Sitepower range of products are cost-effective DC Power Supply System specially developed for the telecom industry. The cabinets are available as indoor cabinets, or for outdoor use with air-condition or fan cooling. The systems may be expanded with a battery extension cabinet to provide extra battery backup.
Sitepower range of products are cost-effective DC Power Supply System specially developed for the telecom industry. The cabinets are available as indoor cabinets, or for outdoor use with air-condition or fan cooling. The systems may be expanded with a battery extension cabinet to provide extra battery backup.
Sitepower range of products are cost-effective DC Power Supply System specially developed for the telecom industry. The cabinets are available as indoor cabinets, or for outdoor use with air-condition or fan cooling. The systems may be expanded with a battery extension cabinet to provide extra battery backup.
System System Power Cabinet options Certification Solutions 0,8m/3kW MicroPower Fancooled Power cabinet 3kW Battery ext cab 3kW 3 Eltek Sitepower range of products are cost-effective DC Power Supply System specially developedfor the telecom industry. The system mainly consists of a controller that monitors AC/DC rectifier modules and fused DC output distribution. The Sitepower System is available as 15kW in 2m cabinets, 9kW in 1,3m cabinets or 3kW in 0,8m cabinets. The cabinets are available as indoor cabinets, or for outdoor use with air-condition or fan cooling. The systems may be expanded with a battery extension cabinet to provide extra battery backup. In addition there is a wide range of kits designed for easy mounting in the power or battery cabinets to provide extra power or additional functions.
Sitepower 15kW/9kW/3kW, 48VDC systems 4 Site Power building blocks: Power cores Outdoor cabinets Indoor cabinets Power modules Batteries Optional kits 5 SitePower range Micro 0,8m System: Flatpack PSB Rectifier: Flatpack 1500 System monitor: Micropower controlcard Max.power: 3kW
Rev.2 7 MicroPower organization chart MicroPower 0,8m fancooled Power Cabinet 105417 Battery extension cabinet 105417 Battery Shelf kit 105420 AC kit for battery cabinet heater 105291 2nd BTS breaker 105424 Heater kit 105421 2-pole AC breaker 105422 Pole mounting kit 105273 Floor mounting kit 105288 Wall mounting kit 105287 OVP kit 105289 8 MicroPower General info: Mains: 115/230 VAC, 1 phase Power: 3kW Battery: 60Ah Fan cooled
Distribution options: Up to 2x40ADC load MCBs Up to 2x60A battery MCBs
9 Generic specifications (Micro) Up to 2 Flatpack 1500 rectifiers System voltage: 48 VDC Input voltage: 1 phase 230VAC ( ) 1 phase 115VAC ( ) Output power 3 kW Room for 1 battery shelf Protection: Soft start High voltage disconnect above 310 VAC 10 System Schematic (3kW Micro) 11 Flatpack 1500 rectifiers Input voltage: 85-310 Vac Output voltage: 24, 48 and 60 Vdc Power factor: > 99% Efficiency: > 91% Output power: 1500 W universal input Output current: 31 Amps Hold-up time: 20ms Operating Temp.: -40C to 70C (-40F to +158F) Dimensions: 214 x 243 x 41.5mm (8.8 x 9.8 x 1.64) (wxdxh) Dual Fan cooling
12 Flatpack 1500 312 185 150 85 0 200 400 600 800 1000 1200 1400 1600 0 50 100 150 200 250 300 350 Input Voltage (VAC) O u t p u t
P o w e r
( W )
The Rectifier will disconnect itself from the AC source above 312 VAC The Rectifier will Shutdown operation when AC is Below 85 VAC FP 1500 FP 700 13 Flatpack 1500 0 200 400 600 800 1000 1200 1400 1600 60 65 70 75 80 85 90 95 100 Ambient Temperature (deg C) M a x i m u m
A v a i l a b l e
P o w e r
( W a t t s )
The Rectifier will Start to derate output power at 70 C The Rectifier will Continue to output power up to 95 C 14 Flatpack 1500 Modelo de Rectificador Doble Ventilador LED Indicadores de Estado Informacin Operacional Ajuste de voltaje de salida Barra de segmentos de corriente de salida 15 Flatpack 1500 Diseo manual Forma de Gancho para ptimo agarre Fcil extraccin rectificadores Seguros en posicin insertado Mecanismo de liberacin Resorte metlico para expulsin Seguro metlico para retencin del gancho Durable y confiable
Flatpack Modularidad Gancho Integrado para extraccin 16 Flatpack 1500 Puntos de Entrada AC 17 Flatpack 1500 Puntos de salida DC (+) y (-) Conector Interface para control y comunicacin 18 Flatpack 1500 19 Flatpack 1500 Sntoma Posible error Cmo encontrar la falla, recuperar o reactivar el mdulo Todos los LEDs apagados (OFF) Desconexin normal. Paro externo. Tanto la entrada como la salida estn desconectadas desde las fuentes de poder. Pudo haberse apagado (OFF) el sistema de rectificacin por medio de la Unidad de Control y Monitoreo (MCU). Consulte el Manual del Usuario del Flatpack MCU en la seccin de Instrucciones de Operacin. LED de encendido activado (on), la grfica de barra led muestra la lectura mxima. Operacin normal. Fuerza o lmite de potencia o corriente durante la carga. Para asegurarse de que el modulo est bien, verifique el voltaje de salida que debe ser ligeramente ms bajo que el voltaje de flotacin. Mida la corriente que debe presentar una lectura mayor que la de la corriente nominal. Voltaje de salida bajo Reduccin de la capacidad normal debido a alta temperatura