CRJ 700/900

Maintenance Familiarization

Air CONDITIONING

Aug

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

NOTICE !

All information disseminated by


the Training Department is advisory,
and is for reference only.
Study materials distributed during
training will not be subject to revision
and should not be used as reference
or in lieu of, any official publication(s).

2
A
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

General

Air Conditioning System

Heating & Cooling (Packs)


Temperature Control
Conditioned Air Distribution
Avionics Cooling
Pressurization

3
A
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning System

Whats New ?

Different Packs
Recirculation System Added
Cabin Pressure Controllers

Relocated

Outflow Valve

Butterfly Valve
Electronic Control and Actuation

Outflow Valve & Safety Valves

Relocated

4
A
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

5
A
u
g
0
7

Air Conditioning System

Components

AIR CONDITIONING Panel


CABIN PRESS Panel
Avionics Cooling
Panel
Galley Control
Panel

GALLEY CONTROL PANEL

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Air Conditioning System

Air Conditioning System Controllers (ACSCs)

6
A
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Air Conditioning System

Bleed Air Supply Ducts


Air Conditioning Packs
Conditioned Air
Distribution Ducts

7
A
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning System

Components

Aft Distribution Ducts

Mixing Manifold
Recirculation System
Exhaust Systems

Forward Distribution Ducts

Galley Supply & Exhaust


Forward Lavatory
Supply & Exhaust
Avionics Exhaust

8
A
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Indications

Air Conditioning System

ECS synoptic page


Status page
Primary page
(manual only)

9
A
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

General

Provides temperature
controlled (conditioned)
air for heating or cooling.
Located in the
aft equipment bay,
LH & RH overhead

RH Pack
Looking up from the
aft equipment bay door

1
A0
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

General

Components

Air Cycle Machine (ACM)


Control Valves
Sensors
Heat Exchangers
Water Separator

RH Pack
Looking up from the
aft equipment bay door

1
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

General

Air Conditioning Pack

Simplified schematic

1
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components
Pre-Cooler

Cools the bleed air coming


from the manifold.
Bypassed by the HASOV
(Hot Air Shutoff Valve)
when heating is required.

HASOV located
at the end of
this supply

1
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Hot Air Shutoff Valve

Opens to bypass the pre-cooler


in cold ambient conditions
Pneumatically actuated
Fail safe (spring-loaded) closed

Controlled by the ACSC.


No position monitoring

1
A4
u
g
0
7

CRJ 700/900 CL600-2C10


CRJ 900

-2D24
Maintenance Familiarization

Air Conditioning Pack

Pack Ram Air Regulating Valve


Replaces the HASOV
Temperature of the air supplied
to the pack is controlled
by regulating the ram air
allowed to flow through
the heat exchangers.

15
Aug
07

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Flow Control Valve

Located between the venturi


and the heat exchanger

1
A6
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Flow Control Valve

Pneumatically actuated
Controlled by ACSC

Modulated to achieve desired


flow by the FCV torque motor
Shut-off function

Shut-off solenoid

The FCV actuator is spring


loaded closed, but if pressure
is available (> 10 psi), the
valve would open (fail-safe)
Valve is fully closed < 5 psi

Microswitch

Valve position to ACSC

Closed / Not Closed

1
A7
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Heat Exchangers
Plenum

Plenum Check Valve bypasses


the ACM fan in flight

1
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Air Cycle Machine (ACM)

Turbine, Compressor and


ACM Fan on a common shaft.

Shaft supported by air-bearings


Up to 65,000 RPM

1
A9
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Condenser
Water Extractor
Reheater

Air Conditioning Pack

2
A0
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Temperature
Control Valve

Injects hot bleed air into


the cold ACM discharge.
Electric motor actuated
butterfly valve
Manual override lever

Controlled by ACSC

2
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components
Sensors

(Pack Inlet)

Pack Inlet Flow Sensor


(PIFS)
Pack Inlet Pressure Sensor
(PIPS)
Pack Inlet Temp Sensor
(PITS)

2
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components
Sensors

(on the pack)

Compressor Discharge
Temperature Sensor

Senses failed/poor heat exchange

Pack Temperature Sensor


Signal to ACSC to prevent
freezing at the turbine.
Open the TCV more

Pack Discharge
Pressure Sensor

Senses downstream
pressure build-up
if ice is blocking
the condenser.
Opens the TVC more

Pack Discharge
Temperature Sensors
EICAS display
Temperature control
in automatic mode.

