Sunteți pe pagina 1din 61

ZXG10 B8018 Hardware Architecture

ZTE University

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Object

Learning this course, you will be able to:


Describe the features of ZXG10 B8018
Outline the hardware structure of ZXG10 B8018
Master the functions and hardware modules of
ZXG10 B8018
Master the typical configuration of ZXG10 B8018

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Contents

ZTE University

Overview

Hardware system

Typical configurations

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Position in Mobile Network

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Technical features

Large system capacity and high performance

Capacity: 18 TRX/rack
Largest site type: O54 or S18/18/18
Support 6 cells

Ability

of

cascades:

Support

4-level

cascaded

networking
Support 8 E1/T1 interface

Supports functions and channel encoding modes of


GPRS CS1 - CS4
EGPRS MCS1 - MCS9

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Technical features

Supports the following circuit-type voice services:

Full-rate voice service


Enhanced full-rate voice service
Half rate voice service

AMR voice service

Supports the following circuit-type data service:


9.6 kbps full-rate data service

4.8 kbps full-rate data service


2.4 kbps full-rate data service

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Technical features

Compatible with the following standards:

GSM Phase I
GSM Phase II
GSM Phase II +

Supports modules of different frequency bands in one


cabinet.

Supports GMSK and 8PSK modulation

Supports automatic bridge circuit protection

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Technical features

Employ Dual Transciever Unit (DTRU) technology.

Support combined cabinet capacity expansion with


ZXG10-BTS (V2)

Support 4-way diversity reception

Support Tandem Free Operation (TFO) version 5

Provides common BCCH support, that is, same cell


supports carrier frequency of two frequency bands sharing

one BCCH.

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Technical features

Abis interface supports following networking modes:

Star
Chain
Tree

Ring

Um interface supports A51/A52 encryption algorithm

Support Dual Power Combining Transmission (DPCT)

Support Delay Diversity Transmission (DDT)

Advanced IP based Abis Interface

Safe and agile power management subsystem

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Contents

ZTE University

Overview

Hardware system

Typical configurations

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Logical structure
Baseband
Signal

Control
Signal

RF
Signal

Antenna Feeder
Processor

System
Clock

RF
Signal

RF Uni t

Baseband
Processor

Controll er &
Mai ntenance Uni t

Abi s Interface

B
S
C

Data
Link

Um
Interface

System
Clock
Power Distribution Module

-48V or +24VDC

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Hardware structure

ZXG 10- B8018 (V 1.0)


DTRU0
MMI

BSC

Abis
EIB/FIB
Interface

Environment
Monitor

CMB

PDM

DTRU1
.
.
.

A
E
M

Um
Interface

DTRU8
FCM

Power
Input

ZTE University

Internal communication interface (including control


signaling, data flow, clock signal and so on)

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Rack structure

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Internal connections
Power
Input

-48

PDM
Control

Frame

ABIS Interface(8 line


E1/T1 or one 100
Mbps Ethernet)

DIDB

8M HW,clock
and intellegent
power ON/OFF

Site
ID
ID

88E1/T1
E1/T1

8 MHW
Only applied on FIB
Synchronization
Power and interface control
clock I/O
Monitor interface
LMT serial
interface, network interface

FCLK and 13 M Hz test clock


EIB / FIB

Fan
3
3

CMB
(TDM Switching)

DFCM

DFCM working power and alarm collection

+12V/-12V

AEM0 alarm
AEM1 alarm AEM2 alarm
Fan
3
3

AEM2

AEM1

DTRU2

DTRU1

DTRU0

AEM0

Antenna
Feeder

Transceiver
frame 3

DFCM

DFCM working power and alarm collection

+12V/-12V

AEM0 alarm
AEM1 alarm AEM2 alarm
Fan
3
3

AEM2

AEM1

DTRU2

DTRU1

DTRU0

AEM0

Antenna
Feeder

Transceiver
frame 2

DFCM

DFCM working power and alarm collection

AEM0 alarm
AEM1 alarm AEM2 alarm

ZTE University

AEM2

AEM1

DTRU2

DTRU1

DTRU0

AEM0

Antenna
Feeder

Transceiver
frame 1

+12V/-12V

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Software structure

dCMM
system power-on initialization

downloads all board software


operation, maintenance and
management

dCMM

dFUC

dCHP

dFUC and dCHP

service processing
baseband signal processing

FIU

FIU
Abis

dTRX
BTS B8018 Software System

connection with BSC


working flow control
resource
management
ZTE University

configuration

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Function of CMB

Provides eight E1/T1 interfaces.

