Sunteți pe pagina 1din 24

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

LIGHTING MANAGEMENT OFFER

PUTTING A STOP TO ENERGY WASTE


PUTTING A STOP TO ENERGY WASTE

1/22

Summary

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Introduction
General characteristics
Switch sensor
Bus SCS
Services

PUTTING A STOP TO ENERGY WASTE

2/22

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Legrand offers two types of solutions and proposes


related services to ensure that your lighting
management project save energy and help the
environment.

"Switch sensor", for local applications

" Bus/SCS system" for centralized applications

PUTTING A STOP TO ENERGY WASTE

3/22

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

LIGHTING MANAGEMENT OFFER :


General characteristics

PUTTING A STOP TO ENERGY WASTE


PUTTING A STOP TO ENERGY WASTE

4/22

Switch sensor

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Characteristics of switch sensor and sensor:

Detection technologies
Functions
Configuration tools

PUTTING A STOP TO ENERGY WASTE

5/22

Detection technologies

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Passive Infrared technology (PIR):

360

PIR sensor detects occupancy through the difference


between heat emitted by body in motion and the
ambient space.

PUTTING A STOP TO ENERGY WASTE

6/22

Detection technologies

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Ultrasonic technology (US):

Ultrasonic detection operates by transmitting ultrasonic


sound waves throughout an area and measuring the speed
at which they come back. Occupant movement changes the
frequency at which sound waves return.

PUTTING A STOP TO ENERGY WASTE

7/22

Detection technologies

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Dual technology PIR/US:

We combine the best of both technologies: PIR and US.


The sensor switches on the lights when both sensing
technologies detect presence, and keeps lighting on as long
as one technology continues to detect.

And

PUTTING A STOP TO ENERGY WASTE

8/22

Detection technologies & applications

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

3 different technologies are available for our detectors


Which technology for which application:

Technology

Compatible application Incompatible application


characteristics
characteristics
- Small, enclosed spaces.
- Spaces where the sensor
has a complete view of the
room

- Very low motion levels by


occupants
- Obstacles blocking sensor view

Ultrasonic

- Open space
- Spaces with obstacles

- High level of vibration or air flow


- High ceilings
- High level of air flow

DUAL

- Spaces with low or variable


motion levels by occupants

PIR

PUTTING A STOP TO ENERGY WASTE

9/22

Detection technologies & applications

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

3 different technologies are available for our detectors

PUTTING A STOP TO ENERGY WASTE

10/22

Detection technologies & applications

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

3 different technologies are available for our detectors

PUTTING A STOP TO ENERGY WASTE

11/22

Additional functions

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Additional functions:

To increase the comfort and the answers to customers


needs we can provide some specific functions like:

Occupancy / vacancy control


Walkthrough function
Day-lighting control
Alerts

PUTTING A STOP TO ENERGY WASTE

12/22

Additional functions

Occupancy-based control

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

PCTO

Switching lighting on and off in response to the occupancy of a particular space

PUTTING A STOP TO ENERGY WASTE

13/22

Additional functions

Vacancy-based control

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

PICTO

Switching lighting off in response to the space becoming vacant

PUTTING A STOP TO ENERGY WASTE

14/22

Additional functions

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Walkthrough function:

This mode switches the lights OFF 3 minutes


after initial occupancy if no motion is
detected after the first 20 seconds.

PUTTING A STOP TO ENERGY WASTE

15/22

Additional functions

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Day-lighting control:

The light level feature holds lighting OFF when


natural light levels rise above a pre-set level.
This setting is adjustable and can be over ridden.
Function activated by default.

PUTTING A STOP TO ENERGY WASTE

16/22

Additional functions

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Day-lighting control:

Night

I enter the room, I switch on the light with


the push-button at the entrance

High daylight

The detector is automatically going to switch off the


light if the threshold of brightness* is reached

Day-light
down

I am present in the room.


The detector automatically switches the light on

Low
brightness

I go out of the room. I switch the light off with the pushbutton. If I forget, the detector will act automatically

PUTTING A STOP TO ENERGY WASTE

17/22

Additional functions

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Day-lighting control:

Example in an
open space

PUTTING A STOP TO ENERGY WASTE

18/22

Additional functions

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Alerts:

Visual (flashing light) and/or audible warning before


impending shutoff.
Factory setting disable
Enable trough Evoluate Configuration tool (882 30)
(1mn, 30s, 10s)

PUTTING A STOP TO ENERGY WASTE

19/22

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

LIGHTING MANAGEMENT OFFER :


Configuration Tools

PUTTING A STOP TO ENERGY WASTE


PUTTING A STOP TO ENERGY WASTE

20/22

Additional functions

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

Configuration tools:

We can adapt switch sensors and sensors parameters


to the needs and the location:
Occupancy / vacancy mode
Sensitivity / Time delay / Day-light level
We can adjust these parameters directly with local trimpot or with configuration tools (88230/88235)

PUTTING A STOP TO ENERGY WASTE

21/22

Configuration tools

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

IR Configuration tools: ref 882 35

THRESHOLD OF
BRIGHTNESS

Ideal for
small
projects

TIME DELAY
Vacancy/Occupancy
mode

Test mode

Walkthrough mode
PIR sensitivity
US sensitivity

PUTTING A STOP TO ENERGY WASTE

22/22

Configuration tools

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

IR Configuration tools: ref 882 30

Ideal for the


repetitive
construction sites
which require a
defined
regulation in all
rooms

You can adjust precisely the:

Time delay
PIR and or US sensibility (4 levels)
Dual technology function (PIR + US and
after only PIR or US, or mixed)
Day-light level
Functions (walkthrough, audible alert before
switch off, etc)

PUTTING A STOP TO ENERGY WASTE

23/22

Configuration tools

LIGHTING MANAGEMENT | PRODUCTS & SYSTEMS

IR Configuration tools: ref 882 30

Other functions:

Download the sensor configuration (to


duplicate the same parameters for repetitive
configurations)
Create files with dedicated parameters
(offices, stairs, restroom)
Day-light calibration
Create groups (room controllers)

PUTTING A STOP TO ENERGY WASTE

24/22

S-ar putea să vă placă și