Sunteți pe pagina 1din 101

2008-05

www.huawei.com
HUAWEI Confidential
Security Level: Internal Use
HUAWEI BSC6000 V900R008
Hardware Structure
& System Description


Wireless Case and Training
ISSUE 1.0
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 2
This course describes the main function and features of
BSC6000V900R008, hardware structure and system principle
of TC/BM separated system, including board module
functions, system operating principles, system signal flows,
etc.. In addition, the recommended typical configurations are
listed (TC/BM separated & combination model) .
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 3
After learning this course, you should understand the following points:
BSC6000V900R008 function and features
Hardware structure and system principle of TC/BM separated &
combination system
Typical configuration of TC/BM separated & combination system
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 4
HUAWEI BSC6000V900R008 Product Description
HUAWEI BSC6000V900R008 Hardware Description
HUAWEI BSC6000V900R008 Features Description
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 5
Chapter 1 BSC6000V900R008 System Description
Chapter 2 BSC6000V900R008 Hardware Structure
Chapter 3 BSC6000V900R008 System Signal Flow
Chapter 4 BSC6000V900R008 Typical Configuration
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 6
BSC6000 Roadmap
V9R1C01
V9R1C03
2007.02 2007.06 2007.09
V9R3C01
Abroad
V9R8C01
2007.12
V9R1C04
Domestic
V9R1C01 is the first
business version of
BSC6000
V9R1C03 enhances
the BSC performance,
such as intelligent
power reduction,
supporting new BTS
types, etc.

GOMU
MML Command
Optical Port
Backup
Local Switching
Flex Abis
Built-in PCU
GBSS IP Solution
Abis Over HDLC
TC/BM combined
configuration
Distributed BTS is
supported
QTRU is supported
R1
R3
R8
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 7
BSC6000V9R8 Specification Description
Specification Items V9R1 V9R3
V9R8
BM/TC Separated BM/TC Combined A Interface Over IP
TRX Number (FR) 2048 2048 2048 2048/1792 2048
TRX Number (HR) 1024 2048 2048 2048/1792 2048
Full Configuration Cabinet Number 34 24 24 1 1
A Interface Circuits 15360 15360 15360 15360 15360
GxPS Subrack Number 14 14 14 14 14
GTCS Subrack Number 14 14 14 NA NA
Abis Interface E1Number 640 576 576 576/352 576
Abis Interface STM-1Number 20 18 18 18/11 18
A Interface E1Number 512 512 512 448 NA
A Interface STM-1Number 8 8 8 8 NA
Pb Interface E1 Number 224 224 224 128 224
Pb Interface STM-1Number 7 7 7 4 7
Gb Interface Throughput NA NA 256Mbps/512Mbps 256Mbps/512Mbps 256Mbps/512Mbps
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 8
Function and Features of BSC6000V9R8
BSC6000 system with external GBAM is defined as Configuration A and the
BSC using built-in GOMU is defined as configuration B.
Built-in PCU is supported, while former external PCU is also supported.
A interface over IP.
Abis interface transmission optimization.
Abis interface over HDLC
Abis interface over IP
Hub BTS of HDLC transmission mode (Abis Interface Transmission
Optimization ).
TC/BM combined and separated configuration
Um interface soft synchronization
Support Distributed Base Station DBS3900
Support QTRU
Support dynamic transmit diversity (PBT)

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 9
High Integration: A single cabinet can
support 2048 TRXs
2048TRXs can be supported by one single BSC6000V900R008 cabinet and
built-in PCU can be integratedwhich can save much space of central
equipment room.
Power consumption will decrease a lot because of high integration. Typical
power consumption of TC/BM combined full configuration is 3340W when E1
transmission is used on A/Abis interface, and 2325W, when STM1 is used on
A Interface and E1 is used on Abis Interface.
+
=
PCU6000
External PCU

BSC6000V900R008
Full capacity: 2048TRXs
One single cabinet
Built-in PCU
V900R001/V900R003
Full capacity: 2048TRXs
4 cabinets
4BM+4TC
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 10
=
+
BM/TC
Separated
BM/TC
Combined
GMPS/GEPS
Logical DPU board must
be GDPUX where
physical board is DPUc
No Ater interface boards
When BSC and MSC are located in the same equipment room, combined
BM/TC is recommended, i.e., GTCS is not needed, so the configuration is more
flexible.
When BSC and MSC are in different equipment rooms, separated BM/TC with
remote TC will be used.
GMPS/GEPS
Ater Interface
boards are needed.
GTCS
DPUa and DPUc can be
used together, configured
as GDPUC and GDPUX
Ater interface boards
More Flexible Configuration: Separated
and Combined BM/TC
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 11
Capacity Specifications
Specification Value
Maximum number of BTSs 2,048
Maximum number of cells 2,048
Maximum number of TRXs 2,048
BHCA 3,500,000
Maximum traffic volume 13,000Erl
Maximum number of subscribers 650,000
Maximum number of PDCHs can be configured 15,360
Maximum number of TBFs supported by a PDCH Uplink: 7
Downlink: 8
Number of 16K timeslots on Abis Interface 61,440
Throughput on Gb interface 512Mbps
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 12
Engineering Specifications
Spacification Value
Cabinet standard
IEC60297 standard and IEEE standard.
Cabinet outline dimensions 2200mmHight*600mmWidth*800mmDepth
Available cabinet height 46U
Weight of the cabinet Empty cabinet 150kg; cabinet in full configuration 350kg
Load-bearing capability of the
equipment room
450kg/m2
Typical
configurati
on
Power Consumption
(Ater over STM-1, Abis
over E1, Excluding the
GTCS)
Power Consumption
(A over STM-1, Abis
over E1, BM/TC
Combined)
Power Consumption
(A over E1, Abis over
E1, BM/TC
Combined)
Power
Consumption
(A over FE,
Abis over FE)
512TRX 700 890 1,325 890
1024TRX 1,080 1,510 2,320 1,510
1536TRX 1,360 1,950 3,250 1,950
2048TRX 1,530 2,325 3,340 2,325
BSC6000 Engineering Specifications
Power Consumption Specifications
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 13
Chapter 1 BSC6000V900R008 System Description
Chapter 2 BSC6000V900R008 Hardware Structure
Chapter 3 BSC6000V900R008 System Signal Flow
Chapter 4 BSC6000V900R008 Typical Configuration
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 14
Abbreviation
Abbreviation Full Name
GBCR GSM BSC Control Processing Rack
GBSR GSM BSC Service Processing Rack
GIMS GSM Integrated Management System
GBAM GSM Back Administration Module
GMPS GSM Main Processing Subrack
GEPS GSM Extended Processing Subrack
GTCS GSM TransCoder Subrack
Abbreviation of Cabinet and Subrack
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 15
Rack Structure
Cabinet Standard: The BSC6000 uses HUAWEI N68-22
cabinet, which is designed in compliance with the IEC60297
and IEEE standards.
Structure
Dimension: 600mm (width) x800mm (depth) x 2200mm (height)
Weight: Empty rack 150kg; cabinet with full configuration
350kg
Type
The BSC6000 rack is categorized into two types:
GBCR: GSM BSC Control Processing Rack
GBSR: GSM BSC Service Processing Rack
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 16
RackGBCR
GBCR: It must be configured with main
processing subrack and GBAM server. It
processes the BSC6000 services and
performs operations and maintenance.
Configuration A, GBCR consists of
GIMS
1GMPS must be included and 2Subracks
at most
Configuration B, GBCR consists of
1GMPS+ 2GEPS(at most)
GIMS:
One KVM (keyboard, video and mouse)
One LAN Switch
One GBAM (GSM Back Administration
Module) server
GBAM
Dummy
Panel
Lan
Switch
KVM
Cabling
Subrack
Air
Defense
Subrack
Power
Distribution
Box
Subrack
Subrack
In configuration B, the subrack
containing GIMS is configured
as GMPS.
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 17
RackGBSR
GBSR (GSM BSC Service Processing Rack )
It is only configured with subracks, no GBAM
server in this rack. It performs service
processing functions of the BSC6000.
One service rack can be configured with three
subracks.
According to the requirement of service quantity,
each BSC6000 system contains a maximum of
three service racks.