Implements switching of thirty-two 2 M HW time slots


with 2 bit switching array.

Provides transparent passage for external environment


alarm.

Provides all kinds of clock needed in BTS; including


clock signal of 13 MHz, 2.048 MHz, 60 ms, 8K_8MW, 8

MHz, 16 MHz and so on.

Detects, controls, and maintains the whole BTS system,


support near-end and far-end management interface.

Monitoring and control of each board running status

Board provides active/standby switching

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Functional structure of CMB

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Panel and indicator of CMB


LED

Color

Name

Meaning

Working Mode

Green/Red

PWR

Power LED

Green ON: Normal


Red ON: Alarm
OFF: Power off or other reasons

Green

RUN

Running LED

Green flashing at 4 Hz: Boot is running


Green flash at 1 Hz: Application is running
Others: System is abnormal
Green ON: Synchronization clock of the Abis interface network
Green flashing at 1 Hz: Synchronization clock of the SDH network
Red flashing at 1 Hz: E1 frame out-of-sync alarm
Red ON: E1 line is broken or not connected
OFF: Free running

Green/Red

SYN

Clock synchronization
mode LED

Green/Red

CLK

Clock LED

Green ON: Network synchronization is locked


Green flashing at 1 Hz: Locking the phase
Red ON: Clock fault

Green

MST

Active/Standby LED

Green ON: Active state


Green OFF: Standby state

OFF: Running normally


Green flashing at 1 Hz: System initialization (Low).
Green flashing at 4 Hz: software loading

Green/Red

STA

Status LED

Red flashing at 1 Hz: LAPD link disconnection (High).


Red flashing at 4 Hz: HDLC link disconnection (Low).

Red ON: Other alarms (such as temperature, clock and frame


number alarms)

CMB
PWR RUN SYN CLK MST STA

ZTE University

M/S

RST FPWR

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Function of EIB

Provide line impedance matching of 8 E1/T1

Signal isolation at IC side and line side

Line protection at E1/T1 line interface

Bypass function of E1/T1 line.

Provides type information of interface board to CMU

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Structure and panel of EIB

EIB

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Function of PDM

PDM distributes the -48 V power to CMBs,


DTRUs and FCMs, and provides overload
protection via circuit breakers. In addition to

a circuit breaker for each module, a main


switch circuit breaker is placed at the -48 V
input end on the top of the BTS cabinet.

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Functional structure of PDM

PWR

Circuit
breaker

48V

Filter

TRM/ETRM1
.
.
.

12
TRMs/
ETRMs

TRM/ETRM12
CMM1
2 CMMs

PWRGND

CMM2

-48VGND

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Panel of PDM

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Function of DTRU

Processes 2 carriers at maximum in downlink:


Complete rate adaptation
Channel coding and interleaving
Encryption
Generating TDMA burst pulse
Complement GMSK/8PSK modulation
Digital up-conversion of the two carriers

Processes 2 carriers at maximum in uplink:


Implement uplink digital down conversion
Diversity combining of receiver
Digital demodulation (GMSK and 8PSK demodulation, equalization)
Decrypting
De-interleaving
Rate adaptation

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Function of DTRU

Implement processing of uplink and downlink RF


signal.

Receive switching signal of CMB to complete power

ON/OFF of module.

Support online update and load of software version,


support version update of programmable device.

Detect working state of module, collect alarm signal in


real time and report it to CMB.

Support RF frequency hopping, DPCT, downlink

transmission diversity, and four diversities reception in


ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

DTRU panel and indicators


DTRUG
TX1
RXM1
TXcom

RXD1

TX2
PWR

Identifier

Meaning

RXM1

Receiver 1

RXD1

Receiver 1 (for diversity)

RXM2

Receiver 2

RXD2

Receiver 2 (for diversity)

TX1

Transmitter 1

TX2

Transmitter 2

TXcom

Transmitter Combiner

ETP

Extend Test Port

RUN
MOD
ACT1
ACT2

RXM2

RXD2

Identifier

Full Name

Meaning

PWR

Power

Power LED

RUN

Run

Running LED

MOD

Model

BCCH mode LED

ACT1

Active

Channel activation LED1

ACT2

Active

Channel activation LED2

STA

State

Status LED

RST

Reset

Reset button

STA
RST

ETP

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Function of AEM

Combines the transmit signals of multiple carriers.

