Documente Academic
Documente Profesional
Documente Cultură
October 2008
Sales Promotion Group
PA PMK Dept.
Revision 1
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Agenda
Overview of CENTUM VP
Technical Features of HIS
Turbomachinery Control Solutions
Migration Story
Software License
Engineering Policy
Service Business Policy
Schedules
Page 2
Page 3
Overview of
Page 4
Concept.
Page 5
Objectives of CENTUM VP
A platform
realize VigilantPlant
Visibilityto
of Information
Stable and accurate real-time information exchange throughout the plant.
concept.
Predictability of Process
Predictive intelligence that anticipates changes and helps you plan your
actions in advance.
Agility of Business
Value chain-drive responsive operation via adaptive production
management and fast intelligent decision.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 6
e
xcellenc
E
t
e
s
s
A
Asset
mgt
Safety
mgt
ence
Safety Excell
VigilantPlan
t & SE
launch
ProSafe-RS
2005
Operationa
l
Productivit
y
Team
Effectivene
ss
Human
Centric
Automation
AE launch
SE/AE
evolution
PE/LE launch
FieldMate, PRM,
PE Solution
InsightSuiteAE
Center
2006
Global service
2007
Unified &
intuitive
HMI
Turbine
control
2008
Standard-based
collaboration
architecture
Real-time
production
execution
system
Life-cycle
engineering
environment
2009
2010
Lifecycle
Excellence
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 7
Operational
Management
VP-eXchange
Remote HIS
CAMSuite Client
VP-Quantum/FDS Client
Monitoring
& Control
CAMSuite
VP-Quantum/FDS
HIS &
ISS Client
Field network
gateway
Control network
Controller without I/O
Common Field
network(s)
AP Standards for
Wireless
equipment
AP
Page 8
Technical Features of
HIS
CENTUM VP R4.01
Page 9
Page 10
New Features
Wide-screen HIS
CENTUM
VP HIS
CENTUM
VP HIS
Graphic Builder
Inherited Features
(same as CENTUM CS 3000 R3)
Control LAN
(Vnet/IP or Vnet)
Turbomachine
ry I/O Modules
FCS
(Same as CENTUM
CS 3000 R3)
2GB or more
2 GB or more
HDD
Monitor
Graphics
Drive
DVD-ROM
Others
Mouse, NIC
PCI/PCI-X slot for VF701 Card
Floppy Disk Drive (for Keycode)
Remarks: Laptop (Notebook) PC is not supported via Vnet cards.
Page 12
HIS Monitors
16:10 Screen
4:3 Screen
Two monitors
(16:10 & 4:3)
Four Monitors
(only 4:3)
Page 13
Page 14
System Message
Banner compactly
displays essential
information.
Arranged in the plant
hierarchy, Browser
Bar allows operators
to reach necessary
information instantly.
The Container
Window is capable
of combining and
displaying more
than one screen.
Page 15
Status Icon
Display Area
Status Icons
Engineering Functions in
Operation
Offline I/O exists
Request for Equalization
Under Virtual Testing
In Isolation
Vertical length of
each boxes are
changeable by a
mouse operation.
Page 17
Overview/Trend
Preset Menu
Overview/Plant
Tool Button
Name Input
Page 18
Fixed
Both Browser Bar and Graphics are shown in
Overlapping full.
A part of the graphic is covered
by Browser Bar.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 19
Window mode
Up to 5 screens
can be displayed at
the same time.
Page 20
Frames (1) 4 in 1
Combination of
each window can
be changed freely
by the operators.
Page 21
Frames (2) 3 in 1
Combination of each
windows can be
changed freely by
the operators.
Page 22
Zoom Function
Enlarge
graphics by
dragging the
mouse.
A small window
helps you to
navigate which part
of the graphics are
shown.
Page 23
Technical Features of
HIS
Trend Functions
Page 24
Page 25
Page 26
White
Black
Set up by HIS Setup (.sh)
Gra
y
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 27
Index mark
moving
button
Data
axis
Data axis
scroll bar
Time
axis
Index label
Time axis
scroll bar
Page 28
Current Time
Legend
Area
Plotting direction
Page 29
Current
trend
Referenc
e pattern
Data plot starts
from left edge to
right edge side.
