Sunteți pe pagina 1din 16

PULSOXIMETRUL

CIOLOVAN CRISTINA
IEREMIE MARIA
MINCU ANDRA

PULSOXIMETRIA
ESTE METOD
STANDARD
DESTINAT
MSURRII
SATURAIEI N
OXIGEN A SNGELUI
ARTERIAL.
PULSOXIMETRIA
ESTE UNA DINTRE
CELE MAI UOARE I
MAI FIABILE
MSURTORI
PENTRU DEPISTAREA
HIPOXEMIEI.

OXIGENUL ESTE
PREZENT N SNGE SUB
DOU FORME :
DIZOLVAT I LEGAT DE
HEMOGLOBINA .
HEMOGLOBINA POATE
FI FUNCIONAL I
NEFUNCIONAL .
HB FUNCIONAL
LEAG I TRANSPORT
O2.
HB NEFUNCIONAL
NU ESTE CAPABIL S
TRANSPORTE O2.

PAO2 = PRESIUNEA
PARIAL A O2 DIZOLVAT N
SNGELE ARTERIAL.
SAO2 = SATURAIA
PROCENTUAL A O2 LEGAT
DE HB DIN SNGELE
ARTERIAL.
SPO2 = SAO2 ATUNCI CND
ESTE MASURAT CU
AJUTORUL PULSOXIMETRULUI.

PRINCIPIUL DE
FUNCTIONARE
SNGELE I ESUTURILE
ABSORB O PARTE DIN LUMINA
EMIS DE PROB.
CANTITATEA DE LUMINA
ABSORBIT ESTE DETECTAT
DE FOTODETECTOR.
HB I HBO2 ABSORB N
MOD DIFERIT SPECTRUL
LUMINII.
PENTRU DETERMINAREA
ABSORBIEI SE FOLOSETE
LEGEA LAMBERT-BEER.

Legea Lambert-Beer:
A=*c*l
=coeficient molar de
absorbie
c=concentraia molar
l=lungimea cuvei

SCHEMA BLOC

PULSOXIMETRUL
UTILIZEAZ DOUA
DIODE EMITOARE DE
LUMIN PENTRU
FIECARE LUNGIME DE
UND ( R ROU I IR INFRAROSU ) I UN
FOTODETECTOR
PENTRU AMBELE
LUNGIMI DE UND.

ACESTE FOTODIODE SE ACTIVEAZ I SE


DEZACTIVEAZ DE CTEVA SUTE DE ORI PE
SECUND PENTRU A INREGISTRA ABSORBIA DE
LUMIN N TIMPUL FLUXULUI DE SNGE PULSATIL I
NEPULSATIL.
O DIOD EMITE N SPECTRUL ROU LA 660 NM,
FIIND CUNOSCUT FAPTUL C RATA DE ABSORBIE A
R-HB ESTE MAI MARE LA LUNGIMI DE UND NTRE
600-800 NM.
CEALALT DIOD EMITE N SPECTRUL IR LA 940
NM, DEOARECE RATA DE ABSORBIE A HBO2 ESTE
MAI MARE N INTERVALUL 800-1000 NM.

N TIMPUL CICLULUI PULSATIL SE NREGISTREAZ


ABSORBIA DETERMINAT DE SNGELE ARTERIAL,
VENOS I ESUTURILE ADIACENTE.
N TIMPUL CICLULUI NEPULSATIL SE
NREGISTREAZA ABSORBIA DETERMINAT DE
SNGELE VENOS I ESUTURILE ADIACENTE.

MICROPROCESORUL COMPAR RATA ABSORBIEI N


TIMPUL FLUXULUI SANGVIN PULSATIL I NEPULSATIL,
PENTRU A STABILI ABSORBIA LUMINII
CORESPUNZATOARE SNGELUI ARTERIAL I PENTRU
A DETERMINA SATURAIA O2 N SNGELE ARTERIAL.
N PRACTICA, VARIAIILE DE ABSORBIE SUNT DE 12% N TIMPUL UNUI CICLU CARDIAC.

MICROPROCESORUL PRELUCREAZ DATELE


PROVENITE DE LA FOTODIODE, CALCULEAZ
CONCENTRAIA OXIHEMOGLOBINEI (HBO2) I A
DEOXIHEMOGLOBINEI (HB), APOI PROCENTAJUL
DE OXIHEMOGLOBIN:

SPO2

PULSOXIMETRELE OFER DATE:


CALITATIVE
(DE EXEMPLU, LA
UNELE PULSOXIMETRE CONCENTRAIA
OXIGENULUI DIN SNGE ESTE
PROPORIONAL CU INTENSITATEA
SUNETULUI EMIS DE APARAT).
CANTITATIVE (PE DISPLAY-UL
APARATULUI ESTE AFIAT PROCENTUL DE
SNGE OXIGENAT I FRECVENA
CARDIAC).

MULUMIM PENTRU ATENIE!

S-ar putea să vă placă și