Provides bidirectional signal channels from the


BTS to the antenna for the transmitting band and
from the antenna to the BTS for the receiving band.

Gives an alarm when the VSWR of the antenna


port deteriorates.

Suppresses the interference out of the working


band and spurious emission.

Flexibly configures carriers.

Implements diversity receiving.

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Panel and indicators of CDU

ZTE University

LED
Position

Color

Name

Meaning

Working Mode

Green

FPO

Forward power output


LED

ON: Normal
OFF: Abnormal

Red

SWR1

VSWR level-1 alarm


LED

ON: There is an alarm


OFF: There is no alarm

Red

SWR2

VSWR level-2 alarm


LED

ON: There is an alarm


OFF: There is no alarm

Green

PWR

LNA power supply LED

ON: Normal
OFF: Abnormal

Red

LNA

LNA alarm LED

ON: There is an alarm


OFF: There is no alarm

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Functional structure of CDU

ZTE University

Identifier

Full Name

Meaning

ETX

Extended TX

Extended TX port

RTE

Radio Test Equipment

Radio test port

TX1

Transmitter 1

Combiner input 1 (PA output signal)

TX2

Transmitter 2

Combiner input 2 (PA output signal)

RX1

Receiver 1

Low noise amplifier output port 1

RX2

Receiver 2

Low noise amplifier output port 2

RX3

Receiver 3

Low noise amplifier output port 3

RX4

Receiver 4

Low noise amplifier output port 4

ERX1

Extend Receiver 1

Low noise amplifier extended output port 1

ERX2

Extend Receiver 2

Low noise amplifier extended output port 2

ANT

Antenna

Antenna feeder port

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Panel and indicators of ECDU

ZTE University

LED

Color

Name

Meaning

Working Mode

Green

FPO

Forward power
output LED

ON: Normal
OFF: Abnormal

Red

SWR1

VSWR level-1
alarm LED

ON: There is an alarm


OFF: There is no alarm

Red

SWR2

VSWR level-2
alarm LED

ON: There is an alarm


OFF: There is no alarm

Green

PWR

LNA power supply


LED

ON: Normal
OFF: Abnormal

Red

LNA1

Channel 1 LNA
alarm

ON: There is an alarm


OFF: There is no alarm

Red

LNA2

Channel 2 LNA
alarm

ON: There is an alarm


OFF: There is no alarm

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Functional structure of ECDU

ZTE University

Identification
Symbol

Full Name

Meaning

RTE

Radio Test Equipment

Radio test port

RX1

Receiver 1

Low-noise amplifier output port 1

RX2

Receiver 2

Low-noise amplifier output port 2

RXD1

Receiver for Diversity1

Low-noise amplifier output port 1


(diversity)

RXD2

Receiver for Diversity2

Low-noise amplifier output port 2


(diversity)

ANT

Antenna

Antenna feeder port

ANTD

Antenna for Diversity

Antenna feeder port (diversity)

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

CEU and CEU/2 panel


CEUG/2

CEUG
OTX1

OTX1
ERX1
TX1
RX1

TX2
RX2

ERX2

OTX2

ERX2
OTX2
TX3

RX3
TX3

TX4

RX4
TX4

CEU
ZTE University

CEU/2

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

CEU functional structure

ZTE University

Identifier

Meaning

Description

OTX1

Output TX 1

Combiner TX output port 1

OTX2

Output TX 2

Combiner TX output port 2

TX1

Transmitter 1

Combiner input 1 (PA output signal)

TX2

Transmitter 2

Combiner input 2 (PA output signal)

TX3

Transmitter 3

Combiner input 3 (PA output signal)

TX4

Transmitter 4

Combiner input 4 (PA output signal)

RX1

Receiver 1

Splitter output port 1

RX2

Receiver 2

Splitter output port 2

RX3

Receiver 3

Splitter output port 3

RX4

Receiver 4

Splitter output port 4

ERX1

Extend Receiver 1

Splitter input port 1 (low noise amplifier extended


output)

