essentially Layer 2 Ethernet Routing
Uses ISIS to route Layer 2 Frames instead of using STP
Can build arbitrary Topologies Full Mesh, Partial Mesh,
Triangle, Square, etc
Adds a TTL in Layer 2
When using with vPC referred to as vPC+

20
Fabric Path Configuration
Very few commands necessary
Enable FabricPath
install feature-set fabricpath
feature-set fabricpath
Configure FabricPath VLANs
mode fabricpath under VLAN
Configure FabricPath Core Ports
switchport mode fabricpath
21
Virtual Device Contexts (VDC)
VDCs used to virtualize physical hardware of Nexus 7000
Loosely analogous to SDRs in IOS XR or Contexts in ASA
VDCs also virtualize control plane protocols of Nexus 7000
Not analogous to VLANs or VRFs in IOS
Separate control plane per VDC

VLAN 40 in VDC 1 is not VLAN 40 in VDC 2
OSPF PID 20 in VDC 1 is not OSPF PID 20 in VDC 2
22
Why VDCs?
Multiple logical roles per physical chassis
E.g. Core & Aggregation/Distribution on same box

Multi-Tenancy
E.g. VDCs as a managed service to customers

Test Lab Environment for later Production Use
Required for certain features FCoE/Storage
23
VDC Caveats
Some features cant co-exist in same VDC
OTV and VLAN interfaces (SVIs)
F2 cards and M1/F1
FCoE requires its own Storage VDC

Hardware and Software version dependent, check the
release notes
24
VDC Maximums
4 VDCs per chassis with SUP 1
4+1 VDCs per chassis with SUP 2
8+1 VDCs per chassis with SUP 2E*
No internal cross VDC communication
E.g. no route leaking like in VRFs
Physical cable can be used to connect VDCs
25
The Default VDC
Default VDC 1 always exists and cannot be removed
Used to create and manage other VDCs
Controls VDC port allocations
All ports allocated to default VDC at initialization
Controls VDC resource allocations
Number of VLANs, VRFs, Routing table memory, etc.
Can be used for normal data plane operations
Recommended for management of chassis only
26
Default VDC Tasks
Some tasks can only be performed in the default VDC
VDC creation/deletion/suspend
Resource allocation interfaces, memory, MACs
NX-OS Upgrade across all VDCs
ISSU or EPLD Upgrade
Ethanalyzer captures control plane traffic
Feature-set installation for Nexus 2000, FabricPath, FCoE
Control Plane Policing (CoPP)
Port Channel load balancing hash
Hardware IDS check control
ACL Capture feature enable
System-Wide QoS
27
Converged Ethernet or FCoE
Lots of terms that essentially mean the
same thing
Unified Fabric
Unified Wire
Converged Ethernet
Converged Enhanced Ethernet
Data Center Ethernet
Data Center Bridging
What they all really mean
You are running the physical framing for both Ethernet and Fibre
Channel over the same physical links
28
FCoE Terms
FCoE Initialization Protocol (FIP)
FCoE Forwarder (FCF)
ENode End Device
Virtual Fibre Channel (VFC) Interface
29
FC, FCoE, FCIP and iSCSI
30
How FCoE Works
FCoE replaces layer 1 & 2 transport for FC
All upper layer FC services remain
Domain IDs, FSPF, FCNS, FLOGI, Zoning.
New FCoE Initialization Protocol (FIP) to negotiate
between Fabric and Node
Fabric is the FCF
Node is the ENode
31
FCoE Control and Data Planes
FIP is the control plane of FCoE
FCoE is the actual data plane
FIP
New EtherType 0x8914
Used to discover FCFs and perform FLOGI
_ UCS C when FCoE turned on uses LLDP to begin
negotiation
FCoE
New Ethertype 0x8906
Min length of 2240 bytes, FC has larger payload
Implies Jumbo Frames are required
32
OTV Basics
Overlay Transport Virtualization (OTV)
Layer 2 VPN over IPv4
Specifically OTV is
IPv4/IPv6 over Ethernet over MPLS over GRE
over IPv4

