INVERTER-Y

TRAINING 2009

Inverter-Y Training 2009

TOPICS

Introduction to Y-Inverter
Control Algorithm
Troubleshooting

Inverter-Y Training 2009

INTRODUCTION

Inverter-Y Training 2009

INTRODUCTION

What is inverter ?
What are the advantages ?
Differences between Conventional &
Inverter A/C

Basics of Inverter Technology


Inverter-Y Training 2009

INTRODUCTION
What is Inverter?

Electrical supply has fix frequency

Inverter type air conditioner have frequency changer


which can change the electrical frequency to control
the speed of the compressor

This in turn, can control the capacity accordingly

Inverter-Y Training 2009

INTRODUCTION
Advantages

Enhanced room temperature comfort


- More precise room temperature control
- Temperature fluctuation is kept within 0.5C from set temperature

Conventional

Inverter

Inverter-Y Training 2009

INTRODUCTION
Advantages

Less on / off cycle


Conventional compressor

Compressor capacity

Room temperature
control:
switching compressor
ON & OFF

Full capacity

Time

Compressor
capacity

Smooth ramp up
from zero to high
rotational speed

Inverter

Slow down
as
temperature
drops

Inverter-Y Training 2009

Maintain room
temperature at low
speed

Room temperature
control:
Control compressor
rotational speed
smoothly

Time

INTRODUCTION
Advantages

Starting frequency
Compressor
frequency
(rps)

1.0 hp 68 rps
1.5 hp 74 rps

Max.
55
35

Target frequency

20
0

Time (min)
1 2
6

Inverter-Y Training 2009

INTRODUCTION
Advantages

Fast cooling
Conventional
non-inverter
A/C
Inverter A/C
Room
temperature

Set temperature

Time

Quick
cooling

Inverter-Y Training 2009

INTRODUCTION
Advantages

Low starting current


Running
current

Conventional A/C:
High starting current
Frequent on/off cycle

Inverter A/C:
Low starting current
Smooth operation

Hours of operation

Inverter-Y Training 2009

INTRODUCTION
Advantages

Higher reliability

Less compressor start stop cycle


Low starting current

Longer compressor motor lifespan

Inverter-Y Training 2009

INTRODUCTION
Advantages

Low energy consumption with superior efficiency

Frequency of supply current is varied according to load


requirements excellent efficiency

Range is between
0 68 rps (204 Hz) for 1.0 hp
0 74 rps (222 Hz) for 1.5 hp

Lowest operating frequency = 60 Hz

Resulting in significantly LESS compressor start/stop low


energy consumption

Inverter-Y Training 2009

INTRODUCTION
Advantages

Protection
Additional software protection against

Over current
Over heating

Inverter-Y Training 2009

INTRODUCTION
Differences Overview

Description

Inverter A/C

Outlook feature

Conventional A/C

Almost same

Controller

Variable
frequency control

Relay sequence
control

Compressor

Inverter 3-Phase

1 or 3-Phase

Frequency

0 ~ 204/222 Hz

50 or 60Hz

Inverter-Y Training 2009

INTRODUCTION
Basics of Inverter Technology

Inverter-driven
Compressor
IPM (Inverter
Power Module)

Inverter-Y Training 2009

Electronic Expansion
Valve (EXV)

INTRODUCTION
Basics of Inverter Technology

Power
supply

Rectifier
circuit

IPM

Compressor
Motor

Adjust capacity according to actual load by


Controlling the EXV opening
Controlling the refrigerant flow

Inverter-Y Training 2009

INTRODUCTION
Basics of Inverter Technology
Inverter system block diagram

Energy
Source

Rectifying
Circuit

Inverter
Circuit

Control &
Protection
Circuitry

Inverter-Y Training 2009

Compressor

Feedback

INTRODUCTION
Basics of Inverter Technology
Inverter drive power circuit

IN

U
V
W

Rectifier

Inverter-Y Training 2009

Inverter

OUT

INTRODUCTION
Basics of Inverter Technology
What are Rectifier / Inverter?