ERX2

Extend Receiver 2

Splitter input port 2 (low noise amplifier extended


output)

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

CENU and CENU/3 panel


CENUG

CENUG/3

RX1
OTX1
RX2

RX1
OTX1
RX2

ERX1

TX1

RX3

ERX1
RX3

TX2

RX4

RX4

TX3

RX5

OTX2

RX6

RX5

OTX2

RX6

ERX2

TX4
ERX2

RX7

RX7
TX5

RX8

TX5
RX8

TX6

CENU

TX2

TX3

TX4

ZTE University

TX1

TX6

CENU/3

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Structure of CENU and CENU/3

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

CENU/2 and CENU/4 panel


CENUG/2

ERX1

CENUG/4

OTX1
ERX1

RX1

RX1

TX1

TX1

TX2
RX2

TX2
RX2

TX3

ERX2

OTX2

RX3

TX3

ERX2

TX5

TX6

CENU/2
ZTE University

OTX2

RX3

TX4

RX4

OTX1

TX4

RX4

TX5

TX6

CENU/4

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Structure of CENU/2 and CENU/4

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Cabinet top

1: PE
2: PWRTA_L1
3: PWRTA_L2
4: PWRTA_L3
5: 13 MHz Clock
6: FCLK
7: RJ45
8: E1 PORT

ZTE University

9: E1 PORT
10: RELAY_ALM
11: ID PORT
12: HYCOM1
13: HYCOM2
14: HYCOM3
15: HYCOM4
16: HYCOM5

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

17: HYCOM6
18: HYCOM7
19: HYCOM8
20: HYCOM9
21: HYCOM10
22: HYCOM11
23: HYCOM12

univ.zte.com.cn

The ID switch
15

14

13

12

11

10

SATE

Whether to use the satellite


Abis link or not

BTS_TYPE

BTS_NO

SLAVE1_
PORT

SLAVE2_
SATE
PORT

ABIS_PORT

ABIS_TS

BTS_TYPE

1100: B8018

1101: B8112

1110: M8202

1111: M8204

No. of the cabinet of the


same site

00: Basic cabinet

01: Extended cabinet 1

10: Extended cabinet 2

ZTE University

The E1 port of the basic cabinet to


connect extended cabinet 1

BTS_NO

SLAVE1_PORT

00: Port E of the basic cabinet

01: Port F of the basic cabinet

10: Port G of the basic cabinet

11: Port H of the basic cabinet

SLAVE2_PORT

The E1 port of the basic cabinet to


connect extended cabinet 2

00: Port E of the basic cabinet

01: Port F of the basic cabinet

10: Port G of the basic cabinet

11: Port H of the basic cabinet

0: Common Abis

1: Satellite Abis

ABIS_PORT

O&M port number

00: Port A

01: Port B

10: Port C

11: Port D

ABIS_TS

The O&M LAPD timeslot on


the Abis interface

000: TS16

001: TS31

010: TS30

011: TS29

100: TS28

101: TS27

110: TS26

111: TS25

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Contents

ZTE University

Overview

Hardware system

Typical configurations

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Star mode
SITE0
B
S
C

SITE1
.
.
.
SITEn

Since the signal transmission is through fewer intermediate links


Along the path, the reliability of transmissions is higher.
Deployed in densely populated areas

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Chain mode

BSC

SITE 0

SITE 1

SITE 2

Applicable to one site multi BTS situations


Since the signals goes through more links, the line reliability is
relatively poor than star networking

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Tree mode

SITE 1
SITE 0

SITE 2

B
S
C

SITE n

Line reliability is relatively low,the fault from the upper levelsite can
Affect the proper running of the lower level site
Mostly deployed in large areas with less population
ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Ring mode
BSC

SITE 0

SITE 1

SITE 2

SITE 3

Each line denotes a bidirectional E1 connection. The DIP switches


Settings of BTS should be according to the background configurations
All the nodes are connected in closed loop, it can span larger distances
then other types of networks. The reliability is higher; as it strays connect
with the BSC through the other end, if the link is broken from one place.
It can deployed in suburb and rural places
ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Modules for Different frequecies