33
OTV vs. other Layer 2 DCIs
Layer 2 DCI is needed for Virtual Machine Workload Mobility i.e. VMware
VMotion

Many possible options for L2 DCI
Dark Fiber (CWDM/DWDM)
Layer 2 Transport Protocol (L2TPv3)
Any Transport over MPLS (AToM)
Virtual Private LAN Services (VPLS)
Bridging over GRE Spanning Tree Bridge Group

These options can be used for DCI, but OTV was made for DCI
Optimizes ARP flooding over DCI
Demarc of the STP domain
Can overlay multiple VLANs without complicated design
Allows multiple edge routers without complicated design
34
OTV Terms
OTV Edge Device
Edge router(s) running OTV
Authoritative Edge Device (AED)
Active edge router for a particular VLAN
Allows multiple redundant edge routers while
preventing loops
Extend VLANs
VLAN being bridged over OTV
Site VLAN
Internal VLAN used to elect AED
35
OTV Terms Continued
Site Identifier
Unique ID per DC site, shared between AEDs
Internal Interface
Layer 2 interface where traffic to be encapsulated is
received
Overlay Interface
The logical OTV tunnel interface that performs the OTV
encapsulation
OTV Join Interface
The Layer 3 physical link or port-channel that you use
to route upstream towards the DCI
36
OTV Overview
37
VLANS
10 - 70
Server 1
VLAN 60
Server 2
VLAN 60
OTV Overview
DCI
Any Layer 3
Connection
OTV Overlay
Logical Address
OTV Overlay
Logical Address
Join
Interface
Internal
Interface
Extend
VLANS
50 -70
Site
VLAN 4
VLANS
50 - 90
OTV Overlay
Logical Address
OTV Overlay
Logical Address
Site
VLAN 3
AED
VLANS
50 -59
AED
VLANS
60 - 70
VLANS
10 - 70
VLANS
50 - 90
NK7-1-2
NK7-1-1
NK7-2-2
NK7-2-1
OTV Control Plane
Uses IS-IS to advertises MAC addresses between AEDs
Is its own transport and extensible

ISIS Encapsulated as Control Group Multicast
IS-IS over Ethernet over MPLS over GRE over
IPv4 Multicast
Implies that DCI must support ASM Multicast
38
OTV Data Plane
Uses both Unicast and Multicast Transport
Multicast Control Group
Multicast or Broadcast Control Plane Protocols
E.g. ARP, OSPF, EIGRP, etc.
Unicast Data
Normal Unicast is encapsulated as Unicast between AEDs
Multicast Data Group
Multicast Data flows are encapsulated as SSM Multicast
Implies AEDs use IGMPv3 for (S,G) Joins
39
OTV Adjacency Server
Normally OTV requires that the DCI runs multicast
Needed to find and form IS-IS adjacencies and to tunnel
multicast data traffic
OTV Adjacency Server removes multicast requirement
One (or more) AEDs are configured as the adjacency
server
All other AEDs register with the adjacency server
Now all endpoints are known
All control and data plane traffic is now unicast encapsulated
Will result in Head End Replication when more than 2
DCs connected over the DCI
40
OTV DCI Optimizations
Other DCI options bridge all traffic over DCI
STP, ARP, L2 Flooding, broadcast storms, etc.

OTV reduces unnecessary flooding by
Proxy ARP/ICMPv6 Cache on AED
Terminating the STP domain on AED
41
vPC Port Channels

Port Channels, EtherChannels, & NIC Teaming/Bonding
terms used interchangeably
Regardless of vendor, 802.3ad (LACP) refers to Port Channeling

Used to aggregate bandwidth of multiple links between devices
E.g. 4 x physical 1GigE links form a 4GigE logical Port Channel

Appears as one logical link from STPs perspective
Avoids active/standby and allows active/active
42
vPC Port Channels
Data flows are load balanced between member links
Single flow cannot exceed BW of any physical member link
E.g. increases lanes on the highway but not the speed limit
Does not perform LFI like PPP Multilink