2
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Flow Limiting Venturi

Absolute airflow limit


Creates a P which is
sensed by the PIFS.

Pack Inlet Flow


Sensor (PIFS)

Senses P across
the venturi
Sensor failure

Flow Control Valve


driven full open
Logged in MDC

2
A4
u
g
0
7

CRJ 700/900 CL600-2C10

Air Conditioning Pack

-2D24
Maintenance Familiarization

Components

Pack Inlet Pressure


Sensor (PIPS)

PSI signal to ACSC


for flow control.
Sensor failure

ENG BLEED SNSR


Logged in MDC
ACSC uses a
default value

(S)

2
A5
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Pack Inlet Temperature


Sensor (PITS)

Signal to ACSC to:

Modify the mass airflow


calculations
Detect excessive inlet
temperature.

Sensor failure

(Single element fail)


PACK FAULT (S)
(Dual element fail)
PACK

Logged in MDC

ACSC uses a
default value

2
A6
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Compressor Discharge
Temp Sensor

Overheat protection
> 468F for 30 sec, or
> 500F for 1 sec

L/R PACK TEMP

Switch to manual,
then if no temp control,
select pack OFF
Single element failure:
L/R PACK FAULT

Dual element failure:


L/R PACK
ACSC uses a
default value
Fault logged
in MDC

2
A7
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Pack Temp Sensor

Temperature at the
water extractor outlet.
Signal to ACSC for
temperature control

Prevent freezing at the


water extractor

2
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Pack Discharge
Pressure Sensor

Prevent ice downstream


of the turbine.
ACSC senses the difference
between pack outlet and
cabin pressure, and
increases pack
output temperature.
L/R PACK
Failed Sensor =
L/R PACK
MDC log

2
A9
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Components

Pack Discharge
Temp Sensors

Temperature of the air going


to the distribution system
Temperature read-out
on the ECS page.
Used for manual
temperature control
Failed Sensor =

PACK FAULT
MDC log
Pack temperature
will not be displayed
on ECS page.

3
A0
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack

Pack Operation

Flow Control Valve

Modulated by ACSC to control total airflow


and the flow rate change.

Mass airflow schedule calculated dependent on


cabin altitude, and uses PIF, PIP, and PIT.

Flow is reduced as cabin altitude increases

Dual Pack Operation = Normal Flow


Single Pack Operation = Higher Flow

Maintain sufficient flow for pressurization

At pack Start-up:

Quick initial flow rate increase (10 lb/min),


then slower rate increase (0.2 lb/min)
until scheduled flow is reached

Will be closed:

During engine start


With the PACK switch OFF
When engine is shut down
Pack Protection Function

If pack inlet temp or compressor discharge temperature


is > 232C, the FCV is driven toward closed to reduce airflow
until temperature is reduced.

3
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack Messages

L/R PACK TEMP

Pack inlet or compressor


discharge overheat, or
Pack inlet too hot or
too cold in manual

L/R PACK

Failure of:
FCV, PIT sensor,
CDT sensor,
ACSC Ch A & B,
PDT sensor (manual mode)
Pack low pressure

L/R PACK AUTO FAIL


TCV fail, or
PDT sensor overheat
in auto mode

L PACK TEMP
R PACK TEMP
L PACK
R PACK
L PACK AUTO FAIL
R PACK AUTO FAIL

3
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Conditioning Pack Messages

L/R PACK FAULT

Loss of redundancy
in ACSC, or
Degraded ACSC

L/R PACK OFF

FCV closed and


PACK switch OFF

L PACK FAULT
R PACK FAULT
L PACK OFF
R PACK OFF

3
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Ram Air System

General

Ambient air taken from


an inlet at the base of
the vertical stabilizer.
Provides outside air:

To the pack heat exchangers


and pre-cooler.
For cabin ventilation (smoke)
To the hydraulic system heat
exchanger