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

AEM position

PDM

The marked positions for


CEU/2

A
E
M

CENU/3
CENU/4

D
T
R
U

EIB
CMB
CMB
FCM
D
T
R
U

D
T
R
U

A
E
M

A
E
M

A
E
M

A
E
M

A
E
M

A
E
M

FCM
A
E
M

D
T
R
U

D
T
R
U

D
T
R
U
FCM

A
E
M

ZTE University

D
T
R
U

D
T
R
U

D
T
R
U

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

O1 configuration

Four-way diversity

Using ECDUs

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

O1 configuration

Two-way diversity

Using CDUs

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

O2 configuration

Through combiner
TX/RX

CDU

DTRU

TX/RX

CDU
TX1

ETX1

RXM1

ETX1
TX-COM

TX1

TX1

CDU

ANT

ANT

CDU

RXD1

RTE

TX2

TX2

RTE

TX2

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

RXM2

ANT

RXD2

ANT

RX1

RX1

RX2

RX2

RX3

RX3

RX4

RX4

ERX1

ERX1

ERX2

ERX2

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

DTRU

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

O2 configuration

Not through combiner

TMA

TMA

TX/RX

CDU

DTRU

CDU

TX/RX

TMA

TMA

TX1
ETX1

RXM1

ETX1
TX-COM

TX1

TX1

CDU

RXD1

RTE

TX2

TX2

RTE

ANT

ANT

CDU

TX2

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

RXM2

ANT

RXD2

ANT

RX1

RX1

RX2

RX2

RX3

RX3

RX4

RX4

ERX1

ERX1

ERX2

ERX2

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

DTRU

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

O4 configuration

TX/RX

CDU

DTRU

DTRU

RXM1

RXM1

TX2

ANT

CDU

TX1

RXD1

RXD1

RTE

ETX1
TX-COM

TX-COM

TX1

CDU
TX1

TX1
ETX1

TX/RX

TX2

TX2

RXM2

RXM2

RXD2

RXD2

RTE

TX2

ANT

CDU

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

ANT

RX1

RX1

RX2

RX2

RX3

RX3

RX4

RX4

ERX1

ERX1

ERX2

ERX2

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

TX1 TX2

DTRU

ZTE University

ANT

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

TXCOM RXM1

RXD1 RXM2

RXD2

DTRU

univ.zte.com.cn

O6 configuration

Using CEU/2
TX/RX

ANT

CDU

CDU

DTRU

DTRU

TX1

TX1
ETX1

RXM1

RXM1

RTE

TX2

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2

TX1

TX1

TX2
RX2

RTE

TX2

OTX1

OTX2

CEU/2

TX1 TX2 TX3 TX4


ANT

RXM2

RXD2

RXD2

RXD2

RX1

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2

ETX1

TX2

RXM2

ANT

RX1

RXD1

RXM2

CDU

OTX1

TX- COM

TX2

TX2

CDU

CEU/2

RXM1

RXD1

RXD1

ERX1
TX1

TX- COM

TX- COM

TX1

DTRU

TX/RX

ERX1

ERX2

RX1 RX2 RX3 RX4

ANT
ERX2

TX1 TX2

RX1

OTX2
RX2

TX3

RX3
RX4

RX3

TXCOM RXM1

RXD1 RXM2

RXD2

DTRU

RX2
RX3
RX4

TX4
ERX1
ERX2

RX4

ERX1
ERX2

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

TX1 TX2

DTRU

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

TXCOM RXM1

RXD1 RXM2

RXD2

DTRU

univ.zte.com.cn

O6 configuration

Using CENU/4
TX/RX

CDU

DTRU

DTRU

ETX1

RXM1

RXM1

RTE

ANT

RXD2

RXD2

RXD2

RX1

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2

TX1

TX2
RX2

RTE

TX2

OTX1

TX3
RXM2

OTX2

CENU/4

ERX1

ERX2

TX1 TX2 TX3 TX4 TX5 TX6 RX1 RX2 RX3 RX4
ANT
ERX2

RX1

TX1 TX2

OTX2
RX2

TXCOM RXM1

RXD1 RXM2

RX2

TX4

RX3
RX4

ANT

RX1
TX2

RXM2

CDU

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2

ETX1

RXD1

RXM2

ANT

CDU

TX1

TX- COM

TX2

TX2

CDU

OTX1

RXM1

RXD1

RXD1
TX2

CENU/4

ERX1

TX1

TX- COM

TX- COM

TX1

DTRU

TX1

TX1

TX/RX

RX3

DTRU
RX3
RX4

TX5
ERX1
ERX2

ERX1

RX4
TX6