Flows are load balanced based on L2, L3, & L4 header
information
SRC/DST VLAN, MAC, IP, & TCP/UDP Port
Default is SRC/DST L3 for IPv4/IPv6 and SRC/DST MAC
for non IP
Can result in over/under subscribed links
43
Port Channels
Port Channeling was original between only 2 devices
1 downstream device & 1 upstream device
E.g. end host to Catalyst 3550 via 2 x FE links
Increases BW but still has single point of failure
Multi Chassis EtherChannel (MCEC/MEC) is between
3 devices
1 downstream device & 2 upstream devices
E.g. end host to 2 x Catalyst 3750s via 2 x GigE links
Increases BW and resiliency
Logically appears the same as a 2 device Port Channel
44
Multi Chassis Ethernet Channels
3750 StackWise & 6500 VSS single control plane
StackWise via Stacking Cable to connect BP
VSS via Virtual Switch Link (VSL)
vPC uses two separate control planes
Configurations managed independently
Separate control plane protocol instances
STP, FHRPs, IGPs, BGP, etc.
Synchronization via a Peer Link
Similar logic to VSSs VSL
45
vPC Peer Switches
vPC made up of 2 physical switches
The vPC Peers
vPC Peers each have
vPC Peer Link
vPC Peer Keepalive Link
vPC Member Ports
46
vPC Overview
47
N5K-1 N5K-2
N7K-1
N7K-2
Access Switch
Peer Link
Peer Keepalive
Member Ports Member Ports
vPC Peer Link
Layer 2 trunk link used to sync control plane between vPC peers
CAM table, ARP cache, IGMP Snooping DB, etc.
Uses Cisco Fabric Service over Ethernet (CFSoE) protocol
Used to elect a vPC Primary and vPC Secondary Role

Normally not used for the data plane
Peer Link generally much lower BW than aggregate of
vPC Member Ports
If Peer Link used in the data plane, it is the bottleneck
48
vPC Peer Keepalive
Layer 3 link used as heartbeat in the control plane
Used to prevent active/active or Split Brain vPC Roles
Not used in the vPC data plane
Uses unicast UDP port 3200
Peer Keepalive Link can be
Mgmt0 port
Back to back or over routed infrastructure
Ideally in an isolated VRF
49
vPC Member Ports
Data plane port channel towards downstream neighbor
Each vPC Peer has at least one member port per vPC
Can be more, up to hardware platform limits
From perspective of downstream neighbor, upstream
vPC Peers are one switch
Physical result is a triangle
Logical result is a point-to-point Port Channel with no
STP blocking ports
50
vPC Order of Operations
Enable feature vpc
Create a vPC domain
Configure the vPC peer keepalive link
Create the vPC peer link
Move member ports to a vPC
Configurations must be consistent to avoid Type 1 and
Type 2 errors
51
vPC Loop Prevention
Goal of vPC is to hide redundant links from STP
Could result in layer 2 flooding loops
Loops are prevented via vPC Check behavior
Frames received in the vPC Peer Link cannot flood out a vPC
Member Port while the remote vPC Peer has active vPC
Members in the same vPC
vPC Check Exception
If vPC Peers Member Ports are down, the
vPC Member Ports become Orphan Ports and the
vPC Check is disabled
vPC Peer Link is essentially a last resort connection
52
vPC and FHRP
Nexus 7000 is typically L2 & L3 network boundary
N7K is vPC Peer but also end hosts FHRP Default Gateway
FHRP behavior changes to accommodate active/active forwarding
over vPC
Traffic received in vPC Member Port of FHRP Standby to FHRP
Virtual MAC is not forwarded over Peer Link to Active FHRP member
Essentially HSRP Standby acts as HSRP Active
FHRP vPC can break in certain non-standard vendor applications
Frames sent to FHRP Standby with physical DST MAC of FHRP
Active are sent out the Peer Link
peer-gateway allows FHRP Standby to forward frames on
behalf of DST MAC of FHRP Active without going over Peer Link
53
vPC and Multicast

When source is reachable via vPC Member Port, both
vPC Peers act as PIM DR
Called Dual DR or Proxy DR

Allows either vPC Primary or Secondary to receive traffic
from source and forward it north without having to cross the
vPC Peer Link
Respects vPC check rule
54

S-ar putea să vă placă și