Dummy
panel

subrack
Air defence
subrack
Power
distribution
box
Air
defence
subrack
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 18
Subrack
Subrack: The subrack complies with
the IEC60297 standard. The width of it
is 19 inches. A backplane is in the
middle of the subrack, and boards are
inserted from the front and the rear of
the subrack. Both the front subrack
and the rear subrack provide 14 slots
respectively. The slots are numbered
0027 from the front to the rear.
The BSC6000 contains three
subracks:
GMPS: main processing subrack
GEPS: extension processing subrack
GTCS: voice processing subrack
Board
Air
Defense
Box
Cabling
subrack
Front Rear
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 19
Dip switch of Subracks
The DIP switches on the BSC subrack are
used to define the numbering of the BSC
subrack.
The DIP bits are numbered in ascending
order from bit 1 to bit 8. ON represents
digit 0 and OFF represents digit 1.
As the DIP switches use odd parity check,
the number of 1s in the eight DIP bits
must be an odd number.
Set the DIP switch as follows: Set bits 1
5 and 8 first. Set bit 7 to 0. Check the
number of 1s in the bits of the DIP switch.
If the number of 1s is even, set bit 6 to 1.
If the number of 1s is odd, set bit 6 to 0.

ON
1 8
Bit Meaning
1 Subrack number setting bit
2 Subrack number setting bit
3 Subrack number setting bit
4 Subrack number setting bit
5 Subrack number setting bit
6 Odd parity check bit
7 Reserved, generally set to 0
8
The automatic DIP bit of the GSCU board
in the central subrack.
0, the starting of boards is highly
dependent on the GBAM server, namely
that the boards load from the server after
starting.
1, the starting of boards is less
dependent on the GBAM server, namely
that the boards check the validity of the
Flash file when starting, and load from the
Flash file if the Flash file is valid or load
from the server if the Flash file is invalid.
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 20
E1/T1 transmission
Hardware ConfigurationType A
BSC6000 Full ConfigurationTC/BM Separated, Local GTCS
E1/T1 transmission is used: GIMS+1 GMPS+2 GEPS+3 GTCS
STM-1 is used on A interface : 1 GIMS+1 GMPS+2 GEPS+2 GTCS
GBCR
GIMS
GMPS
GEPS
GBSR
GEPS
GTCS
GBCR
GIMS
GMPS
GEPS
GBSR
GEPS
STM-1 on A interface
GBSR
GTCS
GTCS
GTCS
GTCS
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 21
E1/T1 transmission
Hardware ConfigurationType A
BSC6000 Full ConfigurationTC/BM Separated, Remote GTCS
E1/T1 transmission is used : 1 GIMS1 GMPS2 GEPS3 GTCS
STM-1 is used on A interface : 1 GIMS1 GMPS2 GEPS 2 GTCS
GBCR
GIMS
GMPS
GEPS
GBSR
GEPS
GBCR
GIMS
GMPS
GEPS
GBSR
GEPS
STM-1 on A interface
GBSR
GTCS
GTCS
GTCS
GBSR
GTCS
GTCS
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 22
E1/T1 transmission
Hardware ConfigurationType B
BSC6000 Full ConfigurationTC/BM Separated, Local or Remote
GTCS
E1/T1 transmission is used : 1 GMPS2 GEPS3 GTCS
STM-1 is used on A interface : 1 GMPS2 GEPS 2 GTCS
GBCR
GMPS
GEPS
GEPS
GBCR
GMPS
GEPS
GEPS
STM-1 on A interface
GBSR
GTCS
GTCS
GTCS
GBSR
GTCS
GTCS
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 23
System Logical Structure
The BSC6000 system consists of the following logical functional
subsystems:
TDM Switching Subsystem
GE Switching Subsystem
Service Processing Subsystem
Service Control Subsystem
Interface and Signaling Processing Subsystem
Clock Subsystem
TDM switching subsystem
GE switching subsystem
Clock
subsystem
Service
processing
subsystem
E1/STM-1 to BTS
Interface
and
signaling
processing
subsystem
E1/STM-1 to PCU
E1/STM-1 to MSC
Service
control
subsystem
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 24
GTNU
Active
Board
Board
LVDS TDM path of backplane
Inter-GTNU Cable
GTNU
Standby
GTNUActive
Board
Board
GTNU
Standby
TDM Switching Subsystem
Intra-Subrack: Other boards in the subrack connect with GTNU
(Active/Standby) through LVDS (Low Voltage Differential Signal) high speed
serial ports of backplane.
Inter-Subrack: TDM units of every subrack fully interconnected with each other
through GTNU crossover cables.
In full intra-subrack
interconnection, 2 cables
support 8K bandwidth.
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 25
BoardGTNU
Port Function
Matching
connector
TDM05 TDM high-speed serial port, used to connect the GTNUs between subracks
DB14
GTNU
PARC
RUN
ALM
ACT
T
N
M
5
T
N
M
4
T
N
M
0
T
N
M
1
T
N
M
2
T
N
M
3
The GTNU is the TDM switching unit in the BSC6000. The active GTNU and
the standby GTNU are inserted in slot 4 and slot 5 of the GMPS/GEPS/GTCS.
The GTNU board performs the TDM switching function, which is the TDM
switching center of the system.
The GTNU has the following functions:
Providing 128 K 128 K TDM switching
Allocating TDM network resources, establishing, and releasing radio links
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 26
Inter-Subrack Interconnections of GTNU
Crossover Cables
Pin1
2
W1 W3
W2 W4
1
B
B
X4
X3 X1
X2
A
A
Pin14
Pin1 Pin14
3
1
0
GTNU GTNU
GTNU GTNU
2
GTNU GTNU
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 27
GSCU (Active)
Board
Board
GE of Rear
Intercross Cable
GSCU
(Standby)
GSCU (Active)
Board
Board
GSCU
(Standby)
GE Switching Subsystem
Intra-subrack active/standby GSCU boards: HiG interconnection; 30G
bandwidth.
Intra-subrack GE switching: The GSCU board provides 48G GE switching
capability through backplane.
Inter-subrack GE switching: The GSCU boards are connected in star topology
through intercross cable using the GE ports on GSCU.
Star interconnection
between subracks, four
cable realize Active/Standby
model
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 28
BoardGSCU
Port Function
Matching
EHT09 10M/100M/1000M Ethernet ports, used to connect subracks
RJ45
EHT1011
10M/100M/1000M Ethernet ports, used to connect GBAM (Only the main subrack is
connected with the GBAM)
RJ45
COM Debugging port
RJ45
CLKIN
Clock source port, used to receive the 8 kHz clock signals from the panel of the
GGCU
RJ45
TESTOUT Clock test signal port, used to output clock test signals SMB connector
The GSCU is the switching control unit in the BSC6000. The active
and standby GSCU are inserted in slot 6 and 7 of the GMPS/GEPS/GTCS.
The GSCU board provides maintenance management of the subrack and
GE switching platform for the subrack.
The GSCU has the following functions:
Performing maintenance management of the subrack
Providing a GE platform for the subrack
Providing clock information for the other boards in the same subrack except the
GGCU
SCUa
PARC
RUN
ALM
ACT
C
O
M
TESTOUT
C
L
K
IN
ACT
LINK
1
0
/1
0
0
/1
0
0
0
B
A
S
E
-T
RESET
ACT
LINK
8
9
0
1
2
3
4
5
6
7
11
10
ACT
LINK
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 29
LMT
M2000
LanSwitch
GBAM
GSCU in GMPS
GE 0
GE 1
GE 2
GE 3
GE 4
GE 5
GE 6
GE 9
GE 7
GE 8
GE 10
GE 11
FE
GE TRUNK1
GE TRUNK3
GE TRUNK4
GE TRUNK6
GE TRUNK5
GE TRUNK4
CPU FE
GE 0
GE 1
GE 0
GE 1
GE 0
GE 1
1#GEPS
GE TRUNK2
GE Switching Interconnection
GSCU in GMPS
GE0/1: Idle
GE27 interconnect with GEPS
GE8/9 interconnect with main
GTCS
GE10/11 interconnect with GBAM
GSCU in GEPS
GE0/1 interconnect with GMPS
GE 0
GE 1
2#GEPS
3#GEPS
Main GTCS
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 30
Interconnection Between Subrack
A interface
Pb interface
Abis interface
Ater interface
Subracks of BSC6000 compose an interconnection switching network
through cascade.
GTCS
GTCS
GTCS
TC
GEPS
GMPS
GEPS
BM
GSCU Star interconnection
GTNU Full interconnection
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 31
Service Processing Subsystem
Hardware entity of service processing subsystem are DPUa/ DPUc/ DPUd
boards:
DPUa board can only be used in GTCS and configured as DPUC, and it cannot be
used in TC/BM combined configuration.
DPUc board is configured as DPUX both in BM/TC combined and separated
configuration.
DPUd board processes built-in PCU packet service and is configured as GDPUP;
In separated configurationDPUa and DPUc can be used together and configured
as GDPUC and GDPUX respectively.
Note: V9R1/V9R3 only support DPUa, which is configured as GDPUC
G
O
I
U
T
G
O
I
U
T