Plotting direction
Page 30
Displays plotting data of the designated period or of the long term data
archive.
Data will not be updated.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 31
Analog
Discrete
Page 32
Current Data
Reference Data
Reference Data
Page 33
Legend Area
Grid
Floating
Bar
.
Tag name is shown in single line.
When the cursor is set on the tag name, the tool tip
appears
and the full tag name will be displayed.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 34
Other Technical
Features of HIS
Page 35
Page 36
Shelving
Pane
All Alarms
Alarms in the
Selected Area
Plant
Hierarchy
Information of
Individual alarm
Page 37
Page 38
Page 40
Page 41
Innovation of GUI
The latest GUI Look & Feels
Smooth Gradient
Flexibility
XAML Format Graphic File (eXtensible Application Markup Language)
Active X
Bitmap, JPEG or GIF Formats
Reusability
Tracing P & ID diagram, Connector, Layer, etc. to reduce
engineering cost.
Aiming reduction of development and maintenance cost.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 42
All the Vista colors and Vista fonts can be used for creating
graphics.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 43
Stencil Area to
find and pick up
the parts easily.
NEW
NEW
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 44
Page 45
Page 46
Report Function
Page 47
Test Functions
Page 48
Bidirectional
Connection
CENTUM VP
(Upper Level)
CENTUM VP
CENTUM VP
(Lower Level)
CENTUM VP
Ethernet
CENTUM VP
Project
CENTUM VP
Project
Upper/Lower Level
Upper/Lower Level
CENTUM VP
Project
CENTUM VP
Project
Upper/Lower Level
Upper/Lower Level
Vnet or Vnet/IP
CENTUM VP
Project
CENTUM VP
Project
Upper/Lower Level
Upper/Lower Level
Vnet/IP
Vnet
Router
Page 49
Vnet
Bidirectional
Connection
CENTUM VP
(Upper Level)
CENTUM VP
CS 3000 R3
(Lower Level)
CS 3000 R3
Ethernet
CENTUM VP
Project
CS 3000 R3
Project
Upper/Lower Level
Upper/Lower Level
CENTUM VP
Project
CS 3000 R3
Project
Upper/Lower Level
Upper/Lower Level
Vnet or Vnet/IP
CENTUM VP
Project
CS 3000 R3
Project
Upper/Lower Level
Upper/Lower Level
Vnet/IP
Vnet
Router
* It is recommended to put CENTUM VP in the upper level for the future expandability.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 50
Vnet
Bidirectional
Connection
CENTUM VP
(Upper Level)
CENTUM VP
(Upper Level)
CENTUM CS
(Lower Level)
CENTUM CS
(Lower Level)
Upper Level
Lower Level
Vnet
CENTUM VP
Project
CENTUM CS
Project
Upper Level
Lower Level
Vnet
BCV-V
CENTUM VP
Project
CENTUM CS
Project
Upper Level
Lower Level
Vnet/IP
CENTUM CS
Project
Vnet
TOKUCHU
Vnet
Router
CENTUM VP
Project
Router/
Bridge
Vnet
CENTUM VP
Project
Ethernet
Enet
CENTUM CS
Project
Upper Level
Lower Level
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 51
Turbomachinery
Control Solutions
Page 52
Page 53
Product Features
System Features
Common Platform - CENTUM VP
Total Control Solution from Boiler/BOP to Turbine, and
Rotating Machines
Scalable System from Small to Large Application Sizes
Integration with CENTUM Enhanced Features such as
fieldbus, PRM and others.
BOP = Balance of Plant
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 54
Description
Servo Module
(4 LVDT inputs, 4 AIs, and 2 DIs, 2 AOs and 2 DOs; Overall Insulation)
AEGS1D
Status Display
Note:
These I/O modules work only when installed in a
local node of a KFCS (32 MB), FFCS, or FFCS/L.
