Sunteți pe pagina 1din 25

ESIC HOSPITAL

SECTER -24,NOIDA
COMES UNDER PUBLIC AND SEMI
PUBLIC ZONE AND FOLLOWS NOIDA
BUILDING BYE LAWS
THIS IS 300 BEDDED

PLOT AREA

ESIC BUILDING
14120 SQMT.

GROUND FLOOR

4237.0 SQMT.

1ST FLOOR

4681.0 SQMT.

2ND FLOOR

4222.7 SQMT.

3RD FLOOR

4222.7 SQMT.

4TH FLOOR

4222.7 SQMT.

5TH FLOOR

4222.7 SQMT.

6TH FLOOR

4222.7 SQMT.

7TH FLOOR

4222.7 SQMT.

TOTAL

34254.2 SQMT.

FAR

2.75

HEIGHT

24M

NOIDA
BYELAWS

ESIC
HOSPITAL

NBC

FAR
SHOULD
BE 2.75
Ground
cover
age =
35%

FAR IS 2.75

FAR IS 3

GROUNG
COVERAGE
=35%

GROUND
COVERA
GE=35%

NOIDA
BYELAWS

ESIC
HOSPITAL

NBC

setbacks
provided
6 mtrs.
clear
space is
available
for fire
tender
moveme
nt.

Setback
=6m

Setback
= 6m

NOIDA
BYELAWS

ESIC
HOSPITAL

PARKING
PROVISIONS
1. One parking
space for every
65 sq. meters.
of permissible
FAR area.
2. One
ambulance for
every 375 sq.
meters. of
permissible
FAR area.

one
parking
space for
every 65
sq. meters.

NBC

NOIDA
BYELAWS

ESIC
HOSPITAL

NBC

Same as
nbc

CORRIDOR
SIZES
1. 2.4 M
WIDE
CORRIDOR
2. 3.5 M
WIDE
CORRIDOR

Corridors
and
passage
ways
should
not be
less than
2.4m

STAIRS
NOIDA
BYELAWS

Same as
nbc

ESIC
HOSPITAL
STAIRS
1. TREAD
=300
RISER =150
WIDTH =2000
2. TREAD
=300
RISER =150
WIDTH =2400

NBC
The minimum
width of tread
shall be 300 mm.
Width of stairs
=2.0 m
Max. riser 150
mm and these
shall be limited to
12 per flight.
The minimum
clear head-room
in any staircase
shall be 2.2 m.

Lifts
NOIDA
BYELAWS

ESIC
HOSPITAL

NBC

Same as
nbc

The total headroom has been


calculated on the basis of a car height

Fire and life safty


NOIDA
BYELAWS

Same as
nbc

ESIC
HOSPITAL

Follows
nbc

NBC
FOR HOSPITAL MAXIMUM
TRAVEL DISTANCE SHOULD
BE 22.5 -30 M
EXIT DOORWAY SHALL BE
MORE THAN 1000 MM IN
WIDTH
HEIGHT OF DOORWAY
MORE THAN 2000MM
EXTERNAL FLIGHT SHALL
STRAIGHT FLIGHT MORE
THAN 1250MM WIDE WITH
250MM TREADS AND
RISER LESS THAN 190MM
BUILDINGS 15M IN HEIGHT
SHALL BE PROVIDED WITH
FIRE LIFTS

RECOMMENDED VALUES OF
ILLUMINANCE

NOIDA
BYELAWS

SAME AS
NBC

ESIC
HOSPITAL

FOLLOW
S NBC

NBC
APP.

AIR CHANGE
PER HOUR

HOSPITAL 15-25
S
STERLISI
NG
WARDS

6-8

DOMESTI
C

15-20

LABORAT
ORIES

6-15

LAUNDRI
ES

10-30

OFFICES

6-10

Distance between two adjacent building blocks


Distance between two adjacent building blocks shall be minimum 6 mtrs. to 16 mtrs,
Depending on the height of blocks. For building height up to 18 mtrs., the spacing shall be
6mtrs.and thereafter the spacing shall be increased by 1metre for every addition of 3 mtrs. in
height of building subject to a maximum spacing of 16 mtrs. As per NATIONAL BUILDING CODE,
2005. If the blocks have dead-end sides facing each other, than the spacing shall be maximum
9 mtrs. instead of 16 mtrs.
Moreover, the allotted may provide or propose more than 16 mtrs space between two blocks.
The Authority shall have a right to impose such restriction and limitations as to the number of
storey and extent of height of the building as he considers fit where protected areas, ancient or
historical monuments lie within a radius of one and half kilometer from the boundary line of
such buildings by recording the reasons.
The internal height of the basement (floor to ceiling) shall be minimum 2.4 mtrs from bottom of
beam and maximum 4.5 metre. Except wherever height of equipment's such as electric
generator, air conditioner, fire hydrant etc. is more than 4.5 meter additional height equivalent
to height of equipment's may be permitted. In case of Automatic/semi automatic/ mechanized
parking facility also more than 4.5 meters, additional height may be allowed by the Chief
Executive Officer depending upon the technology and requirement of space. .
The height of basement shall be maximum 1.5 meters up to bottom of the slab above the top
of the drain. In case the basement is flush with the ground level adequate light and ventilation
shall be ensured.
Toilet block for visitors, drivers etc. comprising of minimum a water closet, a bath and 2 urinals
shall be provided on the ground floor.
At least one of the lifts provided shall be of the specification of goods lift.

NOIDA
BYELAWS

ESIC
HOSPITAL

NBC

NOIDA
BYELAWS

ESIC
HOSPITAL

NBC

NOIDA
BYELAWS

ESIC
HOSPITAL

NBC

S-ar putea să vă placă și