Rectifier:
Rectifying with smoothing
Changing AC DC
Inverter:
Inverse transformation with P.W.M.
Changing DC AC

Inverter-Y Training 2009

INTRODUCTION
Basics of Inverter Technology
Inverter drive power circuit - components

IN

U
V
W

Diode

Reactor

IPM(Inverter Module)
Electrolytic capacitor

Inverter-Y Training 2009

OUT

INTRODUCTION
Basics of Inverter Technology
The system
Inverter Output
Frequency

Power supply
Input frequency
50Hz
u
t

Inverter
AC/DC
Rectifier

222 Hz
t1
DC/AC
Inverter

50 Hz

Inverter-Y Training 2009

t
222 Hz

IPM

60 Hz

60 Hz

compressor
motor input

INTRODUCTION
Basics of Inverter Technology
Indoor PCB

Inverter-Y Training 2009

INTRODUCTION
Basics of Inverter Technology
Outdoor PCB

Inverter-Y Training 2009

CONTROL ALGORITHM

Inverter-Y Training 2009

CONTROL ALGORITHM
Frequency Principle

The compressor is frequency-controlled during normal


operation. The target frequency is set based on
following parameters:
i) Outdoor ambient temperature
ii) Set temperature
iii) Room temperature

When the frequency increases, the rotation speed of


compressor increases resulting in an increased
refrigerant circulation, this lead to higher amount of
heat transfer and vice versa when frequency
decreases.

Inverter-Y Training 2009

CONTROL ALGORITHM
Operating Modes

The system has 2 operating modes. The mode selection


is done in Inverter (indoor) controls.

The operating modes are:


Cool
Fan

Inverter-Y Training 2009

CONTROL ALGORITHM
Function Cool Mode

When Tr >= Ts 1.5C


- Comp, ID Fan and OD Fan ON

When Tr <= Ts - 2C
- Comp and OD Fan OFF
- ID Fan remain ON

Tr = Room Temperature
Ts = Set Temperature

Inverter-Y Training 2009

CONTROL ALGORITHM
Function Cool
Mode

At beginning of cooling operation, compressor


frequency will be increased smoothly to the target
frequency so that the room temperature is reduced.
When set temperature is achieved, operation
frequency will be reduced to stabilize the room
temperature.

Inverter-Y Training 2009

CONTROL ALGORITHM
When will Compressor Stop?

When cooling load is too small, even with lowest

operation frequency and the room temperature still fall


below compressor cut off point, compressor will stop.
Compressor Capacity

Lowest Freq
Time
Tr <= Ts - 2C
Comp will stop

Inverter-Y Training 2009

CONTROL ALGORITHM
Function - Fan Mode

Only High, Medium and Low fan speeds are allowed.


When changing cool mode to fan mode, the compressor
will stop and OD fan stops after 30s.
Compressor will only ON if the minimum stop time is > 3
minutes and the user change back to cool mode.
Fan speed will maintain same as during fan mode.

Inverter-Y Training 2009

PROTECTION
Protection Control - Data Communication Error
Between Indoor and Outdoor

Master by outdoor unit.


Indoor controller board will transmit signal to outdoor
controller board every 0.5s. Outdoor unit will response to
indoor once the valid data is received.
Indoor

Acknowledge

Send Signal

Outdoor

Inverter-Y Training 2009

PROTECTION
Protection Control - Data Communication Error
Between Indoor and Outdoor

If the data communication line between indoor and outdoor


occurs error for 15s continuously, compressor will
stop, OD fan stop after 30s. ID LED blinks error.
If the communication resumes after 15s, error code is clear
and compressor restarts after 3 minutes.
If the communication is not resume after 15s, unit unable to
restart and the error keep blinking.

Inverter-Y Training 2009

PROTECTION
Indoor Coil Frost Prevention

Only available in cooling mode.


When the indoor coil temperature < 2C, the compressor
starts to drop the frequency.
This protection is activated when:
- Indoor coil temperature < 0C for more than 180s.
Compressor will stop, OD fan stop after 30s and indoor
fan can only run at super low fan speed.
The unit can only be restarted after 3 minutes.
When the indoor coil temperature >13C, the
compressor frequency will be reset based on the OD
ambient, room and set temperature.

Inverter-Y Training 2009

PROTECTION
Input Current Control

No. Unit Capacity I1


1 1.0HP
9.5A
2 1.5HP
10A

Inverter-Y Training 2009

I2
6.5A
7A

I3
5.5A
6A

PROTECTION
Input Current Control

When the input current for running compressor exceeds


I2, running frequency will be reduced by 1 step. If current
still exceeds I2, frequency will be reduced by another 1
step until total current falls between I2 and I3.
This protection is activated when the input current
exceeds I1 for 2 seconds. Compressor will stop and it is
considered total current overload.
The unit can only be restarted after 3 minutes.
If input current <I3, the compressor frequency is reset
based on the OD ambient, set and room temperature.