interna. Reduccin en la capacidad normal debido a bajo voltaje de entrada. Para verificar la reduccin en la capacidad normal por temperatura, determine la corriente mxima del rectificador del sistema. Lea la medicin de la corriente del rectificador en la pantalla de las unidades de monitoreo, si el valor mostrado por la unidad de monitoreo es menor que la corriente mxima del rectificador, lo ms probable es que el rectificador(s) haya reducido la capacidad normal de la potencia de salida debido a alta temperatura. Mida el voltaje de entrada. Cada Flatpack 1500enviar su potencia mxima de salida (1400W) a voltajes de entrada de 185Vac a 300Vac. Para voltajes de entrada de entre 150Vac y 185Vac, la reduccin en la capacidad normal se fijar en 1100W, para voltajes de entre 85Vac y 150Vac se reducir ms all de 550-600W. 20 Flatpack 1500 Sntoma Posible error Cmo encontrar la falla, recuperar o reactivar el mdulo LED de alarma (rojo) encendido ( on) Todos los dems LEDs apagados (OFF) Alarma de Mdulo:
Prdida de voltaje de entrada. Observe el sistema. Si todos los mdulos actan igual, los errores ms probables son: Falla de voltaje en la lnea de entrada. Verifique todos los fusibles del sistema o interruptores de circuito de toda la lnea de voltaje de entrada. Mida el voltaje de lnea. Si < 85 V ac , los mdulos pudieron haber ingresado al modo de proteccin contra baja alimentacin principal. Nota: Para voltajes de 78-85 V ac , algunos mdulos pueden entrar al modo de proteccin, otros no. Paro interno Proteccin contra sobre- voltaje. Si los mdulos actan diferente, los errores ms comunes son: Proteccin contra sobre-voltaje. Cada unidad monitorea su propio voltaje y se para si un error interno ocasiona que el voltaje de salida suba del nivel legal. Retire el rectificador del sistema y permtale que se restablezca por un minuto, despus, reconctelo. Si se enciende el LED verde y el LED de alarma se apaga (OFF), el rectificador ha asumido su operacin normal. Si el rectificador vuelve a la condicin de falla, debe retirarse para reparacin. Paro por alta temperatura Observe la temperatura ambiental. A temperaturas superiores a 70 grados, el rectificador puede pararse para evitar dao interno. Falla del ventilador Verifique que ambos ventiladores estn funcionando. Si no, retire el rectificador del sistema y reemplace el(los) ventilador(es), de acuerdo con la descripcin en la seccin Reemplazo de Ventiladores. Falla del mdulo Si ninguno de los casos anteriores resuelve su problema, probablemente sto se debe a una falla en el mdulo. Llame a servicio. LED de fuerza encendido (on), LED de alarma encendido (on) Error del mdulo Este modo se puede presentar por un corto tiempo, slo durante el encendido o apagado. De lo contrario, llame a servicio. 21 General System Arrangement 22 Block Diagram 23 AC Input Terminal Block Designed to mount OVP and 2 pole AC Breaker 24 DC Distribution 60 Amps Battery Breaker 1 pole 16 Load Breaker 2 pole 32 A Load Breaker Space for 2nd BTS Breaker Space for terminal block for an external battery backup 25 AC Mains Suppply 26 Lifting the cabinet Must not be lifted with the batteries fitted. 27 Drilling Template 28 Cable Entry Remove Battery Shelf. Demount cable glands, and mount them the correct way. Remove metal disc in cable glands to be used. Make a cut smaller than the cable diameter. Pull the cables. 29 Cable Access 30 AC Connections AC Ground Wire: 4 mm 2 to 10 mm 2. AC Cables: 4 mm 2 to 10 mm 2
31 Earthing System 32 Load and Battery Connections 33 Temperature Sensor 34 Alarm Relay Outputs 35 Fail Safe Operation 36 Con 1 & 6 Pin Assignments 37 Temp Compensated Batt Charging 54,48 VDC @ 20 o C; Slope 96 mV/ o C; 4 mV/ o C per cell 38 Changing Filter 39 Optional Kits (Micro) 2-pole AC breaker The Kit for AC mains circuit breaker makes it possible to cut the mains input inside of the system ad makes it possible to turn off the cabinet heater in the Power Cabinet. BTS distribution The BTS (Base Transceiver System) kit enables you to extend the system with 3- pole 63 A MCB, for additional BTS load. 40 2-pole AC Breaker 41 Optional Kits (Micro) Wall mounting OVP This kit enables you to install Over Voltage Protection into systems with both 1 and 3x230VAC or 3x400VAC+N. The OVP device protects the system from voltage spikes and surge currents. This kit enables you to mount the 3kW outdoor cabinet to the wall 42 OVP 43 Optional Kits (Micro) Heater kit Pole mounting kit The heater kit is intended for systems situated in cold climates If the cabinet temperature drops below a defined temperature the heater will be engaged. The Kit for Pole Mounting makes it possible to mount the PSB 3kW, Outdoor Power Cabinet to a pole 44 Optional Kits (Micro) AC kit for batt cab heater The AC kit for battery cabinet heater enables you to distribute AC feed for the heater into the battery cabinet . Plinth KIT The kit for Plinth makes it possible to fasten the Outdoor SitePower Cabinet securely to the ground/floor. The plinth is first fastened to the ground/floor and then cabinet is installed on top of the plinth. 45 Optional Kits (Micro) This kit enables you to expand your system with additional battery strings. battery string+indoor shelf 46 Conclusin