Documente Academic
Documente Profesional
Documente Cultură
NO LOSSES
No sloughing
Uniform as possible
( no washouts or restrictions)
NO FLOW
Cementing Problems
Placement (mud removal)
Poor centralization channel
Incorrect flow regime channel, mud film, fluid
contamination
Slurry segregation
free water and/or settling
Formation fluid invasion gas or water
Debonding (microannulus)
Water loss
Permeable formation interactions
Hydraulic testing
Temperature, nuclear (cement top)
Acoustic
Sonic (CBL/VDL, CBT)
Ultrasonic (USI): high resolution image
Sonic
(CBL/VDL
)
Principle
Casing
Cement
Formation
Mud
20 kHz
Transmitter
3 ft
Receiver
Bonded cement
CBL amplitude
t
5 ft
Receiver
VDL
0
100
CBL amp
CBL - VDL
CBL measures casing to cement bond
VDL indicates cement to formation bond
5.5 in.
7 in.
7.625 in.
9.625 in.
10.75 in.
13.375 in.
15
18
21
15.5
17
20
23
23
26
29
32
35
38
40
26.4
29.7
33.7
39
40
43.5
47
53.5
40.5
45.5
48
51
54
55.5
48
68
SLS-W
SLS-C
245
243
241
254
253
251
250
278
276
275
273
272
271
269
288
287
285
283
320
318
317
315
340
339
338
337
336
335
385
380
238
236
234
248
247
245
243
271
270
268
267
265
264
262
282
280
278
276
313
312
310
308
333
332
331
330
329
328
378
373
77mV
71 mV
61 mV
59 mV
52 mV
50 mV
47 mV
CBL
mV
TT
us
Good cement
Decrease
May increase
No cement
Equals FP valueConstant
Channeling
Eccentered tool
Decrease
Erratic
Fast formation
Erratic
Decrease
Microannulus
Increases
Constant
Noise
Erratic
Decrease
Cycle skipping
Increase
Increase
Casing collars
Decrease
Slight increase
Stretch
Constant
Slight increase
Good Cement
CBL flat,
low
QC
CBL
Strong
formation arrival
Mean Z
8
MRayl
Weak casing
arrival
USI
VDL
CBL
variable,
high
Strong casing
arrival
Channel
Low-Z
cement
QC
CBL
USI
VDL
Cement Top
Weak formation arrival
Strong casing
arrival
Traces of
contaminated
cement
QC
CBL
USI
VDL
After squeeze
Perfos
USI
CBL
USI
BI
VDL
USI
BI
VDL
Microannulus / Debond
A small gap (< 0.2 mm) between casing and cement formed by
Microannulus
USI
CBL
Wet
Dry
Reads gas.
Special microdebonding
processing
Weakly affected
for very small
gaps (microns)
VDL "bitty"
USI CBL
Good interpretation
Ambiguous