Page 55
Description
High Speed Protection Module
(6 AIs, 4 PIs, 8 DIs and 8 DOs; Overall Insulation
AEGP1D
Status Display
Terminal Board
for High-Speed Protection Module
Page 56
Safety Standards
CE Mark Low Voltage Directive:
EN61010-1 for 220-240V AC and 24V DC Power
Supply
Page 57
Description
Logic Builder
Creates logics, via PC screen, that work in the high speed
protection module and download them to the module through
the FCS.
Page 58
US$4,034.8 M
ARC 2007: DCS Worldwide Outlook Market Analysis and Forecast Through 2011
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 60
Coal/Oil/Gas-fired
Combined Cycle
Simple Cycle
Co-generation
Industrial Boilers
IWPPs
Geothermal
Biomass
Waste to energy
Flue gas
desulphurization
(FGD)
Circulating fluidized
bed (CFB) boilers
But there is
NO
Turbine Control!
Page 61
Yokogawas Expectation
Increase Yokogawa
share to 10% = No.4
in the World.
Turbo I/O is a new tool
to expand business.
Show Yokogawas
commitment to
customers in the
Industry.
Catching up with
competitors (ABB,
Siemens, Emerson
and Alstom)
Page 62
Generator
Servo Module
(High-Pressure
/intermediate
- pressure (HP/IP)
stage
Low-pressure
(LP) stage
Generator
Steam in
Steam out
Page 63
Turbine Protection
Turbine Master
Control
Over-speed Trip
Vibration Trip
Bearing Wear Trip
Low Vacuum Trip,
etc.
Startup Control
Shutdown Control
Speed/Load Control
Inlet/Extraction
Pressure Control, etc
High Speed
Protection
Module
5-10 ms
5m
s
Servo Module
Main
Steam CV
Main Stop
Valve
Page 64
Speed/Load control
Over-speed Trip
(Primary/Secondary)
Vibration Trip
Start-up Control
Load Limiting
Over-speed Testing
Valve Testing
Page 65
Control
Valve
HP
LP
Turbine
Speed
Control Valve
Scope of
Steam Turbine
Control
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Speed Sensing
Page 66
Protection
Module
Servo
Module
LS
LS
Valve Position
Control
Overspeed
Interlock
Valve
Actuator
Servo Output:
50 to 50 mA to coils
LVDT Input
Steam from MSV
Drain
DO
Disk Dump
Valve
Emergency Hydraulic Oil
Shut-off
Valve
Fast Acting
Solenoid
Valve
Servo Valve
Page 67
Servo
High Speed TC
High Speed
Protection
Module
Servo
Module
Field I/F
LVDT 4ch, DI 2ch
AO 2ch, POWER OUT
2ch
Internal PID control
period 5ms
Capable of constructing
the redundancy
Field I/F
AI 6ch, PI 4ch, DI 8ch
DO 8ch
Construct the
configurable
logic
Internal logic period
5ms, 10ms
Capable of constructing
the redundancy
Turbine
> Protection
Turbine Master
Control
Page 68
Inputinput
Low_input
High_
Low_value
value
AnalogInx
SysLim1
1
DATA
VTF0/10
VTF0/08
VTF0/06
VTF0/04
CTL13/14
*1
APC01/02
VTF /12
*0
DATA
REF1OUT1
IN_SPAN OUT1
OUT_ZERO
VTA01
OUT_SPAN
AND
0
HYS
FCN
Enable
VTA02
SQ
ResetSys
APB06
Latch
APB07
VTA03
DATA1OUT
APA03
Syslimit1_x
SR Latch
R- Q
APB05
AnalogInx 4
APC01/02
IN_ZERO
SCALING
AND
STS16
VTA04
SEL
DATA2
SEL
2
Step 3 : Off line test on EWS
PC and verify the logic.