3
A4
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Ram Air Duct

Inlet at the base of the


vertical stabilizer

Water Sprayer

Sprays water from ACM


water extractor onto
the heat exchanger

Ram Air System

3
A5
u
g
0
7

CRJ 700/900 CL600-2C10

Ram Air System

-2D24
Maintenance Familiarization

Components

Ram Air Valve

Electrically controlled
and actuated
Cockpit RAM AIR switch

Fwd of
RH Pack

3
A6
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Ram Air System Messages

RAM AIR OPEN

Ram air SOV is fully open


RAM AIR OPEN

3
A7
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Temperature Control

General

Modulate the Temperature Control Valve (TCV)

Mixes hot bleed air with the cold ACM output

Automatic control - ACSCs

Inputs:

CKPT & CABIN knobs on AIR CONDITIONING panel


Ventilated temperature sensors (VENTS)
Mix manifold temperature sensors

Manual control - COLD/HOT switches

3
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

ACSCs
AIR CONDITIONING
control panel

Temperature Control

3
A9
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Temperature Control

Components

Cockpit ventilated
temperature sensor

LH console

Cabin ventilated
temperature sensor

Below overhead
bins, left & right

700 Row 5C and 15B


900 Row 1C and 15B

4
A0
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Temperature Control

Components

Mixing Manifold
Temperature Sensors

Located in the cockpit


and cabin supply ducts,
forward of the
mixing manifold.

4
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Temperature Control

Temperature Control Valve

4
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Temperature Control

Operation

Command Limits (Full COLD / HOT):

15 to 35C

Normal temperature control limits (Pack output)

5C (41F) to 70C (158F)

Pull-up / pull-down

On ground, and > 10C difference between the


selection and the actual compartment temperature
will result in a rapid temperature change schedule.

Display fan status

Limits left pack discharge to 40C


if the display fans are inoperative
Prevent overheating of displays

4
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Temperature Control

COCKPIT TEMP MAN

Left pack temp control


selected to manual

CABIN TEMP MAN

Right pack temp control


selected to manual

COCKPIT TEMP MAN


CABIN TEMP MAN

4
A4
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

General

Air Distribution

Cabin & Cockpit


Galley & Lavatories
Aft Cargo Compartment
Avionics Cooling

4
A5
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Aft Distribution Ducts

Mixing Manifold
Cabin & Cockpit
Supply Ducts
Aft Cargo Compartment
Air System
Recirculation System
Exhaust Systems

Air Distribution

4
A6
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Components

Forward Distribution Ducts

Galley and Forward Lavatory


Supply & Exhaust
Avionics Exhaust

4
A7
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Pressure Bulkhead
Check Valves

Air Distribution

4
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Components

Mixing Manifold

Inlets from:

Packs
Recirculation fans
Low pressure ground connection

Distribution to:

Cabin (85%) and Cockpit (15%)


Aft cargo compartment

4
A9
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Recirculation Fans

Cabin air is extracted at


floor level, and is mixed
with pack supplied air.
Disposable filter

Provide up to 34 %
of the total airflow.
May be selected
without the packs
operating.

Air Distribution

5
A0
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Components

Recirculation Fans

Controlled by the
RECIRC FAN switch
Switch ON

Control relays are


de-energized, and
the fans are powered.
Signal to ACSC,
which then monitors
the fan for operation.

Switch OFF

Relays are powered,


and power to the fan
is removed.

ACSCs monitor fan speed


If < 60% rpm:
RECIRC FAN FAULT
status message

Fans have internal fan


overheat protection
Power removed if
overheated.