14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
A
G
E
I
U
A
G
E
I
U
A
G
E
I
U
A
24 25 26 27
G
O
M
U
22 23
G
T
N
U

G
T
N
U
00 01 02 03 04 05
G
D
P
U
X
G
D
P
U
X
G
D
P
U
X
10 11 12 13
G
S
C
U
G
S
C
U
G
D
P
U
X
G
D
P
U
X
06 07 08 09
15
R
e
a
r

F
r
o
n
t
GTCS










Backplane
G
E
I
U
A
G
E
I
U
A
G
E
I
U
A
G
E
I
U
A
G
E
P
U
G
G
O
I
U
T
G
O
I
U
T
G
E
P
U
G




14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26 27
G
O
M
U
22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05




10 11 12 13
G
S
C
U
G
S
C
U
G
D
P
U
P
G
D
P
U
P
06 07 08 09
15
GMPS/GEPS










Backplane
Recommended to be blank for future upgrade
R
e
a
r

F
r
o
n
t
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 32
BoardGDPUX/ GDPUC
GDPUX / GDPUC process CS services and are configured in
00~03 or 08~13, boards perform the voice coding and
decoding function. It works as subrack resource pool mode.
GDPUX / GDPUC perform function as follows:
Provides Tandem Free Operation (TFO) functions, When the calling
and called MSs use one voice coding scheme, the voice signals are
encoded only once at the originating MS and decoded only once at the
terminating MS. This reduces repeated encoding and decoding and
improves the quality of speech services.
Provides voice enhancement function
Detects voice faults automatically
GDPUX is configured in BM:
Provides format conversion for 3740 IP speech paths and HDLC
optimized speech paths as well as data forwarding.

DPUa
PARC
RUN
ALM
ACT
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 33
BoardGDPUP
The GDPUP is the GSM Data Processing Unit for PS
services. It can be installed in slots 811 in GMPS and 8-27
in GEPSit processes the packet services for the BSC.
GDPUP is configured when PCU is inner.
GDPUP performs the following function:
Each GDPUP supports 1024 activated PDCHs at the same time,
and all the PDCHs support MSC-9 coding.
Packet links processing function.
PS fault self-detection.
GDPUP works as system resource pool.

DPUa
PARC
RUN
ALM
ACT
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 34
Service Control Subsystem
The BSC service control subsystem performs the following functions:
paging control, message management, channel assignment, BTS public
service management, call control, packet service control, handover and
power control, cell broadcast short message service, and TC resource
pool management, etc.