Inverter-Y Training 2009

PROTECTION
Compressor Discharge
Temperature Control

Inverter-Y Training 2009

PROTECTION
Compressor Discharge Temperature Control

If compressor discharge temperature >102C, running


frequency will be reduced by 1 step. If compressor
discharge temperature still >102C, frequency will be
reduced by another 1 step until temperature falls
between 99C and 90C.
This protection is activated when the compressor
discharge temperature > 110C. The compressor will
stop and considered trip.
The unit can only be restarted after 3 minutes.
If the compressor discharge temperature < 90C, the
compressor frequency will be reset based on the OD
ambient, set and room temperature.

Inverter-Y Training 2009

PROTECTION
High Pressure Protection

Inverter-Y Training 2009

PROTECTION
High Pressure Protection

The compressor frequency is adjusted depend on the


coil temperature.
This protection is activated when the outdoor coil
temperature > 64C, the compressor stop and OD fan
stop after 30s.
The unit can only be restarted after 3 minutes.

Inverter-Y Training 2009

PROTECTION
IPM error

Protection on the IPM


IPM error is declared when;
i) Compressors motor peak current > 21A OR
ii) IPM temperature >100C OR
iii) IGBT peak current > 16A.

Inverter-Y Training 2009

TROUBLESHOOTING

Inverter-Y Training 2009

TROUBLESHOOTING
Fault display by indoor unit
When any error occurs, indoor LED display will keep blinking

LED blinks here

Inverter-Y Training 2009

TROUBLESHOOTING
Fault diagnosis by remote controller

TIMER
CANCEL
button

Hold down ON TIMER CLR or


OFF TIMER CLR for 5 seconds

Inverter-Y Training 2009

TROUBLESHOOTING
Fault diagnosis by remote controller

Press TIMER CANCER repeatedly until ID buzzer produces long


beep

The handset temperature display section will indicate the error code
Error
code

ID unit buzzer will produce long beep if the handset error code =
unit error

A short and two consecutive beeps is not the unit error

Inverter-Y Training 2009

TROUBLESHOOTING
Fault diagnosis using outdoor 7-segment display

Inverter-Y Training 2009

TROUBLESHOOTING
Fault diagnosis using outdoor 7-segment display

7-segment
display

When there is no
error, compressor
running frequency is
displayed, unit: rps
Inverter-Y Training 2009

Flashes error code


when error occurs

TROUBLESHOOTING
Fault diagnosis stored last state error

Remove battery from remote controller


Replace battery again into remote controller
Press Mode & ON/OFF buttons together

Mode
button
ON/OFF
button

Press Mode button to 5:00

Inverter-Y Training 2009

TIMER
CANCEL
button

TROUBLESHOOTING
Error Codes
Error code
A1
A3
A5
A6
C4
C9
E6
E7
E8
EA
F3
F6
H8
H9
J3
J6
L4
L5
P4
U0
U2
U4
UA

Error description
INDOOR PCB ERROR
DRAIN PUMP ABNORMAL
ANTIFREEZE
INDOOR FAN MOTOR ABNORMAL
INDOOR HEAT EXCHANGER THERMISTOR SHORT / OPEN
INDOOR ROOM THERMISTOR SHORT / OPEN
COMPRESSOR START-UP ERROR
OUTDOOR DC FAN MOTOR LOCK
AC INPUT OVER CURRENT
4 WAY VALVE ERROR
DISCHARGE PIPE OVERHEAT
HIGH PRESSURE PROTECTION
AC CURRENT SENSOR ERROR
OUTDOOR AIR THERMISTOR SHORT / OPEN
COMPRESSOR DISCHARGE PIPE THERMISTOR SHORT / OPEN / MISPLACED
OUTDOOR HEAT EXCHANGER THERMISTOR SHORT / OPEN
HEAT SINK OVERHEAT
IPM ERROR / IGBT ERROR
HEAT SINK THERMISTOR SHORT / OPEN
INSUFFICIENT GAS
DC VOLTAGE OUT OF RANGE
COMMUNICATION ERROR
INSTALLATION ERROR

Inverter-Y Training 2009

TROUBLESHOOTING
Outdoor 7-segment display
Parameter

Parameter Description

Number
00
01
02
03
04
05
06
07
08
09
10

Compressor Actual Rotation


Compressor Target Rotation
DC Bus Voltage
Total Current (x10)
Outdoor Air Temperature
Outdoor Heat Exchanger Temperature
Compressor Discharge Temperature
Outdoor Heatsink Temperature
Indoor Air Temperature
Indoor Heat exchanger Temperature
EXV Opening

Press on the tact switch


Display parameter by flashing of 7-segment
Parameter 125, display as 25, follow by 01

