Corporate Profile

Gulf Computer Support Systems LLC

Who We Are
Formed in 1988
Offices in Abu Dhabi, Dubai, Muscat and
Qatar
Specialized In
. Data center site construction
. Telecom room environment
. Power station products
. Building technology services products
. Raised access flooring & under floor air delivery
systems
. IT solutions
. Under floor air distribution

What We Do
Data Center Site Construction
. TATE raised access flooring
. STULZ close control air conditioning
. WAGNER fire prevention, detection & oxygen reduction

.
.
.
.
.
.

system by gas
TTK digital liquid leak detection system
SOCOMEC UPS
VRLA Industrial Batteries
AUTOMATIONs Containerized Datacenter
ORTEA Voltage stabilizer
AIRFIXTURE Under floor Air Distribution

Our Sister
Airpotech LLC
. AIRPOTECH is a sister company of GCSS
. Formed in mid of 2007
. Offices in Dubai, Abu Dhabi, KSA, Muscat & Bahrain
. Specialized in the supply of ground support equipment
and
services for the aviation sector

400 Hz Power supply equipment


Pre Conditioned Air
Jet Blast Deflector & Ground Run-Up Enclosures
Permanent/Semi-permanent Hangars for all types of Aircrafts
High Lifters for Aircrafts up to A380 for ground handling
tasks

Spray Booths for Paint Shop Hangars

Organization Chart

Expert Team

Continued

Continued

Project Management
.
.
.
.
.
.

Managing design development


Construction sequencing and scheduling
Project cost control
Managing site instructions and variations
Procurement and logistics
Managing and completing multiple large projects

Data Center
Business and technology decision makers
often focus on factors such as performance
and uptime when investing in new
solutions. However, as the amount of data
that companies collect grows, organizations
have had to place more emphasis on a
larger number of factors than they have in
years past.

Our Product Range


Data Center Application
1

Close Control AC
Units (CCU)

Germany

Raised Access Floor

USA

Leak Detection

USA / France

UPS & Critical Power


Solution

France

Lead Acid Battery

Europe / China

Containerized data
center

Fire Prevention System

Germany

Under floor Air


Distribution

USA

Smart Bunker

Germany

Close Control AC Units


(CCU)

STULZ CCU

STULZ CCU
. Close Control Units
[Direct Expansion, Chilled Water, Dual Coil (DX+CW),
etc]
. CyberRow Units
. Condensers
. Chillers
. Telecom Range

STULZ CCU
Cyber Air Series

STULZ CCU
EC Fan Technology
Features:

Benefits:

High efficiency / Low


power consumption

Scalable air volume


setting via Controller
on demand

Direct drive
technology, no belts

+
+
+
+

Low vibration

Energy savings compared to


standard fans (using stand-by
units) equals increased net cooling
capacity
Easy adaption to changing space
conditions
Additional energy savings
Reduced noise levels
Long and maintenance-free
operation
No abrasion,
No belt dust ,
No additional filtration
Quiet running AC unit

STULZ CCU
Key Element Cooling Std-by Management

Standby

Airflow:
Airflow: 2x
2x 29,000
29,000 m/h
m/h
Fan
Fan absorbed
absorbed power:
power:
2x
2x 8.0
8.0 =
= 16,0
16,0 kW
kW
Lpa,2m
Lpa,2m =
= 2x
2x 59.7dBA
59.7dBA =
=
62.7dBA
2x 112,1 = 224.2 kW net 62.7dBA
sensible
Airflow:
Airflow: 3x
3x 19,000
19,000 m/h
m/h
Fan
Fan absorbed
absorbed power:
power:
3x
3x 2.3
2.3 =
= 6,9
6,9 kW
kW
Lpa,2m
Lpa,2m =
= 3x
3x 50.8dBA
50.8dBA =
=
55.6dBA
55.6dBA
3x 75.1 = 225.3 kW net sensible

Sample:
3x ASD1500CW At 24C/50% with 7/12C water incl. 1/3 standby
capacity
Benefits:
Benefits:
+ Considerable
Considerable energy
energy savings
savings =>
=> Energy
Energy saving:
saving: 9.1kW
9.1kW x
x
8760hr
8760hr x
x 0.20Fils
0.20Fils =
= AED15.945/Y
AED15.945/Y
+ Reduced
Reduced noise
noise levels
levels =>
=> Noise
Noise reduction:
reduction: -7.1
-7.1 dBA
dBA

Raised Access Flooring

TATE ACCESS FLOOR

TATE Access Floor


Access Floor
Removable square tiles providing plenum for air to
circulate below the floor as part of the air conditioning
system, as well as to process piping, power wiring and
data cabling.
Understructure systems to accommodate floor heights
from 12 to 60, however, 24 to 36 FFH are typical.

TATE Access Floor


Concore Panels
Epoxy coated unitized shells consisting of a flat
steel top sheet welded to a formed steel bottom
sheet filled with a highly controlled mixture of
lightweight cement. Manufactured to exacting
tolerances, these noncombustible rigid, solid
panels deliver the ultimate in strength, durability,
and acoustic performance.

TATE Access Floor


Perforated Panels
Are primarily used in applications requiring
delivery of conditioned air to equipment for the
purposes of cooling the equipment.
Typically be used in equipment room applications
such as telecommunication switch centers, data
centers, & corporate computer rooms.

TATE Access Floor


.
.
.
.