The components of the BSC service control subsystem are as follows:
GXPUM
GXPUT
GBAM/GOMU
GSCU boards in GTCS

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 35
BoardGXPUM /GXPUT
GXPU
PARC
RUN
ALM
ACT
1
0
/ 1
0
0
/ 1
0
0
0
B
A
S
E
- T
ACT
LINK
0
1
2
3
GXPUM /GXPUT
GXPUM is the main service processing board, which is
configured in slot 01 of GMPS/GEPS.
GXPUT is transmission processing unit and is configured in 23
slots of GMPS/GEPS.
GXPUM/GXPUT have four built-in CPUs and processes the key
services of the BSC.
When the TRX number configured in a single subrack is
less than 256, GXPUT isnt necessary.
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 36
CPUs of XPU board are classified as CPU0,CPUX,CPUP
G
E
I
U
P
G
O
I
U
T
G
O
I
U
T
G
E
I
U
P




14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26 27
G
O
M
U
22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05




G
G
C
U
G
G
C
U
10 11 12 13
G
S
C
U
G
S
C
U





06 07 08 09
15
GMPS/GEPS in Configuration B
Backplane
G
E
I
U
P
G
O
I
U
T
G
O
I
U
T
G
E
I
U
P




14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26 27
G
O
M
U
22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05




G
G
C
U
G
G
C
U
10 11 12 13
G
S
C
U
G
S
C
U





06 07 08 09
15
GMPS/GEPS in Configuration A










Backplane
Name CPUs Types Function
GXPUM
CPU0 CPU0 Algorithm, Resource Management, PS Signal Processing
CPU3 CPUP Built-in PCU Maintenance, Cell Broadcast
CPU1
CPUX

CPU2
GXPUT
CPU0 CS Service and signal processing
CPU1
CPU2
CPU3
BoardGXPUM /GXPUT
R
e
a
r

F
r
o
n
t
R
e
a
r

F
r
o
n
t
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 37
G
E
I
U
P
G
E
I
U
P




GBAM, GOMU Board
GBAM/GOMU performs the following function in BSC:
Provides configuration management, performance management, fault management,
security management, and loading management for the BSC.
As the OM center of the BSC, the GOMU enables the communication between the
LMT and the other boards in the BSC. The GOMU features high computation speed
and outstanding data processing capability.
Interfaces with the LMT/M2000 on behalf of the BSC
G
O
I
U
T
G
O
I
U
T




14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26 27
G
O
M
U
22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05




G
G
C
U
G
G
C
U
10 11 12 13
G
S
C
U
G
S
C
U





06 07 08 09
15
Backplane
GMPS of Configuration B
G
O
I
U
T
G
O
I
U
T
14 16 17 18 19 20 21
G
E
I
U
B
G
E
I
U
B
24 25 26 27 22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U
00 01 02 03 04 05




G
G
C
U
G
G
C
U
10 11 12 13
G
S
C
U
G
S
C
U





06 07 08 09
15
GBAM

G
T
N
U
GMPS of Configuration A
G
E
I
U
B
G
E
I
U
B
Backplane




G
E
I
U
P
G
E
I
U
P
R
e
a
r

F
r
o
n
t
R
e
a
r

F
r
o
n
t
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 38
GBAM Interface
LCD Interface
RJ45 NIC RJ45 NIC Interface RJ45
RJ45 NIC
10M/100M
Automatic
Adaptation Port
KVM Interface
DC Prot
End
Power Button
CD Rom
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 39
BoardGOMU
As the OM center of the BSC, the GOMUs are installed in slots 2023 in GMPS
and work in active/standby mode. The GOMU features high computation
speed and outstanding data processing capability .
The GOMU has the following functions:
Provides configuration management, performance management, fault management, security
management, and loading management for the BSC.
Interfaces to the LMT/M2000 on behalf of the BSC


(1) Screw (2) Leaf spring (3) Wrench
(4) RUN LED (5) ALM LED (6) ACT LED
(7) Reset button (8) Shutdown button (9) USB port
(10) ETH0 (Ethernet port) (11) ETH1 (Ethernet port) (12) ETH2 (Ethernet port)
(13) COM port (14) VGA port (15) HD LED
(16) OFFLINE LED (17) Hard disk (18) Screw for fix the hard disk
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 40
Interface Processing Subsystem
Interface processing subsystem provides interfaces between
BSC/BTS/NSS, and performs data link layer signal processing function.
Provide A/Abis/Pb/Ater/Gb interface
Support processing of cell broadcast service
Support No.7 signal MTP processing
BTS
GMPS/
GEPS
GTCS
MSC
PCU
SGSN
BSC6000
Abis
Pb Gb
Ater
A
CBC
Cb
Built-in or
External PCU
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 41
EIUa
OIUa
PEUa
FG2a
GOUa
GEIUA
GEIUB
GEIUT
GEIUP
\
GOIUA
GOIUB
GOIUT
GOIUP
\
\
GEHUB
\
\
GFGUA
\
\
GGOUA
GGOUB GFGUB
GFGUG
\
\
Physical Board
A
Abis
Ater
Pb
Gb GEPUG
\
Interface Board
RINT Interface
EIUa 32 E1/T1 Interface A/Abis/Pb
OIUa 1 TDM over STM-1 A/Abis/Pb
PEUa 32 Packet over E1/T1 Interface Abis/Gb
FG2a 8 Packet over FE or 2 Packet over GE Electrical Interface A/Abis/Gb
GOUa 2 Packet over GE Optical Port A/Abis
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 42
BoardEIUa/OIUa
GOIU
PARC
RUN
ALM
ACT
T
E
S
T
O
U
T
2
M
0
2
M
1
RX
LOS
TX
GEIU
PARC
RUN
ALM
ACT
E
1
/
T
1
(
0
~
7
)
E
1
/
T
1
(
1
6
~
2
3
)
E
1
/
T
1
(
2
4
~
3
1
)
E
1
/
T
1
(
8
~
1
5
)
T
E
S
T
O
U
T
2
M
0
2
M
1
2 1
Interface boards GEIU / GOIU contain:
GEIUB/GOIUB for Abis Electrical Unit/ Optical Unit
GEIUP/GOIUP for Pb Electrical Unit/ Optical Unit
GEIUT/GOIUT for Ater Electrical Unit/ Optical Unit
GEIUA/GOIUA for A Electrical Unit/ Optical Unit
Main function contain:
EIUa provides 32E1 ports
OIUa provides 1STM-1 interface, which bears 63E1
Supply remote GTCS maintenance link
Provides Tributary Protection Switching (TPS) between the
active and standby boards.
Interface Function
Matching
connector
E1/T1(0
31)
E1/T1 port, used to transmit and receive E1/T1 signals
on routes 07
DB44
2M01
2.048 MHz clock source output port, used to output the
extracted line clock as the system clock source
SMB male
connector
TESTOUT
2.048 MHz clock output port, used to output the testing
clock of the system
SMB male
connector
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 43
BoardFG2a
Interface ID Type Function
10/100M RJ45
The 10M/100M ports are used to transmit 10/100
Mbit/s signals
10/100/1000M RJ45
The 10M/100M/1000M ports are used to transmit
10/100/1000 Mbit/s signals.
2M0 No use
2M1 No use
Physical Name Logical Name Value
FG2a
GFGUA 6144 voice circuit
GFGUB 384TRX, 100%(HR)
GFGUG 128M bps Gb throughput
Main function:
8 10M/100M FE ports, thereinto 2 GE ports(0,4)
Provides IP routing
Provides the routing-based backup and load sharing
Provides Tributary Protection Switching (TPS) between the active and
standby boards
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 44
BoardGOUa
Interface
ID
Type Function
RX
LC/PC
Optical ports are used to receive and transmit
optical signals. TX indicates the transmitting
optical port and RX indicates the receiving optical
port.
TX
2M0 No use
2M1 No use
Physical
Name
Logical
Name
Value
GOUa
GOGUA 6144 voice circuit
GOGUB 384TRX, 100%(HR)
Main function:
Provides two GE optical ports
Provides IP routing
Provides the routing-based backup and load sharing
Provides Tributary Protection Switching (TPS) between the active
and standby boards
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 45
BoardPEUa
Interface ID Type Function
E1/T1(0~31) DB44 031 E1/T1 for transmitting signal
2M0
SMB Male
Connector
No use
2M1
SMB Male
Connector
No use
Physical Name Logical Name Value
PEUa
GEHUB 384TRX, 100%(HR)
GEPUG 64M bps Gb throughput
Main function
Provides 32 E1/T1 ports
Provides Tributary Protection Switching (TPS) between the active
and standby boards
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 46
GSCU GSCU
GGCU (Active/Standby)
0# subrack
Board Board Board
GMPS
GEPS
Time synchronization
primary reference
Transmission synchronization
reference source
Backplane
Distribution cable
transmission
Backplane
Backplane
GEPS
Clock System
Board
GSCU
Board
Backplane
Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 47
BoardGGCU
GGCU
PARC
RUN
ALM
ACT
8
9
COM0
COM1
0
1
2
3
4
5
6
7
C
L
K
O
U
T

