Who We Are
Formed in 1988
Offices in Abu Dhabi, Dubai, Muscat and
Qatar
Specialized In
. Data center site construction
. Telecom room environment
. Power station products
. Building technology services products
. Raised access flooring & under floor air delivery
systems
. IT solutions
. Under floor air distribution
What We Do
Data Center Site Construction
. TATE raised access flooring
. STULZ close control air conditioning
. WAGNER fire prevention, detection & oxygen reduction
.
.
.
.
.
.
system by gas
TTK digital liquid leak detection system
SOCOMEC UPS
VRLA Industrial Batteries
AUTOMATIONs Containerized Datacenter
ORTEA Voltage stabilizer
AIRFIXTURE Under floor Air Distribution
Our Sister
Airpotech LLC
. AIRPOTECH is a sister company of GCSS
. Formed in mid of 2007
. Offices in Dubai, Abu Dhabi, KSA, Muscat & Bahrain
. Specialized in the supply of ground support equipment
and
services for the aviation sector
Organization Chart
Expert Team
Continued
Continued
Project Management
.
.
.
.
.
.
Data Center
Business and technology decision makers
often focus on factors such as performance
and uptime when investing in new
solutions. However, as the amount of data
that companies collect grows, organizations
have had to place more emphasis on a
larger number of factors than they have in
years past.
Close Control AC
Units (CCU)
Germany
USA
Leak Detection
USA / France
France
Europe / China
Containerized data
center
Germany
USA
Smart Bunker
Germany
STULZ CCU
STULZ CCU
. Close Control Units
[Direct Expansion, Chilled Water, Dual Coil (DX+CW),
etc]
. CyberRow Units
. Condensers
. Chillers
. Telecom Range
STULZ CCU
Cyber Air Series
STULZ CCU
EC Fan Technology
Features:
Benefits:
Direct drive
technology, no belts
+
+
+
+
Low vibration
STULZ CCU
Key Element Cooling Std-by Management
Standby
Airflow:
Airflow: 2x
2x 29,000
29,000 m/h
m/h
Fan
Fan absorbed
absorbed power:
power:
2x
2x 8.0
8.0 =
= 16,0
16,0 kW
kW
Lpa,2m
Lpa,2m =
= 2x
2x 59.7dBA
59.7dBA =
=
62.7dBA
2x 112,1 = 224.2 kW net 62.7dBA
sensible
Airflow:
Airflow: 3x
3x 19,000
19,000 m/h
m/h
Fan
Fan absorbed
absorbed power:
power:
3x
3x 2.3
2.3 =
= 6,9
6,9 kW
kW
Lpa,2m
Lpa,2m =
= 3x
3x 50.8dBA
50.8dBA =
=
55.6dBA
55.6dBA
3x 75.1 = 225.3 kW net sensible
Sample:
3x ASD1500CW At 24C/50% with 7/12C water incl. 1/3 standby
capacity
Benefits:
Benefits:
+ Considerable
Considerable energy
energy savings
savings =>
=> Energy
Energy saving:
saving: 9.1kW
9.1kW x
x
8760hr
8760hr x
x 0.20Fils
0.20Fils =
= AED15.945/Y
AED15.945/Y
+ Reduced
Reduced noise
noise levels
levels =>
=> Noise
Noise reduction:
reduction: -7.1
-7.1 dBA
dBA
Understructure Systems:
PosiLock
Low Finished Floor Height PosiLock
Bolted Stringer
Upto 12 in (30cm)
24 in (60cm) or more
Uninterruptible Power
Supply
SOCOMEC UPS
SOCOMEC UPS
Uninterruptible Power Supply
A complete power Solution for Data Centers and
Server Farms
Modulys UPS
Modulys GP UPS
Manufactured in Europe
Modulys UPS : 1.5 kVA to 24 kVA
A Perfect Modular UPS for Datacenter, server
farms and Computer Networks
Modulys GP : 25 to 600 kVA/kW ups
Highly reliable Modular UPS with Unity power
factor
Vertically and Horizontally Scalable UPS
Fully Modular and N+1, N+2 cost effective
redundant System
Easy to install and Hot swappable modules
SOCOMEC UPS
Uninterruptible Power Supply
UPS three / three phase
MASTERYS BC : 8 kVA to 12 kVA
MASTERYS BC : 15kVA to 120 kVA
MASTERYS BC : 160kVA to 300 kVA
LEAD-ACID Battery
VRLA Battery
VRLA Battery
Valve Regulated Lead Acid Battery
VRLA Battery
ealed Maintenance Free Battery Specifically made for UPS & Telecom
Containerized Data
Centre
Fire Prevention
Systems
Fire Prevention
Systems
Oxy Reduct
OxyReduct offers active fire prevention
Fire Prevention
Systems
Oxy Reduct
Produces nitrogen in order to reduce the oxygen vol.
concentration in the room down to 15% where a fire
cannot
start yet people can continue to be present without side
effects.
Early Detection
Systems
Aspiration Detection
System
Intensity of fire
(logarithmic graph)
TITANUSASD
Point-type Heat
Smoke detectors
detectors
Start of counter
t
measures after
t
Early Detection
Systems
Aspiration Detection
System
AIRFIXTURE
Under floor Air Distribution
Smart Bunker
Smart Bunkers
Smart Bunker
Smart Bunker By AST / Cooling by
STULZ
Including:
-
Cooling Solutions
Cooling Load & Air Distribution
Cooling Solutions
Cold Aisle / Hot Aisle arrangment
Cooling Solutions
Cooling (Aisle Containment) / By TATE
Retractable roof
Fire Suppression compatible
Cooling Solutions
CyberRow (InRow) Cooling / By STULZ
For High Density Areas
Cooling Solutions
SmartAir
e
AirBoosterPr
o
PowerAir
e
References
References
2000m2 DC white space @ IMPZ
DXB Goverment
References
2000m2 DC @ PDO Oman
References
DU & Etisalat
References
TwoFour54 - Mubadala
References
Abu Dhabi Financial Centre @ Sowwa
Island - TATE
References
EtisalatT&A
Building
Abu Dhabi, Al
Ain,
Sharjah
(10,000m2)
NATIONAL DRILLING C
New H.Q. Abu Dhabi
TATE - 10,200 m2
References
NBAD New H.Q,
Abu Dhabi
TATE - 15,000 m2
COMMERCIAL BANK OF DUBAI
New H.Q. Dubai
TATE - 16,200 m2
References
AL SALAM AVENUE TOWER
ADCB New H.Q.
Abu Dhabi
Abu Dhabi
TATE 18,400 m2
TATE 20,000 m2
References
LANDMARK TOWER
Abu Dhabi
TATE 45,000 m2
Contact Us
Dubai, UAE
PO Box 13131 | Dubai | UAE
Tel
: +971 4 380 6010 | Fax : +971 4
380 6060
Email : info.main@gcss.ae
Muscat, OMAN
Facebook:http://
www.facebook.com/pages/Gulf-Computer-Sup
port-Systems/292553544157477
Tweet:https://twitter.com/#!/
GulfComputerSup
Questions &
Discussions
Thank You.