Mechanic Combi with thermostat Built-in produced at CARINARO (47) BCB.; IN CB. Problem Root Cause No perfect sealing on the evaporation ring. Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work, other than when undertaking specified observation checks.
Descriere originală:
Titlu original
EN_TB001502 Rev2_ Repair for Gas Leakage – Combi Built-In
Mechanic Combi with thermostat Built-in produced at CARINARO (47) BCB.; IN CB. Problem Root Cause No perfect sealing on the evaporation ring. Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work, other than when undertaking specified observation checks.
Mechanic Combi with thermostat Built-in produced at CARINARO (47) BCB.; IN CB. Problem Root Cause No perfect sealing on the evaporation ring. Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work, other than when undertaking specified observation checks.
Technical Bulletin TB001502 Title: Repair for gas leakage through the evaporation ring Combi Built-in Affected products: Mechanic Combi with thermostat Built-in produced at CARINARO (47) BCB.; IN CB What the Customer notes Hot fridge. Problem Root Cause No perfect sealing on the evaporation ring Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work, other than when undertaking specified observation checks. Spare Parts to be used Intervention to be done: 1) The product has been pressurized and internal leakage was detected (Fig. 1). Leave the capillaries and the return pipe disconnected from the compressor, because when the recovery operation of the internal circuit will be completed, before carrying out the vacuum and charging, the circuit cleaning should be performed. 2) Remove the condenser from the appliance by removing the four screws that secure it (Fig. 2).
Fig. 1 Fig. 2 Profile: General Issued: September 2014 Written by: F.L. Approved by: P.U. Revision: 02 Platform: Mechanic Combi with thermostat Factory: Carinaro (47) S/N: ALL 2 Technical Bulletin Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work, other than when undertaking specified observation checks. Intervention to be done: 3) At the height of 50 cm from the plinth (starting from above the compressor, see Fig. 3) and at 15 cm from the left side panel, make an opening of 10x15cm. Do not cut the plastic panel from all four sides, but leaving a hooked portion so as to close again as shown in Fig 4. 4) Free the ring from the foam so you can make the repair (Fig. 4) 5) Cut the aluminum tube no more than 2 cm from the ring, and cut the capillary (Fig. 5 and Fig. 6) 6) Pull down with a pliers the capillary so as to approach the latter to the aluminum tube to do the repair (Fig. 7).
TB001502 Fig. 3 Fig. 4 Fig. 6 Fig. 5 Fig. 7 15 cm 50 cm 10 cm 15 cm Title: Repair for gas leakage through the evaporation ring Combi Built-in Affected products: Mechanic Combi with thermostat Built-in produced at CARINARO (47) BCB.; IN CB Profile: General Issued: September 2014 Written by: F.L. Approved by: P.U. Revision: 02 3 Technical Bulletin Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work, other than when undertaking specified observation checks. Intervention to be done: 7) You can perform the leakage repair in two ways: with welding: insert the capillary inside the aluminum tube for a maximum of 2 cm (Fig. 8 and Fig 9). Put a protective plate behind the point to be welded to avoid causing damage to the appliance (Fig. 10). Perform welding between copper and aluminum using the alloy C00143875 (Fig. 11 e Fig. 12).
TB001502 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Title: Repair for gas leakage through the evaporation ring Combi Built-in Affected products: Mechanic Combi with thermostat Built-in produced at CARINARO (47) BCB.; IN CB Platform: Mechanic Combi with thermostat Factory: Carinaro (47) S/N: ALL Profile: General Issued: September 2014 Written by: F.L. Approved by: P.U. Revision: 02 4 Technical Bulletin Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work, other than when undertaking specified observation checks. Intervention to be done: with lokring: put glue on both ends of the pipes and place the lokring paying attention to align the same with the two pipes to be connected. Clamp the connector (Fig. 13 and Fig. 14). 8) To reduce the noise produced during operation, noise due to the expansion of the gas, you can apply soundproof material (C00306744 - TEROSTAT 82) to the weld or to the lokring ring as shown in Figure 15. Place the pipes back into the appliance. 9) To insulate the parts where the insulating material was removed, use the foam caring to counteract the expansion of the polyurethane foam, using properly secured jigs (made of cardboard, wood, etc.). This contributes to a better density of the foam, as well as to avoid that any foam leak may soil the cabinet (Fig. 13). 10) Apply some silicon to let the plastic panel previously opened adhere well and close properly securing it with tape. 11) Replace the filter then weld it again 12) Reposition the condenser; do an empty and recharge of the product. TB001502 Fig. 13 Fig. 14 Fig. 16 Title: Repair for gas leakage through the evaporation ring Combi Built-in Affected products: Mechanic Combi with thermostat Built-in produced at CARINARO (47) BCB.; IN CB Platform: Mechanic Combi with thermostat Factory: Carinaro (47) S/N: ALL Fig. 15 Profile: General Issued: September 2014 Written by: F.L. Approved by: P.U. Revision: 02