T
E
S
T
I
N

T
E
S
T
O
U
T

C
L
K
L
I
N
1

C
L
K
L
I
N
0

Port Function
Matching Connector
CLKOUT09 Synchronization signal output port, used to output 8 kHz clock
signals to the GSCU
RJ45
COM01 Standby RJ45
TESTOUT Standby SMB male connector
TESTIN Standby SMB male connector
CLKIN01 Synchronization clock signal input port, used to input one route of
external 2.048 MHz signal and 2.048 Mbit/s code stream signals
SMB male connector
The GGCU is the general clock unit in the BSC6000. The active
GGCU and the standby GGCU are configured in slots 12 and 13 in
the GMPS. The GGCU board provides synchronous timing signals
for the system
The GGCU has the following functions:
Generating and keeping synchronous clock signals
Keeping the consistency of synchronization information output from the active and
standby GGCUs
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 48
Clock Subsystem
GGCU Reference Clock Input
To input the active-standby clock of the GGCU, you can use the signals provided by the BITS and the 2.048MHz
clock signal extracted from the upper-level clock by the interface panel in the service subrack.
The GGCU backplane uses the interface panel of the same subrack to extract the 8 KHz clock signals from the
upper-level clocks.
Reference Clock for the GMPS or GEPS
The reference clocks are provided by the GGCU. The reference clocks generate 8kHz clock signals through the
GGCU.
GMPS: The clock signals are sent to the GSCU in the GMPS subrack through the backplane. Then, the clock
signals are sent to other boards in the same subrack.
GEPS: The clock signals are sent to the GSCU board in the GEPS subrack through the clock cable. Then, the
signals are sent to other boards through the backplane.
Reference Clock for the GTCS
Each GTCS extracts line clock from the A interface. The line clock is processed through A interface panel and then
generates 8 KHz clock signals.
The clock signals are sent to the GSCU in the subrack through the backplane. Then the clock signals are sent to
other boards in the same subrack.
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 49
The connection of the GGCU of the main subrack and the GSCU of the
extension subrack is shown as following figure:
The active GGCU and the standby GGCU output 10-way signal channel
respectively. A signal channel of an active GGCU and that of a standby GGCU are
integrated through the Y-shaped cable.
GGCU support six service subracks, one is the GMPS, others five are the GEPSs
where the 10 cables from GSCUs to GGCU can be connected at most.
Any of component including GGCU, Y-shaped cable, and GSCU is faulty, the
system clock still can work normally.
Clock Synchronization Interconnection
GMPS
GGCU GGCU
GEPS
GSCU GSCU
GEPS
GSCU GSCU
Y Cable


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 50
Clock Cable
1
1
2
1
8
1
8
1
8
W2
W3
X2
X3
W1
X1
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 51
Chapter 1 BSC6000V900R008 System Description
Chapter 2 BSC6000V900R008 Hardware Structure
Chapter 3 BSC6000V900R008 System Signal Flow
Chapter 4 BSC6000V900R008 Typical Configuration
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 52
Voice Service Signal Flow
Ater
A
Abis
BTS
MS
MSC
G
E
I
U
B
G
T
N
U
G
E
I
U
T
GMPS/GEPS
G
E
I
U
T
G
T
N
U
G
E
I
U
A
GTCS
G
D
P
U
X
Abis over TDM+A over TDM
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 53
Voice Service Signal Flow
Ater
A
Abis
BTS
MS
MSC
G
E
H
U
B
G
T
N
U
G
E
I
U
T
GMPS/GEPS
G
E
I
U
T
G
T
N
U
G
E
I
U
A
GTCS
G
D
P
U
X
Abis over HDLC/IP+A over TDM
G
D
P
U
X
G
S
C
U
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 54
Packet Service Signal Flow (External PCU)
Pb Gb
Abis
BTS
MS
PCU
G
E
I
U
B
G
T
N
U
G
E
I
U
P
GMPS/GEPS
SGSN
Abis over TDM
When Abis interface is over HDLC/IP, BSC6000 doesnt support external PCU.
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 55
Packet Service Signal Flow (Built-in PCU)
Gb
Abis
BTS
MS
G
E
I
U
B
G
T
N
U
G
E
P
U
G
GMPS/GEPS
Abis over HDLC/IP
SGSN
Gb
Abis
BTS
MS
GMPS/GEPS
SGSN
Abis over TDM
G
S
C
U
G
D
P
U
P
G
S
C
U
G
E
P
U
G
G
S
C
U
G
D
P
U
P
G
E
H
U
B
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 56
Abis Interface Signal
Abis
BTS
MS
A
b
i
s