Understructure Systems:
PosiLock
Low Finished Floor Height PosiLock
Bolted Stringer

TATE Access Floor


Height of Raised Floor
Small Data Centers / Server
Rooms
(<1000 sq ft) (<93 sq m)

Upto 12 in (30cm)

Medium Data Centers


12 in 18 in (30cm
(1000 5000 sq ft) (93 465
45cm)
sq m)
Large Data Centers
(>5000 sq ft) (>465 sq m)

24 in (60cm) or more

Leak Detection System

TTK LEAK DETECTOR

TTK Leak Detection


Principle of Liquid Leak Detection
Water contact with the sensing cable
Activation of audible alarm & luminous on FG-SYS Digital
Control Panel
Witness of zone @ fault passes from green to red
Display of zone name and location of the leak point on the
FG-SYS LCD screen
Display of date & time of the leak beginning
The contacts of defect are activated
Information is transmitted in mode JBUS on exit RS232/RS485

Uninterruptible Power
Supply

SOCOMEC UPS

SOCOMEC UPS
Uninterruptible Power Supply
A complete power Solution for Data Centers and
Server Farms
Modulys UPS

Modulys GP UPS

Manufactured in Europe
Modulys UPS : 1.5 kVA to 24 kVA
A Perfect Modular UPS for Datacenter, server
farms and Computer Networks
Modulys GP : 25 to 600 kVA/kW ups
Highly reliable Modular UPS with Unity power
factor
Vertically and Horizontally Scalable UPS
Fully Modular and N+1, N+2 cost effective
redundant System
Easy to install and Hot swappable modules

SOCOMEC UPS
Uninterruptible Power Supply
UPS three / three phase
MASTERYS BC : 8 kVA to 12 kVA
MASTERYS BC : 15kVA to 120 kVA
MASTERYS BC : 160kVA to 300 kVA

UPS three / single phase


MASTERYS BC : 8 kVA to
12 kVA
MASTERYS BC : 15kVA
to 20 kVA
UPS single/single-phase
MASTERYS GP : 10kVA
NETYS
600 VA and 800 VA
toPL
20: kVA
NETYS PE : 600 VA TO 2000 VA
NETYS PR 1000 VA TO 2000 VA

LEAD-ACID Battery

VRLA Battery

VRLA Battery
Valve Regulated Lead Acid Battery

VRLA Battery

ade in High Tech manufacturing plant

ealed Maintenance Free Battery Specifically made for UPS & Telecom

GM (Absorbent Gel Material) and GEL Technology

ast range : 7Ah to 3000 Ah

Containerized Data
Centre

Automations Prefabricated Modular Containerized Datacenter

Fire Prevention
Systems

WAGNER FIRE PREVENTION

Fire Prevention
Systems
Oxy Reduct
OxyReduct offers active fire prevention

Fire Prevention
Systems
Oxy Reduct
Produces nitrogen in order to reduce the oxygen vol.
concentration in the room down to 15% where a fire
cannot
start yet people can continue to be present without side
effects.

Early Detection
Systems
Aspiration Detection
System

Intensity of fire
(logarithmic graph)

TITANUSASD

Point-type Heat
Smoke detectors
detectors

Start of counter
t
measures after
t

Early Detection
Systems
Aspiration Detection
System

Under Floor Air


Distribution

AIRFIXTURE UNDERFLOOR AIR DIST

AIRFIXTURE
Under floor Air Distribution

Smart Bunker

Smart Bunkers

Smart Bunker
Smart Bunker By AST / Cooling by
STULZ
Including:
-

Safe cabinet with lock


cooling system
UPS
Fire system
Fits couple of servers

Cooling Solutions
Cooling Load & Air Distribution

Cooling Solutions
Cold Aisle / Hot Aisle arrangment

Cooling Solutions
Cooling (Aisle Containment) / By TATE
Retractable roof
Fire Suppression compatible

Cooling Solutions
CyberRow (InRow) Cooling / By STULZ
For High Density Areas

Cooling Solutions
SmartAir
e

Smart Air Booster

AirBoosterPr
o
PowerAir
e

References

References
2000m2 DC white space @ IMPZ
DXB Goverment

References
2000m2 DC @ PDO Oman

References
DU & Etisalat

References
TwoFour54 - Mubadala

References
Abu Dhabi Financial Centre @ Sowwa
Island - TATE

References
EtisalatT&A
Building
Abu Dhabi, Al
Ain,
Sharjah
(10,000m2)

NATIONAL DRILLING C
New H.Q. Abu Dhabi
TATE - 10,200 m2

References
NBAD New H.Q,
Abu Dhabi
TATE - 15,000 m2
COMMERCIAL BANK OF DUBAI
New H.Q. Dubai
TATE - 16,200 m2

References
AL SALAM AVENUE TOWER
ADCB New H.Q.
Abu Dhabi
Abu Dhabi
TATE 18,400 m2
TATE 20,000 m2

References
LANDMARK TOWER
Abu Dhabi
TATE 45,000 m2

Contact Us

Socially near to you

Dubai, UAE
PO Box 13131 | Dubai | UAE
Tel
: +971 4 380 6010 | Fax : +971 4
380 6060
Email : info.main@gcss.ae

Abu Dhabi, UAE


PO Box 44268 | Abu Dhabi | UAE
Tel
: +971 2 631 9931 | Fax : +971 2
634 6071
Email : info.auh@gcss.ae

Muscat, OMAN

18th November Street | Al Ozaiba | Muscat


| Oman
Tel
: +968 2 449 3269 | Fax : +968 2
449 1437
Doha,
QATAR
Email : info.oman@gcss.ae
Doha | Qatar
Tel
: +974 555 09855
Email : gcssqatar@gcss.ae

Facebook:http://
www.facebook.com/pages/Gulf-Computer-Sup
port-Systems/292553544157477
Tweet:https://twitter.com/#!/
GulfComputerSup

Questions &
Discussions

Its not just about the slides, but our profile

Thank You.