5
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Cabin

Overhead Outlets

At the ceiling

90% of total airflow

Sidewall Outlets

Along the cabin sidewall,


below the overhead bins
10% of the total airflow

PSU Gaspers
Exhaust

Dado Ducts

To recirculation system

5
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Cabin

Riser ducts
Gaspers supply ducts

Air Distribution

5
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Cockpit

Side Console Outlets


Floor Level Outlet
Gaspers

Overhead Panel
Observers

Disk Valve Outlets

Instrument Panel

Exhaust

Louvered panels
in the floor

Air Distribution

5
A4
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Galley & Fwd Lavatory Air


Conditioned air from
the mixing manifold
Galley Heater

Controlled from
galley panel
Outlets

Galley gasper
Outlet grille near
the service door

Exhaust Fans

Galley
Forward Lavatory

5
A5
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Galley Heater

Underfloor, near the


service door area.
Temperature control

Internal self-resetting
thermostat

Overheat protection

Air Distribution

5
A6
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Galley Heater
Control

Galley Heater Relay

Power from switch


Ground through the
R PACK switch

Overheat

OVHT on switch/light
Latched, and power
must be cycled to reset

Air Distribution

5
A7
u
g
0
7

CRJ 700/900 CL600-2C10

Air Distribution

-2D24
Maintenance Familiarization

Galley & Lav Exhaust Fans


Operate continuously when
AC power is applied

No control switch

Fan speed monitored


by ACSC 2
Internal fan overheat
protection

Fwd Galley/Lav
Exhaust Fan
At avionics door,
RH side

5
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Aft Cargo Conditioned Air


Controls the airflow into
and the exhaust air from
the aft cargo compartment.

Heated if required
Controlled by ACSC 2
COND AIR switch

Air sources:

Mixing manifold
Recirculation Fan

Components

Heater
Inlet Shutoff Valve
Exhaust Shutoff Valve
Exhaust Temp Sensor

5
A9
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Aft Cargo Conditioned Air


Supply Components

Heater
Inlet Shutoff Valve
LH sidewall

Exhaust Components

Exhaust Duct
& Outlet Grille

RH sidewall
Exhaust Temp Sensor

Exhaust Shutoff Valve


Underfloor

6
A0
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Aft Cargo Conditioned Air


Heater

ACSC cycles the heater


on & off to maintain
16C to 27C (60F to 80F)
Internal overheat
protection
At 93C (200F)

ACSC prevents
heater operation
if the SOVs are
closed.

6
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution

Aft Cargo Conditioned Air


Operation

AFT CARGO
COND AIR switch
OFF

Both SOVs
closed

AIR

Conditioned air
SOV and the
exhaust SOV
both opened

COND AIR

Both SOVs open,


heater operates
ACSC cycles the
heater on/off to maintain
16C to 27C (60F to 80F)

Cargo compartment fire

SOVs are closed and


the heater is de-energized

6
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution Messages

AFT CARGO OVHT

Compartment > 104F


AFT CARGO OVHT

6
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Air Distribution Messages

RECIRC FAN FAULT


Either fan failed

Overheat or underspeed

RECIRC FAN OFF

RECIRC FAN switch is OFF

AFT CARGO SOV

Inlet or exhaust SOV


failed to move to the
commanded position.

RECIRC FAN FAULT


RECIRC FAN OFF
AFT CARGO SOV

6
A4
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling System

General

Provides cooling airflow into the CRT displays


Exhausts the air from the CRT displays
and avionics compartment equipment racks.

AVIONICS

6
A5
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling System

Display Cooling
Air Supply

Display cooling
fans 1 or 2.
Conditioned air from
the mixing manifold.

DSPLY FAN selector


Low flow sensor

Detects a low airflow


condition
Failed fans and
no conditioned air.

DISPLAY COOL caution

6
A6
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling System

Display Cooling

Display fans 1 & 2


Air Filter

LH cockpit
side console

DSPLY FAN selector


Low flow sensor

Detects failed fan


DISPLAY COOL
caution

6
A7
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling System

Display Cooling

DSPLY Fan Selection

NORM

Fan 1 operates in flight


Fan 2 operates on ground

GND ALTN

Selects flight fan (#1)

FLT ALTN

Selects ground fan (#2)

STDBY

Both fans are de-energized


Conditioned air is
supplied from the
mixing manifold.

6
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling System

Avionics Exhaust

Piccolo ducts
behind the CRTs
ARINC racks
Avionics exhaust fans

Underfloor, near the


forward wing spar

AVIONICS FAN
selector

6
A9
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling System

Avionics Exhaust

Avionics exhaust fans

Underfloor, near the


forward wing spar.

7
A0
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling System

Avionics Exhaust

AVIONICS FAN selection

NORM

Fan 1 operates in flight


Fan 2 operates on ground

GND ALTN

Selects Flight Fan (#1)

FLT ALTN

Selects Ground Fan (#2)

7
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Exhaust

Fans Control Circuit

Avionics Exhaust

7
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Exhaust
Ground Valve

Open on ground

Avionics exhaust is
discharged overboard

Closed in flight

Avionics Exhaust

7
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Avionics Cooling Messages

DISPLAY COOL

Low airflow to displays


Fan failure

Low speed
Overheat

AVIONICS FAN

Avionics exhaust
fan failed

DISPLAY COOL
AVIONICS FAN

7
A4
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

General

8.3 psid normal limit

41,000 ft aircraft altitude


= 8000 ft cabin altitude.