B
o
a
r
d

G
S
C
U
GMPS/GEPS
G
X
P
U
T
G
X
P
U
M
G
S
C
U
Abis interface board will be determined by the protocol on Abis interface:
Abis over TDM: GEIUB/GOIUB
Abis over HDLC: GEHUB
Abis over IP: GFGUB
Signal processing flow:
GXPUT/GXPUM process LAPD and RR protocol
GXPUM process BTSM protocol
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 57
No.7 Signal Flow
Through the processing of MTP2 model, it will be
transmitted to GXPUM as internal signal.
Ater
A
MSC
G
S
C
U
G
E
I
U
T
GMPS/GEPS
G
E
I
U
T
G
T
N
U
G
E
I
U
A
GTCS
G
X
P
U
M
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 58
Ater Signal Flow
Through the processing of MTP2
model, it will be transmitted to
GXPUM as internal signal.
Through the processing of MTP2
model, it will be transmitted to
GSCU as internal signal.
Ater
G
S
C
U
G
E
I
U
T
GMPS/GEPS
G
E
I
U
T
G
S
C
U
GTCS
G
X
P
U
M
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 59
Pb Signal Flow (External PCU)
Through the processing of LAPD
model, it will be transmitted to
GXPUM as internal signal.
Pb Gb
PCU
G
S
C
U
G
E
I
U
P
GMPS/GEPS
SGSN
G
X
P
U
M
The BSC internal signaling flow from the Pb interface is as follows:
The signaling is transmitted to the GXPUT/GXPUM in the GMPS/GEPS over the Pb
interface.
The GXPUT processes the signaling according to the LAPD protocol.
Upon reception of the signaling from the GSCU, the GXPUM processes the
signaling according to the PbIP and RR protocols.
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 60
Gb Signal Flow (Built-in PCU)
The BSC internal signaling flow from the Gb interface is as follows:
The signaling is transmitted to the GMPS/GEPS over the Gb interface. If the sub
NS layer of the NS protocol complies with the FR protocol, the Gb interface board is
the GEPUG. If the sub NS layer of the NS protocol complies with the IP protocol,
the Gb interface board is the GFGUG.
The GSCU transmits the signaling to the GXPUM.
The GXPUM processes the signaling according to the NS and BSSGP protocols.

Gb
G
S
C
U
G
E
P
U
G
GMPS/GEPS
SGSN
G
X
P
U
M
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 61
Operation Maintenance Flow
Service
Board
G
S
C
U
G
E
I
U
T
G
S
C
U
G
E
I
U
T
GTCSRemote GMPS Ater
G
S
C
U
L
M
T
Service
Board
GEPS
HDLC Link
G
S
C
U
GTCSLocal
O
M
U
Hardware is
GBAM/GOMU

Backplane GE Switching
Inter-Subrack Switching
E1/T1 cable
Service
Board
Service
Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 62
Operation Maintenance Flow
GMPS OML Path:
LMTGBAMGSCUGMPS Subrack Boards
GEPS OML Path:
LMT GBAM GSCU GSCU Intercross Cable GSCUGEPS Subrack
Boards
GTCS Configuration OML Path:
GTCS Remote: LMT GBAM GSCUGEIUTHDLC GEIUT GSCU
GTCS Subrack Boards
GTCS Local: LMT GBAM GSCUIntercross CableGSCUGTCS
Subrack Boards
BTS Configuration OML Path:
BTS is configured in GMPS: LMT GBAM GSCUGEIUBBTS
BTS is configured in GEPS: LMT GBAM GSCUGSCU Intercross Cable
GSCU GEIUBBTS
GMPS Board
GTCS Board
GEPS Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 63
Chapter 1 BSC6000V900R008 System Description
Chapter 2 BSC6000V900R008 Hardware Structure
Chapter 3 BSC6000V900R008 System Signal Flow
Chapter 4 BSC6000V900R008 Typical Configuration
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 64
Hardware configuration Principle
Service processing boards
One single GDPUX/GDPUC supplies 960 voice circuits coding/decoding, GDPUX/
GDPUC work as resource pool in the subrack.
One single GDPUX supports 3740 voice circuits frame conversion or transmission
between IP/HDLC and TRAU.
One single GDPUP provides a processing capability of 1024 MCS-9 PDCH channels and
supports 1024 cells at most, GDPUP works as resource pool in whole system and could
be inserted in rear slots.
Number of GDPUP+GDPUX+GDPUC couldnt be more than 10.
GXPUM/GXPUT
GXPUM must be inserted in slot 0&1 of GMPS/GEPS fixedly;.
GXPUT is inserted in slot 2&3 of GMPS/GEPS by requirement, when the number of
TRX in same subrack is less than 256, GXPUT may not be configured.
Interface Specification
Abis: GEIUB/GOIUB supports 256TRXs (HR) at most, GEHUB/GFGUB/GOGUB also
support 384TRX(HR)at most.
Ater: GOIUT/GEIUT support 7168/3840 voice circuits at most.
A: 5 groups of GOIUA/GEIUA can be configured per subrack at most. If A interface uses
STM-1 transmission, at most 9600 CIC can be accessed in a single subrack.
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 65
Typical Configuration
512TRXs
Configuration A, External PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface
Configuration B, External PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface
Configuration A, Built-in PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface
Configuration B, Built-in PCU, RemoteGTCS, E1/T1 on A Interface, E1/T1 on Abis Interface
1280TRXs
Configuration A, Built-in PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface
Configuration B, Built-in PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface
Full Configuration 2048/1792 TRXs
Configuration B, External PCU, Remote GTCS, STM-1 on A Interface, E1/T1 on Abis
Interface, 2048TRXs
Configuration B, Built-in PCU, GTCS Remote, STM-1 on A Interface, E1/T1 on Abis Interface,
2048TRXs
Configuration A, External PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface,
1792TRXs
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 66
Typical Configuration 512TRX
External PCU
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 67
Typical Configuration 512TRX
Built-in PCU
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 68
Typical Configuration 1280TRX
1GMPS+1GEPS+2GTCS, Built-in PCU
GBAM
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 69
Typical Configuration 2048TRX
External PCU
Built-in GOMU
GOIUA is the A
interface board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 70
Typical Configuration 2048TRX
Built-in PCU
Built-in GOMU
GOIUA is the A
interface board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 71
Typical Configuration 1792TRX
GBAM
2008-05
www.huawei.com
HUAWEI Confidential
Security Level: Internal Use
Appendix

Difference in TC/BM combination mode



HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 73
Chapter I BSC6000V900R008 Hardware Structure

Chapter II BSC6000V900R008 System Signal Flow

Chapter III BSC6000V900R008 Typical Configuration
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 74
E1/T1 as transport model
Hardware Configuration Type A
BSC6000 Full Configuration (TC/BM Combinationwithout GTCS)
E1/T1 are the interface transport model: 1 GIMS1 GMPS3 GEPS
STM-1 is used in A interface :1 GIMS1 GMPS2 GEPS
GBCR
GIMS
GMPS
GEPS
GBSR
GEPS
GEPS
GBCR
GIMS
GMPS
GEPS
GBSR
GEPS
A interface is optical
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 75
E1/T1 as transport model
Hardware Configuration Type A
BSC6000 Full Configuration (TC/BM Combinationwithout GTCS)
E1/T1 are the transport model : 1 GMPS3 GEPS
STM-1 is used in A interface: 1 GMPS2 GEPS
GBCR
GMPS
GEPS
GEPS
GBSR
GEPS
GBCR
GMPS
GEPS
GEPS
A interface is optical
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 76
LMT
M2000
LanSwitch
GBAM
GSCU in GMPS
GE 0
GE 1
GE 2
GE 3
GE 4
GE 5
GE 6
GE 9
GE 7
GE 8
GE 10
GE 11
FE
GE TRUNK1
GE TRUNK3
GE TRUNK4
GE TRUNK6
GE TRUNK5
GE TRUNK4
CPU FE
GE 0
GE 1
GE 0
GE 1
GE 0
GE 1
1GEPS
GE TRUNK2
GE Switching Interconnection
GSCU in GMPS
GE0/1 : Idle
GE27 interconnect with GEPS
GE10/11 interconnect with GBAM
GSCU in GEPS
GE0/1 interconnect with GEPS