Inverter-Y Training 2009

Unit/ range
r/s
r/s
VDC
A
C
C
C
C
C
C
Pulse

TROUBLESHOOTING
Equipments
Digital clamp meter

AC CURRENT

RESISTANT
AC VOLTAGE

Digital multi-meter

Pressure gauge

Inverter-Y Training 2009

TROUBLESHOOTING
Error C4 ID coil thermistor short / open

Remove the ID coil thermistor from PCB


Set digital multi-meter to ohm reading
Measure both terminals on the sensor using multi-meter test leads
The reading must comply with a particular temperature, refer Table 3
If the reading differs by 2C. It is acceptable

Inverter-Y Training 2009

TROUBLESHOOTING
Resistance - temperature

At 25C
Resistance value: 10 k

Inverter-Y Training 2009

TROUBLESHOOTING
Error C9 Room thermistor short / open
Sensor RTH201

1. Possibility low
2. Unit design with air opening at the

front panel to allow sufficient space for


air flow & measurement

3. 10 C < operating temp. < 40 C

Air intake gap for


room temperature
sensing

Inverter-Y Training 2009

TROUBLESHOOTING
Error H9 OD air thermistor short / open
Error J3 Compressor discharge pipe thermistor
short / open / misplaced
Error J6 OD coil thermistor short / open

Share a same
connector
Connection to PCB

Inverter-Y Training 2009

TROUBLESHOOTING
Error H9 OD air thermistor short / open
Thermistor

Remove the OD air thermistor from PCB


Set digital multi-meter to ohm reading
Measure both terminals on the sensor using multi-meter test leads.
The reading must comply with a particular temperature, refer Table 3
If the reading differs by 2C. It is acceptable

Inverter-Y Training 2009

TROUBLESHOOTING
Error J3 Compressor discharge pipe thermistor
short / open / misplaced
Thermistor

Remove the compressor discharge pipe thermistor from PCB


Set digital multi-meter to ohm reading
Measure both terminals on the sensor using multi-meter test leads.
The reading must comply with a particular temperature, refer Table 3
If the reading differs by 2C. It is acceptable

Inverter-Y Training 2009

TROUBLESHOOTING
Error J6 OD coil thermistor short / open
Thermistor

Remove the OD coil thermistor from PCB


Set digital multi-meter to ohm reading
Measure both terminals on the sensor using multi-meter test leads.
The reading must comply with a particular temperature, refer Table 3
If the reading differs by 2C. It is acceptable

Inverter-Y Training 2009

TROUBLESHOOTING
Error P4 Heat sink thermistor short / open

Remove the heat sink thermistor from PCB


Set digital multi-meter to ohm reading
Measure both terminals on the sensor using multi-meter test leads.
The reading must comply with a particular temperature, refer Table 3
If the reading differs by 2C. It is acceptable

Inverter-Y Training 2009

TROUBLESHOOTING
Error E8 AC input over current

Inverter-Y Training 2009

Set clamp meter to AC current


Clamp terminal 1 on the OD unit
terminal block
If the reading < 10 Amp. It is
acceptable

TROUBLESHOOTING
Error U2 DC voltage out of range

positive
lead (+)

negative
lead (-)

Inverter-Y Training 2009

Set multi-meter to DC
voltage
Measure terminals 1 & 2 on
the OD unit terminal block
using multi-meter test leads
If the reading is within 220240 V. It is acceptable

TROUBLESHOOTING
Error F6 High pressure protection

Coil overload
Possible causes: coil dirty and air short circuit

Where a wall or other


obstacle is in the path of
outdoor units intake or
exhaust airflow
Follow this installation
guidelines to avoid air
short circuit

Inverter-Y Training 2009

TROUBLESHOOTING
Error L5 IPM / IGBT error

Possible causes: over current or over heat


At start up: could be due to software
After running some time: could be due to over current or over heat

Heat sink

IPM

Inverter-Y Training 2009

TROUBLESHOOTING
Error UO Insufficient gas
Check pressure reading at rated capacity

Press & hold

Connect pressure gauge to OD service valve


Press and hold on the ID ON/OFF button
Set to high fan mode and temperature at 16 C using remote controller
Under cooling mode:
For 1.0 hp: at 45 rps, the pressure reading should be between 125 150 psi
For 1.5 hp: at 65 rps, the pressure reading should be between 125 150 psi

Inverter-Y Training 2009

TROUBLESHOOTING
Error U4 Communication error

Maximum communication wire length up to 30 meters

External interference or noise

Make sure the recommended type of wire is used

Check for loose connection

Inverter-Y Training 2009

TROUBLESHOOTING
Error UA Installation error

Y5WMY10/15J

Y5SLY10/15D
Inverter-Y Training 2009

Thank You
Q&A

Inverter-Y Training 2009