Sunteți pe pagina 1din 23

SHARING SESSION-2

M2000 3G

By Paulus Cahyo Sumarno (paulus.cahyo@gm

M2000 3G
1.NodeB MML Command
Right click on
NodeB, select MML
Command

2.RNC MML Command


Right click on RNC,
select MML
Command

NODE-B MML COMMAND


1.
2.
3.
4.
5.
6.
7.
8.

Checking
Checking
Checking
Checking
Checking
Checking
Checking
Checking

NODEB
NODEB
NODEB
NODEB
NODEB
NODEB
NODEB
NODEB

LICENSE
CE Board Capacity
WRFU Power Max
TX Power Max NodeB
CELL/SECTORS
VSWR board & Alarm
R99 Algorithm & Congestion Control parameter
E1 IP capacity & status

NODE-B MML COMMAND


1. Checking NODEB LICENSE
DSP LICENSE;

NODE-B MML COMMAND


2. Checking NODEB CE Board Capacity
DSP BRD;

DSP BBPTC;
CE BOARD TYPE :

This command only exist in BTS3900

HBBI ==> UL/DL =


128/256
EBBI ==> UL/DL =
384/384
WBBPa ==> UL/DL =
128/256
WBBPb1 ==> UL/DL =
64/64
WBBPb2 ==> UL/DL =
128/128
WBBPb3 ==> UL/DL =

NODE-B MML COMMAND


3. Checking NODEB WRFU Power Max
DSP BRD;

DSP BRDMFRINFO;

NODE-B MML COMMAND


4. Checking NODEB TX Power Max NodeB
LST LOCCELL;

LST LOCELL:MODE=LOCALCELL,LOCELL=1;

NODE-B MML COMMAND


5. Checking NODEB CELLS/SECTORS
LST LOCCELL;

DSP LOCCELL;
LST SEC;
In Pico, better
not connect 2
feeders to
RX_a
and RX_b. But
not in Macro
sites.

NODE-B MML COMMAND


6. Checking NODEB VSWR board and Alarm Active
DSP VSWR;

DSP ALMAF;

NODE-B MML COMMAND

7. Checking NODEB R99 Algorithm & Congestion Control parameter


LST R99ALGPARA;

LST CONGCTRLPARA;

NODE-B MML COMMAND


7. Checking NODEB E1 IP capacity & status
DSP E1T1

DSP DEVIP

RNC MML COMMAND


1.
2.
3.
4.
5.
6.
7.

Checking
Checking
Checking
Checking
Checking
Checking
Etc..

BASIC Configuration of NodeB


RESELECTION CELL
NEIGHBOR RELATION 3G-3G & 3G-2G
IRAT2G & SHO parameters
E1 based on RNC
Code configuration

RNC MML COMMAND


1. Checking BASIC Configuration of NodeB
LST UNODEB;
This command to see the cellname, sectors, configured E1 in RNC.

Check the consistency between nb of E1 in NodeB

RNC MML COMMAND


2. Checking RESELECTION CELL
LST UCELLSELRESEL;

RNC MML COMMAND

3. Checking NEIGHBOR RELATION 3G-3G & 3G-2G


LST UINTRAFREQNCELL; to see 3G adj cell and its adjacency pa

LST U2GNCELL; to see 2G adj cell and its adjacency paramete

RNC MML COMMAND


4. Checking IRAT2G & SHO parameters
LST UCELLINTERRATHOCOV; cell
LST UINTERRATHOCOV; RNC

CASES-NCCR
Problem Solving of :
1. Power Congestion
2. Code Congestion
3. IuB Congestion
4. CE Congestion

Power Congestion
For UL Power Congestion :
1st Solution Step:
1. Check MAXTXPOWER per Cell in LST UCELL
2. Upgrade from 430 to 460 (RNC and NodeB must be set the same)

2nd Solution Step:


1. Check LST UCELLCAC
2. Check UL total equivalent user number (ULTOTALEQUSERNUM) ma
setting is 200
3. If its still default, then upgrade it to 150 or 200
4. Then Check LST UCELLALGOSWITCH
5. Set NBMUlCacAlgoSelSwitch (Uplink CAC algorithm switch ) =
ALGORITHM_SECOND
6. Set NBMDlCacAlgoSelSwitch (Downlink CAC algorithm switch) =
ALGORITHM_FIRST

3rd Solution Step:


1. Check LST UCELLALGOSWITCH
2. In NBMLdcAlgoSwitch, Set UL_UU_LDR (Uplink UU LDR Algorithm: )=1
(ON)
3. Then check UCELLLDR,
4. Set UlLdrFirstAction (UL LDR first action) = BERateRed(BE traff rate

Power Congestion
For DL Power Congestion :
1st Solution Step:
1. Check LST UCELLCAC
2. Check DL total equivalent user number (ULTOTALEQUSERNUM)
max setting is 200
3. If its still default, then upgrade it to 150 or 200
4. Check DL total power threshold (default is 90%), Set to 95%
5. Then Check LST UCELLALGOSWITCH
6. Set NBMDlCacAlgoSelSwitch (Downlink CAC algorithm switch )
= ALGORITHM_SECOND
2nd Solution Step:
1. Check LST UCELLALGOSWITCH
2. Set DL_UU_LDR (Downlink UU LDR Algorithm: )=1 (ON)
3. Then check UCELLLDR,
4. Set DlLdrFirstAction (DL LDR first action) = BERateRed(BE traff
rate reduction), DlLdrBERateReductionRabNum=1,
To see the effect of LDR
GoldUserLoadControlSwitch=ON
VS.LCC.LDR.InterFreq
VS.LCC.LDR.BERateDL
VS.LCC.LDR.BERateUL

Code Congestion

For any code congestion :


1.Check the traffic distribution in Mapinfo, and do traffic sharing using
adjacent parameter changing
2.In crowded area (a lot of nodeB cell servings), reduce the active set
numbers (3 2) . This will impact to the code used for reselection process
3.Reduce HS-SCCHs code number from 4 to 2. HS-SCCH (max 4 per
UE) is only used to decode the next HSPDSCH frame
4.Reduce User Number for Code Adjust for HSDPA = 3 (This is used
in LDR, but in code reshuffling, it also need 2 codes in the process, this
mean in the same time total code that will be used is 6 codes)
5.Increase maximum number of HSDPA in a cells
6.Set the Allocate Mode HSDPA to automatic, and set the proper
number of HS-PDSCH code
7.Activate code LDR Algorithm and set the LDR on 1st action with
Code Adjust
8.Add 2nd, 3rd, etc carriers
9.owntilt the antenna
10.Etc..

Code Congestion

For any Iub congestion :


1.Add E1/IP migration
2.Create FTI (Factor Table Index)
3.In new created FTI, reduce the percentage number of packet transmitted
in Iub (PSINTERDL, PSINTERUL, PSBKGDL, PSBKGUL, etc)
To create TFI :
1. Add TRMFACTOR (to set the reduced PS in Iub)
2. Check ADJNODE (Check ANI of the nodeB)
3. Set ADJMAP for FTI

Code Congestion
Other NCCR
1. MOD UCELLRLACTTIME : OAMGUARDVALFORHIGHRATE (HRate RL NodeB Message
Processing Time) no response/no reply
2. MOD UFACH : Max Transmit Power of FACH (No response/no
reply)
3. MOD UCELLSETUP (MOD UCELL) : NINSYNCIND,
NOUTSYNCIND, & TRLFAILURE
4. MOD UINTRAFREQNCELL (adjacent parameter) :
IdleQoffset1sn[dB], IdleQoffset2sn[dB], ConnQoffset1sn[dB],
& ConnQoffset2sn[dB]
5. HSPA+ Activation : DSP LICENSE (activate DL 64QAM
Function)
LST UCELLALGOSWITH : Cell Hspa Plus function switch =
Cell 64QAM Function Switch : ON & Cell 64QAM+MIMO
Function Switch::ON

THANKS & GOOD LUCK TO