2GEPS
3GEPS
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 77
Interconnection Between Subrack
A interface
Gb/Pb interface
Abis interface
Subracks in BSC6000 compose an interconnection switching network
through cascade.
GEPS
GMPS
GEPS
BTS
MS
MSC
SGSN
GSCU Star interconnection
GTNU Full interconnection
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 78
Service Processing Subsystem
Hardware entity of service processing subsystem are DPUc/DPUd boards:
DPUa couldnt be used in V900R008 combination model;
DPUc is configured as DPUX on combination model;
DPUd board processes inner PCU packet service and is configured as GDPUP;
Note: DPUData Processing Unitis digital signal processing unit for PARC platform,
acd physical version.
G
D
P
U
P
G
D
P
U
X
G
D
P
U
X
GEPS
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
E
P
U
G
G
E
P
U
G
14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26 27
G
O
M
U
22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05
G
D
P
U
X
G
D
P
U
X
G
G
C
U
G
G
C
U
10 11 12 13
G
S
C
U
G
S
C
U
G
D
P
U
P
G
D
P
U
P
06 07 08 09
15
Rear




Front
Backplane
GMPS
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
14 16 17 18 19 20 21
G
E
I
U
B
G
E
I
U
B
24 25 26 27 22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05
G
D
P
U
X
10 11 12 13
G
S
C
U
G
S
C
U
G
D
P
U
P
G
D
P
U
P
06 07 08 09
15
Rear




Front
Backplane
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
O
I
U
A
G
O
I
U
A
G
E
I
U
B
G
D
P
U
X
G
D
P
U
X
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 79
BoardGXPUM /GXPUT
G
D
P
U
P
G
D
P
U
X
G
D
P
U
X
GEPS
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
E
P
U
G
G
E
P
U
G
14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26 27
G
O
M
U
22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05
G
D
P
U
X
G
D
P
U
X
G
G
C
U
G
G
C
U
10 11 12 13
G
S
C
U
G
S
C
U
G
D
P
U
P
G
D
P
U
P
06 07 08 09
15
Rear




Front
Backplane
GMPS
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
14 16 17 18 19 20 21
G
E
I
U
B
G
E
I
U
B
24 25 26 27 22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05
G
D
P
U
X
10 11 12 13
G
S
C
U
G
S
C
U
G
D
P
U
P
G
D
P
U
P
06 07 08 09
15
Rear




Front
Backplane
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
O
I
U
A
G
O
I
U
A
G
E
I
U
B
G
D
P
U
X
G
D
P
U
X
CPUs of XPU board are distributed as CPU0,CPUX,CPUP
Name CPUs CPU Types Function
GXPUM
CPU0 CPU0 Algorithm, Resource Management, PS Signal Processing
CPU3 CPUP Inner PCU Maintenance, Cell Broadcast
CPU1
CPUX

CPU2
GXPUT
CPU0 CS Service and signal processing
CPU1
CPU2
CPU3
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 80
GBAM and GOMU Board
Rear




Front
G
E
I
U
B
27
G
G
C
U
13
Backplane
GBAM
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
E
P
U
G
G
E
P
U
G
14 16 17 18 19 20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26 27 22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05
G
D
P
U
X
G
D
P
U
X
G
G
C
U
G
G
C
U
10 11 12 13
G
S
C
U
G
S
C
U
G
D
P
U
P
G
D
P
U
P
06 07 08 09
15
Backplane
GMPS
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
O
I
U
A
G
E
P
U
G
G
E
P
U
G
14 16 17 18 19
G
O
M
U
20 21
G
E
I
U
B
G
E
I
U
B
G
E
I
U
B
24 25 26
G
O
M
U
22 23
G
X
P
U
M
G
X
P
U
T
G
X
P
U
T
G
X
P
U
M
G
T
N
U

G
T
N
U
00 01 02 03 04 05
G
D
P
U
X
G
D
P
U
X
G
G
C
U
10 11 12
G
S
C
U
G
S
C
U
G
D
P
U
P
G
D
P
U
P
06 07 08 09
15
Rear




Front
GMPS
Suggest to be empty for future upgrade
GBAM and GOMU finish the following function in BSC:
Provides configuration management, performance management, fault management,
security management, and loading management for the BSC;
As the OM center of the BSC, the GOMU enables the communication between the
LMT and the other boards in the BSC. The GOMU features high computation speed
and outstanding data processing capability.
Interfaces with the LMT/M2000 on behalf of the BSC
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 81
Chapter I BSC6000V900R008 Hardware Structure

Chapter II BSC6000V900R008 System Signal Flow

Chapter III BSC6000V900R008 Typical Configuration
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 82
Voice Service Signal Flow
Abis over TDM+A over TDM

A
Abis
BTS
MS
MSC
G
E
I
U
B
GMPS/GEPS
G
T
N
U
G
E
I
U
A
G
D
P
U
X
A Board is GEIUA/GOIUA
Abis Board is GEIUB/GOIUB
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 83
Voice Service Signal flow
Abis Over HDLC/IP+A Over TDM

A
Abis
BTS
MS MSC
G
E
H
U
B
GMPS/GEPS
G
T
N
U
G
E
I
U
A
G
D
P
U
X
G
S
C
U
A interface board is
GEIUA/GOIUA
When Abis is Over IP, interface board is
GFGUB/GOGUB
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 84
No.7 Signal Flow
Through the processing of MTP2 model, it will
be transmitted to GXPUM as intra-signal;

A
MSC
G
S
C
U
GMPS/GEPS
G
E
I
U
A
G
X
P
U
M
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
Front Board
Rear Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 85
Operation Maintenance Flow
G
S
C
U
GMPS
G
S
C
U
L
M
T
Service
Board
GEPS
O
M
U
Hardware is
GBAM/GOMU

Service
Board
Backplane GE Switching
Backplane TDM Switching
E1/T1 cable
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 86
Operation Maintenance Flow
GMPS OML Path:
LMT-GBAM/GOMU-GSCU-GMPS Subrack Boards
GEPS OML Path:
LMT-GBAM/GOMU-GSCU-GSCU Intercross cable-GSCU-GEPS Subrack Boards
BTS Configuration OML Path:
BTS is configured in GMPS
LMT-GBAM/GOMU-GSCU-GEIUB-BTS
BTS is configured in GEPS
LMT-GBAM/GOMU-GSCU-GSCU Intercross cable-GSCU-GEIUB-BTS
The OML flow in this page just should be used in Abis Over TDM
GMPS Board
GTCS Board
GEPS Board
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 87
Chapter I BSC6000V900R008 Hardware Structure