DB
Interlock Logic
Step 4 : Download the
pre-defined logic
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 69
Page 70
Page 71
Page 72
Servo Module
Protection Module
Page 73
Test Items:
Page 75
Inputs/Outputs: 83 AIs, 11
AOs, 2 PIs, 114 DIs, 64 DOs
AFV10D CPU nest (FCS1)
CP451
PSU
PSU
CP451
PSU
PSU
SB401
PSU
PSU
CP451
AGS813
AGP813
ADV551(28)
ADV151(25)
AAI543(0)
AAI143(1)
EC401
EC401
AAI543(8)
AAI143(4)
AAI143(0)
AAI143(0)
AAI143(0)
FCS
AFV10D IO nest(FCS2)
SB401
ADV551(19)
ADV551(0)
ADV151(26)
ADV151(0)
ADV151(0)
ADV151(0)
Page 76
Page 77
Win an endorsement.
Verification from WGTCS
Show performances.
Installation Record NuCoastal, USA (by
WGTCS)
Page 78
Page 79
Applicable Markets
Power Industries
Applicable to Steam Turbine Control
YEI Power Group (Mr K. Kawabe) takes
initiatives
Page 80
SIL3 Certification
Page 81
Migration &
Compatibility
Page 82
Migration Overview
2008
CENTUM VP
2001
2005
CENTUM CS 3000
R3
CENTUM CS 3000
1998
1993
CENTUM CS
10 MBPS
Dual EWS
Redunda
nt
ICS
V net
Token
Pass
1983
HIS
PICS
HIS
AVR
FFCS
HIS
VnetI/P
1Gbps
Dual
Redundant
1988
CENTUM V
CENTUM-XL
ENGS
COPS2
COPSV
CFCS2CFCD2
CFFS
ABC
PFCS
FFCS
LFC KFCS
S
EOPS
CFCS EFCD
Overview
R3
VP
LDCS
CS 3000 R2
CS 3000 R3
CENTUM VP
SDCS
CS 1000 R2
CS 1000 R3
CS 3000 R3
Entry Class
CENTUM VP
Entry Class
Page 84
Page 85
CENTUM VP Entry
Class
VL net
Vnet/IP
Migration
V net Router
PFCx-S PFCx-E
Note:
AFV10x
V net
PFCx-S
PFCx-E
Page 87
CENTUM VP
CS 1000 or
CS 3000 entry
class
V net
ABC11SQ2
V net
ooo
PFCS-S PFCS-E
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 88
Existing CENTUM-XL
Existing CENTUM V
Existing CENTUM
CS
Page 90
PRM
PIMS
Plant Resource
Upper
level
clients
Manager
Plant Information
Management System
Ethernet
HIS
V net or
Vnet/IP
Existing CENTUM-XL
Existing CENTUM V
Existing CENTUM
CS
Page 91
PRM
PIMS
Plant Resource
Upper
level
clients
Manager
Plant Information
Management System
Ethernet
HIS
V net or
Vnet/IP
Existing
VP
FCS + CENTUM-XL
Existing I/O
CENTUM
V
Existing
modules
Existing CENTUM
VP FCS
CS
Page 92
PRM
PIMS
Plant Resource
Migration to VP is completed
without changing field wiring!
Upper
level
clients
Manager
Plant Information
Management System
Ethernet
HIS
V net
Existing
R3
FCS + CENTUM-XL
VP FCS
Existing
CENTUM
V
Existing
I/O
modules
Existing CENTUM
VP FCS
CS
Page 93
(Front)
Old Controllers are renewed to
VP without changing field wiring.
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
(Rear)
NO CHANGE in
Field wiring
Field wiring
Page 94
Page 95
From CENTUM CS
Convince CENTUM CS Customers to revamp their systems.
Multi-project connection for CS system is available.
The graphic import work is done via CS 3000 R3 Graphics
(2 steps required) (this is standard function of CENTUM CS 3000)
Except HICS special parts.
Page 96
Engineering Policy
Page 98
Page 99
Service Business
Policy
Page 100
Page 101
Yokogawa listens to
customers and
respects the unique
needs of customers
plant
Yokogawa delivers
customized lifecycle
management
program that best
suits customers
priorities
Delivering just
what customers
plant needs
< ISD-MASP-S07011 Rev.1 >
Copyright Yokogawa Electric Corporation
<October 2008>
Page 102
-Migration Planning
-EOS support
-InsightsuiteAE
Page 103
Page 104