7
A5
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

General

Pressurization
Indications

Status page

Shown when
operating in
automatic mode.

Primary page

Shown only when


operating in
manual mode.

ECS page

CPAM data
Active pressure
controller
parameters
(shown on the
ECS page only)

Pressurization System

7
A6
u
g
0
7 in
Shown
Manual
Mode
Only

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

Components

CABIN PRESS Control Panel

PRESS CONT switch/light

Select mode of operation


Indication

FAULT
MAN

EMER DEPRESS
switch/light

Opens the outflow valve


(fast dump)

LDG ELV knob

Manual select landing altitude

MAN ALT

Manually position the outflow valve

MAN RATE

Manually set rate of change

7
A7
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Components

Cabin Pressure
Controllers (CPCs)

Avionics bay
ceiling fwd & aft

CABIN PRESS
Control Panel

Pressurization System

7
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

Components

Outflow Valve

6 oclock on the
aft pressure bulkhead
Electrically actuated
butterfly valve

3 independent DC motors

View looking forward


in aft equipment bay

7
A9
u
g
0
7

CRJ 700/900 CL600-2C10


CRJ 900

-2D24
Maintenance Familiarization

Pressurization System

Floatation Valve (Flapper) on the Outflow Valve


NO
STEP

80
Aug
07

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

Components

Safety Valves

Opens at 8.6 psid


Valve position (open)
is reported to the CPCs.
The valves are not
controlled by the CPCs.

8
A1
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

Components

Ground Valve

Forward wing spar


Controlled by the CPCP
Opened on ground
to vent the avionics
compartment
Closed when:

Passenger and
service doors
are closed & locked,
and aircraft is on ground,
or
Throttle advanced
(for pre-pressurization)

8
A2
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

Operation

Auto Mode

CPCs control the


outflow valve
CPCs transfer control
3 minutes after landing.

Manual Mode

Used if both CPCs fail

8
A3
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Operation

Pressurization System

Pressurization Schedule

8
A4
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

Pressure Equalization
Pressure relief valves
Blow-out panels
Equalization valves
Decompression
panels

8
A5
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System

Pressure Equalization

Pressure relief valves


Blow-out panels
Equalization valves
Decompression panels

8
A6
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System Messages

CABIN ALT

Cabin altitude
> 10,000 ft

Except at take-off/landing
at high altitude

DIFF PRESS

Cabin P > 8.3 psid

CABIN ALT
DIFF PRESS

8
A7
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System Messages

AUTO PRESS

Loss of both CPC auto modes


ARINC data from active
channel lost in manual

CABIN ALT

Cabin altitude is
>8500 ft but < 10,000 ft.

ALT LIMITER

Altitude limit function fail


Loss of CPCP power
Loss of OFV or GV
position input to CPCP
Failure within the
CPCP or OFV

AUTO PRESS
CABIN ALT
ALT LIMITER

8
A8
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System Messages

OVBD COOL
GV failed

in flight
on ground, with passenger
and service doors closed

EMER DEPRESS
EMER DEPRESS
switch selected

PAX OXY ON

Passenger oxygen
masks deployed

OVBD COOL
EMER DEPRESS
PAX OXY ON

8
A9
u
g
0
7

CRJ 700/900 CL600-2C10

-2D24
Maintenance Familiarization

Pressurization System Messages

AUTO PRESS 1/2 FAIL


Complete loss of CPC
Loss of input signals

CPAM FAIL

Loss of CPCP CPU


Loss of ARINC data

OVBD COOL FAIL

Ground valve closed on ground


Failure of CPCP

CABIN PRESS MAN

Manual mode selected

CABIN ALT WARN HI


Takeoff/land >8000 ft.

OUTFLOW VLV OPEN


Outflow valve full open

AUTO PRESS 1 FAIL


AUTO PRESS 2 FAIL
OVBD COOL FAIL
CABIN PRESS MAN
CABIN ALT WARN HI
OUTFLOW VLV OPEN

9
A0
u
g
0
7