Chapter II BSC6000V900R008 System Signal Flow

Chapter III BSC6000V900R008 Typical Configuration
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 88
Hardware configuration Principle
Service processing boards
Single GDPUX supplies 960 voice circuits coding/decoding, it works as resource pool in
subrack. If just need 1 board, we can configed as 2 boards, Otherwise do not config as N+!.
DPUX supports 3740 voice circuits frame conversion or transmission between
TRAU/IP/HDLC and TRAU, We can config as N+! Mode.
Single GDPUP supplies 1024 MCS-9 PDCH channel of processing packet service, supports
1024 cells at most, GDPUP is resource pool of whole system and could be inserted in rear
slots;
Number of GDPUP+GDPUX+GDPUC couldnt be more than 10;
GXPUM/GXPUT
GXPUM must be inserted in 0&1 slots of GMPS/GEPS fixedly;
GXPUT is inserted in 2&3 slots of GMPS/GEPS by requirement, when the TRX of current
subrack is less than 256, CXPUT may not be configured, if needs, its certainly;
Interface Specification
Abis: GEIUB/GOIUB support 256TRX(HR)at most, GEHUB GFGUB/GOGUB also support
384TRX(HR)at most;
A: GOIUA/GEIUA are configured 5 groups per subrack at most, if A interface uses optical
transport, single subrack could access 9600 CIC at most;
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 89
Typical Configuration
512TRX
Configuration A, Outer PCU, A Interface Optical, Abis Interface E1/T1
Configuration A, Inner PCU, A Interface Optical, Abis Interface E1/T1
Configuration B, Outer PCU, A Interface Optical, Abis Interface E1/T1
Configuration B, Inner PCU, A Interface Optical, Abis Interface E1/T1
1280TRX
Configuration A/B, Outer PCU, A Interface Optical, Abis Interface E1/T1
Configuration A/B, Inner PCU, A Interface Optical, Abis Interface E1/T1
Full Configuration 2048TRX
Configuration A, Outer PCU, A Interface Optical, Abis Interface E1/T1
Configuration B, Outer PCU, A Interface Optical, Abis Interface E1/T1
Configuration A, Inner PCU, A Interface Optical, Abis Interface E1/T1
Configuration B, Inner PCU, A Interface Optical, Abis Interface E1/T1
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 90
Typical Configuration 512TRX
Outer PCUA interface
uses STM-1 as transport
model, Abis interface uses
E1/T1 as transport model,
supports 512TRX at most.
Left: configuration
A:1GIMS+1GMPS
Right: configuration B,1GMPS
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 91
Typical Configuration 512TRX
Inner PCUA interface uses
STM-1 as transport model,
Abis interface uses E1/T1 as
transport model, supports
512TRX at most.
Left: configuration A
1GIMS+1GMPS
Right: configuration B,1GMPS
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 92
Typical Configuration 1028TRX
Outer PCUA interface uses
STM-1 as transport model, Abis
interface uses E1/T1 as transport
model, supports 1028TRX at most.
Leftconfiguration A
1GIMS+1GMPS+1GEPS
Rightconfiguration
B,1GMPS+1GEPS

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 93
Typical Configuration 1028TRX
Inner PCUA interface uses
STM-1 as transport model,
Abis interface uses E1/T1 as
transport model, supports
1280TRX at most.
Leftconfiguration A
1GIMS+1GMPS+1GEPS
Rightconfiguration
B,1GMPS+1GEPS

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 94
Typical Configuration 2048TRX
Configuration:
1GIMS+1GMPS+2GEPS
Supports 2048TRX at most.
Configuration A, Outer GBAM
Outer PCU
A interface uses STM-1 as
transport model
Abis interface uses E1/T1 as
transport model


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 95
Typical Configuration 2048TRX
Configuration:
1GIMS+1GMPS+2GEPS
Supports 2048TRX at most.
Configuration B, Inner GOMU
Outer PCU
A interface uses STM-1 as
transport model
Abis interface uses E1/T1 as
transport model


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 96
Typical Configuration 2048TRX
Configration:1GIMS+1GMPS+
2GEPS
Support 2048TRX
Configuration A, Outer GBAM
Inner PCU
STM-1 is A interface physical
transport
E1/T1 is Abis interface physical
transport
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 97
Typical Configuration 2048TRX
Configuration:1GIMS+1GMPS+
2GEPS
Supports 2048TRX
Configuration B
Inner GOMU
Inner PCU
STM-1 is A interface physical
transport
E1/T1 is Abis interface physical
transport

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 98
Abbreviation
Physical Logical English Full Name
OMUb GOMU GSM Operation Maintenance Unit
GCUa GGCU GSM General ClocK Unit
SCUa GSCU GSM Switching and Control Unit
TNUa GTNU GSM TDM switching Network Unit
XPUa
GXPUM GSM extensible Processing Unit for Main service
GXPUT GSM extensible Processing Unit for Transmission
English Abbreviation English Full Name
GBCR GSM BSC Control Processing Rack
GBSR GSM BSC Service Processing Rack
GBAM GSM Back Administration Module
GMPS GSM Main Processing Subrack
GEPS GSM Extended Processing Subrack
GTCS GSM TransCoder Subrack
Cabinet and Subrack Abbreviation
Boards Abbreviation Collection
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 99
Abbreviation
Physical Logical English Full Name
DPUa GDPUC GSM Data Processing Unit for CS service
DPUc GDPUX GSM Data Processing Unit for eXtensible service
DPUd GDPUP GSM Data Processing Unit for PS service
EIUa
GEIUB GSM E1/T1 Interface Unit for aBis
GEIUP GSM E1/T1 Interface Unit for Pb
GEIUT GSM E1/T1 Interface Unit for aTer
GEIUA GSM E1/T1 Interface Unit for A
OIUa
GOIUB GSM Optic Interface Unit for aBis
GOIUP GSM Optic Interface Unit for Pb
GOIUT GSM Optic Interface Unit for aTer
GOIUA GSM Optic Interface Unit for A
FG2a
GFGUA GSM Fast ethernet and Gigabit ethernet Unit for A
GFGUB GSM Fast ethernet and Gigabit ethernet Unit for aBis
GFGUG GSM Fast ethernet and Gigabit ethernet Unit for Gb
GOUa
GOGUA GSM Optic Gigabit ethernet Unit for A
GOGUB GSM Optic Gigabit ethernet Unit for aBis
PEUa
GEHUB GSM E1/T1 High level Data Link Control Unit for aBis
GEPUG GSM E1/T1 Packet Unit for Gb
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

Page 100
This course mainly introduces three points as following:
BSC6000 V900R008 New Function and Features
BSC6000 V900R008 Hardware Structure and System Principle
of TC/BM separated & combination mode;
BSC6000 V900R008 Typical Configuration while TC/BM is
separation & combination mode
www.huawei.com
Thank You

S-ar putea să vă placă și