Sunteți pe pagina 1din 17

CONCEPT MAPs of

Self Support Tower Design


Analysis
www.company.com

Self Supporting Tower


Top of Platform
Determination of all possibilities forces
acting on structure caused by
equipment

Main Body
Election of Tower Height, Material, Number
of Legs, and Bracing Type

Foundation
Calculation for sufficient strength of
foundation from supporting the whole
structure

www.company.com

Regulation, Standard & Code


NASIONAL
Peraturan Pemerintah Republik Indonesia No. 5 Tahun 2010
Peraturan Menteri Perhubungan No. 26 Tahun 2011
Peraturan Menteri Telekomunikasi dan Informatika Tahun 2006
SNI 03 2847 1992
SNI 03 1727 1989
SNI 03 1729 2002
INTERNASIONAL
IALA Recommendation V 128 2007
EIA TIA

www.company.com

Typical Height Range Performance

50 m ASL Height:
20 NM Max. Range Performance
For type 5 of target

www.company.com

Typical Height Range Performance

www.company.com

www.company.com

www.company.com

www.company.com

Safety Precautions
1. ROTATING MACHINERY
Equipment and tools may induced vibration and can affect to
structural integrity.

2. RADIATIONS HAZARD

www.company.com

Safety Precautions (...)


3. ELECTRICAL SHOCK
All equipment and cable line must be equipped with explosion
proof from electrical hazard.

4. LIGHTNING STRIKES
Outdoor antennas should be grounded with an approved
lighting arresting device. Local codes may apply. The radio
should also be grounded to an earth ground to help protect
both the radio and its user.

www.company.com

Safety Precautions (...)


5. AREA OF TOWER PROVISIONS
10 M minimum distance from residential.
No tower is approximity near high voltase line. Minimum
distance is 120% of tower height.

KEEP CLEAR FROM REACH OF


FALL OF TOWER

www.company.com

Methodologies of Analysis
ASD (Allowable Stress Design)
LRFD (Load and Resistance Factor Design)
Comment:
Many of Standard and Recommended Practice suggest to use LRFD because LRFD
produced structures with a more consistent factor of safety

www.company.com

Design Criteria
A. LOADING
Dead Load, Operational Load & Wind Load
B. STRENGTH ASSESSMENT
Unity Check & Approval Design according to Standard &
Code
C. SLENDERNESS RATIO
Limiting values of effective slenderness ratio (KL/r)
according to Standard & Code
D. MATERIAL
Material election according to strength assessment and
Standard & Code

www.company.com

Design Criteria
E. STRUCTURAL ANALYSIS
Three dimensional structure analysis
F. OUTPUT
Member Stress
Support Reaction
Twist & Sway
Horizontal & Vertikal Displacement
Strength Assessment for Bolt & Base Plate

www.company.com

Other Issue
A. BUILDING PERMIT
A formal permission, process and mechanism from Dirjen
Disnav

KEMENTERIAN PERHUBUNGAN
REPUBLIK INDONESIA

www.company.com

Other Issue ()
B. CORROSION PREVENTION
The environment that cause corrosion (air, sea water, chemical
substances) must be considered for structural integrity.

www.company.com

Placement Tower Leg Plan

www.company.com

S-ar putea să vă placă și