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

TX1 TX2

DTRU

ZTE University

TXCOM RXM1

RXD1 RXM2

RXD2

ERX2

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

DTRU

univ.zte.com.cn

RXD2

O8 configuration

TX/RX
CDU

DTRU

DTRU

ETX1

RXM1

RXM1

TX2

RTE

ANT

ETX1

TX1

TX-COM

TX2

RXM2

RXM2

RXM2

RXD2

RXD2

RXD2

TX2
RX2

RTE

ANT

CDU

TX2

ANT

CDU

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2

ANT
ERX2

RX1

TX1

RX1

RXD1
TX2

TX2

OTX1

RXM1

RXD1

RXD1

CDU

ERX1
TX1

TX-COM

TX-COM

TX1

CEU/2

DTRU
TX1

TX1

TX/RX

RX1

OTX2
RX2

RX2

TX4

RX3

RX3

RX4

RX3
RX4

TX5
ERX1

RX4

ERX2

OTX1

ERX1

OTX2

CEU

TX1 TX2 TX3 TX4


CEU
ERX1

ERX1

ERX2

OTX1

OTX2

CEU

ERX1

ERX2

ERX2

RX1 RX2 RX3 RX4

TX1 TX2 TX3 TX4

RX1 RX2 RX3 RX4

DTRU
TX1

OTX1
RXM1

TX1
RX1

TX-COM

TX1 TX2

RXD1

TX2

TXCOM RXM1

RXD1 RXM2

RXD2

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

TX2

RX2

DTRU

DTRU

RXM2
RXD2

ERX2
OTX2
TX4

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

TX1 TX2

TXCOM RXM1

RXD1 RXM2

RXD2

RX3
TX5

DTRU

DTRU

RX4

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Voltage and Power Consumption


Table: ZXG10 B8018 (V1.00) voltage and power consumption.
Characteristics

Parameters

Voltage

Required working
voltage
Range

Values
48 V DC
40 V DC (Minimum)
57 V DC (Maximum)

Power
Consumption
(fully configured:
3400 W for 40W)

TRM (18)

160 W per TRM

ETRM

175 W per ETRM

CMM (2)

16 W per CMM

AEM (9)

5 W per AEM

Fan (3)

60 W per Fan

Power consumption 3750 W (60W)


ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Heat Dissipation
Characteristics
Heat dissipation (full
configuration of each
carrier shelf: 600 W)

Parameters

Values

TRM (18)

120 W per TRM

ETRM

135 W per ETRM

AEM (9)

45 W per AEM

CMM (2)

20 W per CMM

Fan (3)

30 W per Fan

Heat dissipation in full configuration is as below:


Without ETRM, heat dissipation of integrated equipment is less than 2200 W
With ETRM, heat dissipation of integrated equipment is less than 2350 W

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Reliability
Table ZXG10 B8018 (V1.00) Reliability Specifications
Characteristics

Values

Mean Time Between Failures


(MTBF)

6.310000 hours(7 Yrs)

Mean Time to Repair (MTTR)

34 min. 12 sec.

Availability Ratio (A)

99.9991 %

Average Interruption time per


year

4 min. 48 sec.

The product successfully passed the CE certification. It complies with international standards
related to personal safety, electromagnetic security (EMC) and wireless frequency spectrum.
Table 12 explains the specifications.

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

Physical characteristics

Grounding resistance-The case rack should be grounded well, with


grounding resistance 5 ohm at most
ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

RF Indices

Output power-ZXG10 8018 supports 40W power for 8PSK


and 60W for GMSK

Static sensitivity-the static receiving sensitivity of ZXG10

8018 reaches upto -112 dbm. The high sensitivity


gurarantees the uplink channel performance and is one of
the prerequisites for a wide coverage

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

ZTE University

The information contained in the file is solely property of ZTE corporation. Any kind of disclosing without permission is prohibited.

univ.zte.com.cn

S-ar putea să vă placă și