Guideline
2.
3.
5.
4.
Configuration Inconsistency.
RRC.FailConnEstab.NoReply
VS.RAB.FailEstCS.RIPFail
2.
Equipment and Interface Problem.
VS.RAB.FailEstabCS.RNL, VS.RAB.FailEstabCS.TNL.
3.
Network Element and Interface Resource.
VS.RRC.Rej.Power.Cong, VS.RRC.Rej.ULIUBBandCong,
VS.RRC.Rej.DLIUBBandCong, VS.RRC.Rej.UL.CE.Cong,
VS.RRC.Rej.DL.CE.Cong, VS.RRC.Rej.Code.Cong.
VS.RAB.FailEstCs.Power.Cong,
VS.RAB.FailEstab.CS.DLIUBBand.Cong,
VS.RAB.FailEstab.CS.ULIUBBand.Cong,
VS.RAB.FailEstCs.ULCE.Cong, VS.RAB.FailEstCs.DLCE.Cong,
VS.RAB.FailEstCs.Code.Cong
4.
5.
6.
Relocation Problem.
VS.RAB.FailEstCS.Relo
Capability Problem.
VS.RAB.FailEstCS.Unsp .
Setup redirection problem.
VS.RRC.Rej.Redir.Inter.Att VS.RRC.Reject.Redir.Intrat
VS.RRC.Reject.Redir.Service.
B. Call Fail
Analysis Flow
C. Methodology
The methodology to analyze Call Drop problem containing several step below:
1.
Data Preparation
2.
Traffic Analysis.
3.
Equipment Analysis.
4.
Coverage and Interference Analysis.
5.
Signalling Analysis
Hourly/Daily Statistic (CS RAB assignment failure per cell, RRC connection reject per cell,
Cell TX and RX Power, etc).
The latest Site Map, Neighbor relation, and cell configuration/parameter data.
Single subscriber tracing recorded by RNC.
CHR recorded by RNC.
Active and History Alarm.
Data files collected by DT.
The Traffic analysis is related to CE utilization, IUB,IU Utilization, and Code Utilization. This
Information we can get from the Daily/Hourly Statistic.
The RRC Rejection Cause related to traffic utilization can we get in Raw counter below:
VS.RRC.Rej.UL.CE.Cong = UL CE utilization
VS.RRC.Rej.DL.CE.Cong = DL CE utilization
VS.RAB.FailEstCs.ULCE.Cong = UL CE Utilization
VS.RAB.FailEstCs.DLCE.Cong = DL CE Utilization
The Alarm information of RNC, Node b, MSS, MGW, and Interface(Transmission) can we
gather as early diagnosis to reduce time if we found Call Drop problem.
The History and Active Alarm can help to give quick reference for analyzing the network
problem.
Alarms that affect access failure mainly include transmission alarms of the carrier
signaling (E1/T1, SAAL,NCP/CCP, MTP3B, internal IPC and AAL2PATH) and equipment
alarms (clock, CPU, DSP, etc.). If such alarms occured, find out the causes and eliminate
these alarms thoroughly.
Radio network signaling includes signaling of four standard interfaces of UU, IU IUB and IUR.
When an abnormality occurs in the signaling flow, we can check which part of signaling flow is
missing.
The missing of signaling flow should be correlated to UU,IUB,IU, and IUR interface problem.
According to single subscriber tracing messages, the call drop is defined as:
1)
RRC CONNECTION REQUEST FAILURE
- RNC Fails on receiving UL message of RRC CONNECTION SETUP COMPLETE.
2)
Check the call drop time and the signaling message before call drop for further analysis.
The Imsi trace tool with all interface message and monitoring kpi(CPICH RSCP, CPICH ECNO,
UL SIR, UL TX PWR, and DL TX CODE POWER) helping us distinguishing Call Fail Reason.
The Call Fail related to Air Interface or not related to Air Interface problem.
10
It is Shows details of all calls based on output from Trace Management->Interface Trace
Task->UE.
Provide convenient, PC-based analysis
1. Call Message Event
2. The downlink CPICH RSCP and ECNO Distribution.
3. UL SIR Distribution.
4. UE Tx Power distribution.
5. DL Tx Code Pwr
11
3.
4.
5.
12
Bad RSCP
and ECNO
Distribution
High UL TX
PWR
Distribution
Bad UL SIR
Distribution
High DL TX
CODE
POWER
Distribution